| Sl. No. | Item Description |
| 1 | FIROZPUR DISTRICT |
| 2 | A.RATTA KHERA (1st Floor) |
| 3 | Civil Works |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 6 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 7 | shelves (cast in situ) |
| 8 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 9 | columns pillars ,piers,Abutments,posts and struts. |
| 10 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 11 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 12 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 13 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 14 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 15 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 17 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 18 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 19 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 20 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 21 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 22 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 23 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 24 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 25 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 26 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 27 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 28 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 29 | White washing with lime to give an even shade :New work (three or more coats) |
| 30 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 31 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 32 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 33 | 110 mm bend |
| 34 | 110 mm Shoe |
| 35 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 36 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 37 | Supplying and applying bituminous solution primer on roof and / or wall |
| 38 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 39 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 40 | ELECTRICAL |
| 41 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 42 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 43 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 44 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 45 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 46 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 47 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 48 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 49 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 50 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 51 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 52 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 53 | ELECTRICAL- Non Scheduled Items |
| 54 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 55 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 56 | B. Bharana (Ground Floor) |
| 57 | Civil Works |
| 58 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil |
| 59 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils |
| 60 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 61 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 62 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 63 | Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns |
| 64 | Columns, piers, abutments, pillars, posts and struts |
| 65 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 66 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size) |
| 67 | Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size) |
| 68 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 69 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth. |
| 70 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars |
| 71 | Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 72 | Supplying and stacking at site- Good earth |
| 73 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 74 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 75 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 76 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 77 | shelves (cast in situ) |
| 78 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 79 | columns pillars ,piers,Abutments,posts and struts. |
| 80 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 81 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 82 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 83 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 84 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 85 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 86 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 87 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 88 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 89 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 90 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 91 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 92 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 93 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 94 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 95 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 96 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 97 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 98 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 99 | White washing with lime to give an even shade :New work (three or more coats) |
| 100 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 101 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 102 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 103 | 110 mm bend |
| 104 | 110 mm Shoe |
| 105 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 106 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 107 | Supplying and applying bituminous solution primer on roof and / or wall |
| 108 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 109 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 110 | Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. Tube |
| 111 | Electrical |
| 112 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 113 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 114 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 115 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 116 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 117 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 118 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 119 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 120 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 121 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 122 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 123 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 124 | Electrical- Non Scheduled Items |
| 125 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 126 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 127 | C. BEHEK FATTU (Ground Floor) |
| 128 | Civil Works |
| 129 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil |
| 130 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils |
| 131 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 132 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 133 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 134 | Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns |
| 135 | Columns, piers, abutments, pillars, posts and struts |
| 136 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 137 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size) |
| 138 | Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size) |
| 139 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 140 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth. |
| 141 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars |
| 142 | Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 143 | Supplying and stacking at site- Good earth |
| 144 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 145 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 146 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 147 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 148 | shelves (cast in situ) |
| 149 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 150 | columns pillars ,piers,Abutments,posts and struts. |
| 151 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 152 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 153 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 154 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 155 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 156 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 157 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 158 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 159 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 160 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 161 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 162 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 163 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 164 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 165 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 166 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 167 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 168 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 169 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 170 | White washing with lime to give an even shade :New work (three or more coats) |
| 171 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 172 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 173 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 174 | 110 mm bend |
| 175 | 110 mm Shoe |
| 176 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 177 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 178 | Supplying and applying bituminous solution primer on roof and / or wall |
| 179 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 180 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 181 | Electrical |
| 182 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 183 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 184 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 185 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 186 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 187 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 188 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 189 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 190 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 191 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 192 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 193 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 194 | Electrical- Non Scheduled Items |
| 195 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 196 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 197 | D. Nawan Quila (2nd Floor) |
| 198 | Civil Works |
| 199 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 200 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 201 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 202 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 203 | shelves (cast in situ) |
| 204 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 205 | columns pillars ,piers,Abutments,posts and struts. |
| 206 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 207 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 208 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 209 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 210 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 211 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 212 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 213 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 214 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 215 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 216 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 217 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 218 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 219 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 220 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 221 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 222 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 223 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 224 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 225 | White washing with lime to give an even shade :New work (three or more coats) |
| 226 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 227 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 228 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 229 | 110 mm bend |
| 230 | 110 mm Shoe |
| 231 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 232 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 233 | Supplying and applying bituminous solution primer on roof and / or wall |
| 234 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 235 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 236 | Electrical |
| 237 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 238 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 239 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 240 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 241 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 242 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 243 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 244 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 245 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 246 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 247 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 248 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 249 | Electrical- Non Scheduled Items |
| 250 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 251 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 252 | E. Talwandi Nipala (3rd Floor) |
| 253 | Civil Works |
| 254 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 255 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 256 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 257 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 258 | shelves (cast in situ) |
| 259 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 260 | columns pillars ,piers,Abutments,posts and struts. |
| 261 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 262 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 263 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 264 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 265 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 266 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 267 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 268 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 269 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 270 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 271 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 272 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 273 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 274 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 275 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 276 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 277 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 278 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 279 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 280 | White washing with lime to give an even shade :New work (three or more coats) |
| 281 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 282 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 283 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 284 | 110 mm bend |
| 285 | 110 mm Shoe |
| 286 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 287 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 288 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 289 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 290 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 291 | Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube |
| 292 | Electrical |
| 293 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 294 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 295 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 296 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 297 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 298 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 299 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 300 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 301 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 302 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 303 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 304 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 305 | Electrical- Non Scheduled Items |
| 306 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 307 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 308 | MOGA DISTRICT |
| 309 | F. Rattian (First Floor) |
| 310 | Civil Works |
| 311 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 312 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 313 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 314 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 315 | shelves (cast in situ) |
| 316 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 317 | columns pillars ,piers,Abutments,posts and struts. |
| 318 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 319 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 320 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 321 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 322 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 323 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 324 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 325 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 326 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 327 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 328 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 329 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 330 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 331 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 332 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 333 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 334 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 335 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 336 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 337 | White washing with lime to give an even shade :New work (three or more coats) |
| 338 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 339 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 340 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 341 | 110 mm bend |
| 342 | 110 mm Shoe |
| 343 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 344 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 345 | Supplying and applying bituminous solution primer on roof and / or wall |
| 346 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 347 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 348 | Electrical |
| 349 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 350 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 351 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 352 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 353 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 354 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 355 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 356 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 357 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 358 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 359 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 360 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 361 | Electrical- Non Scheduled Items |
| 362 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 363 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 364 | G. Bakarwala (Ground floor) |
| 365 | Civil Works |
| 366 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil |
| 367 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils |
| 368 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 369 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 370 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 371 | Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns |
| 372 | Columns, piers, abutments, pillars, posts and struts |
| 373 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 374 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size) |
| 375 | Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size) |
| 376 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 377 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth. |
| 378 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars |
| 379 | Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 380 | Supplying and stacking at site- Good earth |
| 381 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 382 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 383 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 384 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 385 | shelves (cast in situ) |
| 386 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 387 | columns pillars ,piers,Abutments,posts and struts. |
| 388 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 389 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 390 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 391 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 392 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 393 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 394 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 395 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 396 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 397 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 398 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 399 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 400 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 401 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 402 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 403 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 404 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 405 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 406 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 407 | White washing with lime to give an even shade :New work (three or more coats) |
| 408 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 409 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 410 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 411 | 110 mm bend |
| 412 | 110 mm Shoe |
| 413 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 414 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 415 | Supplying and applying bituminous solution primer on roof and / or wall |
| 416 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 417 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 418 | Electrical |
| 419 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 420 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 421 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 422 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 423 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 424 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 425 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 426 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 427 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 428 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 429 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 430 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 431 | Electrical- Non Scheduled Items |
| 432 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 433 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 434 | H. Jhandiana (Ground floor) |
| 435 | Civil Works |
| 436 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil |
| 437 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils |
| 438 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 439 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 440 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 441 | Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns |
| 442 | Columns, piers, abutments, pillars, posts and struts |
| 443 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 444 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size) |
| 445 | Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size) |
| 446 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 447 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth. |
| 448 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars |
| 449 | Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 450 | Supplying and stacking at site- Good earth |
| 451 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 452 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 453 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 454 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 455 | shelves (cast in situ) |
| 456 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 457 | columns pillars ,piers,Abutments,posts and struts. |
| 458 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 459 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 460 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 461 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 462 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 463 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 464 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 465 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 466 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 467 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 468 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 469 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 470 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 471 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 472 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 473 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 474 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 475 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 476 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 477 | White washing with lime to give an even shade :New work (three or more coats) |
| 478 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 479 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 480 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 481 | 110 mm bend |
| 482 | 110 mm Shoe |
| 483 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 484 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 485 | Supplying and applying bituminous solution primer on roof and / or wall |
| 486 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 487 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 488 | Electrical |
| 489 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 490 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 491 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 492 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 493 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 494 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 495 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 496 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 497 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 498 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 499 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 500 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 501 | Electrical- Non Scheduled Items |
| 502 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 503 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 504 | I. Manawan (2nd Floor) |
| 505 | Civil Works |
| 506 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 507 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 508 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 509 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 510 | shelves (cast in situ) |
| 511 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 512 | columns pillars ,piers,Abutments,posts and struts. |
| 513 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 514 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 515 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 516 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 517 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 518 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 519 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 520 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 521 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 522 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 523 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 524 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 525 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 526 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 527 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 528 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 529 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 530 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 531 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 532 | White washing with lime to give an even shade :New work (three or more coats) |
| 533 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 534 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 535 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 536 | 110 mm bend |
| 537 | 110 mm Shoe |
| 538 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 539 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 540 | Supplying and applying bituminous solution primer on roof and / or wall |
| 541 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 542 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 543 | Electrical |
| 544 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 545 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 546 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 547 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 548 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 549 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 550 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 551 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 552 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 553 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 554 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 555 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 556 | Electrical- Non Scheduled Items |
| 557 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 558 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 559 | J. Puranewala (1st Floor) |
| 560 | Civil Works |
| 561 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 562 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 563 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 564 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 565 | shelves (cast in situ) |
| 566 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 567 | columns pillars ,piers,Abutments,posts and struts. |
| 568 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 569 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 570 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 571 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 572 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 573 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 574 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 575 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 576 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 577 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 578 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 579 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 580 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 581 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 582 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 583 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 584 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 585 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 586 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 587 | White washing with lime to give an even shade :New work (three or more coats) |
| 588 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 589 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 590 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 591 | 110 mm bend |
| 592 | 110 mm Shoe |
| 593 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 594 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 595 | Supplying and applying bituminous solution primer on roof and / or wall |
| 596 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 597 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 598 | Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube |
| 599 | Electrical |
| 600 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 601 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 602 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 603 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 604 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 605 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 606 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 607 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 608 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 609 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 610 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 611 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 612 | Electrical- Non Scheduled Items |
| 613 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 614 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 615 | AMRITSAR |
| 616 | K. Basarke (3rd Floor) |
| 617 | Civil Works |
| 618 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 619 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 620 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 621 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 622 | shelves (cast in situ) |
| 623 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 624 | columns pillars ,piers,Abutments,posts and struts. |
| 625 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 626 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 627 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 628 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 629 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 630 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 631 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 632 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 633 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 634 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 635 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 636 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 637 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 638 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 639 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 640 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 641 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 642 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 643 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 644 | White washing with lime to give an even shade :New work (three or more coats) |
| 645 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 646 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 647 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 648 | 110 mm bend |
| 649 | 110 mm Shoe |
| 650 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 651 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 652 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 653 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 654 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 655 | Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube |
| 656 | Electrical |
| 657 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 658 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 659 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 660 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 661 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 662 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 663 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 664 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 665 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 666 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 667 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 668 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 669 | Electrical- Non Scheduled Items |
| 670 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 671 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 672 | L. Vachhoya (Ground floor) |
| 673 | Civil Works |
| 674 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil |
| 675 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils |
| 676 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 677 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 678 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 679 | Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns |
| 680 | Columns, piers, abutments, pillars, posts and struts |
| 681 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 682 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size) |
| 683 | Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size) |
| 684 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 685 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth. |
| 686 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars |
| 687 | Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 688 | Supplying and stacking at site- Good earth |
| 689 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 690 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 691 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 692 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 693 | shelves (cast in situ) |
| 694 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 695 | columns pillars ,piers,Abutments,posts and struts. |
| 696 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 697 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 698 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 699 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 700 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 701 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 702 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 703 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 704 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 705 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 706 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 707 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 708 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 709 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 710 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 711 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 712 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 713 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 714 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 715 | White washing with lime to give an even shade :New work (three or more coats) |
| 716 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 717 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 718 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 719 | 110 mm bend |
| 720 | 110 mm Shoe |
| 721 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 722 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 723 | Supplying and applying bituminous solution primer on roof and / or wall |
| 724 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 725 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 726 | Electrical |
| 727 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 728 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 729 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 730 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 731 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 732 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 733 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 734 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 735 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 736 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 737 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 738 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 739 | Electrical- Non Scheduled Items |
| 740 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 741 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 742 | TARN TARAN |
| 743 | M. Dhotian (Ground floor) |
| 744 | Civil Works |
| 745 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kind of soil |
| 746 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kind of soils |
| 747 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 748 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 749 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) |
| 750 | Centering and shuttering including strutting, propping etc. and removal of formwork for :Foundations, footings, bases for columns |
| 751 | Columns, piers, abutments, pillars, posts and struts |
| 752 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 753 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All workup to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mmnominal size) |
| 754 | Providing and laying damp-proof course 40mm thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mmnominal size) |
| 755 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 756 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling &dressing & finishing the top smooth. |
| 757 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo Mechanically Treated Bars |
| 758 | Brick work with common burnt clay modular bricks of class designation 7.5 infoundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 759 | Supplying and stacking at site- Good earth |
| 760 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 761 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 762 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 763 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 764 | shelves (cast in situ) |
| 765 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 766 | columns pillars ,piers,Abutments,posts and struts. |
| 767 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 768 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 769 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 770 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 771 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 772 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 773 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 774 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 775 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 776 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 777 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 778 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 779 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 780 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 781 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 782 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 783 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 784 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 785 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 786 | White washing with lime to give an even shade :New work (three or more coats) |
| 787 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 788 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 789 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 790 | 110 mm bend |
| 791 | 110 mm Shoe |
| 792 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 793 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 794 | Supplying and applying bituminous solution primer on roof and / or wall |
| 795 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 796 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 797 | Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube |
| 798 | Electrical |
| 799 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 800 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 801 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 802 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 803 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 804 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 805 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 806 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 807 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 808 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 809 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 810 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 811 | Electrical- Non Scheduled Items |
| 812 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 813 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 814 | N. Teja Singh Wala (2nd Floor) |
| 815 | Civil Works |
| 816 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 817 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 818 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 819 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 820 | shelves (cast in situ) |
| 821 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 822 | columns pillars ,piers,Abutments,posts and struts. |
| 823 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 824 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 825 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 826 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 827 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 828 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 829 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 830 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 831 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 832 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 833 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 834 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 835 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 836 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 837 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 838 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 839 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 840 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 841 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 842 | White washing with lime to give an even shade :New work (three or more coats) |
| 843 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 844 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 845 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 846 | 110 mm bend |
| 847 | 110 mm Shoe |
| 848 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 849 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 850 | Supplying and applying bituminous solution primer on roof and / or wall |
| 851 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 852 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 853 | Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approved steel primer.M.S. tube |
| 854 | Electrical |
| 855 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 856 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 857 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 858 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 859 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 860 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 861 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 862 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 863 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 864 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 865 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 866 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 867 | Electrical- Non Scheduled Items |
| 868 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 869 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |
| 870 | O. Dadehar Sahib (3rd Floor) |
| 871 | Civil Works |
| 872 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 873 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 874 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo Mechanically treated bars. |
| 875 | Centering and shuttering including strutting ,propping etc. and removal of form for all works at all levels. Suspended floors,roofs,landing,balconies and access platforms |
| 876 | shelves (cast in situ) |
| 877 | lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 878 | columns pillars ,piers,Abutments,posts and struts. |
| 879 | Brick work with common burnt clayF.P.S (non modular)brick of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and size in:Cement mortar 1:6(1cement: 6 coarse sand) |
| 880 | Half brick masonry with common burnt clay F.P.S.( non modular ) brick of class designation 7.5 in superstructure above plinth level up to floor V level .Cement mortar 1:4(1cement: 4 coarse sand) |
| 881 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 882 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 883 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with adjustable lugs with split end tail to each jamb |
| 884 | Profile CFixing with adjustable lugs with split end tail to each jamb |
| 885 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 886 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes |
| 887 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 888 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 889 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 890 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI ,IS : 3564 embossed on the body ,door weight upto 35 kg and door width upto 700 mm) with necessary and screws etc. complete. |
| 891 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete250*10 mm |
| 892 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 893 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600x600 mm |
| 894 | Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joint with whitecement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 895 | 6 mm cement plaster to ceiling of mix 1:3 (cement :3 fine sand)1:3(1 cement : 3 fine sand ) |
| 896 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:6(1 cement : 6 Coarse sand ) |
| 897 | 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand) |
| 898 | White washing with lime to give an even shade :New work (three or more coats) |
| 899 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 900 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 901 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 902 | 110 mm bend |
| 903 | 110 mm Shoe |
| 904 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 905 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)Avg thickness 30 mm |
| 906 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 907 | Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level, excludingthe cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mmnominal size) |
| 908 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.1In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 909 | Electrical |
| 910 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 911 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 912 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 913 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 914 | Supplying and fixing two module stepped type electronic fan regulator on the existingplate switch box including connections but excluding modular plate etc. as required. |
| 915 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 916 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 917 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of suitable length (upto 0.75m) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 918 | MCCB, MCB & DB\"SSupplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 919 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.Single Pole |
| 920 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps |
| 921 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent toshape as per standard drawing. |
| 922 | Electrical- Non Scheduled Items |
| 923 | LIGHT FIXTURESSupplying, Installation, testing,commissioning, receiving the lighting fixture& fan including assembling etc. of the following lighting fixtures including fixing arrangement and with all accessories as required with necessary GI pipe/steel pipe etc as required for hanging of lighting fixtures.Supplyinging, instalation, testing & commissioning of All fixtures shall be complete with lamps and required control gear.All LED fixtures shall be complete with control gear & power factor improvement capacitor. For dimmable fixtures, HF dimmable electronic ballast to be used.Samples of all the fixtures with all available colour shall be submitted to the Engineer -in-charge before Supplying & approval is taken.Please check the fixtures final quantity from the Engineer-in-charge before ordering and be sure of actual requirement prior to ordering. 1x upto 20W LED Surface mounted Batten Light |
| 924 | Supplying of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. |