Power Government Departments Closing in 0 days TDR #30586616

Hpsebl/Ceocz/Mm/Nit -23/2021 Survey Design Erection Testing And Commissioning Of 33/11 Kv Stn 1X3.15 Mva At Samila Including Civil Work And Terminal Equipments At Khudle End In Esd Baldwara Ed Sarkaghat Under Operation Circle Hpsebl Mandi

Issued by Government Departments · sarkaghat, Himachal Pradesh
Tender Value
1.52 Crore
Estimated cost
Bid Submission
12 Jan 2022
0 days left
EMD
1.52 Lakhs
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
sarkaghat → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Hpsebl/Ceocz/Mm/Nit -23/2021 Survey Design Erection Testing And Commissioning Of 33/11 Kv Stn 1X3.15 Mva At Samila Including Civil Work And Terminal Equipments At Khudle End In Esd Baldwara Ed Sarkaghat Under Operation Circle Hpsebl Mandi

BOQ

Name of Work: Survey design Erection Testing and commissioning of 233/11 KV, 1X3.15 MVA Sub Station (Manned) at Smaila including Civil work along with Terminal equipments at Khudla End under ESD Baldwara, ED Sarkaghat in operation Circle HPSEBL Mandi.
Sl. No. Item Description
133/11 KV Sub Station &Terminal equipment
2Transformer (s)
3Power Transformer (3.15MVA,33/11KV,ONAN,OLTC,outdoor)
4100 KVA, 33/0.4 KV S/Stn, transformer
533KV Switchgear & Allied equipment:with 1 No.33 KV Incomer
633 Kv control and relay (CR) Panel(with numeric differencial Relay, IEC 61850)
733 Kv control and relay (CR) Panel(33 Kv incomer Bus)(NumericRelay, IEC 61850)
836 Kv VCB (36 Kv, 1250A, 26.2 kA, outdoor Type 2 No for SubStation
936 KV Isolator(1250A,36 KA,with earth switch)
1036 KV Isolator(1250A,36 KA,without earth switch)
1133 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
1233 kV Current Transformer (33 kV, 1 F, 200-100/1-1-1-1A)Ratio Multi Core, Outdoor) (1 No. per F)
1333 kV Current Transformer (33 kV, 1F, Multi Ratio Multi Core,Outdoor) (1 No. per F) (400-200/1A) for teminal equipment
1433 kV Potential Transformer (33 kV/110 V, 1F, Multi-Core, Outdoor), (1No. per F)
1533 kV Drop Out Fuse Unit (33 kV, Expulsion)
1611 KV switchgear and allied equipment (1 No.incomer Bus)
1711 Kv incommer Bus control and relay (CR Panel with VCB (12 Kv, 1250 Amp, 25 kA)[ Numeric relay, IEC 61850] with CT ratio 600-300/1-1-1-1 A &4 Nos. outgoing feeder panels with 200/100/1A
1811 kV LA/ Surge Arrester (9 KV, Station Class, ZnO, Porcelain, Outdoor)
1911 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured){Transformer to 11 kV Bus}{50m+ Spare- 50m}
2011 kV Cable Termination Kit (400 mm², Outdoor)
2111 kV Cable Termination Kit (400 mm², Indoor)
2211 kV Switchgear and Allied equipment: Single (4 No.Outgoing Feeder )
2311 kv outgoing feeder control and relay (CR) Panel with VCB (12Ka,1250A,25KA)(4 Nos Feeder)
2411 kV Isolator (12 kV, 1250 A, 25 kA,without Earth Switch, Outdoor)
2511 kV LA/ Surge Arrester (9 kV, Station Class, ZnO, Porcelain, Outdoor)
2611 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured){Busbar VCB to Isolator}{250m+ Spare- 50m}
2711 kV Cable Termination Kit (185 mm², Outdoor)
2811 kV Cable Termination Kit (185 mm², Indoor)
29LT Cable(1.1 kV,3.5 Core 70 mm2){from station Tfr)
30CAPACITOR BANK:- (REC Spec. 19/1981)
31Capacitor Bank (3-?, 50 Hz, 1800 KVAr) [ IS:2834 ]
32Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
33General Equipment
34Battery Bank with Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 100 AH)
35Distribution Panel (30V, DC)
36Distribution Panel (415 V, AC)
37SUPERSTRUCTURE & BUSBAR
38(i) R.S. Joists, size 12800x250x125 mm 12 supports i.e. (12x12.8x37.3)=5729.3 kg say 5.729 MT
39(ii) R.S.Joists, size 4200x225x150 mm supports for Power Transformer\"s LA,Station Transformer LA,I/C Power Transformer\"s CTs(10x37.3x4.2)=1567 kg say 1.567 MT
40M.S. Plate 500x500x10 mm for Top and Bottom of R.S. Joists i.e. 2x20=(40x15=600 Kg)+(40x10=400 Kg)=880 kg
41M.S. 16 mm Dia Foundation Bolts with washers & Nuts etc.
42(iv) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m At 5% wastage for Bus-bar,Isolators,CT,LA\"s transformer etc. (a) 22.25 Mtr long=8 No. (b) 7.125 Mtr long=20 No (c) 4.5 Mtr long=8 No. (d) 0.750 Mtr long =40 No.Total =22.25x8+7.125x20+4.50x8+0.75x40=386.5=387 Mtr+82mtr fot terminl equipment at Khudla end
43(vi) M.S. angle iron 65x65 X-arm @ 5.8 kg/mfor body supports belt of station transformer
44(viii) Nuts & Bolts with Washers off sizes
45BUS-BAR
46(i) 3 disc insulators tension string complete with fitting
47(ii) ACSR conductor 200 mm²for bus bar and jumper
48(iii) Tee connections
49(iv) PG clamps
503 disc Suspension tension string complete with fitting
5111 kV Super Structure & Busbar per feeder
52(a) Steel tubular pole 11 m long with base plate for 4 nos. out going Feeder
53(b) RCC muffs & concreting thereof for 4 nos. out going Feeder
54CROSS ARMS
55(a) 4.4 m long M.S. channel iron 125X65X6 mm 13.4 kg/m Cross armsfor Sub-Station With 4 nos. out going Feeder
56(b)M.S. angle iron 65x65X6 mm 5.8 kg/mCross arms for Sub-Station With 4 nos. out going Feeder[4.4x3x12+5.32x2x12=286.08 m]
57(b) M.S. Half Clamps for 4 nos. out going Feeder
58(c) Full Clamps for 4 nos. out going Feeder
59(d) Nuts & Bolts of Various Sizes(Galvanised/Coated)[Preferably 16 mm ? or more (with flat spring washers)] for 4 nos. out going Feeder
60Single insulators tension string for S/Stn with 4 nos. out going Feeder
61ACSR 100 mm² Conductorfor Jumper[approx. 4mtr /phase]
62Discs Insulator sets(comprising 1 No. Disc:(Porcelain,BS,12 kV,90 kN)
63Clamps for 4 nos. out going Feeder
64EARTHING (33 kV Sub-Station)
65Cost of Material for Earth Mat laying
66Earthing of 33 kV yard & equipment &11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:-(a) For 3 no. Transformer earthing at 3 points (body & neutral) at 10 m Each (2x3x10)x 1.05=63 m(b) For 3 sets of LA\"s at 4.2 mtr each 3x4.2x1.05=13.23m(c) For 33 kV super structure at 11.5 mtr each 15x11.5x1.05 =173.25 m i.e. 173 Mtr(d) ForVCB & CT body earthing at 10 m Each (12x10)x1.05=126 MtrTotal (a+b+c+d) =375.23 m82.4 kg / mtr=900.55 =0.900 MT
67GI wire no. 6 SWG for screening etc.
68Eye block for screening
69Turnbuckle for Screening
70Earthing material(Pipe) type
71G.I. Pipe 50 mm dia with holes of 16 mm dia at 150 mm from centre to centre for 2 m Distance from bottom.
72M.S. plates 150x150x6 mm for two connection 2x3x1.13=6.78 kg
7350x6 mm M.S. flat connection with the mat to mat2x3x4.8=28.80 kg
74Nuts & bolts galvanized 16 mm dia, 50 mm long 2x3x0.5=3 kg
75Chequred plate cover 500x500x6mm i.e. 11.8 kg=2x3x11.8=70.8 kg
76M.S. flat 50x6 mm for ground mat including 5% wastage & weighing 2.4 kg/m (15x21+30x12)x1.05=708.75 m or 1701 kg say 1.701 MT
77Earthing pipe electrode
7820 mm round, 3 m Long & weighing 2.47 kg/m for 27 no.electrode 27x3x2.47 =200.07 kg, say 200 kg
79YARD LIGHTING
809 m, Steel Tubular poles for yard lighting
8118 W LED Lamp complete with fittings
82Post Erection for gate
83Clamps for GI pipe bracket
84Underground cable 16 mm² for yard lighting
85PVC cable size 6 mm² for connecting LED lamp supply
86Junction box i/c MCCB and other allied
87Lighting Emergency (3 No LED Bulbs with holders / wire)
88Control and LT power cables
892x2.5 mm²multi strand copper control cable
904x2.5 mm² multi strand copper control cable
9112x2.5 mm² multi strand copper control cable
923.5 core 95 mm² aluminium cable suitable for 415 V, AC
93Fire Fighting System
94ABC Type(Portable, Dry Chemical, 9 kg)
95ABC Type(Portable, Dry Chemical, 25 kg)
96Mechanical Foam Type with Trolly 50 Ltr
97Fire Bucket along with stand (4 Bucket)
98Civil work
99Out door Cable trench
100Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
101Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
102Centering and shuttering including strutting, propping etc. and removal of form for:
103Foundations, footings, bases of columns, etc. for mass concrete.
104Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
105Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
106Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
107Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
108Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
109C/O Indoor Cable trench
110Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
111Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
112Centering and shuttering including strutting, propping etc. and removal of form for:
113Foundations, footings, bases of columns, etc. for mass concrete.
114Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
115Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
116Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
117Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
118Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
119C/O RCC Foundation for 3.15 transformer
120Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
121Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
122Centering and shuttering including strutting, propping etc. and removal of form for:
123Foundations, footings, bases of columns, etc. for mass concrete.
124Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
125Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
126Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
127Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
128Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
129Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm.
130Supplying, filling, spreading & leveling gravels of approved size in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
131C/O RCC Foundation for 33 KV Circuit Breaker for 3 no VCB
132Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
133Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
134Centering and shuttering including strutting, propping etc. and removal of form for:
135Foundations, footings, bases of columns, etc. for mass concrete.
136Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
137Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
138C/O RCC Foundation for CT and PT
139Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
140Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
141Centering and shuttering including strutting, propping etc. and removal of form for:
142Foundations, footings, bases of columns, etc. for mass concrete.
143Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
144Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
145C/O Cement concrete road for proposed 33/11KV Sub Station
146Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
147Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
148Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
149Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
150C/O Main Gates for proposed 33/11KV Sub Station
151Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
152Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
153Centering and shuttering including strutting, propping etc. and removal of form for:
154Foundations, footings, bases of columns, etc. for mass concrete.
155Columns, Pillars, Piers, Abutments, Posts and Struts
156Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
157Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
158Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
159Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
16015 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand).
161Finishing walls with water proofing cement paint of required shade. New work (Two or more coats applied @ 3.84 kg/10 sqm)
162Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
163C/O Station Transformer Bed for proposed 33/11 KV Sub Station
164Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
165Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size)
166Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size)
167Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
168Providing and laying Sand and Aggregates in Yard for proposed 33/11 KV Sub Station at Sh. Naina Devi Ji under Elecrical Sub-Division Kot under Electrical Division HPSEBL Bilaspur (H.P)
169Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil.
170Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
171Supplying, filling, spreading & leveling gravels of size range 20 mm to 40 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge
172Providing and Fixing Chain link fencing for proposed 33/11 KV Sub Station
173Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
174Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
175Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size)
176Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
177Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
178Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
179Painting with aluminium paint of approved brand and manufacture to give an even shade . Two or more coats on new work
180C/O Control Room Building for proposed 33/11 KV Sub Station
181Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
182Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size)
183Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
184Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
185Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
186Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in_x0002_charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15)
187Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
188Extra for P/F galvenised M.S wire gauge of I.S gauge designation No 140 g to door windows and clearstory windows with wire of dia 0.71 mm instead of I.S gauge designation No 85 g with wire of dia 0.56 mm.
189Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
190Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’sspecifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
191Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
19220 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
1936 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
194Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
195Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile.
196Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50grams/litre
197Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
198Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
199Suspended floors, roofs, landings, balconies and access platform.
200Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size)
201Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size).
202Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars.
203Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
204Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing &finishing the top smooth.
205Providing and fixing aluminium hanging floor doorstopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper.
206Constructing Course rubble hammer dressed \"U\" shape open surface drain with side wall. 15x22 cm in cement mortar 1:6 (1 Cement : 6 Sand) and inside plastring with cement plaster 1:3 (1 Cement:3 Sand) including earth work and laying 10 cm cement concrete in 1:5:10 (1 Cement : 5 Sand : 10 graded stone aggregate) of 40 mm nominal size) and 7.5 cm cement concrete 1:2:4 (1 Cement : 2 Sand : 4 Graded stone aggregate of 20 mm nominal size) and finished with a floating coat of neat cement complete as per standard design.
207Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
208Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10mm
209Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
210Providing and fixing bright finished brass hard drawn hooks and eyes : 200mm
211Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
212Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.:80x1.25 mm M.S. laths with 1.25 mm thicktop cover.
213C/O Septic tank and soak pit for proposed 33/11 KV Sub Station
214Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
215Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size)
216Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
217Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
21815mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
219Reinforced cement concrete work in beams, suspended floors, roofs havingslope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plainwindow sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size).
220Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars
221Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.
222Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A,including jointing with seal ring conforming to IS : 5382,leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
223Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised RigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion..-110 mm dia.
224Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. :- 110 mm
225Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
226Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
227Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominalsize), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
228Inside size 90x80 cm and 45 cm deepincluding C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (nonmodular) bricks of class designation 7.5
229Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid,10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
230Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with single 15 mm C.P. brass pillar taps
231Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
232Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250
233Providing and fixing brass bib cock of approved quality :-15 mm nominal bore
234Providing and fixing brass stop cock of approved quality:15 mm nominal bore
235Providing and fixing uplasticised PVC connection pipe with brass unions : :- 45 cmlength-15 mm nominal bore
236Providing and fixing PVC water storage tankofISI : 12701 marked,G.I. inlet and outlet connection, 15mm nominal bore ball valve and mosquito proof PVC cover with locking arrangementincluding hoisting upto allheights above ground level :-1000 litres net capacity tank
237Providing and fixing cast iron floor trap of self cleaning desion with sand cast iron screwed down or hinged grating with out vent arn complete including cost of cutting and making goods the walls and floors :- 100mm nominaldiameter
238Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore
239Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :l:-25mm nominal bor
240Providing and fixing 600mm x 450 mm bevelled edge miror of superior glass mounted on 6mm thick A.C. Sheet or plywood sheet and fixed to wooden plugs with C.P. Brass screws and washers.
241Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than106 gms.
242Providing and fixingjet spray of approved quality and colour with one metre tube.
243Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
244Providing EI wiring in Control Room Building for proposed 33/11 KV Sub Station
245Wiring for light point / fanpoint /exhaust fan /call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
246Group-C
247Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required.
248Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
249Supplying and fixing electrical switch board, having 3 No. of 5 amp. switches and socket on suitable size of metal box ofmm deep 6 modules(205mmx78mmx50mm on surface or in recess with suitable size phenolic laminated sheet cover in the front i/c providing and fixing3 No. 5 pin 5/6 amp socket outlet and 5/6 ampPiano type switch, connection, painting etc.as req.(For light plugs)(Make:-Legrand(Myrius),L&T(Oris),Anchor(Roma Plus).
250Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2512x1.5 Sq. mm.
2522x4.0 Sq. mm.
2532x10 Sq. mm.
254Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulatedheat resistant flame retardant (HRFR) and low smoke singlecore (flexible) copper conductor cable in surface/recessedPVC conduit along with 2 No.16 Sq.mm. (4x16+2x16)HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
255Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
256Supplying and fixingLED panel Recess mounted 12 watts round Panelwith aliminium die cast housingof superior quality ( Jaquar make) as per item code LNRO01R018XC as required complete in all respect and as apporoved by the Engineer-in -Charge. Make- Jaquar, Philips, K-lite ,Anchor Panasonic having power factor >.9,Efficacy >100 lumens/watt,THD <10,CRI >80 with 3 years warranty..
257Supplyinganderection of 6amps. to 32 amps. rating, 10 KA breaking capacity, 240volts, \"C\" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Single pole. Cat-A.
258Supplyinganderection of 40/50/63 amps rating, 10 KA breaking capacity, 240volts, \"C\" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Double pole Cat-A.
259Supplyingand fixingoffollowingway, singlepoleandneutral sheetsteel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Double door-8 way
260Providing installationtesting and commissioning of ceiling fan with regulator including twiring the down rod of standard length (up to 30cm0WITH 16/0.20mm twin twisted flexiblecotton braided copper ccotten braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required.Ceiling Fan 1400 mm sweep, Category-A
261Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
262Exhaust Fan, Light duty, (Domestic) 300 mm sweep
263Exhaust Fan, Heavy duty, 300 mm sweep
264Providing, Installation, testing and commissioning ofGlazed LED 36 Watt Batten High quality design aluminum extruded decorative end caps Make: Crompton, philips, Jaquar, or as approved by Engineer in charge.
265Providing and fixing TP&N switch disconnector fuse unit cubical type, 415/500 volts with 3 No. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the bodyetc. as required.32 Amp
266Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacitywith 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
267Providing, Installation, testing and commissioning of wall fanSweep size (mm) 400 mm,3 No. of blades, Air delivery (cmm) 95, Speed of 2000 RPM, Oscillation 60 °, Adjustable upward and downward tilt mechanismas required. Make:- Havells
268Providing,installation,testing and commissioning of LED Mirror Light 10 wattLEDC omplete with connection etc. as required. Make- philips, panasonic or as approved by engineer in charge.
269Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
270Supplying and fixing LED street light 25 Watts,LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP65 protection and impact resistance of IK07, Havells make having Ordering code LHETBXU7PA6S025complete with connections, testing, commisioning etc as required. Havells, Philips, K-lite.
271R.S. Joist Foundation
272Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
273Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size)
274Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size)
275Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars.
276Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

AI Tender Summary

OUR REF NO 30586616
AUTHORITY Government Departments
TENDER VALUE 1.52 Crore
LAST DATE 12-01-2022
Authority
Authority Name Himachal Pradesh State Electricity Board
Work Description Hpsebl/Ceocz/Mm/Nit -23/2021 Survey Design Erection Testing And Commissioning Of 33/11 Kv Stn 1X3.15 Mva At Samila Including Civil Work And Terminal Equipments At Khudle End In Esd Baldwara Ed Sarkaghat Under Operation Circle Hpsebl Mandi
Basic Detail
Tender No HPSEBL/CEOCZ/MM/NIT-23/2021-22
Bidding Type Tender
Location
City sarkaghat
State Himachal Pradesh
Key Dates
Publish Date 05 Jan 2022
Submission Date 12 Jan 2022
Open Date 13 Jan 2022
Finance
Tender Value 1.52 Crore
Tender Fee 2360
EMD 1.52 Lakhs
Exemption Not Available
Document List
5128eece-15e9-4c36-87d6-7c8b0306ef9e.html
BOQ_83083.xls
NIT.pdf
SBD.rar
technocomsheets.xls
TechSpc.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 05, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 12, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 13, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5128eece-15e9-4c36-87d6-7c8b0306ef9e.html

xls

BOQ_83083.xls

pdf

NIT.pdf

rar

SBD.rar

xls

technocomsheets.xls

rar

TechSpc.rar

pdf

Tendernotice_1.pdf

Disclaimer