Supply Of Electrical Equipments 2022 -1 Dual Channel 30 V, 2 A Continuously Variable Dc Regulated Power Supply With Current And Overload Protection 2 Single Phase Transformer 230 / 230V, 2Kva With Standard Tappings On Primary And Secondary Windings 3 Portable Moving Coil Analog Dc Voltmeters A ) 0 - 1 V B ) 0 - 10 V C ) 0 - 30 V 4 Dc Digital Voltmeters A ) 0 - 1 V B ) 0 - 10 V C ) 0 - 30 V 5 Portable Moving Iron Ac Voltmeters A ) 0 - 300 V B ) 0 - 600 V 6 Portable Moving Coil Dc Ammeters A ) 0 - 100 Ma B ) 0 - 1 A C ) 0 - 2 A 7 Portable Moving Iron Analog Ac Ammeters A ) 0 - 2 A B ) 0 - 5 A C ) 0 - 10 A 8 Portable Digital Ac Ammeters A ) 0 - 2 A B ) 0 - 5 A C ) 0 - 10 A 9 Watt-Meters A ) 150 / 300V, 2 A, Upf B ) 300 / 600 V, 5 / 10 A, Lpf For Measurent Of Low Pf For Inductive Load 10 Rheostats – 25 Ohms, 50 Ohms, 150 Ohms, 220 Ohms ( All Rated At 3 A ) 11 Rheostat Loads – 1 Kw, 230 V 12 Soldering Iron 60 W 13 Single Phase Energy Meter 10 A, 230 V, 50 Hz, Digital Type 14 Multi-Meter Digital ¾” 15 Dual Trace Oscilloscope – 30 Mhz Operating Modes: Channel 1, Channel 2, Channel 1 & 2 Alternate Or Chopped ( Approximately 350Khz ) , X - Y ( Ratio 1:1 Input Via Ch2 ) , Add / Sub Ch1± Ch2, Invert Ch2 Rise Time: 12Ns ( Approximately ) . Vertical Deflection ( Y ) : ( Identical Channels ) Bandwidth: Dc - 30Mhz ( -3Db ) .Maximum Input Voltage: 400V ( Dc+ Peak Ac ) . Sensitivity: Internal 5Mm, External 0.8V ( Approximately ) .Power Consumption: 45Va Display: 8 X 10Cm Trace Rotation: Adjustable On Front Panel Calibrator: Square Wave Generator 1Khz ( Approximately ) , 0.2Vpp ± 1% For Probe Compensationdeflection Coefficients: Micro-Controller Based 12 Calibrated Steps 5 Mv / Div–20 V / Div ( 1-2-5 Sequence ) . Electronic Control Display On 32 Character Backlit Alphanumeric Lcd. Accuracy: ± 3% Input Impedance: 1M | | 30Pf ( Approximately ) 16 Three Phase Induction Motors :1 Hp – 440 V 50 Hz. 17 Three Phase Induction Motors :2 Hp – 440 V 50 Hz. 18 Three Phase Dol Starter - 440V, ----Suitable For 1Hp Or 2 Hp Motor 19 Star-Delta Starter 3 Phase-440V, 3 Phase, 0- 440V----Suitable For 1Hp Or 2 Hp Motor 20 Auto Transformer Starter 3 Phase, 0- 440V----Suitable For 1Hp Or 2 Hp Motor 21 Ups 1Kvatechnology:True On-Line Ups With Double Conversion Technology Rectifier & Inverter Both Be Igbt Based Power Rating 1000Va / 800W Input Voltage & Range 160-280 Vac @100% Load Input Freq. Range 45Hz ~ 55 Hz Input Power Factor >=0.95 Output Voltage Range 220 / 230 / 240 Vac ±3% Protection Internal / External Transient Voltage Surge Suppressor At I / P Of Ups Transient Response :Less Or Equal To 3% For 100% Nonlinear Load ( Battery Mode ) Led Display Ups Status, Load Level, Battery Level, I / P O / P Voltage, Discharge Timer And Fault Conditions Trigger System: Modes: Auto / Level Source: Ch1, Ch2, Alt Ch1 / Ch2, External. Slope: Positive Or Negative Coupling: Ac 22 Battery Lead-Acid Type, 140 A-Hr And Hydrometers 23 Meggar Hand Driven, 1000V, 1000 Mω 24 Digital I C Trainer Kit, 5V 1A Fixed Dc, ± 12V Fixed Dc, O / P Current 1A, Regulation ±0.1% Fixed & Variable Clock Generator 25 Function Generator 9Khz- 3Ghz, Frequency Resolution 0.1 Hz, Reverse Power Protection 2Watt, Minimum Output Level -120 Dbm Maximum Output Level +13 Dbm 26 Wooden Wiring Board ( 2X3 ) Ft 27 Single Phase Resistive Load 10A Variable In Steps Of 1A 28 Electronic Components A ) Step Down Transformer 230 / 24 V, 12 Ma B ) Relays – Solid State Sugar Cube Type, Spst, Coil 6V, Power Circuit 230 V, 5 A. C ) Bread Boards D ) Tag Boards. 29 Proximity Sensor Test Kit / 30 Simple Panel Board / Cubical Consisting Of Bus-Bars, Cb / Mcb / Elcb, Meters, Hrc Fuses, Magnetic Contactors, Cables, Earthing Points.