Heavy Industries and Public Enterprises Government Departments Closing in 0 days TDR #30515054

Construction Of Classrooms And Allied Facilities In Akal Academy Schools In 04 Districts ( Ferozepur, Moga, Taran Tarn And Amritsar ) In Punjab Under Pfc Csr Initiative

Issued by Government Departments · ferozepur, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Jan 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ferozepur → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Classrooms And Allied Facilities In Akal Academy Schools In 04 Districts ( Ferozepur, Moga, Taran Tarn And Amritsar ) In Punjab Under Pfc Csr Initiative

BOQ

Name of Work:Construction of classrooms & allied facilities in Akal AcademySchools in 04 Districts (Ferozepur, Moga, Taran Tarn & Amritsar) in Punjab under PFC’s CSR initiative
Sl. No. Item Description
1FIROZPUR DISTRICT
2A.RATTA KHERA (1st Floor)
3Civil Works
4Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
5Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
6Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
7shelves (cast in situ)
8lintels,beams,plinth beams,girders,bressumers and cantilevers.
9columns pillars ,piers,Abutments,posts and struts.
10Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
11Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
12Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
13Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
14Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
15Profile CFixing with adjustable lugs with split end tail to each jamb
16Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
17Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
18Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
19Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
20Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
21Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
22Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
23Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
24Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
25Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
266 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
2715 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
2812 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
29White washing with lime to give an even shade :New work (three or more coats)
30Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
31Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
32Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
33110 mm bend
34110 mm Shoe
35Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
36Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
37Supplying and applying bituminous solution primer on roof and / or wall
38Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
39Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
40ELECTRICAL
41Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
42Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
43Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
442 X 6 sq. mm + 1 X 6 sq. mm earth wire.
45Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
46Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
47Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
48Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
49MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
50Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
51Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
52Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
53ELECTRICAL- Non Scheduled Items
54LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
55Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
56B. Bharana (Ground Floor)
57Civil Works
58Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil
59Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils
60Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
61Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
62Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size)
63Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns
64Columns, piers, abutments, pillars, posts and struts
65Lintels, beams, plinth beams, girders, bressumers and cantilevers
66Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size)
67Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size)
68Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
69Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth.
70Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars
71Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
72Supplying and stacking at site- Good earth
73Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
74Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
75Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
76Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
77shelves (cast in situ)
78lintels,beams,plinth beams,girders,bressumers and cantilevers.
79columns pillars ,piers,Abutments,posts and struts.
80Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
81Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
82Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
83Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
84Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
85Profile CFixing with adjustable lugs with split end tail to each jamb
86Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
87Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
88Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
89Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
90Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
91Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
92Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
93Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
94Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
95Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
966 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
9715 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
9812 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
99White washing with lime to give an even shade :New work (three or more coats)
100Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
101Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
102Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
103110 mm bend
104110 mm Shoe
105Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
106Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
107Supplying and applying bituminous solution primer on roof and / or wall
108Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
109Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
110Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. Tube
111Electrical
112Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
113Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
114Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1152 X 6 sq. mm + 1 X 6 sq. mm earth wire.
116Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
117Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
118Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
119Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
120MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
121Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
122Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
123Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
124Electrical- Non Scheduled Items
125LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
126Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
127C. BEHEK FATTU (Ground Floor)
128Civil Works
129Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil
130Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils
131Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
132Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
133Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size)
134Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns
135Columns, piers, abutments, pillars, posts and struts
136Lintels, beams, plinth beams, girders, bressumers and cantilevers
137Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size)
138Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size)
139Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
140Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth.
141Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars
142Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
143Supplying and stacking at site- Good earth
144Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
145Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
146Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
147Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
148shelves (cast in situ)
149lintels,beams,plinth beams,girders,bressumers and cantilevers.
150columns pillars ,piers,Abutments,posts and struts.
151Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
152Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
153Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
154Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
155Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
156Profile CFixing with adjustable lugs with split end tail to each jamb
157Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
158Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
159Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
160Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
161Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
162Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
163Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
164Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
165Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
166Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
1676 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
16815 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
16912 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
170White washing with lime to give an even shade :New work (three or more coats)
171Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
172Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
173Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
174110 mm bend
175110 mm Shoe
176Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
177Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
178Supplying and applying bituminous solution primer on roof and / or wall
179Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
180Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
181Electrical
182Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
183Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
184Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1852 X 6 sq. mm + 1 X 6 sq. mm earth wire.
186Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
187Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
188Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
189Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
190MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
191Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
192Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
193Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
194Electrical- Non Scheduled Items
195LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
196Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
197D. Nawan Quila (2nd Floor)
198Civil Works
199Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
200Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
201Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
202Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
203shelves (cast in situ)
204lintels,beams,plinth beams,girders,bressumers and cantilevers.
205columns pillars ,piers,Abutments,posts and struts.
206Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
207Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
208Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
209Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
210Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
211Profile CFixing with adjustable lugs with split end tail to each jamb
212Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
213Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
214Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
215Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
216Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
217Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
218Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
219Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
220Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
221Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
2226 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
22315 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
22412 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
225White washing with lime to give an even shade :New work (three or more coats)
226Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
227Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
228Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
229110 mm bend
230110 mm Shoe
231Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
232Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
233Supplying and applying bituminous solution primer on roof and / or wall
234Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
235Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
236Electrical
237Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
238Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
239Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2402 X 6 sq. mm + 1 X 6 sq. mm earth wire.
241Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
242Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
243Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
244Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
245MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
246Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
247Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
248Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
249Electrical- Non Scheduled Items
250LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
251Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
252E. Talwandi Nipala (3rd Floor)
253Civil Works
254Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
255Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
256Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
257Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
258shelves (cast in situ)
259lintels,beams,plinth beams,girders,bressumers and cantilevers.
260columns pillars ,piers,Abutments,posts and struts.
261Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
262Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
263Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
264Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
265Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
266Profile CFixing with adjustable lugs with split end tail to each jamb
267Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
268Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
269Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
270Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
271Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
272Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
273Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
274Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
275Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
276Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
2776 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
27815 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
27912 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
280White washing with lime to give an even shade :New work (three or more coats)
281Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
282Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
283Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
284110 mm bend
285110 mm Shoe
286Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
287Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
288Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
289Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
290Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
291Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube
292Electrical
293Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
294Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
295Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2962 X 6 sq. mm + 1 X 6 sq. mm earth wire.
297Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
298Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
299Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
300Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
301MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
302Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
303Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
304Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
305Electrical- Non Scheduled Items
306LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
307Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
308MOGA DISTRICT
309F. Rattian (First Floor)
310Civil Works
311Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
312Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
313Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
314Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
315shelves (cast in situ)
316lintels,beams,plinth beams,girders,bressumers and cantilevers.
317columns pillars ,piers,Abutments,posts and struts.
318Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
319Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
320Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
321Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
322Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
323Profile CFixing with adjustable lugs with split end tail to each jamb
324Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
325Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
326Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
327Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
328Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
329Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
330Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
331Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
332Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
333Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
3346 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
33515 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
33612 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
337White washing with lime to give an even shade :New work (three or more coats)
338Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
339Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
340Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
341110 mm bend
342110 mm Shoe
343Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
344Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
345Supplying and applying bituminous solution primer on roof and / or wall
346Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
347Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
348Electrical
349Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
350Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
351Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3522 X 6 sq. mm + 1 X 6 sq. mm earth wire.
353Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
354Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
355Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
356Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
357MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
358Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
359Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
360Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
361Electrical- Non Scheduled Items
362LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
363Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
364G. Bakarwala (Ground floor)
365Civil Works
366Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil
367Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils
368Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
369Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
370Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size)
371Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns
372Columns, piers, abutments, pillars, posts and struts
373Lintels, beams, plinth beams, girders, bressumers and cantilevers
374Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size)
375Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size)
376Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
377Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth.
378Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars
379Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
380Supplying and stacking at site- Good earth
381Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
382Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
383Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
384Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
385shelves (cast in situ)
386lintels,beams,plinth beams,girders,bressumers and cantilevers.
387columns pillars ,piers,Abutments,posts and struts.
388Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
389Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
390Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
391Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
392Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
393Profile CFixing with adjustable lugs with split end tail to each jamb
394Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
395Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
396Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
397Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
398Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
399Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
400Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
401Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
402Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
403Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
4046 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
40515 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
40612 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
407White washing with lime to give an even shade :New work (three or more coats)
408Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
409Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
410Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
411110 mm bend
412110 mm Shoe
413Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
414Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
415Supplying and applying bituminous solution primer on roof and / or wall
416Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
417Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
418Electrical
419Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
420Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
421Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4222 X 6 sq. mm + 1 X 6 sq. mm earth wire.
423Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
424Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
425Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
426Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
427MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
428Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
429Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
430Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
431Electrical- Non Scheduled Items
432LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
433Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
434H. Jhandiana (Ground floor)
435Civil Works
436Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil
437Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils
438Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
439Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
440Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size)
441Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns
442Columns, piers, abutments, pillars, posts and struts
443Lintels, beams, plinth beams, girders, bressumers and cantilevers
444Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size)
445Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size)
446Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
447Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth.
448Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars
449Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
450Supplying and stacking at site- Good earth
451Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
452Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
453Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
454Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
455shelves (cast in situ)
456lintels,beams,plinth beams,girders,bressumers and cantilevers.
457columns pillars ,piers,Abutments,posts and struts.
458Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
459Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
460Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
461Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
462Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
463Profile CFixing with adjustable lugs with split end tail to each jamb
464Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
465Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
466Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
467Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
468Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
469Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
470Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
471Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
472Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
473Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
4746 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
47515 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
47612 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
477White washing with lime to give an even shade :New work (three or more coats)
478Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
479Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
480Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
481110 mm bend
482110 mm Shoe
483Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
484Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
485Supplying and applying bituminous solution primer on roof and / or wall
486Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
487Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
488Electrical
489Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
490Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
491Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4922 X 6 sq. mm + 1 X 6 sq. mm earth wire.
493Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
494Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
495Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
496Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
497MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
498Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
499Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
500Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
501Electrical- Non Scheduled Items
502LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
503Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
504I. Manawan (2nd Floor)
505Civil Works
506Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
507Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
508Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
509Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
510shelves (cast in situ)
511lintels,beams,plinth beams,girders,bressumers and cantilevers.
512columns pillars ,piers,Abutments,posts and struts.
513Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
514Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
515Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
516Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
517Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
518Profile CFixing with adjustable lugs with split end tail to each jamb
519Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
520Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
521Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
522Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
523Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
524Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
525Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
526Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
527Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
528Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
5296 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
53015 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
53112 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
532White washing with lime to give an even shade :New work (three or more coats)
533Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
534Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
535Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
536110 mm bend
537110 mm Shoe
538Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
539Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
540Supplying and applying bituminous solution primer on roof and / or wall
541Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
542Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
543Electrical
544Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
545Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
546Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
5472 X 6 sq. mm + 1 X 6 sq. mm earth wire.
548Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
549Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
550Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
551Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
552MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
553Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
554Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
555Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
556Electrical- Non Scheduled Items
557LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
558Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
559J. Puranewala (1st Floor)
560Civil Works
561Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
562Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
563Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
564Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
565shelves (cast in situ)
566lintels,beams,plinth beams,girders,bressumers and cantilevers.
567columns pillars ,piers,Abutments,posts and struts.
568Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
569Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
570Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
571Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
572Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
573Profile CFixing with adjustable lugs with split end tail to each jamb
574Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
575Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
576Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
577Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
578Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
579Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
580Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
581Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
582Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
583Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
5846 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
58515 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
58612 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
587White washing with lime to give an even shade :New work (three or more coats)
588Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
589Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
590Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
591110 mm bend
592110 mm Shoe
593Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
594Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
595Supplying and applying bituminous solution primer on roof and / or wall
596Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
597Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
598Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube
599Electrical
600Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
601Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
602Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
6032 X 6 sq. mm + 1 X 6 sq. mm earth wire.
604Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
605Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
606Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
607Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
608MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
609Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
610Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
611Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
612Electrical- Non Scheduled Items
613LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
614Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
615AMRITSAR
616K. Basarke (3rd Floor)
617Civil Works
618Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
619Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
620Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
621Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
622shelves (cast in situ)
623lintels,beams,plinth beams,girders,bressumers and cantilevers.
624columns pillars ,piers,Abutments,posts and struts.
625Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
626Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
627Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
628Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
629Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
630Profile CFixing with adjustable lugs with split end tail to each jamb
631Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
632Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
633Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
634Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
635Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
636Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
637Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
638Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
639Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
640Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
6416 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
64215 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
64312 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
644White washing with lime to give an even shade :New work (three or more coats)
645Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
646Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
647Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
648110 mm bend
649110 mm Shoe
650Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
651Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
652Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
653Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
654Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
655Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube
656Electrical
657Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
658Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
659Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
6602 X 6 sq. mm + 1 X 6 sq. mm earth wire.
661Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
662Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
663Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
664Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
665MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
666Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
667Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
668Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
669Electrical- Non Scheduled Items
670LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
671Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
672L. Vachhoya (Ground floor)
673Civil Works
674Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil
675Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils
676Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
677Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
678Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size)
679Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns
680Columns, piers, abutments, pillars, posts and struts
681Lintels, beams, plinth beams, girders, bressumers and cantilevers
682Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size)
683Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size)
684Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
685Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth.
686Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars
687Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
688Supplying and stacking at site- Good earth
689Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
690Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
691Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
692Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
693shelves (cast in situ)
694lintels,beams,plinth beams,girders,bressumers and cantilevers.
695columns pillars ,piers,Abutments,posts and struts.
696Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
697Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
698Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
699Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
700Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
701Profile CFixing with adjustable lugs with split end tail to each jamb
702Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
703Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
704Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
705Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
706Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
707Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
708Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
709Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
710Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
711Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
7126 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
71315 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
71412 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
715White washing with lime to give an even shade :New work (three or more coats)
716Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
717Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
718Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
719110 mm bend
720110 mm Shoe
721Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
722Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
723Supplying and applying bituminous solution primer on roof and / or wall
724Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
725Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
726Electrical
727Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
728Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
729Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
7302 X 6 sq. mm + 1 X 6 sq. mm earth wire.
731Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
732Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
733Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
734Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
735MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
736Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
737Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
738Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
739Electrical- Non Scheduled Items
740LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
741Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
742TARN TARAN
743M. Dhotian (Ground floor)
744Civil Works
745Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil
746Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils
747Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
748Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
749Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size)
750Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns
751Columns, piers, abutments, pillars, posts and struts
752Lintels, beams, plinth beams, girders, bressumers and cantilevers
753Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size)
754Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size)
755Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
756Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth.
757Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars
758Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
759Supplying and stacking at site- Good earth
760Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
761Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
762Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
763Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
764shelves (cast in situ)
765lintels,beams,plinth beams,girders,bressumers and cantilevers.
766columns pillars ,piers,Abutments,posts and struts.
767Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
768Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
769Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
770Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
771Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
772Profile CFixing with adjustable lugs with split end tail to each jamb
773Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
774Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
775Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
776Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
777Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
778Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
779Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
780Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
781Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
782Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
7836 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
78415 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
78512 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
786White washing with lime to give an even shade :New work (three or more coats)
787Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
788Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
789Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
790110 mm bend
791110 mm Shoe
792Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
793Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
794Supplying and applying bituminous solution primer on roof and / or wall
795Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
796Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
797Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube
798Electrical
799Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
800Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
801Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
8022 X 6 sq. mm + 1 X 6 sq. mm earth wire.
803Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
804Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
805Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
806Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
807MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
808Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
809Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
810Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
811Electrical- Non Scheduled Items
812LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
813Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
814N. Teja Singh Wala (2nd Floor)
815Civil Works
816Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
817Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
818Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
819Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
820shelves (cast in situ)
821lintels,beams,plinth beams,girders,bressumers and cantilevers.
822columns pillars ,piers,Abutments,posts and struts.
823Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
824Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
825Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
826Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
827Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
828Profile CFixing with adjustable lugs with split end tail to each jamb
829Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
830Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
831Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
832Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
833Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
834Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
835Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
836Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
837Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
838Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
8396 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
84015 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
84112 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
842White washing with lime to give an even shade :New work (three or more coats)
843Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
844Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
845Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
846110 mm bend
847110 mm Shoe
848Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
849Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
850Supplying and applying bituminous solution primer on roof and / or wall
851Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
852Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
853Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube
854Electrical
855Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
856Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
857Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
8582 X 6 sq. mm + 1 X 6 sq. mm earth wire.
859Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
860Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
861Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
862Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
863MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
864Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
865Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
866Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
867Electrical- Non Scheduled Items
868LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
869Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.
870O. Dadehar Sahib (3rd Floor)
871Civil Works
872Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
873Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
874Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars.
875Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms
876shelves (cast in situ)
877lintels,beams,plinth beams,girders,bressumers and cantilevers.
878columns pillars ,piers,Abutments,posts and struts.
879Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand)
880Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand)
881Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
882Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
883Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb
884Profile CFixing with adjustable lugs with split end tail to each jamb
885Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
886Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
887Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
888Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
889Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
890Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete.
891Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm
892Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
893Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm
894Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm
8956 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand )
89615 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand )
89712 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
898White washing with lime to give an even shade :New work (three or more coats)
899Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
900Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
901Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
902110 mm bend
903110 mm Shoe
904Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
905Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm
906Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
907Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size)
908Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
909Electrical
910Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
911Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
912Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
9132 X 6 sq. mm + 1 X 6 sq. mm earth wire.
914Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required.
915Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
916Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
917Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
918MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door
919Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole
920Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
921Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing.
922Electrical- Non Scheduled Items
923LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light
924Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.

AI Tender Summary

OUR REF NO 30515054
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 10-01-2022
Authority
Authority Name Hindustan Prefab Limited
Work Description Construction Of Classrooms And Allied Facilities In Akal Academy Schools In 04 Districts ( Ferozepur, Moga, Taran Tarn And Amritsar ) In Punjab Under Pfc Csr Initiative
Basic Detail
Tender No HPL/PM(C)/TC/PFCL-KDT /Punjab /2021-22/26
Bidding Type Tender
Location
City ferozepur
State Punjab
Key Dates
Publish Date 30 Dec 2021
Submission Date 10 Jan 2022
Open Date 11 Jan 2022
Finance
Tender Value Ref. Documents
Tender Fee 5900
EMD Ref. Documents
Exemption Not Available
Document List
BOQ_108980.xls
TechnicalBid.xls
TenderDocuments.pdf
Tendernotice_1.pdf
7dd690c1-2257-4853-ab77-b48408f400ce.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 30, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 10, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 11, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents