Bids Are Invited For Glow Wire Test Apparatus To 960 Oc - Repairing, Servicing & Calibration , Endurance Test Machine For Switch With Inductive Load 40 Amp - Repairing, Servicing & Calibration , Heating Oven ( Hot Set Test Oven ) Amb.
Tender Overview
Project Description
Bids Are Invited For Glow Wire Test Apparatus To 960 Oc - Repairing, Servicing & Calibration , Endurance Test Machine For Switch With Inductive Load 40 Amp - Repairing, Servicing & Calibration , Heating Oven ( Hot Set Test Oven ) Amb. To 250Oc - Repairing, Servicing & Calibration , Dust Chamber For Ingress Protection Of Dust Test For Ip 5X / 6Xsize 2M X 1 M X 1 M - Repairing & Servicing , Apparatus For Ingress Protection Of Water Ip X3 / X4 - Repairing & Servicing , Impact Test Apparatus ( Ik Test ) Upto Ik 10 - Repairing & Servicing , Vibration Exciter Console 0.25 Hp Motor, - Repairing & Servicing , Auto Variable Transformer Output 1V – 300 V Ac - Repairing & Servicing , High Current Low Voltage Source 800 A / 6 V Lalith Test Equipment Make - Repairing & Servicing , High Current Low Voltage Source1200 A / 6 Lalith Test Equipment Make - Repairing & Servicing , Digital Vernier Caliper 0-300 Mm Mitutoyo - Repairing& Calibration , Digital Micro Ohm Meter1.9999 Milii Ohm To 1.9999 K.Ohm + / - 0.05 % - Calibration & Intermediate Check After 6 Months , Analog Million Mega Ohmmeter10 M.Ohm To 20X 106 Mohm / 500 & 1000V Dc - Calibration & Intermediate Check After 6 Months , True Rms Leakagecurrent Meter300 V / 2 Ma. - Calibration & Intermediate Check After 6 Months , Earth Resistance Test Apparatus12 V / 30 A - Calibration & Intermediate Check After 6 Months , Endurance Test Set Forswitches - Calibration & Intermediate Check After 6 Months , Digital Panel Meters Of Inductive Load For Plug & Socket 300 Vac / 30.0 Aac / 0.5 Pf Lag To Unity - Calibration & Intermediate Check After 6 Months , Digital Insulation Tester 199.9 Meg Ohm / 500V Dc - Calibration & Intermediate Check After 6 Months , Comparative Tracking Index Test Set. 750A Ac / 1.00 A Ac - Calibration & Intermediate Check After 6 Months , High Voltage Tester15 Kvac - Calibration & Intermediate Check After 6 Months , High Voltage Tester 5 Kv Ac - Calibration & Intermediate Check After 6 Months , High Voltage Tester 1.5 Kv Dc - Calibration & Intermediate Check After 6 Months , 3 Cell Ageing Oven Digital Temp. Controller Amb. To 150 Deg. C. L.C. : 0.1 Deg.C. - Calibration & Intermediate Check After 6 Months , Ageing Oven Amb. To 250 Deg. C Lc : + / - 1 Deg. C - Calibration & Intermediate Check After 6 Months , Thermal Stability Oven With Hg. In Glass Thermometer Oven :250Deg.Cglass Thermometer : 195 - 205 Deg.C. 0.1 Deg.C - Calibration & Intermediate Check After 6 Months , Profile Projectorx-Axis : 0-100 Mm Y-Axis : 0-100 Mm Magnification :20X Lc :0.005 Mm - Calibration & Intermediate Check After 6 Months , Computerized Tensile Testing Machine System500 / 5000 N - Calibration & Intermediate Check After 6 Months , Environmental Testchamber ( Cold Chamber ) - 70To 200 Deg. C. + / - 1 Deg.C. - Calibration & Intermediate Check After 6 Months , Universal Power Analyser Pm-3000A 0- 1000 V Ac, 10 - 10 Khz, 0-20 A Ac, Power Factor, 0-3.2 Kw - Calibration & Intermediate Check After 6 Months , Water Bath Upto 100 Deg.C L.C. : 0.1 Deg C - Calibration & Intermediate Check After 6 Months , Accessibility Test Control Panel ( Protection Against Electric Shock Test Apparatus ) 40 - 50 V Ac - Calibration , Digital Multimeter0-750 / 1000V Ac / Dc, 0- 10 A Ac / Dc, 0-50 M.Ohms - Calibration , Digital Thermometer250 Deg. C With Pt -100 Sensor And 1000 Deg. C With K Type Sensor - Calibration , Digital Temp. & Humidity Meter 0 To 60Deg.C / 10 To 100% Rh - Calibration , Digitalstop Watch 0- 9999 Sec Lc : 0.001S To 1S - Calibration , Electronic Weighing Balance 0 To 210 Gm L.C. :0.0001 G. - Calibration , Power Analyser Wt 310 E ( Use For Integrating Sphere ) 0- 600 V / 20 Ma - 15 A / 1 W -4 Kw - Calibration , Power Supply Ac / Dc 61603 ( Use For Integrating Sphere ) 150 / 300 Vac Auto, 15 Hz To 1 Khz - Calibration , 6 Channel Temperature Indicator0-400 Deg.C Lc : 1 Deg.C - Calibration , Test Panel For Lamp Cap Temperature Rise 0 - 300 V Ac Source L.C. : 1 V K-Type Temperature Indicator L.C. : 1 Deg. C - Calibration , Temperature Rise Test Apparatus 50 Aac, 19.99V, 199.9 Deg .C. - Calibration , Portable Power Analyser0-1000V Ac, 0-900 A Ac, 0-900 A Dc, 100 Ohm -90 Kohm - Calibration , Lux Meter0 .1 - 999990 Lux ( Calibration Up To 10000 Lux ) - Calibration , Electronic Weighing Balance15 Kg L.C. : 1 Gm - Calibration , Rotameter Water0 -120 Lpm L.C. : 2 Lpm - Calibration , Digital Rpm Meter2.5 To 30000 Rpm L.C. :0.1 / 1 Rpm - Calibration Total Quantity : 1
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Jan-2022 | 27-Jan-2022 |
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Glow Wire Test Apparatus to 960 oC | Repairing, Servicing & Calibration |
| 2 | Endurance Test Machine for Switch with Inductive Load 40 Amp | Repairing, Servicing & Calibration |
| 3 | Heating Oven (Hot set test oven)Amb. To 250oC | Repairing, Servicing & Calibration |
| 4 | Dust Chamber for Ingress protection of Dust testFor IP 5X / 6XSize 2m x 1 m x 1 m | Repairing & Servicing |
| 5 | Apparatus for Ingress protection of water IP X3 / X4 | Repairing & Servicing |
| 6 | Impact Test Apparatus (IK test) Upto IK 10 | Repairing & Servicing |
| 7 | Vibration Exciter Console 0.25 HP motor, | Repairing & Servicing |
| 8 | Auto Variable Transformer Output 1V – 300 V AC | Repairing & Servicing |
| 9 | High Current Low Voltage Source 800 A / 6 V Lalith Test Equipment make | Repairing & Servicing |
| 10 | High Current Low Voltage Source1200 A / 6 Lalith Test Equipment make | Repairing & Servicing |
| 11 | Digital Vernier Caliper0-300 mmMitutoyo | Repairing& Calibration |
| 12 | Digital Micro Ohm Meter1.9999 milii Ohm to 1.9999 k.Ohm+/- 0.05 % | Calibration & Intermediate check after 6 months |
| 13 | Analog Million Mega OhmMeter10 M.Ohm to 20x 106 Mohm/ 500 & 1000V DC | Calibration & Intermediate check after 6 months |
| 14 | True RMS LeakageCurrent Meter300 V/ 2 mA. | Calibration & Intermediate check after 6 months |
| 15 | Earth Resistance Test Apparatus12 V/30 A | Calibration & Intermediate check after 6 months |
| 16 | Endurance Test Set ForSwitches | Calibration & Intermediate check after 6 months |
| 17 | Digital Panel Meters of inductive load for Plug & Socket 300 Vac/ 30.0 AAC/ 0.5 pf lag to Unity | Calibration & Intermediate check after 6 months |
| 18 | Digital Insulation Tester 199.9 Meg ohm/ 500V DC | Calibration & Intermediate check after 6 months |
| 19 | Comparative Tracking Index Test Set. 750A AC/ 1.00 A AC | Calibration & Intermediate check after 6 months |
| 20 | High Voltage Tester15 KVAC | Calibration & Intermediate check after 6 months |
| 21 | High Voltage Tester 5 KV AC | Calibration & Intermediate check after 6 months |
| 22 | High Voltage Tester 1.5 KV DC | Calibration & Intermediate check after 6 months |
| 23 | 3 Cell Ageing Oven Digital Temp. Controller Amb. To 150 deg. C.L.C. : 0.1 deg.C. | Calibration & Intermediate check after 6 months |
| 24 | Ageing Oven Amb. To 250 deg. CLC : +/- 1 deg. C | Calibration & Intermediate check after 6 months |
| 25 | Thermal Stability Oven with Hg. In Glass Thermometer Oven :250deg.CGlass Thermometer : 195 - 205 deg.C.0.1 deg.C | Calibration & Intermediate check after 6 months |
| 26 | Profile ProjectorX-axis : 0-100 mm Y-axis : 0-100 mm Magnification :20XLC :0.005 mm | Calibration & Intermediate check after 6 months |
| 27 | Computerized Tensile Testing Machine System500/ 5000 N | Calibration & Intermediate check after 6 months |
| 28 | Environmental TestChamber (Cold Chamber) - 70to 200 deg. C. +/- 1 deg.C. | Calibration & Intermediate check after 6 months |
| 29 | Universal Power Analyser PM-3000A 0- 1000 V AC, 10 - 10 KHz, 0-20 A AC, Power factor, 0-3.2 KW | Calibration & Intermediate check after 6 months |
| 30 | Water Bath upto 100 deg.C L.C. : 0.1 deg C | Calibration & Intermediate check after 6 months |
| 31 | Accessibility test control panel (Protection against electric shock test apparatus) 40 - 50 V AC | Calibration |
| 32 | Digital Multimeter0-750/1000V AC/DC, 0- 10 A AC/DC, 0-50 M.Ohms | Calibration |
| 33 | Digital Thermometer250 deg. C with PT -100 sensor and 1000 deg. C with K type sensor | Calibration |
| 34 | Digital Temp. & Humidity Meter 0 TO 60deg.C/10 to 100% RH | Calibration |
| 35 | DigitalStop Watch 0- 9999 secLC : 0.001s to 1s | Calibration |
| 36 | Electronic Weighing Balance 0 to 210 gmL.C. :0.0001 g. | Calibration |
| 37 | Power Analyser WT 310 E ( Use for Integrating sphere)0- 600 V/ 20 mA - 15 A/1 W -4 KW | Calibration |
| 38 | Power supply AC/DC 61603(Use for Integrating sphere)150/300 VAC Auto, 15 Hz to 1 KHz | Calibration |
| 39 | 6 Channel Temperature Indicator0-400 deg.CLC : 1 deg.C | Calibration |
| 40 | Test panel for Lamp Cap Temperature Rise 0 - 300 V AC Source L.C. : 1 V K-Type Temperature Indicator L.C. : 1 deg. C | Calibration |
| 41 | Temperature Rise Test Apparatus 50 AAC, 19.99V, 199.9 deg .C. | Calibration |
| 42 | Portable Power Analyser0-1000V AC, 0-900 A AC, 0-900 A DC, 100 ohm -90 Kohm | Calibration |
| 43 | Lux Meter0 .1 - 999990 Lux (Calibration up to 10000 lux) | Calibration |
| 44 | Electronic Weighing Balance15 Kg L.C. : 1 gm | Calibration |
| 45 | Rotameter Water0 -120 lpm L.C. : 2 lpm | Calibration |
| 46 | Digital RPM meter2.5 to 30000 RPM L.C. :0.1/1 RPM | Calibration |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed