Installation And Energisation Of Chilakhandi Rl Project Under Athmallik Block Of Angul District Installation And Energisation Of Chilakhandi Rl Project Under Athmallik Block Of Angul District
Tender Value
18.79 Lakhs
Estimated cost
Bid Submission
12 Jan 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
angul → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Installation And Energisation Of Chilakhandi Rl Project Under Athmallik Block Of Angul District Installation And Energisation Of Chilakhandi Rl Project Under Athmallik Block Of Angul District
BOQ
| Sl. No. | Item Description |
| 1 | Civil Works (Part-A) |
| 2 | Earth work excavation in foundation in hard soil with 50 mtr initial lead 1.5 m initial lift including rough dressing and breaking clodsto 2 cm to 7 cm and laying in layers not exceeding 0.3 m in depth as per direction of Engineer-in-charge |
| 3 | Filling foundationand plinth with sand watered and rammed as per direction of Engineer-in-charge. |
| 4 | Cement concrete (1:4:8) with 4 cm size h.g metal as per direction of engineer-in-charge. |
| 5 | Cement concrete (1:2:4) with 12 cm size h.g Chips as per direction of engineer-in-charge. |
| 6 | Rigid and smooth centering and shuttering for RCC work including false work and dismentalling them after casting including cost of materials complete. |
| 7 | a) in foundation |
| 8 | b) Lintel |
| 9 | c) Column Beam |
| 10 | RCC (1:2:4) with 12 mm size HG chips as per direction of engineer-in-charge. |
| 11 | Supplying, fitting and placing oncoatedHYSD (TISCON) bar reinforcement complete as per drawing and technical specification including cutting, binding, bending and cost of binding wire. |
| 12 | Cost of MS Grill for windows |
| 13 | Cost of Iron Shutter |
| 14 | Fly Ash Brick (25cmx12cm x8 cm) having crushing strength not less than 35kg/cm with dimensional tolerance ± 5% in cement mortar (1:6) in foundation and plinth. |
| 15 | Fly Ash Brick (25cmx12cm x8 cm) having crushing strength not less than 35kg/cm with dimensional tolerance ± 5% in cement mortar (1:6) in super structure. |
| 16 | 2.5 cm thick A.S flooring with C.C. (1:2:4) including punning as per direction of Engineer-in-charge. |
| 17 | 2.5 cm DPC with CC (1:2:4) using 12mm size hg chips as per direction of Engineer-in-charge. |
| 18 | 12mm thick cement plaster (1:6 ) over brick masonary as per direction of Engineer-in-charge. |
| 19 | 6mm thick cementplaster (1:6) as per direction of Engineer-in-charge. |
| 20 | Filling F & P with excavated materials, moorum including watering and ramming as directed by the engineer-in-charge |
| 21 | 10 cm Thick dray brick Khoa rammed ,well watered as per direction of Engineer-in-charge. |
| 22 | White washing three coats with shell time as per direction of Engineer-in-charge. |
| 23 | Cement punning over cement plaster as per direction of Engineer-in-charge. |
| 24 | Finishing wall with water proffing cement paints two coats for exterior walls as per direction of Engineer-in-charge. |
| 25 | Cost of supplying transportation and fixing in proper place and position including required size full threaded TVS nut bolt with CC (1:2:4) as per site condition |
| 26 | Supplying of unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms.cc, of straight length of 6 (six) meter for portable water suppliers conforming to IS-4985/2000 of BIS- Amendment 2 read with Table =1 of IS specification bearing ISI marks for working pressure CI -IUO=PVC pipe to withstand pressure of 2.5 Kgf/sqcm/4.0 Kgf/sqcm/6.0 Kgf/sqcm/8.0 Kgf/sqcm and the specification and manufacturer name should be prominenity marked on body of each pipeas per the latest Amendment of IS 4985.it includes the cost of sockets in case of plain ended pipe PDI test are to beconducted and should be marked on body of each pipe and report is to be obtained from CIPT, Bhubaneswar/ EPM, Orissa, Bhubaneswarnecessary approval of authority including transporotation and laying at site all complete with cost of solvent cement. |
| 27 | i) 160 mm dia (Class-I) |
| 28 | ii) 200 mm dia (Class-I) |
| 29 | 10 HP Monoblock centrifugal pump set at total of 16mtr capable to discharge 1700 LPMsquirrel cage induction motor fitted with companion flanges and class -F insulation suitable for operation 415 volt+6%-15%, 3phase, 50Hz AC power supply and full load current 15.6 amp with size of suction and delivery 100mmx100mm dia with overall efficiency 60 -65. The materials of construction as given below.a) Casing:F.C. 200 as per IS 210/1978b) Impeller: Bronze grade LTB-2 of IS c) Shaft : High carbon steel grade 40c8 of IS 1570(Part-2)318/1981d) GAsket: As per IS 5120/1977 and the pump sets must be as per IS-9079/2002 of reputed brand havingwide dealership net work for easy availability of spares. |
| 30 | Supplying fitting fixing control pannel starter, BCH make with arrangement of volt meter, Amp, Meter mfitted with MCB control switch complete including indicator lamp with irrigation pannel bozard of apaproved design made out of 16gauge CR sheedt basement MS angle with double lock powder coat painting over one coat primere including fixing danager board with lucking devices and fixing of suitable stand for control pannel unit. |
| 31 | 3 oh 4 wire20-100Amp3x230Volt (P-N) 50 AMP energy meter with ISI mark as approved by DISTCO CEDSU with matching fibre glass TP box for current meter including supplying, testing and energisation with Kit-kat. |
| 32 | Motor hood cover of 18 gauge C.R. sheet with double coat painting over one coat primer so as to cover the motor |
| 33 | MS base plate for fitting of pannel and pump as per sample as per direction of Engineer-in-charge. |
| 34 | 3 x 10 sqm Tarpodar Cable XLPE (Cross like polythylin) confirming to IS-7098 (Part-II) including laying below 9 mtr of the ground & fitting the excavated materials including watering & ramming. |
| 35 | 63/100 AMP 415 volt T.P. main switch confirming to IS 4064 (Pt-I & Pt-II) with utilisation category Ac-22. |
| 36 | Supply, fittintg and placing of 100mmdia Nominal Bore GI pipes having wall thickness 4.5 mm electrical resistance welded of medimum class confirming to IS-1239 (part-I/2004) with latest amendments, screwed at both ends as per IS-554 socketed at 1 end and other end protected with plastic threaded protector. The socket confirming IS-1239 (Part-II/1992) with latest amendments in rendom length of 4 to 7 mtrs. Each pipe shouldbear ISI certification and manufacturers name /trade mark. |
| 37 | Labour charges for fitting, fixing of suction, delivery fitting including M.S. Tee set, NR valve, Switch valve and Air release valve etc minor welding transportation of materials to site etc. including nut, bolt rubber insallation etc complete. |
| 38 | 100mm dia C.I. Screw base foot valve (Kirloskar make ) IS |
| 39 | 100mm dia G.I. bend IS No 1239 (Part-II/1992) |
| 40 | 100mmdia G.I. flange IS No 6392/1971 |
| 41 | 100 mm dia C.I. N.R valve IS No 5312 (Part-I) with ISI mark |
| 42 | 100mm dia C.I. sluice valve IS No 14846-2000 (Part-I) |
| 43 | 200x200x160mm PVC Tee set with bend,closing and opening arrangement |
| 44 | 160x160x100mm PVC raisar Tee with assoceries |
| 45 | Cost of Butter fly valve |
| 46 | 200mm PVC Socket |
| 47 | 50mm dia C.I. Air Release Valve IS Mark14845(SI)with 1 mtr long G.I.Short piece with saddle |
| 48 | 100x100x25mm dia G.I. Tee with Plug for Priming set |
| 49 | 200mm dia PVC end cap confirming to I\PL-R PVC-IS 2000 F |
| 50 | 160mm dia PVC end cap confirming to I\PL-R PVC-IS 2000 F |
| 51 | 200x100mm/PVC/GI/M.S Reducing Socket IS 2000F |
| 52 | Labour charge for laying and fitting 160mm PVC pipe |
| 53 | Labour charge for laying and fitting 200mm PVC pipe |
| 54 | Empty Panel Board |
| 55 | Electrical Works (Part-B) |
| 56 | Construction & erection of 11 / 0.416 KV ,25 KVA/ 63 KVA, (3 star rated transformer) D.P. Substation confirming to RE Rules 1956, mounted on 2.44 Mtr long structure, supported in 300 Kg 9 Mtr long PSC 35pole, transformer hard channel & top channel made of 2.8 M long 100x50x6 mm M.S. Channel, Transformer belting on 2.80 M long 50x50x5 mm M.S. Angle, (all REC SPN. Std. F-3) with all accessories like 3 pole 11 KV HG Fuse (F-5) & A.B. Switches (F-9) both mounted on 2.8 M long 75x40x6 mm M.S. Channel and supported by 1.0M long 50x50x5 mm M.S. Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for 63 KVA S/S, Pipe earthing (F-2) , including cost of 50 Sqm 3.5 CorePVC Cable carpping & padding of Poles, Danger board at each Pole, Anti Climbing Devices & all other necessary fittings i.e. required size Nuts & Bolts, Brackets, Cable, Cable Sockets etc. including cost of all materials, labour, transportation complete with liasioning for testing inspection & commissioning. Birck Fencing (size 15\"x10\") with construction of retaining wall, erection of RCC fencing post, sand filling and metal spreding, fixing of Iron grill gate etc as per CESU specification. |
| 57 | i) 25KVA Sub Station |
| 58 | Construction of 3 phase 11 KV line as per REC standard confirming to RE Rules 1956 with 300 Kg 10 M long PSC Pole support in 50 M span, 55 Sqmm Insulated Conductor, 11 KV \"V\" Cross arm , with required No.of 11 KV T & CDisc.Insulators & 11 KV Pin Insulators, Carping & Padding of Poles, Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & Double Stay at end point with 18 mm G.I. H.T Stay , concreting of Stay with Anchor plate, guarding at Road crossings etc.including cost of all materials, labour, transpotation, inspection & commissioning etc. complete. |
| 59 | Electrical Earthing with 40mtr dia medium duty GI earthing pipe each 3 m longwith installation including cost of all materials like GI flange chorcoat, salf etc. as required as per I.E Rule |
| 60 | Other Electrical materials such as pvc tape.7/20pvc copper wire 3/20 pvc copper wire G.I flxible condite pipe no 6 GI wire copper cable socket GI socket and petty materials required for electrical installation. All materials should be as per IS including fitting charges |
AI Tender Summary
Tender Timeline
Jan 05, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJan 12, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 15, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender