Redevelopment Of Refugee Market At Kotwali Bazar Dharamshala, kotwali-Himachal Pradesh

smart city mission has published Redevelopment Of Refugee Market At Kotwali Bazar Dharamshala. Submission Date for this Tender is 21-01-2022. Civil Work Tenders in kotwali Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30532781
Redevelopment Of Refugee Market At Kotwali Bazar Dharamshala
Open Tender
Indian
Himachal Pradesh
kotwali
21-01-2022

Tender Details

Redevelopment Of Refugee Market At Kotwali Bazar Dharamshala

Key Value

Document Fees
INR 10000 /-
EMD
INR 754000.0 /-
Tender Value
INR 3.76 Crore /-

BOQ Items

Name of Work:Redevelopment of Refugee Market at Kotwali Bazar Dharamshala
Sl. No. Item Description
1Demolishing stone rubble /Brick masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwith allleads and lifts and as per direction of Engineer-in-charge : In Cement Mortar
2Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable materialwith allleads and lifts and as per direction of Engineer-in-charge
3Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.:-Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking with allleads and lifts and as per direction of Engineer-in-charge
5Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking with allleads and lifts and as per direction of Engineer-in-charge
6Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stackingwith allleads and lifts and as per direction of Engineer-in-charge
7Dismantling G.I roofing including ridges, hips, valleys and gutters etc., and stacking the material with allleads and lifts and as per direction of Engineer-in-charge
8Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, allleads
9Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earthwith allleads and lifts and as per direction of Engineer-in-charge
10Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,with allleads and lifts and as per direction of Engineer-in-charge .:-All kind of soil for RWH MH, Fire Tank & Pump Room
11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with allleads and lifts and as per direction of Engineer-in-charge
12Disposal of excavated surplus earth lead up to with allleads and lifts and as per direction of Engineer-in-charge
13Random rubble masonry/polygonal rubble masonry ofCement Mortar 1:4(1 cement:4 sand) (uncoursed/brought to courses) with hard stones of approved quality in foundation and plinth/Retaining wall etc. including levelling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level in
14Boulder filling dry hand packed tightly as in behind Retaining Structure & plinth filling Complete all as per drawing & technical specification and as directed by Engineer-in charge.
15Providing and laying cement concrete 1:3:6(1cement : 3 sand : 6 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth
16Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centring, shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceilingand removal of the same for insitu-reinforced concrete & plain concrete work in:with allleads and lifts and as per direction of Engineer-in-charge
17Foundation, footings basis of columns etc. and mass concrete.
18Columns, pillars, posts and struts:-Circular or curved /Square in plan.
19Beams, cantilever, girders and lintels.:-Sides and Soffits of beams, beam haunching"s, cantilever girders, bressummers and lintels not exceeding 1 Metre in depth:-in all heights from floor.
20Flat surfaces such as soffits of suspended floors, roofs, landings and the like:-Floors etc.upto 200mm. in thickness.
21Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters buttresses, plinth and string courses and the like.
22Stair cases with sloping or stepped soffits excluding landing.
23Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
24Edges of slabs and breaks in floors and walls:-Under 20 cm wide
25Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centring, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.:-All Works up to Plinth Level:-Foundation Footing, Base of Column etc. (Note :- Cement content considered in this item should no be less thank @ 330 kg/cum
26Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centring, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.:-All Works Above Plinth Level (Note :- Cement content considered in this item should no be less thank @ 330 kg/cum
27Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
28Providing Tor steel reinforcement of Grade Fe-550 for R.C.C. work including bending, binding and placing in position complete up to anylevel :
29Providing and laying autoclaved aerated cement blocks masonry with 150mm/200/230mm/300 mm thick AAC blocks in super structure above plinth level up to anyfloor level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).
30Providing and fixing 12 mm thick frameless toughened glass Wall/door shutter of approved brand and manufacture, including providing and fixing required door fittings, all complete as per direction of Engineer-in- charge (Door handle, lock and stopper etc.to be paid separately).
31Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-incharge.:-With stainless steel cover plate minimum 1.25 mm thickness
32Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600:-Upto 5 mm depth and 5 mm width
33Supplying and fixing rolling shutters of 80x1.25 mm M.S. laths with 1.25 mm thick top cover of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
34Providing and fixing ball bearing for rolling shutters complete all as per drawing and technical specification and as directed by Engineer-in-charge.
35Providing and Fixing factory made uPVC door frame, made of uPVC extruded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 no"s of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fasteners, all complete as per manufacturer"s specification and direction of Engineer-in-charge.
3635 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded solid PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitred cut & joint with the help of PVC solvent cement, self-driven self-tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self-driven self-tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer"s specification and direction of Engineer-in-charge.
37Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
38Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension.
39Providing and fixing glazing in UPVC door, window, ventilator shutters and partitions etc. including all accessories required for installation glass complete as per the architectural drawings and the directions of engineer-in-charge :--With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ Sqm)
40Providing fixing bright Stainless Steel tower bolts of size 250x10mm(barrel type) with screws etc. complete.
41Providing fixing 125 mm longStainless Steel D-handle for doors/windows with screws etc. complete.
42Providing fixing 600 mm longStainless Steel Pull Handle for glass doors including all accessories required complete all as per drawing and manufacturer specifications.
4315mm Cement plaster withCement Mortar 1:6 (1Cement:6 Sand) in single coat on the rough side of brick/ concrete/stone walls for interior/ exterior plastering up to any floor level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth.
446mm Cement plaster to ceiling:-In Cement mortar 1:3(1 Cement:3 Sand)complete all as drawing and technical specification and as directed by Engineer-in-charge.
45Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete.
46Applying priming with cement primer coat on new concrete / masonry / asbestos cement / plastered surfaces after and including preparing the surface by thoroughly cleaning oil,grease,dirt and other foreign matter and sand papering as required with :-Ready mixed Cement primer
47Wall painting (two coats) with acrylic emulsion paint of approved brand and manufacture for interior grade on undecorated concrete/stone/plastered wall surfaces to give an even shade including t thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth including applying of putty a required for metling the surface
48Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
49Granite of any colour and shade:-Area of slab up to 0.50 sqm
50Granite of any colour and shade:-Area of slab Over0.50 sqm
51Providing and laying vitrified floor tiles in 600x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.
52Providing and laying antiskid ceramic floor tiles of 8-10mm.thicklaid on a bed of12mm. thick cement mortar 1:3 (1cement:3 sand) finished with flush pointing in white cement. colour and size as per direction of Engineer-in-charge
53Providing and fixing digital HD Ceramic wall tiles of6 mm thick with 12 mm thick cementmortar 1:3(1 cement :3 sand)and jointedwith cement slurry. colour and size as per direction of Engineer-in-charge
54Steel work welded in built-up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of red lead paint:-In beams joists channels ,angles , tee ,flats with connection plates or angle cleats as in main and cross beems,hip and jack rafters, purlins connected to common rafters and the like.
55Painting two coats (excluding priming coat)on new steel and other metal surface under coat with ready mixed paint brushing to give an even shade including cleaning the foreign matter :-With ready mixed paint other than white
56Providing and fixing 0.60mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyester (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyester of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accessories" as required as per the direction of Engineer-in-charge.
57Providing and fixing ridges or hips 60 cm overall with 0.60mm thick prepainted steel sheets in roofing with hot dipped metallic zinc coated sheets with top coat of regular modified polyester organic coating of 20 microns over 5 microns primer coating + back coat of polyester of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts & nuts 6mm dia & prepainted G.I. limpet and bitumen washers complete with all accessories as required as per the direction of Engineer in Charges.
58Providing and fixing M.S. BP Sheet 1.66mm to 20mm thick in eaves board /facia /soffits/ ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in-charge (Base members of steel work shall be measured & paid separately)
59Providing and fixing polycarbonate transparent sheet 1.20mm thick in roofing with galvanised J or L hooks bolts and nuts with G.I. Limpe and bitumen rubber washer complete with all accessories as required as per direction of Engineer-in-Charge.
60Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
61Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
62Providing and laying 60 mm thick factory made chamfered edge Cement Concrete paver blocks of M-35 grade with approved colour design and pattern in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 25mm thick cement mortar 1:4 (1 cement : 4 sand), compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
63Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc.. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer"s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
64Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :
65Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to any level, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, any lead :-Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
66Providing and fixing high pressure PVC Spigot and Socket, waste and ventilating pipe ISI Marked including fixingwith approved adhesive complete.
67PVC Pipe 150 mm dia
68PVC Pipe 110 mm dia
69PVC Pipe 75 mm dia
70Providing and fixing PVC Plain bend ISI Marked including fixing with approved adhesive complete :-
71PVC Plain bend 110 mm dia
72PVC Plain bend 75 mm dia
73Providing and fixing PVC door bend with oval access door, insertion rubber washer 3 mm thick bolts and nuts ISI marked complete including fixing with approved adhesive complete :-
74PVC Door bend 110 mm dia
75PVC Door bend 75 mm dia
76Providing and fixing PVC floor trap ISI Marked of self cleaning design including fixing with approved adhesive, cost of cutting and making good the walls and floor etc. complete
77Providing and fixing PVC Single Equal Branch with oval access door, ISI Marked insertion rubber washer 3 mm thick bolts and nuts complete including fixing with approved adhesive etc. complete
78110 mm dia
7975 mm dia
80Providing and fixing PVC Collar ISI Marked including fixing with approved adhesive complete :-
81150 mm dia
82110 mm dia
8375 mm dia
84Providing and fixing PVC Clamps ISI Marked of approved design with steel screw and rawal plug etc. Complete :-
85110 mm dia
8675 mm dia
87Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
88Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :i/c carriage of material in all leads & lifts and as per the direction of Engineer in ChangeInside size 90x80 cm and 45 cm deep including SFRC cover with frame (Medium duty) 500mm diainternal dimensions, :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
89Providing and fixing white vitreous China extended wall mounting water closet of size 790x370x690 mm of approved shape including providing & fixing white vitreous China cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc. complete.
90Providing and fixing white vitreous China flat back small stall urinal of size 26.5 x 31.5 x 44 cm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of three half small urinals with 10 litre P.V.C. automatic flushing cistern
91Providing and fixing Health faucet ABS with rubbit cleaning system, flexible tube up to 1.25 mtr.long PVC Flexible tube & ABS wall hook to extended wall mounted type W.C. of quality and make as approved by Engineer - in - charge.
92Providing and fixing Oval Shape wash basin on R.C.C Slab, including 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, andmaking good the walls wherever require:-White Vitreous China oval shape Wash basin size 540x410 mm with15 mm C.P. brass pillar taps
93Providing and fixing P.V.C.Flexible pipe waste pipe for sink or wash basin including:-P.V.C. waste fittings complete.:- 32 mm dia
94Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge:-32 mm nominal outer dia Pipes
95Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge:-50 mm nominal outer dia Pipes
96Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall:-25 mm nominal outer dia Pipes
97Providing and fixing 20 mm Nominal Outer dia pipe Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge:- Concealed work, including cutting chases and making good the walls etc.
98Providing and fixing unplasticized PVC connection pipe with brass unions : 45 cm Long
99Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
100Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
101Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
102Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
103Providing and fixing C.P. Brass Towel rail complete with C.P. Brass brackets fixed to wooden plugs with C.P. Brass screws :600x20mm
104Providing and fixing 600mm x 120 mm glass shelf with C.P. Brass bracket and guard rail complete, fixed to wooden plugs with C.P. Brass screws.
105Providing and fixing chromium plated brass soap dish with C.P. Brass brackets fixed to wooden cleats with C.P. Brass screws :-
106Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
10732 mm nominal bore
10825 mm nominal bore
109Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
110Providing and fixing URINAL PARTITION of size 1195x550mmwith 12mm thick laminated panel including all Stainless steel accessories required for fitting this paneland complete all as per drawing and technical specification and as directed by Engineer-in-charge.
111Wiring for light point / fanpoint /exhaust fan /call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group-C
112Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. S.P. 5/ 6 Amps one way Modular switch.
113Supplying and fixing following rating Modular switch / socket in the existing switch box / cover plate including connections etc. as required 5 pin, 5/ 6 Amps Modular socket outlet.
114Supplying and fixing G.I. Modular box of (140mm x78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
115Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
116Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
117Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
118Supplying and fixing ceiling rose on the existingjunction box / wooden blockincluding connections etc. as required.
119Providing and fixing concealed LED Down Light with 24 Watt, complete with all accessories, connections, testing and commissioning etc. as required. As per direction of Engineer in Charge.
120Providing and fixing Hanging Pendent LED Light 220 -240 volt, 60 wattage maximum rating, including with all necessary fitting of Lighting , Complete all metrials as per direction of Engineer - in -charge .
121Providing and fixing concealed LED Down Light with 15 Watt, complete with all accessories, connections, testing and commissioning etc. as required.As per direction of Engineer in Charge.
122Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan boxand earthing etc. as required:- Ceiling Fan 1200 mm sweep, Category-A
123Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-Exhaust Fan, Heavy duty, 300 mm sweep
124Supplying and Erectionof4M Decorative Pole with Single Arm made up of MS Section of Dia 112mm and 60mm with Base Plate of 250 x 250 x 10mm. Pre-treatment through shot blasting and polishing method. Top coat of UV rays resistant exterior grade PU Paint. 40-45W LED Hanging type Post Topshall be IP66 protected made up of Aluminium with polycarbonate diffuser. Pole should be PU painted (Polyurethane Paint)with suitable colour including carriage ofmaterials with all lead and lifts. Materialsas approved by " DSCL" & As per direction ofEngineer-in - Charge
125Providing foundation for Proposed Street Lightwith RCC M20 including excavation in all types of soil, back filling , dewatering etc. complete as per drawing & specifications.
126Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
127Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days with carriage of materials for all leads and lifts as per "DSCL".
128Supplying, fitting and placing HYSD bar (Fe 500) reinforcement in sub-structure complete as per drawing and Technical Specifications including carriage of materials for all leads and lifts as per "DSCL".
129Reinforced Cement Concrete (RCC Grade M20) in Open Foundation complete as per Drawing and Technical Specifications including carriage of materials for all leads and lifts as per "DSCL".
130Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 200 mm width X 50 mm depth X 1.6 mm thickness
131Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- 50 mm. dia
132Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- 32 mm. dia
133Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.120 mm dia (OD-17 mm & ID-103 mm nominal)
134Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts gradeon surface etc. of the required size:- Armoured cable 50 sq. mm (3.5 core)
135Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts gradeon surface etc. of the required size:- Armoured cable 25 sq. mm (3.5 core)
136Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts gradeon surface etc. of the required size:- Armoured cable 10 sq. mm (4 core)
137Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.PVC insulated HRFR LS Copper conductor 10.0 Sq. mm. 3 Core x 10.0 Sq. mm.
138Supplying and erection offollowing depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall havecable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:- 450 mm deep (nominal)
139Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacitywith 4 No. copper strip bus-bars each of length 450mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (530mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
140Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 Amps. Cat-A.
141Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. :- 100 Amps. Cat-A.
142Supplyingand fixingoffollowing way triplepoleandneutral, sheetsteel MCB distribution board, 415 volts, on surface / recess, with provision for 4-pole MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-4 way (8+12),horizontal type
143Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
144Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. :- 63 Amps. Cat-A.
145Supplyinganderection of 6amps. to 32 amps. rating, 10 KA breaking capacity, 240volts, "C" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Single pole. Cat-A.
146Supplyingand fixingoffollowingway, singlepoleandneutral sheetsteel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Double door-8 way
147Supplying, Installation, Testing & Commissioningof GIearthing / grounding protection system for Electrical system in Building including all these following materials ; { 1. GI earthing rod 40 X 2 Mtr, 2. chemical bag (15kg) in 2 nos, 3.Advance Maintenance free gel chemical (5 Ltr.), 4.GI wire 8 Sq mm, 5. Inspection Cover (300 X 300), 6.Installation & Commissioning charges , 7.Shipping Charges},Labour Charges & Materialsas approved by " DSCL" & As per direction of"Engineer in Charge"..
148Providing and fixing of 25mm x 5 mm G I strip on surface or in recess for earthing connections etc. as required.
149Supplying and erection of three piece non linear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. Materialsas approved by " DSCL" & As per direction of"Engineer in Charge".
150Supplying, Installation, Testing & CommissioningofSurge Protection Device4 Pole for the Surge Protection of Electrical System including with the all special fittings as required.
151SUB HEAD-C FIRE FIGHTING WORKS
152Supply, Installation,testingandcommissioningof Electric driven Main Fire Pump suitablefor automatic operationandconsistingoffollowing,completeinall respects, as required :Horizontal type, multistage, centrifugal, Horinzontal End Suction Long Coupled pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronousspeed3000 RPM,suitableforoperation on415volts,3phase50Hz,ACsupplywithIP55 protectionforenclosure,horizontalfootmountedtype with Class-"F" insulation, conforming to IS-325.Epoxy coated common base plate for mounting pump and motorfabricated of mild steel channel as per manufacturer"s recommendation with required no. of heavy duty Anti Vibration pads, coupling, coupling guard, foundation bolts etc. as required. Fire Pumps should be BMS compatible & EF class.Pump shall be capable of handling not less than 150% of rated capacity at a head not less than 65 % of rated head. The shut off head shall not exceed 120% of rated head. HP of motor should be 20% more than the calculated HP.Flexible Coupling and coupling guard for direct coupling of pump and motor.2280 lpm at 70 m Head (For Hydrant System), Elect Load of Motor -25 KW(Approx) Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.
153Supply, Installation,testingandcommissioningof diesel engine driven main fire pump suitable for automatic operation and consistingof following, completeinallrespects,asrequired:(DieselDriven Pump) Horinzontal End Suction Long Coupled, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. SuitableHP,2900RPMwatercooledwithradiator, diesel engine conforming to relevant IS standard completewithautostartingmechanism,12/24volts electricstartingequipment,dieseltank,exhaustpipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitablecementconcretefoundationdulyplastered and with anti vibration pads.Fire Pumps should be BMS compatible & EF class. 2280 lpm at 70 m Head24 volts 180 AH lead acid battery (12 volts - 2 Nos)Detail of Engine as described above, Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.
154Supply, Installation,testingandcommissioningof electricdrivenpressurisationpumpsuitablefor automaticoperationandconsistingoffollowing, complete in all respects, as required : (Jockey Pump) Horinzontal End Suction Long Coupled,multistage,centrifugalpumpofcast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.SuitableHPsquirellcageinductionmotorTEFCtype suitableforoperationon415volts,3phase50Hz AC supply with IP 55 class of protection for enclosure, horizontalfootmountedtypewithClass-"F"insulation, conforming to IS : 325.M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Fire Pumps should be BMS compatible & EF class.180 lpm at 70 m Head for Hydrant System ,Elect Load of Motor - 5KW (Approx)
155Supply, Installation, Testing and Commissioning of Electric driven Terrace pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal Type, single stage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and flow of 450 lpm at 40m of 10 KW, head conforming to IS standards. b) Squirrel cage induction motor with suitable HP with synchronous speed 3000 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. c) Common Base plat for Pump and motor and coupling, coupling guard, vibration pad, cables and other accessories as required for complete installation of pump set.
156Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet,compartmentalizedwithhingedlockabledoors, dustandverminproof,powdercoatedofapproved shade after 7 tank treatment process, cable alley, inter-connectionwithsuitablesizecopperconductor cable/solidcopper strip, havingswitchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitableformainfirepump,pressurizationpump& dieselpumpsetcompleteasperCPWDspecification withfollowingincomingandOutgoings,suitablefor operationon415V,3phase,50HzAcSupplywith enclosure protection class IP 42 as required : Electrical panel should be use for BMS compatible pump & EF class. Incomings: Suitable Incoming current of 400A,4 Pole MCCB, Ics=100% Icu Rating, Digital Voltmeter 0-500V with selector switch, Ammeter (0-500 A) with selector switch & CTs etc., LEDtypeRYBphaseindicatinglamps,ON,OFF,trip indicating lamps, Set of CopperBus Bar 800Amps Outgoings: (Note:Alloutgoingfeedersforpumpsshouldhave digital Ammeter with selector switches,and LED type ON, OFF, trip indicating lamps), Main Fire Pump:- 1Nos fully automaticStar/Deltastartersuitableforpump withoverloadprotection,currentsensingtypesingle phasepreventorcompletewithallaccessoriesand internalwiringrequiredforautomaticoperation, selector switch for local/remote, auto/manual/OFF operation, ON/OFF indications with 2A SP MCB back up - 1 set,2Nos of 250 Amp TP+NL MCCB of 36 KA breaking capacity with heavy duty solid detachable neutral link (for 2 Nos. Soft Starter Feeder for 112 KW) with ON/Off indication with 2A SP MCB back up. Also provide manual bypass arrangement comprising, DOL starter with 200A contactor with 2NO & 2NC auxiliary contacts. Over load relay of rating 135-225 A within built single phasing preventer and Ammeter of range 0 - 225 A & 2Nos of associated CT"s of rating 250/5A of accuracy CL - I, 5VA burden. Also provide soft starter for each feeder as required. (Fire hydrant & Sprinkler pump), Jockey Pump:- 63 Amp, 36kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic DOL starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.- 1 set, DIESEL ENGINE CONTROL:- Control for diesel engine comprising -Automatic/Manualsectorswitch&3attemptsstarting device,timersandrelaysasrequired,pushbuttons, start/stop in manual mode, Indicating lamp for high/ Low Lub.Oilpressure,High Water Temp and Engine on indication, Battey with Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter,All standard relays and accessories for automatic operation of diesel engine, System Controller, Designing, Supply, Installation Testingand commissioning of system controllertocontrol operation ofmainelectricfirepump,dieselpump,Pressurization pump,Terracepumpinsequenceasperspecification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification, TERRACE PUMP:- Supplying, Installation, Testing and Commissioning of Control Panel suitable for automatic operation of firefighting pump consisting (Terrace pump):- (a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price.(b) Facility for more selections i.e auto or manual.(c) Protection failure and control cabling.(d) interlocking of pressure switch with pumps, Major component of panel are as under :63A FP MCB with soft starter, single phasing preventor,With push button,On,off, trip indication lamp,space heater with thermostate, cooling exhaust fan
157Supplyingandfixingoffirebrigadeconnectionof cast iron body with gun metal male instantaneous inlet couplingscomplete 150 mm butterfly valve, Flanges etc withcapandchainasreqd.for suitabledia MS pipe connectionconforming to IS 904 as required :4 way-150 mm dia M.S. Pipe
158Providing and fixing fire brigade suction hose coupling (draw out connection) with nut for female coupling as per IS-902 complete with 100mm dia. Suction pipe and foot valve (to be connected to static tank) complete as required andas per enclosed specification.
159Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
160Supplyingandfixingsingleheadedinternalhydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheelISI marked conformingtoIS5290(Type-A)withblank Gunmetal/Stainless Steel cap and chain as required :- Single headed Stainless steel/GM
161Supplying & fixing 63 mm dia short branch pipe with 20 mm nominal internal diameter sizenozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :-Stainless Steel (Grade 304)/GM
162Supplying and fixing 63 mm dia, 15 m long RRL hose pipewith63mmdiamaleandfemalecouplingsduly boundwithGIwire,rivetsetc.conformingtoIS636 (type-A) as required :-Stainless Steel (Grade 304)/GM
163Supplying andfixing first-aidHoseReelcompact type withMS constructionspraypaintedinpostofficered, conformingtoIS884completewiththefollowingas required. 20mmnominalinternaldiawaterhosethermoplastic (Textile reinforced) type -2 as per IS: 12585. 20mmnominalinternaldiagunmetalglobevalve& nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket & flanges.
164Providing and fixing stainless steel standard fireman"s axe with heavy insulated rubber handle tested to 20000 volts as per IS : 926 complete.
165Providing & fixing of MS fireHose cabinet outdoor type of size 0.90 Mx 0.60 Mx 0.50 M made of 6mm thick MS sheet with 6mm thick glazed glass doors i/c necessary locking arrangement suitable to accomodate 2nos 15m long hoses, one no branch pipe, etc. and mounted on 400 mm height agle . The cabinet shall be painted with redcolour shade No. 536 of IS: 5 externally & white internally complete in all respects for internal hydrant and as per enclosed specification.
166PIPES & VALVES Providing,laying,testing&commissioningof "C"class heavydutyMSpipeconformingtoIS3589/IS1239 includingWelding,fittingslikeelbows,tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. NOTE : Pipe upto dia 50 mm should be threaded/Socket weld forge fitting.
16725mm Dia
16832mm dia
16940mm dia
17050mm dia
17165mm dia
17280mm dia
173100mm dia
174150mm dia
175200mm dia (Wall Thicknes 6.3 mm)
176Laying,testing&commissioningof 4 mm thick tape over"C"class heavydutyMSpipe 150 mm Diaincluding pipes to be laid underground in 1 mtr below from ground and holiday test check as per IS:10221 complete as required as per approved.:-
177Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with gunmetal seat duly ISI markedcompletewithnuts,bolts,washers,gaskets conforming to IS 13095 of following sizes as required :
178200 mm dia (Gear Operated)
179150mm dia.
180100mm dia.
18180mm dia.
18265 mm dia.
183Providing,installation,testingandcommissioningof non-returnvalveoffollowingsizesconfirmingtoIS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
184200mm dia
185150 mm dia.
18665 mm dia.
187Providing, fixing, testing and commissioning forged brass ball valve full bore type with steel handle and teflon seat tested for 20 kg/cm2.
18825 mm nominal bore
18950 mm nominal bore
190Providing,installation,testingandcommissioningof stainlesssteelY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange.
191200 mm dia.
19280 mm dia.
193Providing & fixing of 25mm dia. gunmetal air release valve with all fittings and forged ball valve on header complete as required and as per enclosed specification rated for (0-15 Kg/Cm2) pressure rating.
194Providing and fixing 150mm Dia Pressure gauge (0-15 Kg/Cm2) complete with shut off valve duly calibrated before installation complete as required & as per enclosed specification.
195Providing, fixing, testing & commissioning of MS air cushion tank 6mm thick MS plate, 250 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MSplate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968.
196Providing, fixing, testing & commissioning of precharged double flanged vertical MS air vessel fabricated from 10 mm thick MS plate with dished ends fabricated from 10 mm thick MSplatecommon for pumps at drop of pressure including 50 / 80 mm dia inlet with isolating valve duly painted from inside and outside complete as required with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968.
197Pressure Vessel for Fire Pump room Recommended dia.: 450 mm Height of shell : 2000mm Working pressure: 10 Kg/Sq.cm Test Pressure: 15 Kg/Sq.cm
198For Terrace Pump Recommended dia.: 250 mm Height of shell : 1.2mm Working pressure: 10 Kg/Sq.cm Test Pressure: 15 Kg/Sq.cm
199Providing & fixing of Safety valve complete as per direction of Engineer incharge.:-25 mm dia
200Providing and fixing reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure, complete as perspecification.
201150mm dia.
20280mm dia.
20365 mm dia.
204Providing and fixing cable for Pump to MCC Panel including necessary support clamps at ceiling level and connection legs complete in all respects.
2053Cx4 sqmm PVC Armoured Cu Wire
2063Cx50 sqmm PVC XLPE armoured Cu Cable
2073Cx1.5 sqmm PVC Armoured Cu Wire
208Providing and fixing GI Earthing strip of Size 25 x 6mm for higher size motors and MCC panels to be connected in as approved manner to the general earthing system complete.
209Supply of Perforated GI Cable Tray (1.6 mm thickness)for Pump Room
210300 mm (50 mm depth)
211150 mm(50 mm depth)
212Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket as required as per specifications.
213Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications.
214Supplying & installation of MS structure for above ground pipingsupport or any other .
215Providing, fixing AUTO GLOW photo luminescent Signage"s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: In case of Fire, do not use lift, use staircase: 8" x 8"
216Providing, fixing AUTO GLOW photo luminescent Signage"s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Fire Equipment: 4" x 12"
217Providing, fixing AUTO GLOW photo luminescent Signage"s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: Fire Exit: 4" x 12"
218Supplying, installation , testing & Commissioning of Mini Motor Siren Supply Voltage:220V Ideal Audible Range: 200-400 Mtrs( for Main Building to make alert the building users in fire & emergency time e.t.c), as per direction of Engineerin charge.
219Wiring for light point / fanpoint /exhaust fan /call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group-C
220Supplying, Installation, Testing& Commissioningof CCTV Camera Dome or Bullet type for Indoor Surveillance with 2 year Licence including all accessories, as per Technical specification.
221Supplying, Installation, Testing& CommissioningSupply instalation,Testing and Commissioing of Server based NVR with HDD Storage 30 days as requiredas per Technical specification.
222Supplying, Installation, Testing& Commissioningof L2 Type 16 Port 250 range Poe switch with 2 sfp port including 6 port liu lodaed with patch code and 1 Gig SFP with all acessoriesas per as per Technical specification.
223Supplying, Installation, Testing& Commissioningof L3 switch with 26 sfp and 8 combi port including 24 port LIU loaded with patch code and 9 nos 1 Gig SFP with all acessories as per Technical specification.
224Supplying, Installation, Testing& Commissioningof 6U wall mount rack including all special fittings and complete in all respectsas per Technical specification.
225Supplying, Installation, Testing& Commissioningof Miscellaneous Accessories, Rack up-to 42 U or APSR, RJ 45 connectors, interfaces, Patch Cords, HDMI/VGA cable (min 4-5 meters) with connectors at both side, Jacks, Plugs, tags, identifiers, fixtures, clamps, screws, nut - bolts etc.all special fittings and complete in all respectsas per Technical specification.
226Supplying, Installation, Testing& Commissioningof of Monitor 42" with all aceeesoriesas per Technical specification.
227Supplying, Installation, Testing& Commissioningof Networking Cat6 Cable including all necessaryspecial fittings and complete in all respectsas required as per Technical specification.
228Supply installation ,testing and commissioning of Supplying and drawing following sizes of FRLS PVC insulated copper conductor, 3 x 1.5 sq. mmas per Technical specification.
229Supplying, Installation, Testing& Commissioningof Desktop/PC- Intel Core i5 (sixth generation or newer) or equivalentas requiredas per Technical specification.
230Supplying, Installation, Testing& Commissioningof UPS - 2 KVA ratingincluding all necessaryspecial fittings and complete in all respects as per Technical specification.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail