Supplying of Various Types of Testing Instruments for District Quality Control Laboratory Under Vigilance Quality Control Circle, Nashik, Tal. Dist. Nashik Supplying Of Various Types Of Testing Instruments For District Quality Control Laboratory Under Vi
Tender Overview
Project Description
Supplying of Various Types of Testing Instruments for District Quality Control Laboratory Under Vigilance Quality Control Circle, Nashik, Tal. Dist. Nashik Supplying Of Various Types Of Testing Instruments For District Quality Control Laboratory Under Vigilance Quality Control Circle, Nashik, Tal. Dist. Nashik , Concrete Flexural Strength Machine (Is. 516 : 1959, Fig. 3, Page No. 19) , Concrete Permiability Tester(Permiability Apparatus As Per Clause 3 Of Is : 3085 (1965) Fig. 2 And 3) , Field Test Cbr With Providing Ring(Cbr Test Apparatus Is : 2720 (Part 31) 1998, Clause 4, Fig. 1, Page No. 3) , Hardness Tester For Bitumen Mastic Asphalt With Accessories (As Per Clause E-2, Fig. 4 (Page No. 9) Of Is 1195:2002) , Thin Film Oven (Is : 1212-1978, Clause 3, Fig. Page No. 98) , App. For Determination Of Residue On Evaporation Apparatus : 600 Micron Is Sieve : A Circular Sieve Approximately 100 Mm. In Diameter And 40 Mm. Height. Metal Or Glass Dish : A Small Metal Or Glass Dish Above 110 Mm. In Diameter (Such As A Clock Glass) Oven : A Well Ventilated Oven Thermostatitically Controlled To 100 To 110 Degree C. Balances : One Of Capacity 250 G. And Accuracy Of 0.01 G And One Of Capacity 10 Kg. And Accuracy Of 1 G. Container : A Clean, Weighed, 1.5 Litre Container. Solution : Distilled Water. Solvents : Xylene And Acetone. , Particle Charge Tester Apparatus : Current Source : A 12 V. Battery. Rheostat : Of 2000 Ohm Capacity. Ammeter : Of 0.1 Ampere Capacity. Stainless Steel Plates : Two, 25 Mm. X 75 Mm. Size.Glass Container : Of 500 Ml. Capacity. , Ph Meter Table Top (As Per Is 2711 (1979) , Water Testing Kit Sulphateas Per Is 3025 (Part 24) Apparatus – Steam Bath.Drying Oven : Equipped With Thermostatic Control. Muffle Furnace : With Heat Indicator.Disiccator. Analytical Balance : Capable Of Weighing To 0.1 Mg.Filter Paper : Acid Washed, Ashless Hard Finish Filter Paper Sufficiently Retentive For Fine Precipitates (Preferably Whatman No. 42) Crucible : Porous Bottom Silica Or Porcelain Crucible With A Maximum Pore Size Of 5 Microns , Water Testing Kit Chloride (As Per Is 3025 (Part 32) Apparatus : Erlenmeyer Flask – 250 Ml. , Retro Reflectometer (As Per Is) , Benkleman Beam With Dial Gauge(As Per Irc : 81-1997 Cl. 3.2 Benkelman Beam Consists Of A Slender Beam 3.66 M. Long Pivoted At A Distance Of 2.44 M. From Tip (See Fig. 1 Of Irc : 81-1997 Page No. 4) , Cold Water Bath App. (Is : 1203 – 1978 Clause 3.3) , Apparatus For Distillation Of Paving Bitumen (As Per Ip 27, Is 1213 Astm D402 Method A Complete With One Distillation Flask Of 500 Ml. Capacity And One 100 Ml. Crow Receiver (Without Thermometer) Electrically Heated Model With Energy Regulator).
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Jan-2022 | Corrig.No.1 | Date | 20-Jan-2022 |
| 2 | 21-Jan-2022 | Corrig.No.2 | Date | 31-Jan-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Concrete Flexural Strength Machine (IS. 516 : 1959, Fig. 3, Page No. 19) |
| 2 | Concrete Permiability Tester(Permiability Apparatus as per Clause 3 of IS : 3085 (1965) Fig. 2 and 3) |
| 3 | Field Test CBR with Providing Ring(CBR Test Apparatus IS : 2720 (Part 31) 1998, Clause 4, Fig. 1, Page No. 3) |
| 4 | Hardness Tester for Bitumen Mastic Asphalt with Accessories (As per Clause E-2, Fig. 4 (Page No. 9) of IS 1195:2002) |
| 5 | Thin Film Oven (IS : 1212-1978, Clause 3, Fig. Page No. 98) |
| 6 | App. For Determination of Residue on Evaporation Apparatus : 600 Micron IS Sieve : A Circular sieve approximately 100 mm. in diameter and 40 mm. height. Metal or Glass Dish : A small metal or glass dish above 110 mm. in diameter (Such as a clock glass) Oven : A well ventilated oven thermostatitically controlled to 100 to 110 degree C. Balances : One of capacity 250 g. and accuracy of 0.01 g and one of capacity 10 Kg. and accuracy of 1 g. Container : A clean, weighed, 1.5 litre container. Solution : Distilled Water. Solvents : Xylene and acetone. |
| 7 | Particle Charge Tester Apparatus : Current Source : A 12 V. battery. Rheostat : of 2000 ohm capacity. Ammeter : of 0.1 Ampere capacity. Stainless Steel Plates : Two, 25 mm. x 75 mm. size.Glass Container : of 500 ml. capacity. |
| 8 | PH Meter Table Top (As per IS 2711 (1979) |
| 9 | Water Testing Kit SulphateAs per IS 3025 (Part 24) Apparatus – Steam Bath.Drying Oven : Equipped with thermostatic control. Muffle Furnace : with heat indicator.Disiccator. Analytical balance : capable of weighing to 0.1 mg.Filter Paper : Acid Washed, ashless hard finish filter paper sufficiently retentive for fine precipitates (Preferably Whatman No. 42) Crucible : Porous bottom silica or porcelain crucible with a maximum pore size of 5 microns |
| 10 | Water Testing Kit Chloride (As per IS 3025 (Part 32) Apparatus : Erlenmeyer Flask – 250 ml. |
| 11 | Retro reflectometer (As per IS) |
| 12 | Benkleman Beam with dial gauge(As per IRC : 81-1997 Cl. 3.2 Benkelman Beam consists of a slender beam 3.66 m. long pivoted at a distance of 2.44 m. from Tip (See Fig. 1 of IRC : 81-1997 Page No. 4) |
| 13 | Cold Water Bath App. (IS : 1203 – 1978 Clause 3.3) |
| 14 | Apparatus for Distillation of Paving Bitumen (As per IP 27, IS 1213 ASTM D402 method A complete with one distillation flask of 500 ml. capacity and one 100 ml. crow receiver (without thermometer) Electrically heated model with Energy regulator). |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed