Public Administrative Department Government Departments Closing in 0 days TDR #30520823

Bids Are Invited For Glow Wire Test Apparatus To 960 Oc - Repairing, Servicing & Calibration , Endurance Test Machine For Switch With Inductive Load 40 Amp - Repairing, Servicing & Calibration , Heating Oven ( Hot Set Test Oven ) Amb.

Issued by Government Departments · Mumbai, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Jan 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are Invited For Glow Wire Test Apparatus To 960 Oc - Repairing, Servicing & Calibration , Endurance Test Machine For Switch With Inductive Load 40 Amp - Repairing, Servicing & Calibration , Heating Oven ( Hot Set Test Oven ) Amb. To 250Oc - Repairing, Servicing & Calibration , Dust Chamber For Ingress Protection Of Dust Test For Ip 5X / 6Xsize 2M X 1 M X 1 M - Repairing & Servicing , Apparatus For Ingress Protection Of Water Ip X3 / X4 - Repairing & Servicing , Impact Test Apparatus ( Ik Test ) Upto Ik 10 - Repairing & Servicing , Vibration Exciter Console 0.25 Hp Motor, - Repairing & Servicing , Auto Variable Transformer Output 1V – 300 V Ac - Repairing & Servicing , High Current Low Voltage Source 800 A / 6 V Lalith Test Equipment Make - Repairing & Servicing , High Current Low Voltage Source1200 A / 6 Lalith Test Equipment Make - Repairing & Servicing , Digital Vernier Caliper 0-300 Mm Mitutoyo - Repairing& Calibration , Digital Micro Ohm Meter1.9999 Milii Ohm To 1.9999 K.Ohm + / - 0.05 % - Calibration & Intermediate Check After 6 Months , Analog Million Mega Ohmmeter10 M.Ohm To 20X 106 Mohm / 500 & 1000V Dc - Calibration & Intermediate Check After 6 Months , True Rms Leakagecurrent Meter300 V / 2 Ma. - Calibration & Intermediate Check After 6 Months , Earth Resistance Test Apparatus12 V / 30 A - Calibration & Intermediate Check After 6 Months , Endurance Test Set Forswitches - Calibration & Intermediate Check After 6 Months , Digital Panel Meters Of Inductive Load For Plug & Socket 300 Vac / 30.0 Aac / 0.5 Pf Lag To Unity - Calibration & Intermediate Check After 6 Months , Digital Insulation Tester 199.9 Meg Ohm / 500V Dc - Calibration & Intermediate Check After 6 Months , Comparative Tracking Index Test Set. 750A Ac / 1.00 A Ac - Calibration & Intermediate Check After 6 Months , High Voltage Tester15 Kvac - Calibration & Intermediate Check After 6 Months , High Voltage Tester 5 Kv Ac - Calibration & Intermediate Check After 6 Months , High Voltage Tester 1.5 Kv Dc - Calibration & Intermediate Check After 6 Months , 3 Cell Ageing Oven Digital Temp. Controller Amb. To 150 Deg. C. L.C. : 0.1 Deg.C. - Calibration & Intermediate Check After 6 Months , Ageing Oven Amb. To 250 Deg. C Lc : + / - 1 Deg. C - Calibration & Intermediate Check After 6 Months , Thermal Stability Oven With Hg. In Glass Thermometer Oven :250Deg.Cglass Thermometer : 195 - 205 Deg.C. 0.1 Deg.C - Calibration & Intermediate Check After 6 Months , Profile Projectorx-Axis : 0-100 Mm Y-Axis : 0-100 Mm Magnification :20X Lc :0.005 Mm - Calibration & Intermediate Check After 6 Months , Computerized Tensile Testing Machine System500 / 5000 N - Calibration & Intermediate Check After 6 Months , Environmental Testchamber ( Cold Chamber ) - 70To 200 Deg. C. + / - 1 Deg.C. - Calibration & Intermediate Check After 6 Months , Universal Power Analyser Pm-3000A 0- 1000 V Ac, 10 - 10 Khz, 0-20 A Ac, Power Factor, 0-3.2 Kw - Calibration & Intermediate Check After 6 Months , Water Bath Upto 100 Deg.C L.C. : 0.1 Deg C - Calibration & Intermediate Check After 6 Months , Accessibility Test Control Panel ( Protection Against Electric Shock Test Apparatus ) 40 - 50 V Ac - Calibration , Digital Multimeter0-750 / 1000V Ac / Dc, 0- 10 A Ac / Dc, 0-50 M.Ohms - Calibration , Digital Thermometer250 Deg. C With Pt -100 Sensor And 1000 Deg. C With K Type Sensor - Calibration , Digital Temp. & Humidity Meter 0 To 60Deg.C / 10 To 100% Rh - Calibration , Digitalstop Watch 0- 9999 Sec Lc : 0.001S To 1S - Calibration , Electronic Weighing Balance 0 To 210 Gm L.C. :0.0001 G. - Calibration , Power Analyser Wt 310 E ( Use For Integrating Sphere ) 0- 600 V / 20 Ma - 15 A / 1 W -4 Kw - Calibration , Power Supply Ac / Dc 61603 ( Use For Integrating Sphere ) 150 / 300 Vac Auto, 15 Hz To 1 Khz - Calibration , 6 Channel Temperature Indicator0-400 Deg.C Lc : 1 Deg.C - Calibration , Test Panel For Lamp Cap Temperature Rise 0 - 300 V Ac Source L.C. : 1 V K-Type Temperature Indicator L.C. : 1 Deg. C - Calibration , Temperature Rise Test Apparatus 50 Aac, 19.99V, 199.9 Deg .C. - Calibration , Portable Power Analyser0-1000V Ac, 0-900 A Ac, 0-900 A Dc, 100 Ohm -90 Kohm - Calibration , Lux Meter0 .1 - 999990 Lux ( Calibration Up To 10000 Lux ) - Calibration , Electronic Weighing Balance15 Kg L.C. : 1 Gm - Calibration , Rotameter Water0 -120 Lpm L.C. : 2 Lpm - Calibration , Digital Rpm Meter2.5 To 30000 Rpm L.C. :0.1 / 1 Rpm - Calibration Total Quantity : 1

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 19-Jan-2022 27-Jan-2022

BOQ

Sl. No. Item TitleItem Description
1Glow Wire Test Apparatus to 960 oCRepairing, Servicing & Calibration
2Endurance Test Machine for Switch with Inductive Load 40 AmpRepairing, Servicing & Calibration
3Heating Oven (Hot set test oven)Amb. To 250oCRepairing, Servicing & Calibration
4Dust Chamber for Ingress protection of Dust testFor IP 5X / 6XSize 2m x 1 m x 1 mRepairing & Servicing
5Apparatus for Ingress protection of water IP X3 / X4Repairing & Servicing
6Impact Test Apparatus (IK test) Upto IK 10Repairing & Servicing
7Vibration Exciter Console 0.25 HP motor,Repairing & Servicing
8Auto Variable Transformer Output 1V – 300 V ACRepairing & Servicing
9High Current Low Voltage Source 800 A / 6 V Lalith Test Equipment makeRepairing & Servicing
10High Current Low Voltage Source1200 A / 6 Lalith Test Equipment makeRepairing & Servicing
11Digital Vernier Caliper0-300 mmMitutoyoRepairing& Calibration
12Digital Micro Ohm Meter1.9999 milii Ohm to 1.9999 k.Ohm+/- 0.05 %Calibration & Intermediate check after 6 months
13Analog Million Mega OhmMeter10 M.Ohm to 20x 106 Mohm/ 500 & 1000V DCCalibration & Intermediate check after 6 months
14True RMS LeakageCurrent Meter300 V/ 2 mA.Calibration & Intermediate check after 6 months
15Earth Resistance Test Apparatus12 V/30 ACalibration & Intermediate check after 6 months
16Endurance Test Set ForSwitchesCalibration & Intermediate check after 6 months
17Digital Panel Meters of inductive load for Plug & Socket 300 Vac/ 30.0 AAC/ 0.5 pf lag to UnityCalibration & Intermediate check after 6 months
18Digital Insulation Tester 199.9 Meg ohm/ 500V DCCalibration & Intermediate check after 6 months
19Comparative Tracking Index Test Set. 750A AC/ 1.00 A ACCalibration & Intermediate check after 6 months
20High Voltage Tester15 KVACCalibration & Intermediate check after 6 months
21High Voltage Tester 5 KV ACCalibration & Intermediate check after 6 months
22High Voltage Tester 1.5 KV DCCalibration & Intermediate check after 6 months
233 Cell Ageing Oven Digital Temp. Controller Amb. To 150 deg. C.L.C. : 0.1 deg.C.Calibration & Intermediate check after 6 months
24Ageing Oven Amb. To 250 deg. CLC : +/- 1 deg. CCalibration & Intermediate check after 6 months
25Thermal Stability Oven with Hg. In Glass Thermometer Oven :250deg.CGlass Thermometer : 195 - 205 deg.C.0.1 deg.CCalibration & Intermediate check after 6 months
26Profile ProjectorX-axis : 0-100 mm Y-axis : 0-100 mm Magnification :20XLC :0.005 mmCalibration & Intermediate check after 6 months
27Computerized Tensile Testing Machine System500/ 5000 NCalibration & Intermediate check after 6 months
28Environmental TestChamber (Cold Chamber) - 70to 200 deg. C. +/- 1 deg.C.Calibration & Intermediate check after 6 months
29Universal Power Analyser PM-3000A 0- 1000 V AC, 10 - 10 KHz, 0-20 A AC, Power factor, 0-3.2 KWCalibration & Intermediate check after 6 months
30Water Bath upto 100 deg.C L.C. : 0.1 deg CCalibration & Intermediate check after 6 months
31Accessibility test control panel (Protection against electric shock test apparatus) 40 - 50 V ACCalibration
32Digital Multimeter0-750/1000V AC/DC, 0- 10 A AC/DC, 0-50 M.OhmsCalibration
33Digital Thermometer250 deg. C with PT -100 sensor and 1000 deg. C with K type sensorCalibration
34Digital Temp. & Humidity Meter 0 TO 60deg.C/10 to 100% RHCalibration
35DigitalStop Watch 0- 9999 secLC : 0.001s to 1sCalibration
36Electronic Weighing Balance 0 to 210 gmL.C. :0.0001 g.Calibration
37Power Analyser WT 310 E ( Use for Integrating sphere)0- 600 V/ 20 mA - 15 A/1 W -4 KWCalibration
38Power supply AC/DC 61603(Use for Integrating sphere)150/300 VAC Auto, 15 Hz to 1 KHzCalibration
396 Channel Temperature Indicator0-400 deg.CLC : 1 deg.CCalibration
40Test panel for Lamp Cap Temperature Rise 0 - 300 V AC Source L.C. : 1 V K-Type Temperature Indicator L.C. : 1 deg. CCalibration
41Temperature Rise Test Apparatus 50 AAC, 19.99V, 199.9 deg .C.Calibration
42Portable Power Analyser0-1000V AC, 0-900 A AC, 0-900 A DC, 100 ohm -90 KohmCalibration
43Lux Meter0 .1 - 999990 Lux (Calibration up to 10000 lux)Calibration
44Electronic Weighing Balance15 Kg L.C. : 1 gmCalibration
45Rotameter Water0 -120 lpm L.C. : 2 lpmCalibration
46Digital RPM meter2.5 to 30000 RPM L.C. :0.1/1 RPMCalibration

AI Tender Summary

OUR REF NO 30520823
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-01-2022
Authority
Authority Name Ministry Of Micro Small And Meduim Enterprises
Work Description Bids Are Invited For Glow Wire Test Apparatus To 960 Oc - Repairing, Servicing & Calibration , Endurance Test Machine For Switch With Inductive Load 40 Amp - Repairing, Servicing & Calibration , Heating Oven ( Hot Set Test Oven ) Amb. To 250Oc - Repairing, Servicing & Calibration , Dust Chamber For Ingress Protection Of Dust Test For Ip 5X / 6Xsize 2M X 1 M X 1 M - Repairing & Servicing , Apparatus For Ingress Protection Of Water Ip X3 / X4 - Repairing & Servicing , Impact Test Apparatus ( Ik Test ) Upto Ik 10 - Repairing & Servicing , Vibration Exciter Console 0.25 Hp Motor, - Repairing & Servicing , Auto Variable Transformer Output 1V – 300 V Ac - Repairing & Servicing , High Current Low Voltage Source 800 A / 6 V Lalith Test Equipment Make - Repairing & Servicing , High Current Low Voltage Source1200 A / 6 Lalith Test Equipment Make - Repairing & Servicing , Digital Vernier Caliper 0-300 Mm Mitutoyo - Repairing& Calibration , Digital Micro Ohm Meter1.9999 Milii Ohm To 1.9999 K.Ohm + / - 0.05 % - Calibration & Intermediate Check After 6 Months , Analog Million Mega Ohmmeter10 M.Ohm To 20X 106 Mohm / 500 & 1000V Dc - Calibration & Intermediate Check After 6 Months , True Rms Leakagecurrent Meter300 V / 2 Ma. - Calibration & Intermediate Check After 6 Months , Earth Resistance Test Apparatus12 V / 30 A - Calibration & Intermediate Check After 6 Months , Endurance Test Set Forswitches - Calibration & Intermediate Check After 6 Months , Digital Panel Meters Of Inductive Load For Plug & Socket 300 Vac / 30.0 Aac / 0.5 Pf Lag To Unity - Calibration & Intermediate Check After 6 Months , Digital Insulation Tester 199.9 Meg Ohm / 500V Dc - Calibration & Intermediate Check After 6 Months , Comparative Tracking Index Test Set. 750A Ac / 1.00 A Ac - Calibration & Intermediate Check After 6 Months , High Voltage Tester15 Kvac - Calibration & Intermediate Check After 6 Months , High Voltage Tester 5 Kv Ac - Calibration & Intermediate Check After 6 Months , High Voltage Tester 1.5 Kv Dc - Calibration & Intermediate Check After 6 Months , 3 Cell Ageing Oven Digital Temp. Controller Amb. To 150 Deg. C. L.C. : 0.1 Deg.C. - Calibration & Intermediate Check After 6 Months , Ageing Oven Amb. To 250 Deg. C Lc : + / - 1 Deg. C - Calibration & Intermediate Check After 6 Months , Thermal Stability Oven With Hg. In Glass Thermometer Oven :250Deg.Cglass Thermometer : 195 - 205 Deg.C. 0.1 Deg.C - Calibration & Intermediate Check After 6 Months , Profile Projectorx-Axis : 0-100 Mm Y-Axis : 0-100 Mm Magnification :20X Lc :0.005 Mm - Calibration & Intermediate Check After 6 Months , Computerized Tensile Testing Machine System500 / 5000 N - Calibration & Intermediate Check After 6 Months , Environmental Testchamber ( Cold Chamber ) - 70To 200 Deg. C. + / - 1 Deg.C. - Calibration & Intermediate Check After 6 Months , Universal Power Analyser Pm-3000A 0- 1000 V Ac, 10 - 10 Khz, 0-20 A Ac, Power Factor, 0-3.2 Kw - Calibration & Intermediate Check After 6 Months , Water Bath Upto 100 Deg.C L.C. : 0.1 Deg C - Calibration & Intermediate Check After 6 Months , Accessibility Test Control Panel ( Protection Against Electric Shock Test Apparatus ) 40 - 50 V Ac - Calibration , Digital Multimeter0-750 / 1000V Ac / Dc, 0- 10 A Ac / Dc, 0-50 M.Ohms - Calibration , Digital Thermometer250 Deg. C With Pt -100 Sensor And 1000 Deg. C With K Type Sensor - Calibration , Digital Temp. & Humidity Meter 0 To 60Deg.C / 10 To 100% Rh - Calibration , Digitalstop Watch 0- 9999 Sec Lc : 0.001S To 1S - Calibration , Electronic Weighing Balance 0 To 210 Gm L.C. :0.0001 G. - Calibration , Power Analyser Wt 310 E ( Use For Integrating Sphere ) 0- 600 V / 20 Ma - 15 A / 1 W -4 Kw - Calibration , Power Supply Ac / Dc 61603 ( Use For Integrating Sphere ) 150 / 300 Vac Auto, 15 Hz To 1 Khz - Calibration , 6 Channel Temperature Indicator0-400 Deg.C Lc : 1 Deg.C - Calibration , Test Panel For Lamp Cap Temperature Rise 0 - 300 V Ac Source L.C. : 1 V K-Type Temperature Indicator L.C. : 1 Deg. C - Calibration , Temperature Rise Test Apparatus 50 Aac, 19.99V, 199.9 Deg .C. - Calibration , Portable Power Analyser0-1000V Ac, 0-900 A Ac, 0-900 A Dc, 100 Ohm -90 Kohm - Calibration , Lux Meter0 .1 - 999990 Lux ( Calibration Up To 10000 Lux ) - Calibration , Electronic Weighing Balance15 Kg L.C. : 1 Gm - Calibration , Rotameter Water0 -120 Lpm L.C. : 2 Lpm - Calibration , Digital Rpm Meter2.5 To 30000 Rpm L.C. :0.1 / 1 Rpm - Calibration Total Quantity : 1
Basic Detail
Tender No GEM/2021/B/1806649
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 19 Jan 2022
Submission Date 27 Jan 2022
Open Date 27 Jan 2022
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
2991975_Boq_2.xlsx
71c47ca4-ac3d-4bd3-bdcf-32643ac3202e.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 19, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 27, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 27, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 27, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xlsx

2991975_Boq_2.xlsx

pdf

71c47ca4-ac3d-4bd3-bdcf-32643ac3202e.pdf

TenderDetail
Loading tenders