Public Administrative Department Trust & NGO Closing in 0 days TDR #30557210

Electrical Work Of Multipurpose Veterinary Hospital And Polyclinic At Nathuwas Electrical Work Of Multipurpose Veterinary Hospital And Polyclinic At Nathuwas

Issued by Trust & NGO · nathdwara, Rajasthan
Tender Value
57.20 Lakhs
Estimated cost
Bid Submission
24 Jan 2022
0 days left
EMD
1.14 Lakhs
Bank guarantee accepted
Document Fee
1190
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
nathdwara → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Electrical Work Of Multipurpose Veterinary Hospital And Polyclinic At Nathuwas Electrical Work Of Multipurpose Veterinary Hospital And Polyclinic At Nathuwas

BOQ

Name of Work: Electrical workof multipurpose veterinary hospital and polyclinic at Nathuwas,Nathdwara
Sl. No. Item Description
1Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Short point (up to 3 mtr.)
2Medium point (up to 6 mtr.)
3Long point (up to 10 mtr..)
4Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles, 18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modular switch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . On board
5Medium point (up to 6 mtr.)
6Long point (up to 10 mtr..)
7Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
8Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 2 pin Telephone socket
916 A 6 pin shuttered socket
105 step fan regulator 2 Module
11Blanking plate
12Modular MCB 6 A to 32 A DP (IS:8832 marked)
13Providing & Fixing of following size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR 1/2 Module
14Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .1-2 Module
15Supplying and drawing FR PVC insulated & unsheathedflexible copper conductor as per PWD specification forelectrical Works with ISI marked (IS:694) and as per IS8130 : 2013 of 1.1 kV grade . Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC60228 for lower watt loss , oxygen free ( <10 ppm) forless chances of oxidization and higher silver content forgives better conductivity , insulation PVC type A ,flameretardant as per IS 10810-53, better amperage rating asper VDE 0298 part 4, , in existing surface or recessedPVC/ MS conduit/casing capping including all as per preapproved by Engineer in charge,making connections, etc.as required. OEM Must have its own in house NABL labsetup for all testing facilities for wires. For additionaltechnical parameters of products/ work , refer Annexure\"A\" attached with this BSR .1 x 1.5 sq.mm
162 x 2.5 sq. mm. + 1x1.5sqmm
172 x 4.0 sq. mm. + 1 x 2.5 sq. mm
182 x 6.0 sq. mm. + 1 x 2.5 sq. mm
194 x 6.0 sq.mm
201 x 10.0 sq.mm
214 x 10.0 sq.mm
221 x 4.0 Sq.mm.
23Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire ofsuitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure\"A\" attached with this BSR .IP-43 (Three phase)Double Door. 4 Way (12 O/G + 8 I/C)
246 Way (18 O/G + 8 I/C)
258 Way (24 O/G + 8 I/C)
26IP-43Double Door ( Single phase) 12 Way (12 O/G +2 I/C)
27Providing & Fixing of recessed/surface mounting heavy duty sheet steel 1.6 mm thick End Box as per PWD specification for electrical Works for distribution board duly phophatised powder coated complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 4 way DB
286 way DB
29Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and siterequirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with thisBSR . 6 A to 32 A rating 1 pole MCB
30Four pole MCB 40-63 A rating
31Double pole MCB 6Amp to 32 Amp Reting
3240 A rating
33Triple pole MCB 6 A to 32 A rating
3440 A rating
35S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recessincluding cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submittedbefore execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .20 mm
3625 mm
3732 mm
3840 mm
39Making of hole in wall (brick/stone) of required size for housing exhaust fan and making good the same, with cement plaster as required of following size: Up to 457 mm size
40P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All asper pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
41Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electricalWorks, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .300 mm sweep(900/1400 RPM)
42Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy = 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.=0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. 4\" LED Tube shape fixture 18/20 W (Polycarbonate Base)
43Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electricalWorks, conforming to IS:374-2019, & IS:1885 -P-V1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductormaking connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
44Providing & Fixing of capacitor start, copper wound, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 400 mm sweep(Oscillating type)
45Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 300 mm sweep
46Providing & Laying P.V.C./XLPE insulated & P.V.C.sheathed Un-armoured/Armoured aluminium cable of 1.1KV grade as per PWDspecification for electrical Works in existing RCC/Hume/Stoneware/PVCpipe/openduct/cable trench with filling of excavated earth in trench,on existing cable trays or on surface etc.including making necessary connection, testing etc. asrequired of size and asperpoints(a),(b),(c),mentioned below:-(a)Material:-H4-Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130,IS3975-1999 for armouring of cables in armoured cable items,IS5831 for sheath,IS10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO9001&14001 certifications for quality assuarance &its own in house NABL lab set up for all testing facilities for cables. Appropriate type test certificate/OEM test report shall be submitted. Allabove as per pre approvedby Engineerincharge. Foradditionaltechnicalparametersofproducts/work,referAnnexure\"A\"attached with this BSR . Armored Cable. 95.0 Sq. mm x3 .5 core
47120.0 Sq. mm x3 .5 core
48185.0 Sq. mm x 3.5 core
4910.0 Sq. mm 4 core
5050.0 Sq. mm 3.5 core
5170.0 Sq. mm 3.5 core
5216.00 Sq mm.x 4core
5310 sq. mm x 2core
54SITC of chemical Gel earthing systemof Dual Pipe Technology made of with\"B\"Class GIPipe asperIS1239(part- ):2004 of Medium duty off ollowing sizes asper points mentioned(a),(b),[c), (d), (e) below :- (a)filled with anticorrosive conductive compounds with the permanent sealings at both theends, CPRI/ERDA tested with RMS capacity o fminimum35-40KAfor withstanding 1 second (b)To ensure the moisture content and electricalconductivity, 25kg for 2000mm&50Kgs for 3000mm of resistance lower in gearthen han cement material shall be used as a backfill compound. The compound shall betested form NABL acredeated lab for low resistivity(lessthan0.12Ohm-meter) & high conductivity in nature with carbon asa major content as perreferance of IS3043-1987,IEEE80-2013(clause14.5d) ,IEEE837 & IER 1956 with latest amendemnts©Heavy duty weatherproo fpoly-propylene earth pit chamber with lockable Jamfreelid suitable for safe workingload 5000Kg or more of sizeTop Dia.225to260mm,BottomDia300to350mm. and Height 250 to 300 mm. GIpipe2000mmlong,50/25mm,Terminal40mmx6mmGI Strip
55Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .8 SWG copper Wire
56Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) 70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced LED Street Light fixture 45 Watt
57LED Street Light fixture 100 Watt
58P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .Up to 380 mm size
59Providing & Fixing of Street light bracket made out from following size of \" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 32 mm Dia.
60SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
61160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
62200Amp,35kA,adjustableO/L&fixedS/Csetting,Ics=100 % Icu
63SITC of IP 40 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C and inst. protection setting , True RMS sensing.as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, common fault LED indication, Thermal memory, release trip shall confirm to EMC/ EMI compatability,trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders,etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .With Microprocessor based release 250 Amp , 35 kA, adjustable O/L & AdjustableS/C setting, Ics = 100 % Icu
64400 Amp ,50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu
65Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolyticgrade(Cu-ETP)TinCoatedannealedcopperbusbarsIACS 100% grade
66SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear Thickness of sheet shall not be less than 1.6 mm up to 600 mmlength / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator.
67Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as requiredDigital type
68Providing & Fixing of CT operated direct reading type Ampere meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. G1 Analog type (96mm x 96mm) Digtel type confiring to IEC 62053-21 Below 500A
69Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Red/yellow/Green colour
70Providing&FixingofISOcertifiedcompanymadeselectorswitchof10Aforvoltmeter(4position)usinghighgradeengineeringmaterialtointernationalstandardswithcamassemblyinsulationofglassfilledpolyamidewithhightrackingindex.Forreliableandstableelectricalandmechanicalendurancedoublebuttcontactswithsilverbi-metaloncoppershouldprovided.contactassemblyisofoperatingtemprange-25degreeCto55degreeC,frequencyupto10KHz.switchlifeunderstd.op.conditionsshallbemechanicallyminimum50000operations@300cycles/hourandelectrically10,000operationsat100%rateddutyfor100cycles/hourincludingmakingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,refer Annexure\"A\"attachedwith this BSR .
71Providing&FixingofISOcertifiedcompanymadeCTlinkedselectorswitchof10AforAmperemeter(4position)usinghighgradeengineeringmaterialtointernationalstandardswithcamassemblyinsulationofglassfilledpolyamidewithhightrackingindex.Forreliableandstableelectricalandmechanicalendurancedoublebuttcontactswithsilverbi-metaloncoppershouldprovided.contactassemblyisofoperatingtemprange-25degreeCto55degreeC,frequencyupto10KHz.switchlifeunderstd.op.conditionsshallbemechanicallyminimum50000operations@300cycles/hourandelectrically10,000operationsat100%rateddutyfor100cycles/hour,includingmakingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure \"A\" attached with this BSR .
72Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR250 Amp
73Providing & Fixing of ISI marked (IS:2268-1994) ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
74Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 6 kg
75Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 3.3 KV, 2 mm thick with proof voltage 10 KV / 3 min. and Break Down Voltage 30 KV
76Supply Installation testing & Commissioning of Radial / mixed flow ISI marked water filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of themotor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034:2018 and IS 9283 guideline. The radial flow pumpset shouldoperate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 with required accessories including making connection suitable for Bore well. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, completein all respect . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 3.0 HP, 1-Ø, (7- 95)Mtr, (55-22) LPM
77Providing & Fixing of HDPE pipe ISI mark (IS:4984/2016 ) for water supply (suitable for submersible & jet pump) with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 40 mm OD 6 kg / cm2
78Supply Installation testing & Commissioning of ISO certified company made DOL/Star-Delta Starter panel made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . For single phase Submersible / Monoblock pump 0.5 HP to 3.0 HP (DOL starter)
79Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
80Supply , Installation, Testing and Comissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB.Invertor Type1.5 TR with 3 star rating of BEE (ISEER not less then 3.7 )
81Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
82Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 100 mm dia per running inch length
83Providing & Fixing of ISO Certified company made ISI marked (IS:2082) of 5 star rated vertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloy connection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR 15 Ltr.
84Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 4 KVA
85Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of = 120 lm/Watt ,THD < 10 % , p.f.=0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.Suspended Mounting/Surface Moutning36W LED light fixture 2\"x2\" with acrylic / prismatic front cover.
86Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped & confirming to latest TEC specification , GR / WIR/06-03 March 2002 of following pair in existing surface or recessed PVC/MS conduit/casing capping including all as per pre approved by Engineer in charge, making connections, as required. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 2 pair
8750 Pairs
88Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
89Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessory connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.
90Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSRSingle Aperture .
91Supply, Installation, & Testing of 19\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MTRJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR. 12 Ports
92Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100 MBPS Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
93Supplying and Laying ISI marked P.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .4.0 Sq.mm 3 core flat / Round
94Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 voltgrade as required of size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .4 x 10 sqmm
954x 16.0 sq.mm
963.5 x 50.0 sq.mm
973.5x 70.0 sq.mm
983.5x 95.0 sq.mm
993.5x 120.0 sq.mm
1003.5x 185.0 sq.mm
101Providing & Fixing in position frame made out of M.S. angle (riveted or welded) as per IS: 2062-2011 finished with two coats of red oxide and two coats of enamelpaint including cutting, welding, holes etc. of following sizes as required. All drawing as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR40mm x 40mm x 5mm
102Supply, Installation, Testing and Commissioning of Wall mounted ISO 9001:2015 & 14001 or higher level certified company made Communication enclosure (Rack) of Minimum 500 MM Depth with made from CRCA & hot dip powder coated, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with \"U\"Marking , with Allround protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\" 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\" 1U, mountable socket strips with 6 nosof 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with fastner of suitable capcity etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .9 U wall mounted Enclosure
103Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipationwith UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in complianceto IEC standards. System Lumen efficacy of = 120 lm / watt, THD < 10 % ,p.f.=0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade markcertificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.LED Downlight 18/20W
104SITC ofI SOC ertifiedc ompanymade MNRE approved & confirming to IS:12933P-1,2,3&5 Evacuated tube Collectorstainless steel (SSgrade:304) storage tank with electrical back up with Portable Residual Current Device (PRCD) facilityform OEM, CRCA Powder coated /MS standf or Collector & Tank etc. as required. off ollowing capacity complete in all respect. Appropriate OE M test certificate shall be submittedby contractor .Al lasperpre approved by Engineer incharge For additional technical parameters of products / work , refer Annexure \"A\" attached with this BSR System capacity 250 Litre/day ,minimum number of tubes to be provided with the system are 34 Nos of Dia. 47 mm, Length 1500 mm or 23 Nos of Dia 58 mm and Length 1800 mm
105Providing&FixingofBISapprovedCurrentTransformerasperPWDspecificationforelectricalWorks,ISImarkedasperIS2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCTshallbebroughtoutsuitabletoaterminalblockwhichshallbeeasieraccessiblefortestingandterminalconnection,withallnecessarysupportinexistingpanelincludingconnectionetc.asrequiredCurrenttransformerResinCastWoundPrimary/RingTypeTapeWoundasperIS16227with,AccuracyCl,CTratioandburdenasspecified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm(minimum),includingallnecessarysupportinexistingpanelincludingconnectionetc.asrequired.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\"A\"attachedwith this BSR . C T Class 1, Ratio upto 150/5, Burden 5 VA
106C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
107Providing&LayingofsyntheticropeforsubmersiblepumpISImarked(IS:5175)offollowingsizes.completeinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersof products/ work , refer Annexure \"A\" attached with this BSR . 16mm
108Supply,Installation,Testing and Comissioning of ISOcertified company made self contained drinking water coolar with BEE Rated energy efficienthermetic sealed type comressor, non CFCrefrigerent suitable for operationon230V/1pH/50Hzacsupply,Fullstainlesssteel(S304)bodyandtank,stainlesssteelwatertray,minimumtwonosfaucetsandsuitabledrainagesystemcompleteinallrespectwith300mmheightMSfabricatedandpaintedplateform.completeinallrespectofthefollowingcapacity.NABLaccredeated/CPRI/ERDAlabtestingreportswithOEMcertificatemustsubmittedtoengineerincharge.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs
109Supplying and fixing of ISOCertified company made Krone module with base frame asper PWDspecification for electricalWorks,in the recess/surface made outof 16SWG sheet steel box, front openable ,having locking arrangements duly powder painted., with this BSR . 10 Pairs
11050 Pairs
111Supply,Installation and Testing of 4pair, 100Ohm impedance ,Cat6/6A patch cords should be constructed of minimum 23/24AWG ,stranded bare Copper cable with FRPVC/LSZHJacket, withanenhancedperformancebyfactorymouldedRJ45connectorsasperANSI/TIA/EIA568suitableforCat6/6AapplicationcomplyingtolatestammendmentsCategory6/6AStandards,According.toTIA568,minimumrequirementfor1GBASE-T/10GBASE-Tperformance.PatchcordsshallbestraightthrucablecompatiblewithbothT568-AandT568-Bwiringschemes,Minimum750to1000matingcyclesinplugcontactsforlongdurabilitycompleteinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparameters of products/ work , refer Annexure \"A\" attached with this BSR. Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord 1Mtr.
1122 Mtr.
113Supply,Installation,TestingandComissioningofSilentDGSet(AsperlatestCPCB emission norms) having specifications as per A, B, C, D, E, F,G,H A.1500RPMDieselEngineconformtoBS:649/5514ofsuitableBHPEngineshallhaveresidentialsilencer(isolatedfrommainDGchamber),upto3Mexhaust piping (with insulation & cladding ) as required .C.StandardcanopywithWeatherproof,powdercoatedAccousticenclosureforDGsetforsoundattenuationfabricatedfrom1.6mmCRCAsheetsteel(structure)withsidewallfabricatedfrom1.6mmCRCAsheet&filledwithglasswool(96Kg/m3)/Foam.asperIS8183thedoorsof28/40/50/85mmthickasperratingandfabricatedfrom1.6mmCRCAsheetpackedwithaccousticmaterial,Alldoors/openingaresealedwithneoprene/EPDNgaskets.Theenclosurehasbuiltinfueltank,withprotectionandtrippingofDG set against temperature of more than 50 degree centigrade D.Electronic/Mechanicalgovernor,Manual&electricStart,Batterieswithbattrycharger,Engineinstrumentspanel,AVMpadsAllcontrolsforoperationofDGsetarefromoutsidetheenclosurewithDGcontrolpanelhavingMicroprocessorbasedGensetmonitoring&controlsystem,MCCB/ACBofsuitablerating,Ammeter,Voltmeter,PFmeter,frequencymeter,KWHmeter,digitalfueldisplaymeter,Ind.lampsetc.mountedinsideenclosure,visibleandaccessiblefromoutside.TheenclosureshouldbesuitableforfollowingcapacityDGsetsandalternator.Noiselevelshallbelessthan75dBatadistanceof1Mtrs.dulycertifiedbyauthorisedagencyetc.completeinallrespect of following capacity : Radiator Cooled & Turbo Charged /AC 125 KVA at 0.8 pf 415V 50Hz 3-?
114Supply,Installation,TestingandComissioningofAutomainfailure(AMF)PanelfabricatedfromCRCAsheetsteel2mmThick,Powdercoatedfinish,EngineStart&Stopcommands,controlRelays,Ammeter&Voltmeterwithselectorswitches,Control&2nos4polePowerContactorswith2no.ofrequiredsize4poleMCCB,Timers,ElectronicHooter,Visual&Alarmindicationforfaults,UPS,operatorinterfacepanelcompleteinallrespectsuitableforfollowingcapacityDGsets.OEMMusthaveBIScertificateand&shall have submit NABL / CPRI / ERDA lab type test reports before execution asrequiredcompleteinallrespect.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproducts/work,referAnnexure \"A\" attached with this BSR . PLC Based: 100 to 140 KVA
115Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for baseflange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) as perIS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ).The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .Octagonal MS Polesmade of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.)8 Mtr.
116S I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026- 1977 & lossesas defined as per IS 1180 part I 2014. including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .NABL accredeated/ CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .250 KVA with Off -LTC (+5% to - 10% @ 2.5%)
117Supply , Installation, Testing and Comissioning of factory made11 KV, 630 A, 20kA / 3 sec, Out door Extensible type IP54 for panel & IP67 for main circuits Ring main unit (RMU) IEC 62271-200in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuitbreaker with over load, Earth fault, short circuit relay, copper bus bar, bus support and insulation marerial epoxy resin,ring core protection & metering CT, Auxiliary relay for WTI, OTI ,Bucholz alarm & trip along with annuciator panel, master trip relay, mechanical ON / OFF /Earth indication, Voltage presence indicator, Shunt trip coil, 24 V DC power pack, Digital multi function meter, with Bus PT panelwith 3 Nos single phase voltage transformers of the ratio 11kV/v3 / 110 V/v3, 25 VA, Class 1.0 with HT fuses in the primary and MCB on the secondary side, Voltmeter with selector switch, R Y B phase indication, Anti reflex operating handle, right angle boots etc. OEM Must have BIS certificate and&shall have submitNABL / CPRI / ERDAlab tpye test reportsbefore execution as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
118Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i)Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set (To be supplied by DISCOMs), (iii)TT Block, (iv) 6mm Bakelite sheet on all sides, (V) 3/6 core copper cable for interconnections etc. as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
119Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .Welded mesh 25 mmx 25 mm x 2.1 mm
120Providing & Laying XLPE insulated as per IS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .3 core 185.0 Sq.mm
121Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .11 KV End Termination Kit Indoor type 3 core 120/150/185 Sq.mm
12211 KV End Termination Kit Outdoor type 3 core 120/150/185 Sq.mm
123Providing & laying of Double wall corrugated pipe confirming to IS : 14930 P - 1 & 2with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required( Excavation of Earth to be paid Extra as required. )of following Outer Dia. / Inner dia as per IS:4984:1995. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .120 / 103.5 mm
124110 / 95 mm
125Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) as per PWD specification for electrical Works, ISI marked IS:13340-41 / conforming to IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.35 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 250 times of rated current,including making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . Heavy dutyThree phase 525 V, 50 Hzcylindrical capacitor (Bank)
126Providing & Fixing of IP54 on front microprocessor based three phase sensingpower factor correction relay , IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485,indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, VTHD, ITHD,metering facility as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reports.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 12 to 14 stage
127Providing & Fixing ofISO certified company madeCam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 32 AMP
128Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 3 pole Power contactorswith following AC 3 Rating Up to 12 Amp
12913 to 25 Amp
13032 Amp.
13140 Amp
132SITC ofDraw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker (ACB) as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 in existingLT panel suitable for LT installation 440 V, 50 Hz and havingadjustable over load short-circuit, earth fault and withseparate LED indication for each type of fault ,Password protected relase (trip mechanisum) shall confirm to EMI/ EMC test , LCD/LEDdisplay , Thermal memory , pollution degree 4, trip free mechanisum , suitable for ambient 50 degree and utilization catagary B.In built electrical & mechanical anti pumping fearute , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electricaloperation 10,000 upto 2000 A rating and 5,000 for2500 A. including making connectionsetc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . Microprocessor based release Draw out type (Manual spring charged) 4Pole 800 A Rating, 50kA

AI Tender Summary

OUR REF NO 30557210
AUTHORITY Trust & NGO
TENDER VALUE 57.20 Lakhs
LAST DATE 24-01-2022
Authority
Authority Name Nathdwara Temple Board
Work Description Electrical Work Of Multipurpose Veterinary Hospital And Polyclinic At Nathuwas Electrical Work Of Multipurpose Veterinary Hospital And Polyclinic At Nathuwas
Basic Detail
Tender No 8145/nv/2021-22 dt 31122021
Bidding Type Tender
Location
City nathdwara
State Rajasthan
Key Dates
Publish Date 03 Jan 2022
Submission Date 24 Jan 2022
Open Date 27 Jan 2022
Finance
Tender Value 57.20 Lakhs
Tender Fee 1190
EMD 1.14 Lakhs
Exemption Not Available
Document List
a616717c-d912-432c-b643-4614c82178a8.html
AgreementTermsandConditio.pdf
BOQ_451150.xls
CONDITIONS.pdf
ELECTRICALWORKANNEXUREA.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 03, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 24, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 27, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a616717c-d912-432c-b643-4614c82178a8.html

pdf

AgreementTermsandConditio.pdf

xls

BOQ_451150.xls

pdf

CONDITIONS.pdf

pdf

ELECTRICALWORKANNEXUREA.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders