Military Engineer Services-MES has published Repair And Maint Of Fire Fighting Equipment Installed At Hq Swc Bldg At Jaipur Mil Stn Repair And Maint Of Fire Fighting Equipment Installed At Hq Swc Bldg At Jaipur Mil Stn. Submission Date for this Tender is 30-01-2022. Fire Fighting Service Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 23-Jan-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-01-2022 |
Sl. No. | Item Description |
1 | M & L for dismantling of centrifugal/Jockey/Terrace pump set of capacity upto 10 HP 3 phase, 415 volts, 50Hz, AC supplyafter disconnecting electric connection including repairing/ replacing defective parts worn out nuts, bolts, washers, terminal box, ball bearings, impeller, air release valve, gasket and gland packingto arrest the leakage frompump, oiling and greasing etc complete cleaning, painting of pump and motor with two coats of synthetic enamelled paint after applying one coat of red oxide primer and reassembling in position, testing, commissioning and connecting to pipe line complete all as specified and directed. Note :- Spare part/components shall be measured and paid separately. |
2 | Supply only ball bearing as per existing make. |
3 | Supply only stainless steel pumpshaft. |
4 | Supply only gun metal impeller with neck key and distance bush. |
5 | Supply only coupling with cover as per existing. |
6 | Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of existing size and class of insulation including insulation paper, sleeves, thimbles etc complete all as specified and directed. |
7 | M & L for dismantling of centrifugal/Jockey/Terrace pump set of capacity upto 20 HP 3 phase, 415 volts, 50Hz, AC supplyafter disconnecting electric connection including repairing/ replacing defective parts worn out nuts, bolts, washers, terminal box, ball bearings, impeller, air release valve, gasket and gland packingto arrest the leakage frompump, oiling and greasing etc complete cleaning, painting of pump and motor with two coats of synthetic enamelled paint after applying one coat of red oxide primer and reassembling in position, testing, commissioning and connecting to pipe line complete all as specified and directed. Note :- Spare part/components shall be measured and paid separately. |
8 | Supply only ball bearing as per existing make. |
9 | Supply only stainless steel pumpshaft. |
10 | Supply only gun metal impeller with neck key and distance bush. |
11 | Supply only coupling with cover as per existing. |
12 | Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of existing size and class of insulation including insulation paper, sleeves, thimbles etc complete all as specified and directed. |
13 | M & L for dismantling of Electric driven Fire pump/Diesel engine driven pump (centrifugal pump) set of capacity upto 75 HP 3 phase, 415 volts, 50Hz, AC supplyafter disconnecting electric connection including repairing/ replacing defective parts worn out nuts, bolts, washers, terminal box, ball bearings, impeller, air release valve, gasket and gland packingto arrest the leakage frompump, oiling and greasing etc complete cleaning, painting of pump and motor with two coats of synthetic enamelled paint after applying one coat of red oxide primer and reassembling in position, testing, commissioning and connecting to pipe line complete all as specified and directed. Note :- Spare part/components shall be measured and paid separately. |
14 | Supply only ball bearing as per existing make. |
15 | Supply only stainless steel pumpshaft. |
16 | Supply only gun metal impeller with neck key and distance bush. |
17 | Supply only coupling with cover as per existing. |
18 | Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc complete all as specified and directed. |
19 | Supply & fix in repair of fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290. (Make: Newage or equivalent as approved by GE.) |
20 | Supply & fix in repair of fire hydrant landing valve type B (double head outlet) of 63 mm dia conforming to IS 5290. (Make: Newage or equivalent as approved by GE.) |
21 | Supply and fix in repair of hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe,nozzle, coupling etc of MS sheet of thickness 2.0 mm Complete all as specified and directed. |
22 | Supply and fix in repair of 63 mm dia gun metal short branch pipe with 20 mm dia gun mental nozzle conforming to IS 903. |
23 | Supply and fix in repair of hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle, MS sheet 2 mm thickness confirming to IS -884. |
24 | Supply and fix in repair of rubber hose reel of 20 mm dia and 30 meter length conforming to IS 5132 |
25 | Supply and fix in repair of branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 |
26 | Supply and fix in repair of 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 |
27 | Supply and fix in repair of fire hydrant stand post with provn of single outlet conforming to IS 908 |
28 | Supply and fix in repair of weather proof hose cabinate made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4mm thick glass & door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard and locking arrangement, MS legs grouted in PCC (1:2:4) type B-1 suitable to accomodate two nos 15m long fire hose pipe and one no first aid hose real 30m long & short branch pipe and mounted on masonry platform complete all as specified and directed. |
29 | Supply and fix in repair MS pipe of size 150 mm bore with wall thickness 6.35 mm heavy duty class "C" as per IS-1239, part-I (heavy duty) for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer including cutting, welding, etc complete with fittings such as flanges, Tees, Elbows, bends, junctions, reucers etc welding wherever required as per standard practice including jointing pipes with welded joints and laid in trenches/wall including necessary protection against corossion by means of coating and wraping coating with PYPKOE 4mm thick anticorrosive tape as per IS-10221 complete all as directed and as specified. |
30 | All as item no 14 here-in-before but of size 100 mm bore with wall thickness 6.35 mm |
31 | All as item no 14 here-in-before but of size 80 mm borewith wall thickness 6.35 mm |
32 | Supply and fix in repair MS black pipe of size 100mm bore, 4-8mm wall thickness as per IS 1239 (Part -I) heavy grade including cutting , welding etc, including painting with one coat of primer and two coat of synthetic enameled paint complete all as specified and directed. |
33 | All as item no 15 here-in-before but of size 80 mm bore |
34 | All as item no 15 here-in-before but of size 65 mm bore |
35 | All as item no 15 here-in-before but of size 50 mm bore |
36 | All as item no 15 here-in-before but of size 40 mm bore |
37 | All as item no 15 here-in-before but of size 32 mm bore |
38 | All as item no 15 here-in-before but of size 25 mm bore |
39 | Supply and fix in repair Sluice valve of size 200 mm bore ISI Marked classPN 1.6 flanged type with cast iron body and drilled spindle including flanged joint with 3 mm thick rubber gasket including necessary bolts and nuts complete all as specified and directed. |
40 | All as item no 16 here-in-before but of size 150 mm bore |
41 | All as item no 16 here-in-before but of size 100 mm bore |
42 | All as item no 16 here-in-before but of size 80 mm bore |
43 | Supply and fix in repair existingHose reel drum 30m complete all as specified and directed. |
44 | Supply and fix in repair existing Strainer for Suction for 150mm dia. |
45 | Supply and fix in repair non return valves of class PN 1.0 of dual platetype and size 150 mmwith cast iron bodyand both ends flanged, IS-14846 marked comlete with neoprene rubber gasket ,jointing material and incl nuts,bolts,washer of suitable size etc complete all as specified and directed. |
46 | All as item no 19 here-in-before but of size 100 mm dia |
47 | Supply and fix in repair of CI foot valve of size 150 mm dia Ball type NRV ISI marked with all fittings complete. |
48 | All as item no 21 here-in-before but of size 100 mm dia. |
49 | Supply and fix in repair Pressure gauge 4"dial 0-21 kgs rating complete all as specified and directed. |
50 | Supply and fix in repair CI Flanged stand post CI 80mm dia 1.5m height complete all as specified and directed. |
51 | Supply and fix in repair Pressure switch Universal type complete all as specified and directed. |
52 | Supply and fix in repair Flow switch 100mm dia complete all as specified and directed. |
53 | Supply and fix in repair Pipe Support of Mild steel viz. hangars, fastners, elbows, supports, tees complete all as specified and directed. |
54 | Supply and fix in repair Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric, optical with base with self built intelligence as per IS: 11360 |
55 | Supply and fix in repair of detectors Complying with and type certified to EN - 45 Addressable type heat detector with base with rate of rise cum fixed temperature as per lS:2175 |
56 | Supply and fix in repairfor Fire Alarm sounders / Sirens electronic type horizontal two stage continuous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5 db 1000m range. |
57 | Supply and fix in repair Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories. |
58 | Supply and fix in repair of Gun metal fire brigade inlet connection (suction collecting head) consisting of four nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia sluice valve (one no 150mm dia NRV), and 150mm dia flanged outlet complete with all accessories. |
59 | Supply and fix in repairAir cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete |
60 | Supply and fix in repair Automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete |
61 | Supply and fix in repairBulb type gun metal sprinkler head pendent type set to operate at 68 degree C |
62 | Supply and fix in repair Bulb type gun metal sprinkler head upright type set to operate at 68 degree C |
63 | Supply and fix in repair Bulb type gun metal sprinkler head concealed type set to operate at 68 degree C |
64 | M&L for disconnectingpower from main supply of panel and dismantling, repair and replacement of unserviceable part with oiling,greasing and re-wiring of the complete panel main switch to starter and connected accessories withcopper conductor PVC insulated wire of existing suitable size (upto 25 sqmm and maximum 20 mtr) including cable lugs complete all as specified and directed. |
65 | Supply & fixin repair for contactor of capacity 60 Amp ,4 pole,type CN5 40F as per existing complete all as specified and directed. (Make:- Schneider or equivalent as approved by GE.) |
66 | Supply & fixin repair electronic timer as per existing.(Make:- Legrand or equivalent as approved by GE.) |
67 | Supply & fix in repair for contactor of capacity 100 Amp,3 pole ,type CH1 115T as per existing complete all as specified and directed. (Make:- Havells, Schneider or equivalent as approved by GE.) |
68 | Supply & fixin repair single phase preventor for the motors upto capacity 75 HP as per existing complete all as specified and directed.(Make:- Havells, Schneideror equivalent as approved by GE.) |
69 | Supply & fix in repair ampere meter with CTs of range 0-30 amps as per existing complete all as specified and directed. |
70 | Supply & fix in repair voltmeter with PTs of range 0-500 volts as per existing complete all as specified and directed. |
71 | Supply & fixin repair selector switch for voltmeter/ampere meter as per existing.(Make- AE or equivalent as approved by GE.) |
72 | Supply & fixin repair over load relay coil 37-50 Amp, 230 volts type RT23V as per existing complete all as specified and directed. (Make:- L&T,Havells,Schneider or equivalent as approved by GE) |
73 | Supply & fixin replacementMCB TP of capacity 20-63 amps, rating 1 KA415 volts as per existing complete all as specified and directed. (Make:- L&T,Havells,Schneider or equivalent as approved by GE) |
74 | Supply and fix in repair MCCB TPN 63 Amp (DPX3 160), 415 volts, 50 Hz 25KA complete all as specified and directed. |
75 | Supply and fix in repair MCCB TPN 125 Amp (DPX3 160), 415 volts, 50 Hz 35KA complete all as specified and directed. |
76 | Supply and fix in repair MCCB TPN 250 Amp (DPX3 250), 415 volts, 50 Hz 35KA complete all as specified and directed. |
77 | Supply and fix in repair Sprinkler quick/early response type as per IS-15105/TAC guidelines 68 degree temperature rating complete all as specified and directed. |
78 | Supply and fix in repair Sprinkler rosette 25 mm dia complete all as specified and directed. |
79 | Supply and fix in repair of analogue addressable intelligence multi sensor detector with photo thermal both (Optical and thermal) as per NFPA style 7 wiring complete with base. |
80 | Repairing of 32 bit microprocessor based loop fire alarm control panel of make:- Notifier, fully networkable, expandable with each loop capable of taking not less than 252 detector and devices expandable with 6" LCD touch screen or 640 character alpha-numeric liquid crystal displays. Note:- Above quoted rate shall inclusive of replacement of any defective/unserviceable part of fire alarm control panel. No extra payment shall be admissible on this account. |
81 | Supply and fix in repair 2 core, 1.5 sq mm flame retardant low smoke, PVC insulated unsheathed flexible bright annealed copper conductor cable, 1100 volts grade. |
82 | Supply and fix in repair remote response indicator complete all as specified and directed. |
83 | Supply and fix in repair Addressable manuals call points push type complete all as specified and directed.(Annunciating drive) |
84 | Supply and fix in repair short circuit isolators complete all as specified and directed. |
85 | Supply and fix in repair 2 W speaker (Ceiling mounted) complete including necessary wiring complete all as specified and directed. |
86 | Checking serviciablity of fire fighting and fire alarm system and demostration (mock drill) by authorised company representative, providing detailed report of entire fire fighting and fire alarm system each floor and wing wiseincluding checking serviciablity of electric driven fire pump, diesel engine, engine driven pump, fire alarm panel, fire siren/ hooters, heat/smoke detectors, all type of sprinklers, valves, distribution lines, hose reals, external distribution lines etc complete fire fiting system as per ground condition complete all as directed by Engr in Charge. |
87 | Schedule of Credit |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy