Water Supply Scheme Under Jjm In The Year 2021-22 / Construction . Of 6.00 Mtr. Dia. Masonry Well And Providing, Laying Pvc Distribution Line In / C Allied Works At Tingaria Under Indurail Vc Within The Jurisdiction Of Dws Sub-Division, Panisagar
Tender Overview
Project Description
Water Supply Scheme Under Jjm In The Year 2021-22 / Construction . Of 6.00 Mtr. Dia. Masonry Well And Providing, Laying Pvc Distribution Line In / C Allied Works At Tingaria Under Indurail Vc Within The Jurisdiction Of Dws Sub-Division, Panisagar - Gr-Ii
BOQ
| Sl. No. | Item Description |
| 1 | A) Earth Work |
| 2 | Earthwork in excavation for structures as per drawing and MoRT&H technical specifications Clause 304 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. |
| 3 | I) Ordinary Soil |
| 4 | A) By Manual Means |
| 5 | I) Upto 3 m depth |
| 6 | ii) 3 m to 6 m depth |
| 7 | iii)above 6 m depth |
| 8 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil. |
| 9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil cum |
| 10 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 11 | B) Cement Concrete Work |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: |
| 13 | i) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 14 | C) Reinforced Cement Concrete Work |
| 15 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement |
| 16 | -All work upto plinth level: |
| 17 | i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 18 | ii)1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement |
| 20 | 5.3.2.2) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 21 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement |
| 22 | 5.2.2) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 23 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete uptoplinth level. |
| 24 | 5.20.4) Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars |
| 25 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 26 | 5.9.5.1) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 27 | 5.9.6.2) Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 28 | First class brick work in foundation and plinth including cost of all materials as required complete |
| 29 | 6.1.3)In cement mortar 1:4 ( 1 cement :4 fine sand). |
| 30 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete |
| 31 | 6.3.3)In cement mortar 1:4 ( 1 cement : 4 fine sand) |
| 32 | D) Finishing Work |
| 33 | 12 mm cement plaster of mix |
| 34 | 12.1.2) In cement mortar 1 : 4 (1 cement : 4 fine sand) |
| 35 | Extra for plastering on circular work not exceeding 6 m in radius complete. |
| 36 | i)In one coat |
| 37 | 6 mm cement plaster of mix : |
| 38 | 12.4.1) In cement mortar 1 : 3 (1 cement : 3 fine sand) |
| 39 | Neat cement punning. |
| 40 | F) PumpMotor installation |
| 41 | Providing & Lowering ofsubmerssible pumpof 45 mtr. head with suitable single phase submerssiblemotorin/c additional32 mtr. submerssible 3 core copper flat cable (2.5 mm size) along with 40 mm gi pipe ( medium class) both end welded with each column pipe in 3 mtrertion 900 G.I single end flange bendG.I flange short piceG.I. tailpiceand 100 mm dia C.I. non-returnvalve etc complete in respect as per direction of the engineer in charge. |
| 42 | a) 2000 GPH capacity submerssible pump with 3 HP submerssibleMotor. |
| 43 | Supplying and fitting fixingof B 13 ( size width 450mmXlength 1200mmX height 850mm) fittedwith 4 nossuportt of 75 mm X 75mm( 6mm thick) M.S. anglefor embedding in 1:2:4 cement concretebase ( size 300 mm X 300 mm dia X600 mm) with proper locking arrangement and coated with anti corrosive main switch energy metter etc complete in all respect as per derection of the Engineer in charge. |
| 44 | Supplying and fitting fixing single phase motor starter unit( with 2 pole contactor, overload relay , volty metre& amps metter) 32 amps main switch(| 220 volt) of hecvels/BCH/L&T make in KILOSK in/c necessary elctric wiring and G.I. pipe earthing etc complete as per direction of the Engineer in charge i).For 3 Hp Submersible motor. |
| 45 | Providing and fitting fixing with PVC insulated 3 coreflat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge. |
| 46 | i. 2.50 sqmm |
| 47 | Trial run and commissioning of the samein all respect as per direction of the engineeri-in - Charge. |
| 48 | E) Laying of Pipeline |
| 49 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm(slope-1 in 200) including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. |
| 50 | A). For UPVC pipes in new work |
| 51 | a). In all kinds of soil |
| 52 | i). For pipes not exceeding 90 mm dia |
| 53 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in charge.A) External work. |
| 54 | i. 40 mm dia. nominal bore |
| 55 | ii. 80 mm dia. nominal bore |
| 56 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cementconforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as perCPWD specification and direction of the Engineer - in - charge. |
| 57 | A.Class - 3 ( working pressure 6.0 kg / cm2) |
| 58 | i)40 mm OD |
| 59 | ii)50 mmOD |
| 60 | iii) 90 mm OD |
| 61 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. |
| 62 | i)50 mm dia A. PN - 1.0 |
| 63 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 64 | a) 15 mm dia. |
| 65 | b) 40 mm dia |
| 66 | c) 50 mm dia. |
| 67 | b) 80 mm dia. |
| 68 | Providing and fixing G.I. equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 69 | a) 40 x 40 x 40 mm dia. |
| 70 | b) 50 x 50 x 50 mm dia. |
| 71 | c) 80 x 80 x 80 mm dia |
| 72 | Providing and fixing G.I. Unequal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 73 | ii) 50x50x15 mm dia |
| 74 | iii) 40x40x15 mm dia |
| 75 | iv) 80 x 80 x15 mm dia |
| 76 | Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 77 | a) 50 x 40 mm dia. |
| 78 | b) 80 x 50 mm dia |
| 79 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge. |
| 80 | iii) 15 mm dia |
| 81 | i) 40 mm dia |
| 82 | ii) 50 mm dia |
| 83 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. |
| 84 | i) 15 mm dia |
| 85 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge. |
| 86 | B). by manual means |
| 87 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direction of the Engineer - in - charge (cost of earth work and fittings will be paid separately). |
| 88 | a) 15mm dia |
| 89 | Providing and fixing brass ferrule with C.I. cover conforming to IS :2692 including boring and tapping the main as per chapter 20 of CPWD specification and direction of the Engineer - in - charge. |
| 90 | i. 10 mm nominal bore |
| 91 | ii.15 mm nominal bore |
| 92 | Providing and fixing in position Precast RCC hydrant post engraved with logo of JJM and other necessary details of size 150 x 150 mm at the bottom & 150 x 150 mm at the top and 1500 mm Long ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 stone aggregate of 10 mm nominal size) and steel reinforcement ( TMT bars ) 8 mm dia 1200 mm long 4 nos and 8 mm dia stirrup 11 Nos ), 300 mm shall be kept below ground level , embedding the same with in 500 x 500 x 500 mm cement concrete 1 : 5 : 10 ( 1 cement : 5 sand : 10 Stone aggregate of 40 mm nominal size ) as per approved drawing, including plastering the exposed surface with 6 mm thick cement mortar 1 : 4 ( 1 cement: 4 sand ) finished with a floating coat of neat cement ) including providing & embedding 15 mm dia G.I. pipe (medium class) 1250 mm long with necessary GI fittings like elbow 2 Nos, socket 1 no, nipple 300 mm long 1 no, union 1 no etc. and fitting fixing of CI long handle bib cock by welding with GI socket complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge. |
| 93 | Providing and fixing in position Precast RCC platform of size 1100 x 1100 mm x 100 mm with curb of size 50 x 50 mm keeping an opening of 100 mm long in a suitable place for draining out of water ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 brick aggregate 1st class 20 mm nominal size) and steel reinforcement ( TMT bars ) 8 Nos, 8 mm dia in both direction including plastering the exposed surface with 12 mm thick cement mortar 1 : 3 ( 1 cement: 3 sand ) finished with a floating coat of neat cement ) complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge. |
| 94 | Constructing masonry Chamber 90 x 90 x 100 cm, inside with brick work in cement mortar 1 : 4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1 : 2 : 4 mix ( 1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design, CPWD specification and direction of the Engineer - in - charge. |
| 95 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-chargei. 15 mm dia PVC /plastic bib cock |
| 96 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in charge |
| 97 | i. 40 mm dia |
| 98 | ii. 50 mm dia |
| 99 | F) Miscilenious Work |
| 100 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil |
| 101 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 102 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: |
| 103 | i)1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size). |
| 104 | Providing structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required |
| 105 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or weight not less than 7.75 Kg per sqm including 25X5mm Flat beading |
| 106 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: 12.47.1 Two or more coats on new work |
| 107 | G) Miscilenious Work |
| 108 | Providing & laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8. |
| 109 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittingsincluding trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.A). External work.vi). 50 mm dia. nominal bore |
| 110 | Providing fitting fixing 150 mm dia pulley for lifting of water in/c necessary welding, clamping etc. as per direction of the Engineer-in-Charge. |
| 111 | Constructionofsurface drain 250 mm. wide, 150 mm.deepand125 mm. side walls with 2nd classbrick masonry work 1:4(1 cement: 4 river sand) on100 mm. thick cement concrete bed of mix 1:5:10(1 cement:5river sand: 10 jhama aggregate 40 mm. nominalgauge)and cement concrete 1:2:4 mix (1cement: 2 river sand sand: 4 jhama aggregate 12.5mm.nominal gauge) in drains including finishing with12 mm. thick cement plaster 1:3(1 cement: 3 riversand)with a floating coat of neat cement finishcompleteasperstandard design (Earth work to be paid separately) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender