Housing Urban and Rular Development Government Departments Closing in 0 days TDR #30490140

Construction Of World Trade Centre At Core Capital Area At Site1 Hec Area Ranchi Jharkhand Construction Of World Trade Centre At Core Capital Area At Site1 Hec Area Ranchi Jharkhand

Issued by Government Departments · , Jharkhand
Tender Value
44.23 Crore
Estimated cost
Bid Submission
19 Jan 2022
0 days left
EMD
44.24 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of World Trade Centre At Core Capital Area At Site1 Hec Area Ranchi Jharkhand Construction Of World Trade Centre At Core Capital Area At Site1 Hec Area Ranchi Jharkhand

BOQ

Name of Work:Construction of World Trade Centre at Core Capital Area at Site-1, HEC area, Ranchi, Jharkhand.
Sl. No. Item Description
1Earth Work inexcavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, levelling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
2Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B)
3Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
4Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including\" cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
5Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
6Providing P.C.C. M-75with nominal mix of (1:4:8) in foundation with approved quality of stone MTR.al grade - III (50 mm to 25mm size) clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, taxes and royalty all complete all complete as per building specification and direction of Engineer-in-charge.
7Providing and laying in position machine bached and machine mixed design mixM-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excuding the cost cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works upto plinth level
8Providing and laying in position machine bached and machine mixed design mixM-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excuding the cost cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level
9Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for Each four floors or part thereof.
10Add for using extra cement in the items of design mix over and above the specified cement content therein.
11Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-35 is @ 420 kg/ cum)
12Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns,etc. for mass concrete
13Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
14Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
15Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
16Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
17Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
18Extra for shuttering in circular work (20% of respective centring and shuttering items )
19Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 MTR.re or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
20Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
21Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMTFe 500 (only vailid for TATA (TISCON), SAIL,JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
22Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMTFe 500 (only vailid for TATA (TISCON), SAIL,JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
23Providing Tor steel reinforcement of 12mm. to 32mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMTFe 500 (only vailid for TATA (TISCON), SAIL,JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
24Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:6) in foundation and plinthwith approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
25Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
26Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG)in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
27Extra for brick work for each consecutive floor above first floor including watering & scaffolding all complete as per direction of E/I
28Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
29Providing random rubble stone masonry in cm ( 1;6) in super structure with hammer dressed stone of less than 0.03 m3 in volume and clean coarse sand of FM 2 to 2.5 including cost of screening , raking out joints to 20mm depth , curing taxes and royalty all complete as pr building specifications and direction of E/I.
30Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
31Supplying, fitting and fixing good quality, well dressed and well seasoned Sal wood work in choukhat in doors, windows, skylights, fanlights and C/W celestial window openings, including wedge over all clamps complete includingapplicationof two coatsof wood preservativeof approved quality on the surface butting walls and lintels all completeas per building specificationand direction of E/I
32Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
33Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
34Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :50x12 mm
35Providing, fittingand fixingoxidised iron fitting of approved quality and make to door and window all complete as per building specification and direction of E/I necessary screws etc. complete.300 mm sliding door bolt
36Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
37Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineerin-charge.
38Providing & fixing Floor patch lock of approved make & design
39Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
40Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
41Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness
42Providing and fixing 12 mm thick frameless toughened glassGLAZING CUM DOOR shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings and U channel under floor for fixed portion with silicon jointing fittingall complete as per direction of Engineer-in-charge
43Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
44Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634- 1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge
45Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame
4630 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.
47Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
48Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
49Supply, fabrication and Installation and fixing of SPACE FRAME structure The modular MS Frame shall be consisting of tube 72 mm and 72mm /3 mm CHS and 85 mm /3mm CHS and painted with Duco spray coat over priming coat
50Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.
51Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.3 -Glazed Vitrified tiles Matt/Antiskid finish of size. 11.41A.3.1 Size of Tile 600 x 600 mm
52Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.3 -Glazed Vitrified tiles Matt/Antiskid finish of size.11.41A.3.4Size of Tile 800 x 1200 mm
53Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 SQM
54Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by theEngineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent.
55Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work
56Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
57Providing 50mm thick cement concrete flooring (1:2:4 with 20mm to 6mm size grade stone chips finish with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes & royality with all complete as building specification and direction of E/I
58Extra for vaccum dewatering the concrete floors using TREMIX or equivalent over P.C.C layer i/c finishing the top surface to required level/ slope and grade with rough / polish finish using power trowels (both fan & disc) of standard make including curing, cutting of groove of grid size 4m x 4mwith, mixing of nonMTR.allic hardening compound (3.0 Kg/SQM of Fosroc or approved make) ,cutting of VDF floor with Diamond Saw System (disposal of debris to be included in the quoted rate)as per specification etc. complete as per specification and drawing. (Maximum thickness of RCC flooring shall be of 150 mm) At all heights / depths and levels. Extra for filling grooves with polysulphide 6mm wide, 20mm deep.
59Extra for filling grooves with polysulphide 6mm wide, 20mm deep.
60Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
61Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
628mm thick (mirror polished and machine cut edge Granite stone of any colour and shade
63Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
64Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
65( Treatment below Raft) Supplying and installing Dr.Fixit Prebond - 1.2mm thick self-adhesive HDPE membranehaving the following technical properties-Puncture resistance >800N (as per ASTM E 154) ,Tensile strength of 21 Mpa as per ASTM D412,Elonagtion of 400% as per ASTM D 412, Resistance to hydrostatic head > 60Mas per ASTM D 5385,Peel adhesion to concrete 880N/m as per ASTM D 903.The system should be fully bonded to the RCC and consists of highly resilient HDPE layer, a pressure sensitive adhesive layer which is covered by a weather proof protective layer. The membrane shall have minimum of 75mm side and end laps which shall be sealed with double sided adhesive tape.The size of the membrane should not be less than 2.4Mtr. x 20 Mtr. to minimize the joints and the entire waterproofing treatment should be guaranteed by the principal manufacturer as a system, for ten years, materials, labours, tools, tackles, etc., complete.
66Contractor shall give 10 years gaurantee for waterproofing and the work should be executed by the authorized/ inhouse manufacturers applicatorswhohave executedmore than 10,000 sq.mtr area of same system in single project.Providing and fixing Swell able water bar 20 X 10mm at construction joint and junction of raft and retaining wall.
67Supply & installation of 180 gsm geotextile as a protection layer. Protecting the membrane with50mm thick Screed (P.C.C)(In the scope of main contractor or client)
68(External Side):Providing and laying of 1.5 mm thick Dr.Fixit Samshield XL- SBS based self-adhesive waterproofing membrane topped with hdpe cross laminated film with the following techncial properties-Softening point >105 as per ASTM D36,Tensile Strength (L/T), (N/mm2)- L 34-50,T 40-56as per ASTM D 882,Elongation (L/T), (%) -L 200-260 ,T 160-200 as per ASTM D882, Puncture Resistance> 200as per ASTM E 154 including cleaning the surface,priming the surface with cold applied bituminous primer@4-6 sqmtr/litre, properly sealing the joints & maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the slab etc. complete.
69Providing & Fixing of protection board- 6mm thick Expanded polystyrene boardspot bonded on retaining wall before backfilling.
70Providing aluminum flashing, wherever required for termination ofself adhesive membranes at all locations. Item shall include rates for membrane termination on the Vertical retaining wall at height as specified in drawings for termination of the membrane and finally sealing the strip usingPolysulphide sealant.
71Contractor shall give 10 years gaurantee for waterproofing and the work should be executed by the authorized/in house manufacturers applicators who have exected more than 10000 sq/mtr area of same system in single project.WATERPRROFING FOR OLD AND NEW ROOF SLAB : Providing and laying waterproofing treatment on Roof Slab by applying two component factory designed ,ready to use ,acrylic modified flexible material applied with brush ,roller, or spray for waterproofing coating caoting as per manufacturer specification and following steps surface praparation : Providing nd cleaning of concree surfase to remove the dust oil,grease including removal of existing loose paint/ coatingand cement laitance by cleanning with compressed air and water jet including all materials ,laobour tools complete .Pondig test to be done after plugging all outlets and to checked from soffit to identify seepage ,leakage . on identification ofseepage ,cement grouting to be done with non shrink expanding admixture of SIKA INDIA PVT Ltd /MYK Schomburg /Dr.Fixit/fosroc or equivalent . providing and Repairing of all corners and joints such as those between the parapet wall and the roof slab etc shall be campererd with 150 mmx150 mm fillet of mortor (Cement :sand-1:4) Admixed with acrylic polymer of Sika /Fosroc/MYK/Dr.Fixit damaged concreting base slab,dead cracks if any with an acrylic polymer modified repair mortor including coat of Bonding agent of the same with cement slurry including all material,labour,tools comlplete.b) Apply fisrt coat two component acrylic modified ,ready use ,flexible cementituous material on surface saturated dry roof and inside wall of paraphet wall upto 600 mm by brush or roller .After 1st coat of application ,45 GSM of fibre cloth to lay when fibre glass cloth when the first layer is still in green .1st coat to be applied @1.5kg/sqmt/coat. for the purpose of measurement entiretreated surface will be maesured. c)2nd coat -To apply the 2nd coat of two component acrylic modified ready to use ,flexible cementituous material at right angle to the first coat over the glass fibre laid surface 2nd coatshould be applied at @.7 kg /sqmtr /coat. for the purpose of measurement entiretreated surface will be maesured.After three days of drying 2nd coat the rain water outlets to be plugged and ponding test to be done for 48 hrs to identify the seepage ,leakage from the sofit and if found necessary rectification to be done as per satisfaction of E/C. The waterproofing coating to protected from damage before screed over it.Waterproofing brand- Sika Topseal 109hi/Fosroc Brushbond RFX/Dr.Fixit Pidifin 2K/MYK Aquafin TG Product Prformance--Chemical Base part A Acrylic Polymer ,Part B ,Specially graded cementitious powder Density -1.6 Kg/l(mixed density) at 27 C .Tensile strength -2N/MM2 After 28 days (with fibre cloth )According to ASTM D2370),Pull out bond strength -2N/mm2(concrete failure )According to ISO 4624 Slant shear bond strength -4N/MM2(According to FIP 5.15)Elongation at break -35% without fibre cloth and 20% with fibre cloth (According to ASTM D2370) d) Protection of treated surface with PCC -The treated surface should be covered with 25mm/50MM PCC of M-20 Grade (1:1.5:3) with proper slope (1:20) towards the rain outlets in alternate pannel of 2mtrx2mtr keeping gap of between the pannel joint .Integral waterproofing admixture confirming to IS 2645 @ 100ML Per Bag of cement to be added inscreed concrete (Paid seperately for this item) all corners to be champered with 150mmx150mm fillet .The Rain water oulets shall be just levelled with the screed to ensure smooth discharge of water -The pherperal gaps between PVC pipes oulet and concrete surface to be packed properly with moisture insensitive epoxy putty of Sika India Pvt Ltd/MYK Schomburg/Dr.Fixit/Fosroc.
72For purpose of measurement the entire traeted surfaceto be measured. e) Goove of PCC -Surfcae should be filledwith polysulphide sealent (paid Seperately) Brand -Sika India Pvt Ltd/MYK Schomburg /Dr.Fixit/Fosroc.Warranty 10 years Covering treated surface with PCC: Providing 50 MM thick cement concrete M20(1;1.5;3) Maintaining slope in alternate pannel 2mtx2mt pannels with approved quality stone chips 20mmto 6mm size graded and sand of F.M.2.5 to 3 including screening,shuttering and mixing cement concrete in mixer with admixture of integral waterproofing and placing position,striking,curing taxes ,loyality all complete as per specification and direction of E/I,Pannels that has been left should be casted next day ,There should be 6mm gap between the Pannels. Brand-Sika plastocrete plus,/MYK Schomburg WP 10 /Dr.Fixit-Pidiproof lw+/Fosroc -Conplast X421IC or equivalent
73Providing and mixing integral waterproofing compound in concrete or plaster as per manufacturer specification and as per direction of Eng in chargeBrand-Sika plastocrete plus,/MYK Schomburg WP 10 /Dr.Fixit-Pidiproof lw+/Fosroc -Conplast X421IC or equivalent
74Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonrywith polymer mixed slurry
75Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19 mm thick (1:2:4) with 12 mm to 6mm size graded stone chips and top layer 6 mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l
76Provinding and fixing UPVC Foot rest all complete
77Providing and laying 25mm. thick kotah stone slab flooring of approved size, texture and colour over 19 mm thick base of lime morter (1:l:1) ( Lime putty : surkhi: coarse sand ) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size.
78Providing and laying 25mm. thick kotah stone riser of steps, skirting and pillers of approved size, texture and colour over 12 mm thick cementmorter (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size.
79Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
80Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
81Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
82Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
83Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
84Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM
85Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats
86Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats
87Extra for plaster work over exterior surface for each consective floor above first floor including cost of scaffolding etc. all complete.
88Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
89Providing two coats of oil bond Distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone of fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification direction of E/I
90Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.
91Making of GFRC Screen (35mm thick inside-50 mm thick border) as per your design. As per the design of architects. Including fixing to wall in cement:sand mortar all in perfect line and length complete
92Providing and fixing terracotta (Breeze®) cladding of dimension 304*594*16 mm with modules of 300*600 with Q3** resistance to impacts (classification as per P08- 302) with wind resistance to positive/ negative pressure 7000 / 5500 Pa, weight of27.13 kg per m2 which conform to standard NF EN 539-2, water absorption to be between 3% - 5% conforming to EN ISO 10545-3 § 5.1.1, bending strength not to exceed 1503 Newton conforming to EN ISO 10545-4. Installation of Breeze® terracotta panels to be done by securing to the vertical T-shaped aluminium profile using the fixing clips fastened with 2 self-tapping stainless steel screws. Vertical aluminium T-shaped profiles are to be pre-punched hole with vertical spacing of 25mm. The terracotta tile is to be well-supported on four points by the clips and on its two smaller sides by the rubber gasket so as to have a very good wind load resistance of more than 7000 PA positive wind load pressure and a negative wind load pressure of 5500 PA and flexural strength of 150 da N. The total thickness Breeze® cladding system are not to be more than 110 mm. The quantity of products per sq.m are to be 5.56 tiles, with quantity of profiles per main course sq.m to be 1.67 lm/m2, with quantity of clips to be 11.11 nos. per sq.m.
93Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
94For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
95Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
96Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels including: Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporatingprinciples of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal placesNote:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.(1). Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr. (2) Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml. (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm. (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to beconducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
97Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glasspanels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided bytechnical sanctioning authority as per the site requirement.
98Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
99Passenger Lifts 13 PassengerG+5, Power operated, ACVVVF, 1.5 speed M/Sec. of approved design and make
100Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/SQM (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm Each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, Including fixing periMTR.er channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the periMTR.er of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMTR.er channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of periMTR.er channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
101Providing and fixing GI Clip in MTR.al Ceiling System of 600x600 mm module which includes providing and fixing \"C\" wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the periMTR.er of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/SQM (both side inclusive), fixing with clip in tiles into spring \"T\" with: GI MTR.al Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ SQM (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
102Providing & Fixinglaminated wooden false ceiling , made in50x50mmHard wood frame (Mirandi) center to center 600mm both ways, hang to ceiling with help of hanger support \"L\" type G.I angle (25x25mm) andanchor bolt etc. over fixed 11mm thick MDF board with 10x8mm deep groovefinish with lacqure polish, 1.0 mm thick approved shade laminate to fixed on MDF board, defects free bubbles freewith help of adhesive.as per drawing and to the entire satisfactionof Engineer in charge. ( MDF Boad & Laminate Make Green ply/Century /Merino orEquivalent ,Adhesive make Pidilite or equivalent) (MDF base rate Rs. 285/-sqm & Laminate base rate Rs.403/- sqm)
103Providing and making cove in gypsum board.false ceiling with all accessories.as per drawing and instructions of Engineer in charge .
104Providing and Fixing false ceiling Armstrong Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architect/ approving engineer, made of a high density fibre board with minimum 725 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Architect/ Engineer-in-Charge. Install wooden battens (provided by others) of section 50x50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks provided by Armstrong over the lowest and second wooden batten at an on-centre distance of 600mm. Install the Skirting (provided by others) of width 50mm or more as required by the Architect/ Engineer-in-Charge and insert the tongue end of the panel in the skirting. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour (provided by others). Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure. (Make Armstrong /EQ )
105Providing and Fixing Armstrong SoundScapes – Blades which are 40 mm thick, pre-formed fiberglass blades with sizes of 200X1200mm with laminated scrim finish on all sides and edges, Acoustical performance of 0.65 NRC in standard White color with Light reflectance 87%, or in the color specified by the Architect (Light Ivory, Pale Green, Pastel blue, Traffic Grey, Pale Brown)and Fire Performance Class B – s1, d0 as per En 13501-1.INSTALLATION WITH HANGER WIRE:The SoundScapes Blades shall be factory fitted with spiral hooks on both sides. The blades to be suspended individually using the Armstrong Hanger Wire kit comprising of hanger wire, cable adjuster and cable finishing hook. Blades must be installed with minimum 100 mm on-centre spacing.Hanger Wire Attachment to Structure: Attach the gripper structure anchor to the structure with a fastener that will carry the full weight of the blades. Insert the end of the cable into the gripper anchor cap. Screw the gripper anchor cap completely into the gripper structure anchor.Insert Suspension Cables:Insert the hanger wire into the top of the cable adjuster. Gently pull the cable through the cable adjuster until the desired level of installation is achieved. Tighten the Cable finishing hook on the bottom of the Cable adjuster.Suspend the Blade: Locate the two factory fitted spiral anchors on the blades. Suspend the Blades by inserting the cable finishing hook into the spiral anchors on both sides of the blades. Installation to be carried out by Armstrong Trained Installation team & Installation should becarried out as per Armstrong recommended procedure.
106CARRAIGE OF MATERIALSCEMENTS (UPTO 5KM LEAD) RANCHI
107SAND(UPTO 36 KM LEAD)SWARNREKA
108CHIPS(UPTO 11 KM LEAD) JONHA
109METAL(UPTO 11 KM LEAD) JONHA
110STEEL(UPTO 5KM LEAD) RANCHI
111BRICKS (UPTO 10KM LEAD) RANCHI
112Prividing and fixing Sculpture in all complete direction engineers - in - charge
113Building signage in all complete direction engineers - in - charge
114Automatic boom barrier for gate
115Motorized Automatic sliding gate (9m WIDTH): Made of Stainless steel SS304 grade, as per standard design. Complete set with Sliding motor & controllers. Both automatic & manual operation. With stainless steel rails
116supply installation , testing and commissioning of grid interactive roof top solar photo voltaic power generation system including space frem. power plant on capacity -50KVA. all complete direction engineers - in - charge
117Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) Using Concrete Mixer
118Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.)With Vibratory Roller
119Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
120Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )
121Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.
122Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
123Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge
124Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
125Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)Screened through sieve of IS designation 20 mm
126Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)Screened through sieve of IS designation 16 mm
127Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)Screened through sieve of IS designation 4.75 mm
128Supplying and stacking of well decayed cow dung manure at site including royalty and carriage up to 1.0 km (cow dung manure measured in stacks will reduced by 8% for Payment)
129Fine dressing of the ground
130Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge
131Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).
132Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts
133Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 1.2 m diameter and 1.2 m deep
134Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 90 cm diameter and 90 cm deep
135Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 60 cm diameter and 60 cm deep
136Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 45 cm diameter and 45 cm deep
137Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Azadirachta Indica
138Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Alstonia scholaris
139Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Ficus benjamina
140Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Bauhinia purpurea
141Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Callistemon lanceolatus
142Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Cassia javanica
143Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Delonix regia
144Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Cassia fistula
145Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Plumeria alba
146Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Plumeria rubra
147Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Mangifera Indica
148Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Phyllanthus emblica
149Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)foxtail palm
150Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Buddha belly bamboo
151Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Clerodendrum inerme
152Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Ficus panda
153Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Ficus benjamina Starlight
154Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Gardenia jasminoides
155Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Golden duranta
156Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Hamelia patens
157Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Hibiscus rosa-sinensis
158Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Raphis excelsa
159Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Tecoma gaudichaudi
160Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) TMC dwarf
161Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Alternanthera red
162Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Chlorophytum comosum
163Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Jatropha
164Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Sprenger\"s asparagus
165Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Syngonium podophyllum
166Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Tradescantia pallida
167Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Cynodon dactylon
168Fabric Panel: Supply of Fabric Panel of selected colours (ref colour chart) Kerf edge Fabric wrapped pinewood fiber panels of size 600x1200x25mm having density 400Kgs/m3, weight 8kg/m2 installed by using GI strut system. Framework includes Floor/ Head (FC50) GI channels having thickness 0.5mm, length 3600mm, equal flanges of 32mm and web of 50mm fixed to floor and ceiling touching the main wall, with suitable fasteners at 300mm centers staggered. Then Stud channel (SC48) having thickness 0.45mm, length 3600mm, unequal flanges of 34/36mm and web of 48mm should be placed into The GI strut works includes Cross channel (CC10) having thickness 0.45mm, length 3600mm, knurled web 50, depth 10mm and equal flanges of 13mm is fastened to Wall positioned horizontally in a regular manner at 600mm centers. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels (CC10) at 600mm centers. Make: Echo-Sound/Anutone/ Rockfone
169Wooden Wall Peneling: Providing and Fixing Armstrong Channelled Woodworks perforated panels of width 128mm, thickness of 15mm and length 2440 mm or as required by the Architect/ approving engineer, made of a high density fibre board with minimum 830 Kg/M3 density substrate with a laminated facing / wood veneer as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of \ 4mm width and 28mm visible panel each. The panels shall provide a fire reaction of Class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.55. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Architect/ Engineer-in-Charge. Install wooden battens (provided by others) of section 50mmx50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks (GTPT001) provided by Armstrong over the lowest and second wooden batten at an on-centre distance of 600mm. Install the first set of wooden panels by inserting the clips for border channelled woodworks (GTPT002) and insert the groove of the panel into the projectingflange of the aluminium clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channelled woodworks (GTPT003) into the next keel till the actual height is achieved. Use clips for border channelled woodworks (GTPT002) to finish off the installation. Finish off the edges using wooden moulding of matching colour (provided by others). Make:Echo-Sound/Armstrong / Rockfone
170Stage Wooden Flooring :-Make: Hornitex
171L Profile(Make: Echo-Sound)
172Door Profile: (Make: Echo-Sound)
173Grid Tiles:Providing and fixing tiled false ceiling at all height of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights and all levels as per specifications, drawings and as directed by Engineer-in-charge. 15 mm thick soft core mineral wool 595x595mm thick white colour tile having NRC greater than0.65 of St. Gobain . Make- Echo-Sound/ Anutone/ Rockfone
174Carpet: Make-echo sound/ vito/unitex
175Flush Door-Providing & Fixing of Laminated flush door of 35mm thick complete with door frame with final finish. Note: Accesories not Included Like Door Closer, Door Lock.
176Stage Procenium: Fabricating and fixing on the Stage Proscenium to be fabricated out oftubular framework of MS Tubes section 50 X25 mmsquareat 600mm c/c bothways; fixing including finishing with 2 or more coats of plastic emulsion paint.
177Variable Refrigerant Flow Air-conditioning System Supply, Installation, testingand commissioning of Variable Refrigerant Flow modular type air-conditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications andhaving following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.it should Be BMS Compatible Supply , Installation, testing and commissioningof Outdoor Unit with blue fin coating @ 112 F Supply , Installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll Multi compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address setting and capacity as mentioned below. 12 HP OUTDOOR UNIT (COOLING AND HEATING BOTH )
178Variable Refrigerant Flow Air-conditioning System Supply, Installation, testingand commissioning of Variable Refrigerant Flow modular type air-conditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications andhaving following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.it should Be BMS Compatible Supply , Installation, testing and commissioningof Outdoor Unit with blue fin coating @ 112 F Supply , Installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll Multi compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address setting and capacity as mentioned below. 16 HP OUTDOOR UNIT(COOLING AND HEATING BOTH )
179Variable Refrigerant Flow Air-conditioning System Supply, Installation, testingand commissioning of Variable Refrigerant Flow modular type air-conditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications andhaving following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.it should Be BMS Compatible Supply , Installation, testing and commissioningof Outdoor Unit with blue fin coating @ 112 F Supply , Installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll Multi compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address setting and capacity as mentioned below.20 HP OUTDOOR UNIT(COOLING AND HEATING BOTH )
180Variable Refrigerant Flow Air-conditioning System Supply, Installation, testingand commissioning of Variable Refrigerant Flow modular type air-conditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications andhaving following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.it should Be BMS Compatible Supply , Installation, testing and commissioningof Outdoor Unit with blue fin coating @ 112 F Supply , Installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll Multi compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address setting and capacity as mentioned below.22 HP OUTDOOR UNIT(COOLING AND HEATING BOTH )
181Variable Refrigerant Flow Air-conditioning System Supply, Installation, testingand commissioning of Variable Refrigerant Flow modular type air-conditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications andhaving following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.it should Be BMS Compatible Supply , Installation, testing and commissioningof Outdoor Unit with blue fin coating @ 112 F Supply , Installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll Multi compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address setting and capacity as mentioned below. 24 HP OUTDOOR UNIT(COOLING AND HEATING BOTH )
182Variable Refrigerant Flow Air-conditioning System Supply, Installation, testingand commissioning of Variable Refrigerant Flow modular type air-conditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications andhaving following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.it should Be BMS Compatible Supply , Installation, testing and commissioningof Outdoor Unit with blue fin coating @ 112 F Supply , Installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll Multi compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address setting and capacity as mentioned below. 26 HP OUTDOOR UNIT(COOLING AND HEATING BOTH )
183Variable Refrigerant Flow Air-conditioning System Supply, Installation, testingand commissioning of Variable Refrigerant Flow modular type air-conditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications andhaving following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.it should Be BMS Compatible Supply , Installation, testing and commissioningof Outdoor Unit with blue fin coating @ 112 F Supply , Installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll Multi compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address setting and capacity as mentioned below. 32 HP OUTDOOR UNIT(COOLING AND HEATING BOTH )
184Variable Refrigerant Flow Air-conditioning System Supply, Installation, testingand commissioning of Variable Refrigerant Flow modular type air-conditioning system Invertor Controlled with stepless modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications andhaving following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.it should Be BMS Compatible Supply , Installation, testing and commissioningof Outdoor Unit with blue fin coating @ 112 F Supply , Installation, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll Multi compressors with both inverter speed type compressors special heat exchanger, low noise condenser fan ,auto check function for connection error, auto address setting and capacity as mentioned below.42 HP OUTDOOR UNIT(COOLING AND HEATING BOTH )
185Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings1x1.59 TR/635 CFM Duct Type Unit
186Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings 1x2.5 TR/883 CFM Duct Type Unit
187Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings 1x3.18 TR/1130 CFM Duct Type Unit
188Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings1x4 TR/1377 CFM Duct Type Unit
189Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings1x4.5 TR /1624 CFM Duct Type Unit
190Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings1x5.45 TR/2047 CFM Duct Type Unit
191Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings1x6.36 TR/2400 CFM Duct Type Unit
192Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings 1x8 TR/2824 CFM Duct Type Unit
193Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings1x1.5 TR Hi wall Unit
194Indoor Units with + 5% Tolerance Supply Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. multispeed motor, ,coil section with DX coil, outer cabinet, drain pan, drain pumps with all units, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings 1x1.5 TR FOUR WAY CASSETTE UNITS
195Supply Installation, testing and commissioning ofY-joints.
196Supply Installation, testing and commissioning ofself diagnostic type remote controllers. Corded Type
197Supply Installation, testing and commissioning of Main Intelligent central controller system Touch Screen suitable for above indoor units to operate, monitor, on/off, temperature setting etc.
198Supply Installation, testing and commissioningof factoryfabricated Double Skinned DX Type Air- handling unit Ceiling suspended type, fabricated out of extruded aluminium section with 0.63mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.63 mm plain Galvanised steel sheet inside with DWDI blower Forward Curved , blower section and blower motor TEFCtype suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row DX Type cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particlesize with an efficiency of 90% , polished stainless steel drain pan madeoutof 22 G sheet duly insulated complete with motor and belt drivepackage etc. without face and bypass dampers. The AHU panels shall be insulated with 40 mm thick & 40 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only The complete AHU shall confirm to standard specification.Theface velocity across cooling coil shall be limited to 152 MPM maxm. Pre-filter section with Pre filter(10 Micron & 90 % Efficiency) in All following AHUSFan Outlet Velocity Not to Exceed 8.5 m/sAccessories for AHU kit Expansion Device & control boxDX cooling coil, Expansion device, communication kit, canvass connection and remote control etc The complete AHU shall confirm to above & standard specification. CS AHU 1x2500 CFM/50 MM Static /6RD
199Supply Installation, testing and commissioningof factoryfabricated Double Skinned DX Type Air- handling unit Ceiling suspended type, fabricated out of extruded aluminium section with 0.63mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.63 mm plain Galvanised steel sheet inside with DWDI blower Forward Curved , blower section and blower motor TEFCtype suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row DX Type cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particlesize with an efficiency of 90% , polished stainless steel drain pan madeoutof 22 G sheet duly insulated complete with motor and belt drivepackage etc. without face and bypass dampers. The AHU panels shall be insulated with 40 mm thick & 40 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only The complete AHU shall confirm to standard specification.Theface velocity across cooling coil shall be limited to 152 MPM maxm. Pre-filter section with Pre filter(10 Micron & 90 % Efficiency) in All following AHUSFan Outlet Velocity Not to Exceed 8.5 m/sAccessories for AHU kit Expansion Device & control boxDX cooling coil, Expansion device, communication kit, canvass connection and remote control etc The complete AHU shall confirm to above & standard specification. CS AHU 1x 3000 CFM/50 Static /6RD
200Supply Installation, testing and commissioningof factoryfabricated Double Skinned DX Type Air- handling unit Ceiling suspended type, fabricated out of extruded aluminium section with 0.63mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.63 mm plain Galvanised steel sheet inside with DWDI blower Forward Curved , blower section and blower motor TEFCtype suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row DX Type cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particlesize with an efficiency of 90% , polished stainless steel drain pan madeoutof 22 G sheet duly insulated complete with motor and belt drivepackage etc. without face and bypass dampers. The AHU panels shall be insulated with 40 mm thick & 40 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only The complete AHU shall confirm to standard specification.Theface velocity across cooling coil shall be limited to 152 MPM maxm. Pre-filter section with Pre filter(10 Micron & 90 % Efficiency) in All following AHUSFan Outlet Velocity Not to Exceed 8.5 m/sAccessories for AHU kit Expansion Device & control boxDX cooling coil, Expansion device, communication kit, canvass connection and remote control etc The complete AHU shall confirm to above & standard specification.CS AHU 1x5000 CFM/13 TR/50 MM Static
201Supply Installation, testing and commissioningof factoryfabricated Double Skinned DX Type Air- handling unit Ceiling suspended type, fabricated out of extruded aluminium section with 0.63mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.63 mm plain Galvanised steel sheet inside with DWDI blower Backward Curved , blower section and blower motor TEFCtype suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row DX Type cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particlesize with an efficiency of 90% , polished stainless steel drain pan madeoutof 22 G sheet duly insulated complete with motor and belt drivepackage etc. without face and bypass dampers. The AHU panels shall be insulated with 40 mm thick & 40 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only The complete AHU shall confirm to standard specification. Theface velocity across cooling coil shall be limited to 152 MPM maxm. Pre-filter section with Pre filter(10 Micron & 90 % Efficiency) in All following AHUS Fan Oulet Velocity Not to Exceed 8.5 m/s Accessories for AHU kit DX cooling coil, Expansion device, communication kit, canvass connection and remote control etcThe complete AHU shall confirm to above & standard specification. FM AHU 1x8500 CFM/65 MM Static /6RD
202Supply , installation, testing & Commissioning of DX type split/Ductable units with air cooled condenser mounted in outdoor unit complete with scroll/rotary compressor ,condensor ,wiring & accessories . Indoor units shall bewith evaporator ,fan, filter ,drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge , cordless remote controls. The unit shall be suitable for working 50 cycle /second ,1 phase AC supply .The unit shall be designed to take care of veritcal head 4mt & horizontal length of 15mt & necessary oil seprator shall be included ,Necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy paintedMS stand for ODU units as per approved make shade by Architect) with necessary vibration isolation arrangement as per site condition etc.( without condensate drain pipe ,electrical pipe ,electrical power & control cabling between indoor & outdoor unit which shall be paid seprately ). The Color of the outdoor units to be finalized by the Architect as per building Architectural elevation. All Unit shall be Minimum 3 Star Rating Based The Outdoor unit Compressor must be provided with 5 Year Warranty Period. Civil Work such as wall hole making , wall chiseling, refilling of chiseling part with mortar etc as per site condition.Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU with flar nuts Removable Covers for all indoor & Outdoor units shall be supplied & put on the units after installation & commissioning. Incoming power supply shall be provided near each indoor unitsSound level of Outdoor unit shall be 70 Db at 1 Mt Distance2.0TR Split Units
203Supply, Installation , testing , commissioningand handing over of thecoil mounted Ultra Violet Germicidal Irradiations ( UVGI) System for maintainingindoor Air Quality in AHU unit. The system should bedesigned to achive kill rate of not less than 90% per pass. The lamp shall have 9000 working hrs life, ballasts shall be electronic type, life rated grater than 15000 starts. An run hour meter shall be provided to indicate remaining life of the Lamp in the form timer of digital display. Minimum UV intensity should be 600 microwatts at all the corners of the cooling coil.Approved Make: Aeroshield / Crystal Clean
204Supply, Installation , testing , commissioningand handing over of thehighly efficient electronic class filtration system for improving the complete indoor air quality with a very low-pressure drop that integrates with the building air delivery system. The unit shall be designed to reduce at least 97% of the airborne particles down to 0.3 microns. MERV-15 rated with low pressure drop of less than 0.37\" wg at 2.5 m/s. Ozone generation shall be NIL with no components working on corona discharging principle for polarization. Should be capable of reducing PM 1.0, PM 2.5, PM 10, Bacteria, Virus, VOCs, Odor, etc and should meet all the other requirements mentioned in the tender specs. Approved Make: Aeroshield / Crystal Clean AHUS
205Supply, installation ,testing and commissioning of ceiling suspended Inline fans with Multi speed controller complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required of following capacities and shop drawing mentioned. Capacity: 1000 CFM Static Presure : 20 mm Of wg Kw :0.7 KW
206PROPELLER FANSSupply, installation, testing & commissioning of ceiling suspendedPropellar fans complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required offollowing capacities & as pershop drawing mentioned. 225mm Dia
207PROPELLER FANSSupply, installation, testing & commissioning of ceiling suspendedPropellar fans complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required offollowing capacities & as pershop drawing mentioned. 300mm Dia
208AXIAL FLOW FANS FOR FIRE MODE FAN (EXHAUST AIR ) Supply, installation, shifting, loading, unloading, testing & commissioning of Floor mounted, double flanged, long casing (motor should completly accomodated in Fan casing) axial flow fans with sound attenuator (Fire Rated) AMCA Certified, with adjustable pitch blade & angle, bird screen at fan outlet , MS/GI casing, cast aluminium alloy impellercomplete with TEFC Sq. Cage Inductionmotor suitable for 415 volts ± 10%,50Hz ± 3 %, 4/6/8 pole, three Phase, A.C supply class \"H\" /S insulation with support, Phase&Motor rated Value IP55 . Motor shall be Thermally Rated for 250 deg C for 2 Hours should be certified as per BSEN12101-3:2002 standard & direct driven for smoke extraction fans. With the Approx. Motor HP as given below (to be supported with Documentary evidenceat the time of Technical Bid.) The rate shall includesupply and fitting of vibration isolators ( spring & rubber pads) complete as per specifications and drawings including fitting of accessories like Fire retardant canvass connection painting,gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc Sound attenuator shall be as specified with following characteristics: a) Length not exceeding 1D (Fan Dia.) b) Pressure drop through through sound attenuator shall not exceed 8mm WCNote- 1. Outlet Velocity for normal mode fans not to exceed 14.0 MPS 1. Outlet Velocity for Fire mode fans not to exceed 18.0 MPS 2. Total efficiency of normal fans shall not less than 60%3. Fan motor shall meet IE2standard as per IS-12615 4.Static pressure and Motor Rating : TheIndicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager. Sound attenuator shall be as specified with following characteristics:5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm. 6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted. Air Qty. = 11000 CFMStatic Pressure=30 mm WgFan Speed= Not exceeding 1450 rpmMotor= Not exceeding 5.5 Kw.
209AXIAL FLOW FANS FOR FIRE MODE FAN (EXHAUST AIR ) Supply, installation, shifting, loading, unloading, testing & commissioning of Floor mounted, double flanged, long casing (motor should completly accomodated in Fan casing) axial flow fans with sound attenuator (Fire Rated) AMCA Certified, with adjustable pitch blade & angle, bird screen at fan outlet , MS/GI casing, cast aluminium alloy impellercomplete with TEFC Sq. Cage Inductionmotor suitable for 415 volts ± 10%,50Hz ± 3 %, 4/6/8 pole, three Phase, A.C supply class \"H\" /S insulation with support, Phase&Motor rated Value IP55 . Motor shall be Thermally Rated for 250 deg C for 2 Hours should be certified as per BSEN12101-3:2002 standard & direct driven for smoke extraction fans. With the Approx. Motor HP as given below (to be supported with Documentary evidenceat the time of Technical Bid.) The rate shall includesupply and fitting of vibration isolators ( spring & rubber pads) complete as per specifications and drawings including fitting of accessories like Fire retardant canvass connection painting,gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc Sound attenuator shall be as specified with following characteristics: a) Length not exceeding 1D (Fan Dia.) b) Pressure drop through through sound attenuator shall not exceed 8mm WCNote- 1. Outlet Velocity for normal mode fans not to exceed 14.0 MPS 1. Outlet Velocity for Fire mode fans not to exceed 18.0 MPS 2. Total efficiency of normal fans shall not less than 60%3. Fan motor shall meet IE2standard as per IS-12615 4.Static pressure and Motor Rating : TheIndicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager. Sound attenuator shall be as specified with following characteristics:5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm. 6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted. Air Qty. = 15000 CFMStatic Pressure=30 mm WgFan Speed= Not exceeding 1450 rpmMotor= Not exceeding 5.5 Kw.
210AXIAL FLOW FANS FOR FIRE MODE VENTILATION (FRESH AIR FAN ) Supply, installation, testing & commissioning offloor mounted double flanged, long casing (motor should completly accomodated in Fan casing) axial flow fansAMCA Certified, with adjustable pitch blade & angle ,bird screen at fan inlet, MS/GI casing, cast aluminium alloy impellercomplete with TEFC Sq. Cage Inductionmotor suitable for 415 volts ± 10%,50Hz ± 3 %, 4/6/8pole, three Phase, A.C supply class \"F\" insulation with support, Phase&Motor rated Value IP55 .with the Approx. Motor HP as given below ( to be supported with Documentary evidenceat the time of Technical Bid.)The rate shall includesupply and fitting of vibration isolators ( spring & rubber pads) complete as per specifications and drawings including fitting of accessories like Fire retardant canvass connectionpainting,gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc Note 1.Static pressure and Motor Rating : TheIndicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval.The procurement shall be processed only after duly approval of calculation and selection from the Project Manager. 2. Fan motor shall meet IE2standard as per IS-12615 3. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm. Air Qty. = 11000 CFMStatic Pressure=30 mm WgFan Speed= Not exceeding 1450 rpmMotor= Not exceeding 5.5 Kw.PART CPIPING WORK
211Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray. 41.27 mm dia(OD) (Hard drawn) with tube thickness 1.62 mm with19 mm thick insulation
212Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray.34.9 mm dia(OD)(Hard drawn) with tube thickness1.62 mm with 19 mm thick insulation
213Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray. 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
214Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray. 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
215Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray. 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
216Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray. 15.86mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with13 mm thick insulation
217Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray. 12.7mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with13 mm thick insulation
218Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray. 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with13 mm thick insulation
219Supply & fixing of interconnecting copper refrigerantpipe work (19mm / 13mm thick ) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units with starbond coating as per specifications. All piping inside the room shall be properly supported on MS Slottedtraysandallexternal pipingshall run in covered slotted tray. 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with13 mm thick insulation
220Supply, installation, testing and commissioning U-PVC pipe with fittings of 10 kg /cm3 with 6mm thick Nitrile rubber of Class \"1\" including all fittings and jointing with solvent cement and , including cutting chieseling / holes in walls,wherever required and making good the same, complete as directed by the Engineer in charge.40 mm dia O.D
221Supply, installation, testing and commissioning U-PVC pipe with fittings of 10 kg /cm3 with 6mm thick Nitrile rubber of Class \"1\" including all fittings and jointing with solvent cement and , including cutting chieseling / holes in walls,wherever required and making good the same, complete as directed by the Engineer in charge. 32 mm dia O.D
222Supply, installation, testing and commissioning U-PVC pipe with fittings of 10 kg /cm3 with 6mm thick Nitrile rubber of Class \"1\" including all fittings and jointing with solvent cement and , including cutting chieseling / holes in walls,wherever required and making good the same, complete as directed by the Engineer in charge. 25 mm dia O.D
223AIR DISTRIBUTION SYSTEM. GSS RECTANGULARDUCTING Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. splitter & vanes etc .shall be apart of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable.24 G (0.63 mm)
224AIR DISTRIBUTION SYSTEM. GSS RECTANGULARDUCTING Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. splitter & vanes etc .shall be apart of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable. 22 G (0.80 mm)
225AIR DISTRIBUTION SYSTEM. GSS RECTANGULARDUCTING Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. splitter & vanes etc .shall be apart of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable.20 G (1.0 mm)
226AIR DISTRIBUTION SYSTEM. GSS RECTANGULARDUCTING Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. splitter & vanes etc .shall be apart of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable. 18 G (1.25 mm)
227AIR DISTRIBUTION SYSTEM. GSS RECTANGULARDUCTING Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. splitter & vanes etc .shall be apart of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable.SITE FACBRICATED24 G (0.63 mm)
228AIR DISTRIBUTION SYSTEM. GSS RECTANGULARDUCTING Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. splitter & vanes etc .shall be apart of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable.SITE FACBRICATED 22 G (0.80 mm)
229AIR DISTRIBUTION SYSTEM. GSS RECTANGULARDUCTING Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. splitter & vanes etc .shall be apart of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable.SITE FACBRICATED20 G (1.0 mm)
230AIR DISTRIBUTION SYSTEM. GSS RECTANGULARDUCTING Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. splitter & vanes etc .shall be apart of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable.SITE FACBRICATED18 G (1.25 mm)
231MAIN DUCT DAMPER Supply, fabrication, installation and testing of 18G GI construction Main duct damper for supply & return air complete with nuts bolts, screws, linkage, flanges etc.ducts lever and quadrants for proper balancing of the air distribution system .
232Supply, fabrication, installation and testing of 50 micron powder coated, aluminum extruded linear fixed horizintal bar/grill with all side flangesas per approved shop drawings.
233Supply, installation, testing and commissioning of 50 micron powder coated\"Aluminium\" collar volume control dampers with key operated of black painted in supply air registers / terminals.
234Supply, installation, testing and commissioning of 50 micron powder coated Louver with \"Aluminium\" collar volume control dampers with key operated of black painted in supply air registers / terminals.
235DUCT INSULATION Supply & Installation of Thermal Insulation on Duct using Closed CellAnti Microbial and Anti Fungal Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 60 Kg/m3, Thermal Conductivity of 0.035 W/mk at 200 Celsius Mean Temp. and Mu=10000 with200+/-20 gsm using Rubber based Adhesive in a blend of solvents complete as per Specifications13 mm thick Class O Nitrile Rubber Insulation
236ACOUSTIC LINING Supply and Application of Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber with 15 mm Thick open cell foam with Density 140 - 180 Kg/m3 and Class 1 Fire Performance and with antimicrobial protection and should pass Fungi Resistance as per ASTM G 21 and Bacterial Resistance as per ASTM E 21 using manufacturer\"s recommended Rubber based Adhesive in a blend of solvents.
237ROOF INSULATION Supply & Installation of Thermal Insulation on Duct exposed to sunlight using Closed CellAnti Microbial and Anti Fungal Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 60 Kg/m3, Thermal Conductivity of 0.035 W/mk at 200 Celcius Mean Temp. and Mu=10000 and with Chemically treated Factory Laminated Woven Fibre Glass Cloth with200+/-20 gsm using manufacturer\"s recommended Rubber based Adhesive in a blend of solvents complete as per Specifications 25 mm thick Class O Nitrile Rubber Insulation with GC cloth
238Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the samein case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specification. Fire Damper
239Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the samein case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specification. Actuator
240COPPER CONTROL CABLING Supply and laying ,testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes : 3C X 1.5 sq.mm.
241COPPER CONTROL CABLING Supply and laying ,testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes : 3C X 2.5 sq.mm.
242Subhead:- I - Sanitary Fixtures Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \"p\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. 12.5 lit. low level P.V.C. cistern
243Providing, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of \"Hindustan \"Parry\" or any other approved I.S.S make 5 litre capacity C.I automatic flushing cistern of reliance or any other I.S.S approved make with all fittings with C.I or R.S brackets, standard size G.I flush pipe with fitting clamps, 15mm C.I body brass spindle stop cock of approved quality weight not less tahn 400grams, 15mm P.V.C/Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting of exposed parts with two coats of approved paint over a primer coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/IFlat back or standing corner (600mmX350mm)
244Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required. White vitreous china wash basin size 630 mm x 450 mm with a single 15mm CP brass pillar tap.
245Supplying, fitting and fixing white glazed fire clay sink of approved make with overflow arrangements supported on C.l. or R.S. painted brackets 40 mm dia C.P. brass waste with C.P. brass chain and rubber plug, 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one end and 15 mm C.I. body brass spindle bib cock of approved quality of weight not less than 450 grms. including cutting wall and making good the same etc. all complete as per specification and direction of E/lKitchen sink of size 600 mm x 450 mm x 250 mm
246Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materialswith snap fittings of approved quality and colour. weighing not less than 105 gms.
247Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
248Providing & fixing mirror of superior glass(of aproved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing: Rectangular Shape 453x357mm
249Providing and fixing toilet paper holder : C.P. brass
250Providing and fixing 15 mm dia Pvc connector 450mm long with connecting nuts [for connection to Mixers & taps from angle valve.] (Make-chunmun)
251Providing and fixing C.P. brass twin coat hooks fixed on toilet door with including CP brass screws, washers rawl plugh etc. complete in all respact. (Make: Jaquar Hook Continental ACN-CHR-1161N)
252Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge.
253Providing& fixingchinawareurinalpartitionof 90X320X 720mmwithfixed withexpandable anchor fastenerswith C.P.brass bolts and washers,embedded in wall with anchor and set in cement concrete completeincludingcuttingandmakinggoodthewallswhereverrequired(MAKE-HINDWARE,MODELNO. 61001, Starwhiteor EQUIVALENT.)
254Providing & fixing soild state no touch operating fully highgenic SS hand drier of best quality, to be operated with 230 volts, single phase, with fully hygienic condition, with all accessories including cutting and making goodthewalls,whereverrequired.(Make:-EuronicsModelNo-EH-01S/MAKW:CERACATNO. B2220101 or EQUIVALENT)
255Providing & fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia
256Providing and fixing of complete bathroom inside complete wallfloor concealed water supply pipes, soil & Waste pipe, cement work, chase cutting, hot & cold water provision water supply plumbing pipes and fitting, KITEC pipe with brass fitting (care wll pipe) pipe size: 1620mm | 2025mm dia pipe providing & fixing soil & waste pipe and fitting complete plan tee, elbow 45° band, \"Y\" tee, nahani drap, \"P\" trap, metal clamp with fastener complete (10 kg/cm² pressure supreme company) solvent welded joint as per manufacturers commendations, supreme 110mm dia uPVC pipe, PVC trap of self cleaning design including cost of cutting and making good floor 110x110 mm inlet & outlet PVC trap, 50mm, 63mm dia uPVC for waste & bottle trap waste pipe drain spout for sunken area (supreme 10 kg pressure pipe). for toilet and kitchen. (Make: Supreme) 32 mm .
257Providing and fixing of complete bathroom inside complete wallfloor concealed water supply pipes, soil & Waste pipe, cement work, chase cutting, hot & cold water provision water supply plumbing pipes and fitting, KITEC pipe with brass fitting (care wll pipe) pipe size: 1620mm | 2025mm dia pipe providing & fixing soil & waste pipe and fitting complete plan tee, elbow 45° band, \"Y\" tee, nahani drap, \"P\" trap, metal clamp with fastener complete (10 kg/cm² pressure supreme company) solvent welded joint as per manufacturers commendations, supreme 110mm dia uPVC pipe, PVC trap of self cleaning design including cost of cutting and making good floor 110x110 mm inlet & outlet PVC trap, 50mm, 63mm dia uPVC for waste & bottle trap waste pipe drain spout for sunken area (supreme 10 kg pressure pipe). for toilet and kitchen. (Make: Supreme) 50 mm .
258Providing and fixing of complete bathroom inside complete wallfloor concealed water supply pipes, soil & Waste pipe, cement work, chase cutting, hot & cold water provision water supply plumbing pipes and fitting, KITEC pipe with brass fitting (care wll pipe) pipe size: 1620mm | 2025mm dia pipe providing & fixing soil & waste pipe and fitting complete plan tee, elbow 45° band, \"Y\" tee, nahani drap, \"P\" trap, metal clamp with fastener complete (10 kg/cm² pressure supreme company) solvent welded joint as per manufacturers commendations, supreme 110mm dia uPVC pipe, PVC trap of self cleaning design including cost of cutting and making good floor 110x110 mm inlet & outlet PVC trap, 50mm, 63mm dia uPVC for waste & bottle trap waste pipe drain spout for sunken area (supreme 10 kg pressure pipe). for toilet and kitchen. (Make: Supreme)100 mm
259Providing and fixing of Rain Water pipe & fitting complete (uPVC pipe 6kg pressue supreme co.) with wall U-type metal clamp | \"C\" channel rod with fastener complet pipe joining with PVC solvent cement including all fittings Tee, elbow, socket, testing, cutting hole & cement work hole refixing complete. 110mm dia uPVC pipe
260Providing & fixing in position uPVC P\"or S\" trap of self cleaning design offollowingsizesfor the embedded areas. Making proper connection with drip-seal joints, cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. 3 x 50 mm inlet and 100 mm outlet (Multi Floor Trap)
261Providing & fixing in position uPVC P\"or S\" trap of self cleaning design offollowingsizesfor the embedded areas. Making proper connection with drip-seal joints, cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required.50 mm outlet (Floor Drain)
262Providing and fixing G.I. pipes conforming to I:S including all fittings, testing, cutting holes or chases and making good where required. (For waste connections) 32mm dia
263Providing and laying cement concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm and down gauge) 75 mm in bed and all round SCI / CILA / UPVC / GI pipes 100/75/50/40/32 mm dia soil & waste pipes under floor including shuttering and centering.
264Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : (for pipes in chase or under floors) 32mm dia
265Providing and fixing cast brass cleanout plug (Ceiling or Floor) with suitable inset keys for opening, male threaded joint with G.I. socketfixed to uPVC/SCI pipe complete in all respects. 100 mm nominal pipe size
266Providing and fixing grease trap of approved quality & make and as per the direction of Engineering-charge.
267Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. 15 mm nominal outer dia pipes.
268Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes.
269Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. 25 mm nominal outer dia pipes.
270Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. 32 mm nominalouter dia pipes.
271Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. 40 mm nominal outer dia pipes.
272Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. 50 mm nominal outer dia pipes.
273Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. 62.5 mm nominal inner dia pipes.
274Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings i/cfixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement andthe cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia pipes.
275Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings i/cfixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement andthe cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia pipes.
276Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings i/cfixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement andthe cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia pipes.
277Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings i/cfixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement andthe cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia pipes.
278Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge.External work. 20mm Nominal outer dia pipes
279Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge.External work. 25 mm nominal outer dia pipes.
280Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge.External work. 32 mm nominal outer dia pipes.
281Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge.External work. 40mm Nominal outer dia pipes
282Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge.External work. 50mm Nominal outer dia pipes
283Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge.External work. 62.50 mm nominal inner dia pipes.
284Providing&fixingball valve ( brass) of approved quality,High or low pressure, withplastic floats complete:- 25 mm dia
285Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 80 mm nominal bore
286Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 100 mm nominal bore
287Providing and fixing of best quality NRV brass half way ball valve wheel, tested shock cold working pressure upto 10kg/cm²of approved quality complete in all respect (make: ZOLOTO/KITEC) 80 mm nominal bore
288Providing and fixing of best quality NRV brass half way ball valve wheel, tested shock cold working pressure upto 10kg/cm²of approved quality complete in all respect (make: ZOLOTO/KITEC) 100 mm nominal bore
289Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore
290Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
291Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
292Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
293Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore
294Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Fire Water Tank
295Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Domestic Water tank
296Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) 80 mm dia nominal bore
297Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter
298Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :200 mm diameter
299Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 250 mm diameter
300Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :300 mm diameter
301Providing and laying uPVC pipe solvent cement, including excavation or dressing comlete/wall hung steel bracket complete.160mm dia uPVC pipe (10kg/cm²)
302Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
303Providing and laying cement concrete 1:3:5 (1 cement : 3 coarse sand : 5 grated stone aggregated 20mm and down gauge) 75mm in bed all round uPVC soil water and rain water pipe under floor including shuttering and centering bed concrete 15cms thick as per standard design 160mm dia uPVC pipe
304Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 60x60 cm and 45 cm deep including C.I. cover with frame (light duty) 455x455 mm internal dimensions, total weight of cover and frame to be not less than 25 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
305Providing & Fixing of SW maser trap with water seal (last manhole) complete with cement consrete fixing, uPVC suprem co. 160mm dia
306Extra for depth for manholes :Size 60x60 cm With Sewer bricks conforming IS : 4885
307providing & fixing of aquare mounth S.W/PVC gully trap grade \"A\" complete with C.I. grating brick masonary chamber and water gigit C.I. cover with frame 300 x 300mm size inside \"heavy\" as per standard design 100 x 100mm size \"P\" type with FBS brick of class designation 75.
308Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
309Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
310Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia. R.C.C. pipe
311Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia. R.C.C. pipe
312Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
313Constructing brick masonry catch basin with conventional bricks in cement mortar 1:4 (1 cement: 4 coarse sand) FRPlight duty cover with frame, Size 600 x 600 mm up to 600 mm deep & 600x600 mm above 600 mm deep , R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone. Aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design.
314Construction of Rain water harvesting filter chambers of 2000mm x 1000 mm x 1000 mm depth including the light duty chamber cover and filling as specified in the Dwg . Excavation, backfilling and compaction, dewatering / souring if required.
315Providing and constructing Rainwater harvesting pit of 3000 (Dia mm) X 3000mm (D) size (Internal) in overall size with inlet and outlet connection with upto 150mm from ground level 1st class brick 230mm thick in Cement mortar 1:4 (1 Cement : 4 Coarse sand) inside and outside 12mm thick plaster with Cement mortar 1:3 (1 Cement : 3 Coarse sand) with a floating coat of neat cement on inside surface. After 1500, depth 500mm thick border. C.I. (heavy duty) manhole cover 560mm (weight not less than 208 kg) including necessary excavation ( all type SOIL hard-rock)backing filling, disposal of surplus earth, providing and fixing of C.I. manhole steps complete as per standard design.
316Sump PumpProviding and fixing compact monoblock dry motor submersible pumps of suitable rating, with non-clog free flow open impeller, suitable for operation on 415 volts +10% , 3 Phase, 50Hz,A.C supply, speed 2900 RPM including oil chamber, guide wire for lifting & lowering of pump, M.S. galvanized lifting chain, duck foot bend complete. The pump setsshall be supplied with required accessories & as per specification with the following : Complete inlet, outlet and header piping of suitable dia (velocity shall not exceed 1.5m/s) -- 1 Lot Butterfly valve and Dual Plate NRV of appropriate dia and rating - 1 Lot Necessary cables from pump sets to pump starter panel - 1 Lot Electrical control panel having all necessary accessories &safetydevices of standard specifications and suitable for receiving incomer cable to connect complete. (Panels with sump pumps near each sump as per site conditions). -- 1No. Discharge :5 m3/HrHead : 12 mSolid Handling : 65 mmNote : Pumps shall be operated on cyclic timingThe entire system along with pumps & control panel must besourced from single manufacturer only for unit responsibility. One set consist of 2 nos.of pumps - 1 working & 1 stand by (Complete set as above with 2 nos. pumps including cost for valves, piping, Control Panel and Cabling, Level Controllers, pressure gauges etc as required and as specified)
317Providing, Fixing,testing and commissioning of package type skid mounted hydropneumatic system comprising of:Horizontal / Vertical inline single/multistage centrifugal pumping set with stainless steel stage casing and S.S. impellers with stainless steel shaft, cast iron suction& discharge casing, connected to suitable capacity TEFC ventilated induction motor 2 pole, 2900rpm, suitable for 415±10% Volts, 3 phase, 50 Hz A.C. supply.Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, likehigh density polyethylene with fully replaceable polyurethane. Air cell burstpressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. No. and capacity of Pressure Vessel - 01 No. x 100 Ltrs. Electrical Control Panel including provision for cyclic operation of pumps - Pump working sequence should change after every operation. Control panel with programmable logic controller (PLC) with in builtPID controller, digital display with fluorescent screen, 3 ph, 415±10%V, AC variable speed drives (Nos. of VFD\"s same as that of pumps including standby) of suitable capacity rating with in built EN55011 class A RFI filters, having standard function of BI loop, energy saving catching a spinning load with speed search, auto hunting jog preset speeds, controlled stop on loss of supply power loss side through, DDC injection breaking fast stop. Drive should have selectable rated input frequency 50/60 Hz and output frequency range of 0.5-32 Hz, contactors, overload relays and MCBs shouldconform to IEC 898-1995 standards Ammeter, voltmeter. All trip indications should blink in case of trip and panels should only be accessible through an access code. Electronic Pressure switches having maximum pressure and differentialscaleshould confirming BS-6134 standards and IP55 protection class.Complete set system tobemountedona commonMS base frameand shallfollow following duty.The cost will include making necessary flanged suction and delivery headers in GI (C class)Motor to be of the same make as the pump(Vendor to submit performance curves and technical catalog of the proposed model for review & information) The pump shall be selected for performance at best efficiency point.However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head.Domestic: Capacity : 300 LPM Each Pump (1 Working + 1 Standby) @ 50 M head.(at TERRACE)
318Providing, Fixing,testing and commissioning of package type skid mounted hydropneumatic system comprising of:Horizontal / Vertical inline single/multistage centrifugal pumping set with stainless steel stage casing and S.S. impellers with stainless steel shaft, cast iron suction& discharge casing, connected to suitable capacity TEFC ventilated induction motor 2 pole, 2900rpm, suitable for 415±10% Volts, 3 phase, 50 Hz A.C. supply. Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, likehigh density polyethylene with fully replaceable polyurethane. Air cell burstpressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles.No. and capacity of Pressure Vessel - 01 No. x 100 Ltrs. Electrical Control Panel including provision for cyclic operation of pumps - Pump working sequence should change after every operation. Control panel with programmable logic controller (PLC) with in builtPID controller, digital display with fluorescent screen, 3 ph, 415±10%V, AC variable speed drives (Nos. of VFD\"s same as that of pumps including standby) of suitable capacity rating with in built EN55011 class A RFI filters, having standard function of BI loop, energy saving catching a spinning load with speed search, auto hunting jog preset speeds, controlled stop on loss of supply power loss side through, DDC injection breaking fast stop. Drive should have selectable rated input frequency 50/60 Hz and output frequency range of 0.5-32 Hz, contactors, overload relays and MCBs shouldconform to IEC 898-1995 standards Ammeter, voltmeter. All trip indications should blink in case of trip and panels should only be accessible through an access code. Electronic Pressure switches having maximum pressure and differentialscaleshould confirming BS-6134 standards and IP55 protection class. Complete set system tobemountedona commonMS base frameand shallfollow following duty. The cost will include making necessary flanged suction and delivery headers in GI (C class)Motor to be of the same make as the pump(Vendor to submit performance curves and technical catalog of the proposed model for review & information) The pump shall be selected for performance at best efficiency point.However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. Flushing: Capacity : 250 LPM Each Pump (1 Working + 1 Standby) @ 50 M head.(at TERRACE)
319Supply, assembly, erection, testing and commissioning of pumping system comprising the following: Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gaugesincluding MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump)Domestic water transfer Pump : Capacity : 150.0 LPMEach Pump (1 Working + 1 Standby) @ 35 M head.
320Supply, assembly, erection, testing and commissioning of pumping system comprising the following: Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gaugesincluding MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump)Filter Feed Pump : Capacity : 150.0 LPMEach Pump (1 Working + 1 Standby) @ 35 M head.
321Supply, installation, testing and commissioning of SS/CI submersible pumps for domestic water pumping system comprising of:Supply, installation, testing and commissioning of free standing vertical type electrical submersible pump sets of following capacity capable of domestic water supply in tube well, with water cooled electric motor for effective cooling, the wearing parts such as Impeller, shaft sleeve, pump casing etc. shall be C.I & Impeller bolt shall be AISI 316 and of adequate power for operation on 415+ 1 volts, 3 phase, 50 Hz AC electric supply including fixing of delivery pipe with a flanged outlet. The cost will include providing and fixing suitable standard electrical panel from the same manufacturer as the pump, including float type level controller for level control and for cyclic operation of pumps, all electrical cables including submersible cables of required length and making all necessary electrical connections, terminations etc. complete in all respects.The pump shall be selected for performance at best efficiency point.However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. For tube well water supply Capacity : 200 LPM Each Pump (1 Working + 1 Standby) @ 50 M head (location in tube well).
322Supply, assembly, erection, testing & commissioning of vertical M.S. Dual Media filter fabricated from 6mm thick M.S plate shell and 8mm thick M.S. plate dished ends with 3mm non-toxic, non-leaching rubber lining (rubber lining to be tested for pin-holes by spark tester) inside complete with initial charge of filter media activated carbon, face piping (GI, C Class), diaphragm/ball/non-return valves, accessories, painting, testing and commissioning of any under drainage system as required, complete. (Tested to 10 kg/sq cm) Capacity:150 lpm Filtration rate :18-20 M³/M²/hr Max. operating pressure:3.5 Kg/Sq.cm Test pressure:5.5 Kg/Sq.cm
323Supply, assembly, erection, testing & commissioning of vertical M.S. Activated Carbon filter fabricated from 6mm thick M.S plate shell and 8mm thick M.S. plate dished ends with 3mm non-toxic, non-leaching rubber lining (rubber lining to be tested for pin-holes by spark tester) inside complete with initial charge of filter media activated carbon, face piping (GI, C Class), diaphragm/ball/non-return valves, accessories, painting, testing and commissioning of any under drainage system as required, complete. (Tested to 10 kg/sq cm)Capacity:150 lpm Filtration rate:15-17 M³/M²/hr Max. operating pressure:3.5 kg/Sq.cm Test pressure:5.5 Kg/Sq.cm
324Supplying, assembly, erection, testing and commissioning of magnetic level sensors and controllers, CPVC probe tube, PP actuating float and all other equipment required for the performance of the system to the satisfaction of the engineer in charge complete including providing and fixing wiring from control junction box near the UG tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. The level controller will perform the following functions.To switch on the pumps (including tube well pumps 2 nos., raw water pumps (Domestic Water Treatment, Softening Plant, RO Plant, Domestic, Flushing and Soft Water Makeup Tanks at Terrace etc.) when the level of water in the supply water tank is lowandto cut off the pump when the level in thereceiving watertank is high and switch off the pumps when the level of water in the supply water tank is low. To indicate 2 levels of water in all tanks through a control panel with LEDs To start the pumps in a cyclic order.The system shall be complete to ensure automatic quotation of pump in accordance to water level in respective tanks.The Contractor will include all the under ground and over head tanks and all the pumps as required for level control in this item
325Providing, fixing, jointing and testing in position the followingheavy class G.I. pipes conforming to IS:1239 cutto requiredlengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions,reducers,flanges & plugs etc. fixing atby clamps, hangers etc, (to be galvanized after fabrication) making fire sealant complete as required. Including twocoats ofSynthetic enamel paint of approved shade on pipes and supports as per pipe colour codeover acoatofprimer. 65 mm dia
326Providing, fixing, jointing and testing in position the followingheavy class G.I. pipes conforming to IS:1239 cutto requiredlengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions,reducers,flanges & plugs etc. fixing atby clamps, hangers etc, (to be galvanized after fabrication) making fire sealant complete as required. Including twocoats ofSynthetic enamel paint of approved shade on pipes and supports as per pipe colour codeover acoatofprimer. 80 mm dia
327Providing, fixing, jointing and testing in position the followingheavy class G.I. pipes conforming to IS:1239 cutto requiredlengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions,reducers,flanges & plugs etc. fixing atby clamps, hangers etc, (to be galvanized after fabrication) making fire sealant complete as required. Including twocoats ofSynthetic enamel paint of approved shade on pipes and supports as per pipe colour codeover acoatofprimer. 100 mm dia
328Supplying, installing, testing and commissioning of Sodium Hypochloride dosing system consisting of one HDPE tank of 300 litres capacity with a positive displacementdiaphragm dosing pump havingvariable flow rate of 0-6 LPH.Themotor shall be suitable for operation at 240 V / singlephase /50 Hz. Supply.Thepump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch andinjection fittings.The pump shall be speed & stroke control AsiaLMI / equivalentmake.
329Providing and fixing Butter fly valve Rated for PN16 pressure rating including rubber gasket, flanges, nuts, bolts, washers & painting complete as required.65 mm dia
330Providing and fixing Butter fly valve Rated for PN16 pressure rating including rubber gasket, flanges, nuts, bolts, washers & painting complete as required. 80 mm dia
331Providing and fixing Butter fly valve Rated for PN16 pressure rating including rubber gasket, flanges, nuts, bolts, washers & painting complete as required.100 mm dia
332Providing & fixing C.I. dual plate type check valve tested to a pressure of 15Kg/sqcm. Including rubber gasket, flanges, union, nuts, bolts, washers & paintingcomplete as required.65 mm dia
333Providing & fixing C.I. dual plate type check valve tested to a pressure of 15Kg/sqcm. Including rubber gasket, flanges, union, nuts, bolts, washers & paintingcomplete as required. 80 mm dia
334Providing & fixing C.I. dual plate type check valve tested to a pressure of 15Kg/sqcm. Including rubber gasket, flanges, union, nuts, bolts, washers & paintingcomplete as required. 100 mm dia
335Providing & fixing C.I. \"Y\" Strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanges / union nuts, bolts & washers complete as required (on pump suction).65 mm dia
336Providing & fixing C.I. \"Y\" Strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanges / union nuts, bolts & washers complete as required (on pump suction).80 mm dia
337Providing & fixing C.I. \"Y\" Strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanges / union nuts, bolts & washers complete as required (on pump suction).100 mm dia
338Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications. 65 mm dia
339Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications. 80 mm dia
340DOMESTIC WATER SUPPLY PUMP PANEL (AT PLANT ROOM) Ics=35 KA Supplying, Installation, Testing and Commissioning of dust and vermin proof wall / floor mounting type factory built sheet steel enclosed cubical panel, fabricated out of 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with Aluminium bus bars, inter-connection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per specifications and as required (all the starters should have BMS compatible with required NO/NC contacts etc).INCOMING 100 A, TPN, 35 kA ratingMCB -01 No. Digital flush type class - I accuracy multifunction meter 0-250A, showing V, A, KWH, KVA, PF etc. with 3 Nos. current transformers of 250/5 Amp ratio, 15 VA Class 1.0 metering.Coloured LED (Red, Yellow, Blue) phase indicating lampsBus Bar125 Amp. 35 kA, TPNCu. Bus BarOUTGOING40A, TP,10 kA \"C\" series MCCB, coloured LED type ON indication - (1w+1s) 1 Nos & 1 Spare25 TP,10 kA \"C\" series MCCB, coloured LED type ON indication - (1w+1s)1 Nos & 1 Spare 25A, TP, 10 kA \"C\" series MCCB, coloured LED type ON indication -(1w+1s) 1 Nos & 1 Spare25A, TP, 10 kA \"C\" series MCCB, coloured LED type ON indication -(1w+1s) 1 Nos & 1 SpareFully automatic DOL starter suitable for 2.5 HP motor including 40 A TP MCCB \"C\" series, CT\"s, Ammeter, Push Button, Indicators, Auto/Manual/OFF switch, SPPR, Relay, metering & indication etc.- (1w+1s) 1 Nos (Borewell Pump)Fully automatic DOL starter suitable for 5.0 HP motor including 25 A TP MCCB \"C\" series, CT\"s, Ammeter, Push Button, Indicators, Auto/Manual/OFF switch, SPPR, Relay, metering & indication etc.- (1w+1s) 1 Nos.(Hydrapneumatic Pump)Fully automatic DOL starter suitable for 2.0 HP motor including 25 A TP MCCB \"C\" series, CT\"s, Ammeter, Push Button, Indicators, Auto/Manual/OFF switch, SPPR, Relay, metering & indication etc.- (1w+1s) 1 Nos.(Filter feed Pump)Fully automatic DOL starter suitable for 1.0-2.0 HP motor including 25 A TP MCCB \"C\" series, CT\"s, Ammeter, Push Button, Indicators, Auto/Manual/OFF switch, SPPR, Relay, metering & indication etc.- (1w+1s) 1 Nos.(Soft & Cooling Tower Pump)Fully automatic DOL starter suitable for 1.0-2.0 HP motor including 25 A TP MCCB \"C\" series, CT\"s, Ammeter, Push Button, Indicators, Auto/Manual/OFF switch, SPPR, Relay, metering & indication etc.- (1w+1s) 1 Nos.(soft water feed pump)Domestic water supply Panel. (At Plant Room)
341Fabricating and installing following size of perforated M.S. cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness
342Fabricating and installing following size of perforated M.S. cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
343Supply, laying, fixing, testing, commissioning excluding end terminations of following sizes of XLPE insulated PVC sheathed, armoured copper conductor cable of 1.1 KV grade on existing cable tray / surface as required.3 core x 10 sqmm
344Supply, laying, fixing, testing, commissioning excluding end terminations of following sizes of XLPE insulated PVC sheathed, armoured copper conductor cable of 1.1 KV grade on existing cable tray / surface as required.3 core x 6 sqmm
345Supply, laying, fixing, testing, commissioning excluding end terminations of following sizes of XLPE insulated PVC sheathed, armoured copper conductor cable of 1.1 KV grade on existing cable tray / surface as required.3 core x 4 sqmm
346Supplying and making end terminations of following sizes of XLPE insulated PVC sheathed, armoured copper conductor cable of 1.1 KV grade on existing cable tray / surface as required.3 core x 10 sqmm
347Supplying and making end terminations of following sizes of XLPE insulated PVC sheathed, armoured copper conductor cable of 1.1 KV grade on existing cable tray / surface as required.3 core x 6 sqmm
348Supplying and making end terminations of following sizes of XLPE insulated PVC sheathed, armoured copper conductor cable of 1.1 KV grade on existing cable tray / surface as required.3 core x 4 sqmm
349GI EARTH STRIP Providing and fixing25mm x 5mmG.I.stripon surface or in recess for connections etc. as required.
350GI EARTH WIRE Providing and fixing 6 SWG G.I. Wireon surface or in recessfor loop earthing along with the existing cable as required.
351STP Fully automatic Underground Sewage treatment plant-FAB technology ( with air diffuser system)below ground lavel (at basement level) with sewage handling capacity of 40 KL per day. The raw sewage collection sump with double SS bar screen shall be part of STP. STP shall be designed as water retaining structure, non-skid type, removable manhole covers. Including necessary chemical dosing as required by the manufacturer\"s design.All the equipments, piping, pumps, blowers and electricals are to be housed in a plant room at basement level. Including MS(Class-C pipe) Puddle flanges (with black Japan paint) inlet,outlet, overflow, vent, C.I. Manhole covers, drain channels with MS(painted) gratings.Contractor to exclude all civil works like construction of RCC compartments for STP,sewage sump,pump room sump,civil works for pump room,etc.All STP compartments shall be of RCC construction. The STP shall be designed based on the following parameters: Flow Rate - 40KL/day-FAB technology pH-7-9 BOD - 250 - 300 mg/lt.COD - upto 800 mg/lt.SS - upto 400 mg/lt.Oil ,Grease and ABS - upto 75 mg/lt.Ecoli MPN/100ML - 1000000Hardness - PPM - 200The treated sewage shall have following characteristics:pH- 7.0 - 7.5BOD -less than 20 mg/lt.COD -less than 60 mg/lt.SS - Less than 20 mg/lt.Oil & Grease and ABS - less then 5mg/lt.Ecoli MPN/100ML - 1000Hardness - PPM - less than 05Sewage treatment plant shall include the supply, installation, testing and commissioning of the following items:SS Bar Screens Size : 1200 x 800MOC : SS 304Qty : 02 Nos
352Non clogging type submersiblepumps capableofhandlingsolidsup to 50 mm having SS. casing&SS impeller completewithallaccessories, valves, headers etcmotor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automatically.Pumpsshall have following duty: Raw Sewage Transfer PumpsFlow rate (each) = 2500 lph Head= 12-15 MtrQty = 02 Nos (1W + 1SB)
353Non clogging type centrifugalpumps capableofhandlingsolidsup to 8 mm having C.I. casing&CI impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automatically.Pumpsshall have following duty: Sludge Re-circulation PumpsFlow rate (each)=2100 lphHead= 8 MtrQty = 02 Nos (1W + 1SB)
354Non clogging type centrifugalpumps capableofhandlingsolidsup to 8 mm having C.I. casing&CI impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automatically.Pumpsshall have following duty: Sump Pumps for plant room drainageFlow rate (each)=10800 lphHead= 15 MtrQty = 02 Nos (1W + 1SB)
355Non clogging type screwpump capableofhandlingsolidsup to 8 mm having C.I. casing&CI impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automatically.Pumpsshall have following duty: (Make : Roto)Filter Press Feed PumpFlow rate (each) = 800 lphHead = 30-35 MtrQty = 02 Nos ( 1W + 1SB)
356Airdiffusionsystemshall include the following:2Nos.air blower (one working&one standby) capable ofdelivering 50 m3 of free air each at5000 MMWG driven through “V” belt ordirectly coupledthrough flexible coupling to a TEFC motor of suitable HP suitable for 415 ± 10% volts, 3 phase, 50 cycles A.C. supply.- 1 Set.
357G.I(heavy ClassC) conforming to IS:1239- 1982completewithG.I fittings ® brand such as tees,crosses,
358plugs, sockets, elbows, reducers, supports&clamps, puddle flanges etc cutting chases& making good including epoxy coating the pipeswith desired shade of colour coding over a coat ofprimer (Air piping). - 1 Set. (Make Jindal Hissar)Non clog type airdispersion systemcapable of handling 3-5cfm of airwith oxygen transferefficiency of3-4% per/meterwaterdepth.Air dispersion gridshall be assembled in modular formso thatthey canbereplaced/ repaired easily from platform at the top. Airdispersion systemshall be provided for sewagesump, Aerobic digester cum Thickener & Aeration Tank.Flexible pipes completewith stainless steel fittings such as tees,crosses, plugs, sockets, elbows, reducers, supports&clamps, puddle flanges etc cutting chases& makinggood for submerged air piping.
359Centrifuge for compression, management & disposal.
360Centrifugalpumps having C.I. casing&CI impeller completewithallaccessories, valves, headersmotor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) Pumpsshall have following duty: Filter Feed PumpsFlow rate (each) =5000 lphHead= 35 MtrQuantity= 02 Nos (1W / 1S)
361Supplying, installing, testing and commissioning of tertiary treatment systems comprising of a MSEP pressure sand multigrade filter(shell 6mm & dished ends 8mm)with Frontal Piping, 5 Valve Battery. Filter shallbe suitable for flow rate of 5000 LPH at 3.5 Kg/Sqcm working pressure.(Make: Ion Exchange /Thermax).Velocity (Max) : 12500 Ltr/Hr/Sq.Mtr.
362Supplying, installing, testing and commissioning of tertiary treatment systems comprising of a MSEP Activated Carbon filter (shell 6mm & dished ends 8mm)with Frontal Piping, 5 Valve Battery. Filter shallbe suitable for flow rate of 5000 LPH at 3.5 Kg/Sqcm working pressure (Make : Ion Exchange /Thermax).Velocity (Max) : 12500 Ltr/Hr/Sq.Mtr.
363GI(heavy Class C) conforming to IS:1239- 1982completewith mild steel fittings ® brand such as tees,crosses, plugs, sockets, elbows, reducers, supports&clamps, puddle flanges etc cutting chases& making good includingepoxy coating the pipeswith desired shade of colour coding over a coat ofprimerpiping before tertiary treatment. -1 Set. (Make Jindal Hissar).
364FAB Media Make : Cooldeck / Welcome / Pharmatech
365Tube Settler Media PVC Tube Media of 750 mm height .Make : Cooldeck / MM Aqua
366Electrical Panel Supply Installation, testing & commissioning of Electrical Panel suitable for 415 V, 3 Phase, 4 wies, 50Hz power distribution system. The panel shall be free standing floow / wall mounted, sheet metal enclosed flush front dust & venim proof with Aluminium bus bars. The painting shall be done as per relevant ISI codes as specified. Adequate size cable alley shall be provided for each cable bending & termination. (All components would be L&T/Schnieder /GE). Including electrical wiring for electrical connection of equipments.with cable trays ets.complete.
367Supply, Installation, Testing & Commissioning of Ozonator to treat 5000 lph water suitable for waste water application. Capacity:100gm/hr.
368Supply, installation, testing& commissioningof chlorinedosing system consisting of one FRP/ HDPE tank of 100 liters capacity with a positive displacement diaphragm Dosing pump with a variable flow rate of 0-12 LPH. Themotor shall be suitable for operation at 240 V /one phase/ 50 Hertz supply. The pump shall be supplied complete with necessary poly propylene piping, valves, strainers & injection fittings for system to dose solution to the feed line. The pump shall be Asia LMI make. (Location : Pump Room for STP).
369INSTRUMENTATIONSewage flow Measurement - Electro Magnetic type flow measurement for input & output Sewage flow. -2nos.Air Flow Rate meters - Inlet to FAB tanks-2nos.Level Switch - Equalisation tank, filter feed tank Sludge holding tank & treated water tank.-4 nos. Online PHmeter - Online after ACF-1no. Digital Energy meter - Panel Mounted-1no. Level indicator for treated water tank-1no.& water meter at inlet to treated water tank.
370PUMP EQUIPMENT & ACCESSORIESSupplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.2280 lpm at 70 m Head
371Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.2280 lpm at 70 m Head
372Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation,conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head
373Supply, Installation, Testing and Commissioning of Electric Driven Main Fire Pump (Water Curtain System) suitable for auto operation & consisting of following: complete in all respect as required.The pump shall also be capable of discharging not less than 150 % of the rated discharge at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of the rated head. Horizontal end suction type, centrifugal, single stage, pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 1.4 kg/sq. cm. at highest and farthest outlet at specified flow of 900 lpm at 60 Mtr. head confirming to IS 1520. Suitable HPsquirrel cage induction motor, TEFC synchronous speed 2900 RPM (with permissible slip), suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class- \"F\" insulation, confirming to IS-325.Common base frame fabricated out of M.S channel of suitable size, flexible coupling, coupling guard, foundation bolts and pressure gauge , pressure switch with valve etc. Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per manufacturer\"s design & standards and as per detailed specifications.
374Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.200mm dia
375Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. 150mm dia
376Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. 80mm dia
377Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.200mm dia
378Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.150mm dia
379Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.100mm dia
380Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required. 80 mm dia
381Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 200 mm dia
382Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required.150 mm dia
383Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required.100mm dia
384Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required.80 mm dia
385Providing & fixing100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg ) range, 3 / 8 \" BSP bottom entry on Pump Delivery Line complete with Ball valve
386Supplying andfixingair vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm. in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm diagun metal wheel valve, with required accessories, pressure gauge a and painting with synthetic enamel paoint of approved shade as required.
387Fabricating, Supplying, Installation, Testing and CommissioningAir Vessel of continuous welded construction with flanged discharge header on the top of each riserfabricated out of 8 mm thick MS sheet, Air Release Valve complete with suitabledrain arrangement with 25 mm dia gun metal ball valve complete with all accessories etc. pressure gauge, synthetic enamel paint of approved shadeas required of the following sizes 2 Meter high and 450 mm dia suitable to operate Jockey Pump, Main Fire Pump , Sprinkler pump & Diesel Engine Driven Fire Pump
388Providing and fixing Pressure switch in the MS pipe Line including connection etc. as required.
389Providing & fixing testing & commissioning of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 100 mm dia and obtaining NOC from local bodies etc required.
390Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required Incomings 630A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800AmpsOutgoingsNote : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump 200 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 setsJockey Pump100 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 setsDiesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
391Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal
392Supplying andfixing first -Aid hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with the following as required.a) 20/30/40m long 20mm (nominal internal) dia water hose thermoplastic (textile reinfirced ) type -2 as per IS 12585b) 20mm (nominal internal) dia gun metal globe valve and nozzle.c) Drum and brakets for fixing the equipments on wall.d) Connections from riser with 40 mm dia stop valve (gun metal ) and M.S. pipe
393Supplying andfixing 63mm dia, 15 mtr long RRL hose pipe with 63mm dia male and female gun metal couplings duly binded with GI wire, rivets etc. confirming to IS 636 (type-A)as required.
394Supplying andfixing63mm gun metal branch pipe with 20 mm (nominal internal diameter) size gun metal nozzle conforming to IS 903, suitable for instaneous connection to interconnect hose pipe coupling as required.
395Supply & Fixing of Fire Man\"s Axe with heavy Insulated rubber tested up to 20 KV and confirming to IS ;926 as required.
396Providing & fixing100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg) range, 3 / 8\" BSP bottom entry on Pump Delivery Line complete with Ball valve
397Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.150 mm dia
398Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.100 mm dia
399Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.80mm dia
400Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.25 mm dia
401Supplying andfixing orifice plate made of 6mm thick stainless steel with orifice of required size in between flanged and landing valve ofexternal and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm complete as per specification as required
402Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.150 mm dia
403Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.100 mm dia
404Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.80 mm dia
405Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.65m dia
406Providing andfixing angle iron (40mmx40mm x5mm) door frame and MS sheet (2mm thick) cum glass shutter of size 2.1 mtr. X 0.9mtr. (N.S.) with 25mmx25mmx3mm angle frame all around and stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint including sign writing on glass at internal hydrant including providing and fixing M.S. sheet 2 mm thick on remaining portion above door to close opening including painting etc. as required.
407Supplying andfixinghose cabinet of size 900mmx600mmx500mm made of 2 mm thick MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15mtr. Long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform & duty painted with post office red externally and white internall with synthetic enamel paint complete in all respects for external hydrant, as directed by enginner-in-charge.
408Supplying andfixing 4 Way Fire brigade inlet connection of cast iron body with 4 nos. gun metal male instantaneous inlet couplings complete with cap and chainas required. For 100mm dia MS pipe connection, confirming to IS 904 as required.
409Supplying andfixing 4 Way Fire brigade outlet connection of cast iron body with 4 nos. gun metal male instantaneous inlet couplings complete with cap and chainas required. For 100mm dia MS pipe connection, confirming to IS 904 as required.
410Providing,fixing,testing and commissioning of one number Gun metal fire brigade section hose coupling (Fire brigade withdrawal connection) i/c foot valve in the bottom etc. as per specification complete as required. (M.S pipe of 100 mm dia will be paid in pipe item.)
411Providingandconstructingmasonrychamber 90 x90x100cms inside withbrick work in cement mortar 1:5 (1cement : 5fine sand) for water meter ,M.S. cover (6mmthick sheet with locking arrangement, 600 x600 with M.S. frame etc. all epoxy coated and R.C.C. top slab 1:2:4 mix(1 Cement : 2 coarsesand : 4 graded stone aggregate 20mm nominalsize) including necessary excavation, back fillingfoundation concrete 1:5:10 mix (1 cement : 5 fine sand and10 graded stone aggregate 20mmnominal size) leaving a pocket of 30x30 cmwith out concrete and filled with pebbles andinside plastering withcement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finishedwith a floating coat of neat cement and outside plaster finished rough complete.
412Supplying, fixing, testing and commissioning of 25mm Air release valve including 25mm ball valve as per IS:14845 ISI Marked.
413Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.25 mm dia
414Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. 32 mm dia
415Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.40 mm dia
416Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.50 mm dia
417Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.65 mm dia
418Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.80 mm dia
419Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.100 mm dia
420Providing laying, testing and commissioning of class \"C\" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.150 mm dia
421Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories Pendent Sprinkler
422Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories Upright Sprinkler
423Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories Horizontal side wall sprinkler
424Providing & fixing electricaly operated flow indicating switches in sprinkler branch line on each floor with ncessary junction box installed in accessible place (Wiring from switches to panel not included)100 mm dia
425Providing and fixing of carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindricalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Capacity 4.5 Kg.
426Providing and fixing of ABC Powder type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Capacity 4.0 Kg.
427Providing and fixing of ISI marked (IS:2878) Fire and wall suspension bracket, Extinguisher, Trolley mounted carbon-dioxide type capacity 22.5 Kg. Flat base including valve, discharge hose of not less than 10mm dia 1m long complete in all respects including wheeled trolley, carrying handle and initial fill with CO2 gas as per IS: 307-1996 filled to a filling ratio of not more than 0.667.
428SUBSATION EQUIPMENTS TWO POLE STRUCTURE WITH GO-DO SWITCHSupplying, fixing, testing and commissioning oftwo pole structure for receiving 11 KV 3 phase incoming line for dept. comprising of:-2 nos11 mtrs long, Steel pole as per sate electicity board(SEB) specifications.Cement Concrete foundation (1:2:4), 2250 mm below ground and 450 mm above including excavation and refilling etc as shown on drawings. Steel cection, channels, angles, flats, clamps, GI nuts, bolts and required hardware etc. of different sizes for cross arms, bracings, supports for pole, insulators, lightning arrestors, GO switch, GI pipe for 11 KV cables, supports for terminations, including anti climbing barbed wires, danger plateas per specification of SEB. 11 KV class disc / pin / support insulator complete with clamps and fixing hardware etc. 3 nos , one per phase ,11 KV station class thyrite type lightning arrestors complete with mounting arrangement on the incoming overhead line along with earthing connections complete as per specification and as required. 1 set of G.O. Air break switch with DO fuse 400 Amp. With gang operated devices, with pad locking arrangement. Operating rod, supports, complete with operating handle and locking arrangement complete as per UHBVN.specification and asrequired. 50 Mtrs.-size 6/1/4.09 mm ACSR Conductor and connectors for tapping the connection and for connections with in two pole structure with heat shrinkable insulating sleeves for protection of connections etc as shwon on drawing.50 mtrs-Earth connection with 50 x 6 mm GI Strip. SUPPLY & INSTALLATION OF TWO POLE STRUCTURE WITH GO-DO SWITCH
42911 KV ENERGY METER Supply, fixing , testing and commissioing of Energy meter for the 11 KV connections including testing of the meter by SEB lab and control cabling from CTPT to the meter complete with all respect as per the norms and the requirement of SEB.
43011 KV HT SYSTEM INCLUDING TRANSFORMER AND 11KV HT PANELSupply andinstallation testing & commisioning of1000kVA transformer step down outdoor type complete with standard fittings HT 11 KV3 phase 4 wirecopper wound, delta/star connected (vector group-DYn -11), On load Tapp Changer on HV side , oil immersed, naturally oil cooled (ONAN),Distribution transformer complete with following:- Silica gel breather with connecting pipe and oil seal.Air release plugs.Pressure release device.Explosion vent, should be double diaphragm type.150mm dial magnetic oil level gauge with low level alarm contact. 150 mm dial oil temperature indicator with maximum reading pointer and electrically separate contacts for trip and alarm. 150 mm dial winding temperature indicator with maximum reading pointer and electrically separate sets of contacts for trip and alarm.Thermometer pockets.Oil conservator with filter cap, drain plug and plain oil level gauge (with coloured prismaticfront).Double float Buchholz relay with gas release cock, shut-off valve on either side and separate sets of contacts for trip and alarm.Sampling valve/ Filter valve with threaded adopted (top and bottom).Drain valve with threaded adopted.Jacking pads, handling and lifting lugs.Cover lifting eyes. Bi-directional rollers and skids( 4 Nos. Roller) Radiators (Detachable type). Clampingdevices.Twogrounding pads. Remote tap changer control panel.( RTCC) Weatherproof marshalling box for housing control equipment and terminal connections.Rating and terminal marking plates.LT Neutral bushing with 50x10 cu flat suitably supported Outdoor HT cable box (Detachable type) suitable to terminate 3C-240 sq. mm 11kV HT cable.LT side suitable for 2500A outdoor type Aluminium Bus Duct/Cable.1250 KVA Transformer as per above
43111kV HT PanelSupply , Installation, Testing and Commissioning of11 kV, 350 MVA (18.4 kA), 630A, HT, Single Panel Vacuum circuit breaker Switchboardcubicle type, made out of 2mm thick sheet steel, totally enclosed, IP 4X, 50 deg. C ambient temperature, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, powder coated painting, suitable for operation on 11 kV , 3ph, 50 Hz AC system with copper busbars, Vacuum circuit breaker mounted on horizontally withdrawable truck complete with following and as per technical specifications and enclosed SLD1 Vacuum Circuit Breaker - 630 A, 3 pole, 18.4 kABreaker control switch.( TNC)24 V DC Tripping coil 24 V DC Closing coil 240 V AC spring charge motorSet of ON/OFF indicating lamps , R-Y-B Indication Lamps , Spring Charged Indication Lamp and Auto Trip Indication lampClear lamp for trip circuit health supply.Digital ammeter with selector switch. Digital Voltmeter with selector switch. 8 Parameter Energy Analyser 3 Nos. VAA33 aux. relay for transformer faults , A;arm and trip suitable for 230V AC supply 1 No. Anti Pumping Device Trip circuit supervision relay. Master Trip relay. IDMT Relay with 2 O/C and 1 E/F Element with hand reset contacts and indicator( Flag) ( O/C Settings 400-1600% and E/F Setting 200 - 800%) with highest instantaneous protection for O/C and E/F ( Self powered Version) Earth fault relay range 20 – 80% with series stabilizing resistor and PS class CT’s. 3 Nos. Cast resin CTs of dual ratio 60/30/5-5 Amps CL:1 ( For Metering) , 5P20( For protection) , 15 VA. Alarm annunciator with 9 windows and buzzer, ACK, rest, test push button for transformer faults and electrical faults. Suitable rating DC power Pack 1Set Suitable space and Brass Gland for termination of 1 No. 3C x 240 sq.mm XLPE cable as incoming.and Outgoing 11kV HT panel as described above and complete as required (1no. near HT Meter Room & 1no near T/F)
432H.T & L.T CABLESupply of cable XLPE -PVC insulatedPVC sheathedgalvanised steel strip armoured electric power cablewith aluminium conductor 11000 volt grade of size 3CX240 sqmm.
433Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of grade exceeding 1.1 KV but not exceeding 11KV of size not exceeding 120 sq mm but not exceeding 400sq mm direct in ground including excavation, sand cushioning, protecive covering and refiling the trench etc as required.
434Laying of one number PILCA/PVC insulated and PVC sheathed / XLPE power cable of grade EXCEEDING 1.1 KV but not exceeding 11 KV ofsize not exceeding 120 sq mm in the in the existing RCC/ HUME/STONE WARE / METAL pipe as required.
435Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 sq. mm
436Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 sq. mm
437Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.1/2 core300sq. mm.
438Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.1/2 core 240sq. mm.
439Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.1/2 core185sq. mm.
440Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.1/2 core150sq. mm.
441Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.1/2 core120sq. mm.
442Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.1/2 core70sq. mm.
443Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.1/2 core50sq. mm.
444Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.1/2 core35sq. mm.
445Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.3.5 core25sq. mm.
446Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.4 core16sq. mm.
447Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.4 core10 sq. mm.
448Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.4 core10sq. mm.( Copper)
449Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.4 core4sq. mm.( Copper)
450Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.7 core1.5sq. mm.( Copper Control cable)
451Supplyingoffollowing 1100 voltgradeXLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specificationas required.12 core1.5sq. mm.( Copper Control cable)
452Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 25 sq. mm
453Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 25 sq. mm and upto 120 sq. mm
454Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
455Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
456Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
457Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
458Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.Upto 25 sq. mm
459Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.Above 25 sq. mm and upto 400 sq. mm
460Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing mansory open duct as requiredUpto 25 sq. mm
461Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing mansory open duct as requiredAbove 25 sq. mm and upto 400 sq. mm
462Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core 300sq. mm.
463Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core 240sq. mm.
464Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core185sq. mm.
465Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core150sq. mm.
466Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core120sq. mm.
467Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core70sq. mm.
468Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core50sq. mm.
469Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core35sq. mm.
470Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.3.1/2 core25sq. mm.
471Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.4core16sq. mm.
472Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.4 core10sq. mm.
473Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.4 core10sq. mm.( Copper)
474Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.4 core4sq. mm.( Copper)
475Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.7 core1.5sq. mm.( Copper Control cable)
476Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.12 core1.5sq. mm.( Copper Control cable)
477Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.( Powder coated shall be of Siemens Grey Colour- RAL 7032) 600mm width X 50mm depth X 2.0 mm thickness
478Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.( Powder coated shall be of Siemens Grey Colour- RAL 7032) 450mm width X 50mm depth X 2.0 mm thickness
479Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.( Powder coated shall be of Siemens Grey Colour- RAL 7032) 300mm width X 50mm depth X 1.6 mm thickness
480Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.( Powder coated shall be of Siemens Grey Colour- RAL 7032) 150mm width X 50mm depth X 1.6 mm thickness
481Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.( Powder coated shall be of Siemens Grey Colour- RAL 7032) 100mm width X 50mm depth X 1.6 mm thickness
482Supply, erection, testing & commissioningof prefabricated MSladder type cable trays includingTees / Bends / Crossing / Reducers / Couping to be laid in cable trench, overhead on wall or hanged from ceiling complete with all accessories as required including support at every 1500mm as required900 mm width X 75 mm depth X 2.0 mm thickness
483Supply, erection, testing & commissioningof prefabricated MSladder type cable trays includingTees / Bends / Crossing / Reducers / Couping to be laid in cable trench, overhead on wall or hanged from ceiling complete with all accessories as required including support at every 1500mm as required750 mm width X 75 mm depth X 2.0 mm thickness
484Supply, erection, testing & commissioningof prefabricated MSladder type cable trays includingTees / Bends / Crossing / Reducers / Couping to be laid in cable trench, overhead on wall or hanged from ceiling complete with all accessories as required including support at every 1500mm as required600 mm width X 62.5 mm depth X 2.0 mm thickness
485Supply, erection, testing & commissioningof prefabricated MSladder type cable trays includingTees / Bends / Crossing / Reducers / Couping to be laid in cable trench, overhead on wall or hanged from ceiling complete with all accessories as required including support at every 1500mm as required450 mm width X 50 mm depth X 2.0 mm thickness
486415V LT PANELSDesign, fabrication, assembling, wiring & supply,installation, testing & commissioning of MV Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCApainted sheet steel in cubicle formation with reinforcement of suitable size angle iron,channels, T irons, flats wherever necessary for large meterboards. Cable gland plates shall be provided at top and bottom both and windows for meter reading, locking arrangement (pad-lock & seal) with wiring upto KWH meter &meter to MCB shall be done by using adequately rated flexible singlecore copper wire. The boards shall be treated with all anticorrosive process before painting as per standards with final approved shade of powder coated as approved, 2 nos. earthing terminalsshall be provided for all panels.The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hzsupply system. Boards shall be fabricated in length, height, depth etc to match with siteconditions. An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shallbe used in fabrication of boards. Note: The following provisions shall be required to be made in the switchboard detailed belowThe Switchboard shall have provision for entry of all PVCA cables/bus duct from the top/bottom as required.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used.Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever requiredControl circuits includes breaker control switch, auto manual selector switch, anti pumping relay, spring charging trip indication, TIMER, control wiring, Auxiliary contactors MCB’s as required at site. Positive isolation of all breakers.All fault level breaking capacity indicates shall be IC.S value at 415 volts (ICS = ICU = ICW = 100%).Space Heater/ light/air filter shall be provided for each vertical compartmentPadlocking facility shall be provided on all outgoing feeders.All ACB’s shall have all standard accessories such as CT’s, Arc Chute, Safety Shutters etc. All inter Panel wiring from PLC to DG / Transformer / Bus Couplers as required. Link and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB ratings at same current density as of Main Bus Bar2 nos. GI earth strip throughout the panel. Main LT Panel Incoming: (TRANSFORMER)1 Nos. 2000 Amps, 415 V, 50kA four poledraw out, Electrically operated ACB, with ON/OFF/TRIP/Trip circuit healthy,Spring charged indication lamp and TNC control switch, undervoltage & shunt trip release, anti pumping protection microprocessor based overcurrent, selective short circuit, intentaneousshort circuit and Earth Fault / (LSIG)protection etc. complete as required for Transformer Supply Feeder.Metering & indication and Annunciation for Transformer Supply incomingbreakers :Each Incomming breaker shall be provided with the following:One (1) No. Digital Multifunction meter with RS-485 port suitable for measurement of voltage, currents, Power Factor, Frequency, Power & Energy (Conzerv EM 6400 or equivalent) with one set (3 Nos.) of CTs of suitable rating Class 1.0, 15VA.One set (3 nos.) phase indication lamps with control MCB.One (1) set ofsuitable rating C.L 1.0CTs for input to APFC relay.Protection Relays & Interlocking for transformer breaker: Transformer breaker to be provided with : One (1) no. REF (CAG14)or equivalent relay with stabilising resistance for transformer REF protection with 4 nos. 2000/1A,CL-PS CTs of suitable VA and knee point voltage. Trip Circuit supervision relay (VAX-31 of Areva or Equivalent). Master trip relay (VAJH-13 of Areva or Equivalent). Incoming: (D.G SET) 1 Nos. 1250 Amps, 415 V, 50kA four poledraw out, Electrically operated ACB, with ON/OFF/TRIP/Trip circuit healthy,Spring charged indication lamp and TNC control switch,undervoltage & shunt trip release, anti pumping protection microprocessor based overcurrent, selective short circuit, intentaneous short circuit and Earth Fault / (LSIG)protection etc. complete as required for Transformer Supply Feeder. 1 Nos. 1000 Amps, 415 V, 50kA four poledraw out, Electrically operated ACB, with ON/OFF/TRIP/Trip circuit healthy,Spring charged indication lamp and TNC control switch,undervoltage & shunt trip release, anti pumping protection microprocessor based overcurrent, selective short circuit, intentaneous short circuit and Earth Fault / (LSIG)protection etc. complete as required for Transformer Supply Feeder. Metering & indication and Annunciation for Transformer Supply incomingbreakers : Each transformer supply breaker shall be provided with the following: One (1) No. Digital Multifunction meter with RS-485 port suitable for measurement of voltage, currents, Power Factor, Frequency, Power & Energy (Conzerv EM 6400 or equivalent) with one set (3 Nos.) of CTs of ratio /1200/1000/5A Class 1.0, 15VA.One set (3 nos.) phase indication lamps with control MCB. Protection Relays & Interlocking for transformer breaker: Trip Circuit supervision relay (VAX-31 of Areva or Equivalent). Master trip relay (VAJH-13 of Areva or Equivalent). Notes :Sufficient No. of contacts terminals shall be provided in the panel as required for necessary remote operation and indications etc. Operation interlocks as per specification & drawings indicating sufficient nos. of potential free contacts for interlocking/indication annunciation/ control etc shall be provided by the bidder as required.Bus Coupler :1 no.1250 Amps, 415 V, 50KA four pole EDO ACB Bus coupler breaker complete withshunt trip release, anti pumping protection, ON/OFF/ indication etc. Electrical & mechanicalinterlocking shall be providedbetween two incomers and one bus coupler. Busbar :2Sets of 2500A, 50kA,TPN Al. Busbar insulated with heat shrinkable sleeves and shall be colour coded. Separate earth bar of 50 x 6 mm Aluminium shall be provided. Outgoings :Each outgoing feeder shall be provided with ON/OFF/ Trip indication lamps with back-up SPMCB.1 no.1250 Amps, 415 V, 50KA TP MDO ACB complete withshunt trip release, anti pumping protection, ON/OFF/ indication etc.10 No. 400A, 50KA TPN MCCB.2 No 630/500A 50KA TPN MCCB2 No 315A 50KA TPN MCCB4 No 160A 50KA TPN MCCB4 No 125A 50KA TPN MCCB 8 No 63A 50KA TPN MCCBNote : Necessary Co-ordination shall be done by the Panel Manufacturer / Vendor with the vendor of \"Gas flooding system\" for fire protection, for making suitable provisions in the panels, at the Design stage, Manufacturing stage, stage of testing at works & stage of commissioning at site.Main LT Cum Change Over Panel ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-11 and Complete in all respects)
487Capacitor Panels (400 kVAR)Incoming : One (1) No. 1250A, TPN, MDO, ACB, incomer with 10 step APFC relay with Auto/Manual selector switch, timer, aux. Contactor, louvers, Exhaust fan etc. (1600A, TPN, MDO, ACB is already included in Main LT Panel (B& C)as O/G to Capacitor Panel.Hence, not to be included here) Metering, Indication and Protection :One (1) No. digital multifunction meter for measurement of voltage and currents with selector push buttons and one set of CTs of ratio 1200A /5A, CL 1.0, 15 VA.One (1) set of RYB phase indication lamps with control SP MCB.Busbar : 1600A TPN Al. Busbar insulated with heat shrinkable sleeves and shall be color coded. Separate earth bar of 50 x 6 mm of Aluminium shall be provided. Outgoings :400 KVAR Capacitor Panel in steps of 4 nos. of 2 x 50 kVAR banks 3 nos. of 4 x 25 kVAR banks, 2 Nos. of 1 x 25 kVAR banks,2 No.of 1X 10 kVAR bank and 2 No.of 1X 5 kVAR bank Notes:Each capacitor bank should have its individual MCCB/MCB & Contactor suitable for capacitor duty including fuses for each capacitor unit as per specifications andapproved SLD.Enclosure of capacitor panel shall be liberally designed to take care of internal heat emission by capacitor unit without forced cooling and to limit the temperature rise with in permissible limit.However, louvers are allowed to facilitate extra cooling.Enclosure shall be so designed as to keep the space for Detuned reactors for future if required.Capacitors shall be ofHeavy duty grade MPP type.400 kVAR Capacitor Panel( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-14 and Complete in all respects)
488Ground Floor MDB ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
489Third Floor MDB ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
490Office Space -1 Panel ( Ground Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
491Office Space -2 Panel ( Ground Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
492Exim Bank Panel ( Ground Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
493Cafeteria Panel ( Ground Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
494Certification Panel ( Third Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
495UPS MDB ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
496Office Space -1 Panel ( Third Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-12 and Complete in all respects)
497Forth Floor MDB ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-13 and Complete in all respects)
498Office Space -1 Panel ( Forth Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-13 and Complete in all respects)
499Office Space -2 Panel ( Forth Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-13 and Complete in all respects)
500Multi Purpose Panel ( Forth Floor)( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-13 and Complete in all respects)
501Basement MDB( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-13 and Complete in all respects)
502First Floor MDB ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-14 and Complete in all respects)
503Second Floor MDB ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-14 and Complete in all respects)
504Export Council Promotion Panel ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-14 and Complete in all respects)
505APEDA Panel ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-14 and Complete in all respects)
506DGFT Office Panel( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-14 and Complete in all respects)
507FIEO Office Panel( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-14 and Complete in all respects)
508Terrace Panel( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-14 and Complete in all respects)
509Transformer Local panel - In Outdoor Enclosure ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-11 and Complete in all respects)
510DG # 1 Local panel - In Outdoor Enclosure ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-11 and Complete in all respects)
511DG # 2 Local panel - In Outdoor Enclosure ( As per Enclosed Drawing No. VC-EH-RANCHI-VC-EL-11 and Complete in all respects)
512EXTERNAL LIGHTING FEEDER PILLAR (10 kA)Design, fabrication, supply of Feeder Pillar fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof outdoor type double door with reinforcement of suitable size angle iron, channel \"T\" irons and / or flats wherever necessary. Cable gland plates shall be provided at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications with 2 coats of PU paint primer and final approved shade of PU paint coating. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels.INCOMING 1 no. 63 Amp TPN MCCB, 10 KA with thermal magnetic protective releases. 1 set of phase indicating lamps with MCB.BUSBAR100A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 10 kA. Neutral busbar shall be of 100% capacity. OUTGOING2 No. 40A FP MCB 2 No. 40A DP MCB 2 No. 20A DP MCB 3 Nos. single phase bank each consisting of 1 No. 24 Hr Programmable timer , contactor and 8 nos. 10A/20A amp DPMCB, 10 KA with thermal magnetic protective releases as outgoings.
513Installation, testing and commissioning External lightingFeeder Pillars as mentioned in item No. 1 above fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof outdoor type double door including providing & making brick masonry foundation (including plastering etc.) of suitable size with all fixing accessories as required.
514Supply and Installation of 63A TPN RCCB ( 300 mA) in 4Way DB enclosure Near AC Outdoor Units
515Supply and Installation of 40A TPN RCCB ( 300 mA) in 4Way DB enclosure Near AC Outdoor Units
516Supply and Installation of Fully automatic DOL starters in MS Enclosurefor following motors with suitable C curve MCB , ON/OFF push buttons andon/off indicating lightswith MN type relay, A/M selector switch,Potential free contacts for local/remote operations contactors, single phase preventors for all motors, with selector switch and fusesoverload relay as required. 7.5 KW
517Supply and Installation of Fully automatic DOL starters in MS Enclosurefor following motors with suitable C curve MCB , ON/OFF push buttons andon/off indicating lightswith MN type relay, A/M selector switch,Potential free contacts for local/remote operations contactors, single phase preventors for all motors, with selector switch and fusesoverload relay as required. 2.25 KW
518Supply and Installation of Fully automatic DOL starters in MS Enclosurefor following motors with suitable C curve MCB , ON/OFF push buttons andon/off indicating lightswith MN type relay, A/M selector switch,Potential free contacts for local/remote operations contactors, single phase preventors for all motors, with selector switch and fusesoverload relay as required. 1.5 KW
519Earthing with copper . Earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.( with charcoal or coke and salt).
520Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( with charcoal or coke and salt).
521Supply and laying 25mmX5 MM GI strip at 0.50 meter below ground as strip earth electride including soldering etc as required
522Supply and laying 25mmX6 MM GI strip at 0.50 meter below ground as strip earth electride including soldering etc as required
523Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
524Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
525Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode
526Providing and fixing 25 mm X 5 mm Cu. strip in 40 mm dia G.I. pipe from earth electrode
527Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
528Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
529Providing and fixing earth bus of 50mmX 5mm copper strip on surface for connections etc. as required
530Prividing and Fixing of copper lightning conductor Finial made of 25mm dia 300 mm Long GI tube , having single prone on top with 85mm dia 6mm thick GI base plate including holes etc complete as required
531Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for vertical run)
532Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for horizontal)
533Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos.brass bolts, nuts check nuts and spring washers etc. complete as required.
534Providing and laying GItape, 32 mm x 6 mm thick from earth electrode directly in ground as required.
535Supply of following Light Fixtures6/7W Round Recessed mounted type LED Luminiare
536Supply of following Light Fixtures12W Round Recessed mounted type LED Luminiare
537Supply of following Light Fixtures18/20W Square Recessed mounted type LED Luminiare
538Supply of following Light Fixtures15/16W Round surface mounted type LED Luminiare
539Supply of following Light Fixtures10W LEDBulkhead fixture
540Supply of following Light FixturesRecessed Mounted LED Panel ( 600mmX600mm)-36W
541Supply of following Light Fixtures75/80W External Lighting Fixture
542Supply of following Light FixturesLED Battern ( 20W/22W)
543Installation , testing and commisioning of pre wires internal light fittings on all types complete with all accessories including connection with 1.5Sq, mm FR Wires
544Supply and fixingcircular/ hexagonal M.S. sheetceiling fanbox with clamp ofinternal dia 140mm, 73 mm height, 3mm thick rim toplid of 1.5mm thick M.S sheetlidss shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to be shape as per standard drawing with over all length as 80 cm
545Supplyandfixing of steptype electronic fanregulator on existing modularplateswitch box includingconnection but excluding modular plate etcas required.
546Installation, testing and commissioning following sizeceiling fans/bracket fan 3 blades to IS 374:2019 including wiring the down rods of standard length (up to 30 cm )with 1.5 sq.mmFR PVC insulated copper wire suitable for 230V 50Hz songle phase supply etc .complete as required.
547Supplying of 1200mm dia decorative type ceiling Fan
548Supplying of 300mm Exhaust Fan
549Installationofexhaustup to450mm sweepin the existing opening, including making the hole to suit the size of theabove fan, making good thedamage,connection, testing, commissioning etc. as required
550Providing, fixing, connecting, testing and commisssioning of zinc passivated box with moulded plate in recess or on surface moulded type with following including all necessary materials etc. as required.2 Pair telephone cord outlet (RJ-11)
551Providing, fixing, connecting, testing and commisssioning of zinc passivated box with moulded plate in recess or on surface moulded type with following including all necessary materials etc. as required.TV antina Socket outlet
552Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.20mm dia
553Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.25mm dia
554Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.32mm dia
555Supply and fixing 1 or 2 module ( 75mm X 75mm ) GI Box along with modular base and cover plate for modular switches in recess etc as required
556Supply and fixing of Computer terminal (RJ-45) outlet in existing box with modular plate
557Supplying and drawing co-axial TV cable RG-6 grade, copper conductor PE insulated, with PVC shield in the existing surface/ recessed PVC conduit as required.
558Supplying, drawing,of0.5mm dia (2 pair) FR PVC insulatedcopper conductor , unarmouredtelephone cable in existing surface/ recessed PVC conduit as required
559Supplying, drawing,of0.5mm dia (3 pair) FR PVC insulatedcopper conductor , unarmouredtelephone cable in existing surface/ recessed PVC conduit as required
560Supplying and Fixing in floor with all accessories , 2 mm thick steel sheet factory fabricated post galvanized floor recessed raceway of the following sizes300 mm widex 38 mm deep raceway
561Supplying and Fixing in floor with all accessories , 2 mm thick steel sheet factory fabricated post galvanized floor recessed raceway of the following sizes225 mm widex 38 mm deep raceway
562Supplying and Fixing in floor with all accessories , 2 mm thick steel sheet factory fabricated post galvanized floor recessed raceway of the following sizes100 mm wide x 38 mm deep raceway
563Providing and fixing 150 x 150 x 50 mm deep 1.6 mm thick GI sheetjunction box including providing 3 mm thick stainless steel coveras required
564Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.25mm dia
565Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.32mm dia
566Supplying and laying of following sizes FR PVC insulated single corecopperwire in existing conduit complete as required. 2x1.5 sq mm
567Supplying and laying of following sizes FR PVC insulated single corecopperwire in existing conduit complete as required.2x2.5 sq mm
568Supply, installation, testing and commissioning of plug-in type intelligent photoelectric smoke detectors including the cost of supplying base plate, mounting accessories etc. complete as as required.
569Supply, installation, testing and commissioning of plug-in type intelligent Multi Criteria detectors including the cost of supplying base plate, mounting accessories etc. complete as as required.
570Supplying, installation, testing and commissioning of analogue addressable rate of rise cum fixed temperature heat detector with built-in fault isolator as required.
571Supplying, installation, testing and commissioning of addressable resettable type manual call box (push type) with Fire written on the front side capable of giving individual address.The manual call box should haveanindicator,whichshould \"blink\"greenin case of normal condition and become steady Red in case of Operation
572Supplying, installation, testing and commissioning of response indicators with dual LED suitable for operation on 12/24 volts D.C., sheet steel / Polymer housing suitable for surface/recess mounting including making connections with wires complete in all respects
573Supply installation, testing and commissioning of Fault isolator Base / Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected
574Supplying, installation, testing and commissioning of hooter cum strobe with control module complete as required.
575Supply, installation, testing and commissioning of Four Zone \"X\" Loop (150 Detectors, 100 Devices) (Fire Alarm Capability: 1 Loop x 100/125/150 detectors with a minimum of 1 loop wall recess mounting microprocessor based analogue addressable Fire Control Panel expandable with minimum 80 character LCD display, 4 access levels, 1000 events historical logging, flash E-PROM, 240 volts ac power supply, automatic battery charger, 24V sealed lead-acid battery suitable operating the system for 30 minutes in emergency condition. The Panel shall be Integrated with the PA System and with suitable power amplifiers for hooter/strobes. The Panel shall provide either or all BACNET/RS485/LON protocols as required.
576Supply,installation,testingand commissioningof control relay module, 1 amp contact rating & 1 NO, 1 NC, all accessories required forcontrolling AHUs, dampers, pressurisation fans,Elevators, basement ventilation complete including accessories like power supply, relaysetcasrequired.
577Supply,installation,testingand commissioningof Two way communication Handset for Fireman complete as required
578Providing & Fixing of SS telephone Jack flush mountable,with screws,connections etc. as required.
579Providing, installing, testing and commissioning of totally enclosed Digital PA system operator consolewithTwowaycommunication(Talk Back System)with push to talk microphone, all call facility with suitable mixer complete with controller having inbuilt amplifer of suitable wattage , expandable with facility for recorded message and connectivity to third party DVD Music player, with emergency microphone, housed in free standing / wallmountedRackwithFront&backopenable, front with Glass, rack should be from reputed company. PA system should be coupled with the fire alarm system.
580Providing,fixing,testingandcommissioningof Ceiling mounted 6 watt speaker housed in sheet steel / Polymer housingincluding making connections with wires complete in all respects
581Supplying, installing, testing and commissioning of 2X1.0 SQMM IND. 1.1KV SPEAKER CABLE in existing conduit.
582Providing and fixing of self illuminated / auto glow \"EXIT\" signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 300 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site
583Providing,fixing,testingandcommissioningof wall mounted 6 watt speaker housed in sheet steel / Polymer housingincluding making connections with wires complete in all respect
584Wiring for Light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessedPVC conduit , with modular switch ,modular plate ,suitable GI box as requireda)Group - C
585Wiring for twin controlled light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessedPVC conduit , with 2 way modular switch ,modular plate ,suitable GI box etc as required.
586Wiring for group controlled ( Looped ) light/ceiling fan/exhaust fan/call bell point ( With out independent switch etc.) with 2x1.5 sq.mm PVC insulated stranded copper conductor cable alongwith 1 No. 1.5 sq.mm PVC insulated copper conductor cable for earthing in surface/recessed steel conduit as required.(Point shall be controlled / looped From existing point).a)Group - C
587Wiringwith2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVCconduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For primary 5A Socket , Primary MCB Point and Circuit Wiring)
588Wiringwith2 x 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVCconduit alongwith 1 No. 1.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For Secondary MCB Points and 5A Secondary Points)
589Wiringfor light / power plug point with2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC Medium Classconduit alongwith 1 No. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 16A Socket)
590Wiringfor light / power plug point with2 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVCconduit alongwith 1 No. 6sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For A/C Sockets)
591Wiringfor DB submainwith4 x 16 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVCconduit alongwith 2 No. 16sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
592Wiringfor DB submain with4 x 10 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVCconduit alongwith 2 No. 10sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
593Wiringfor DB submainwith2 x 10 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVCconduit alongwith 1 No. 10 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
594Wiringfor DB submainwith2 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVCconduit alongwith 1 No. 6 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
595Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch,connection,painting etc.as required.
596Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 6 pin 15 / 16 modular socket outlet and 15 / 16 amps modular switch,connection,painting etc.as required.
597Geyser point consisting of following :-- 1 No. 6 pin No 6/16A Modular Socket in 2 Module Boxwith modular Plate near Geyser- 1 No 6/16A Modular Switch in 2 Module Box with Modular plate near entry at switch board level- Wiring between Socket and Switch board with 3 Nos. 4.0 Sq. mm Cu Wire in conduit including connections at both ends
59820A, 3 pin socket outlet controlled by 20A 2P RCCB
599Supplyinginstallation, testing and commissioning of surface-recess mounting type three pole and neutral,prewired, sheetsteel, MCB distribution board 415 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCBdetachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as requiredTPN DB( Double door)A. TP&N D.B (Vertical TYPE)i) 1 No. 63 Amps 4P MCB Isolator + RCCBiv) 24 Nos. 6-32 Amps SP MCBs as outgoing
600Supplyinginstallation, testing and commissioning of surface-recess mounting type three pole and neutral,prewired, sheetsteel, MCB distribution board 415 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCBdetachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as requiredTPN DB( Double door)A. TP&N D.B (HORIZONTAL TYPE)i) 1 No. 40 Amps 4P MCB Isolatorii) 1 No. 40 Amps 2P RCCB -3Nosiii) 18 Nos. 6-32 Amps SP MCBs as outgoing
601Supplyinginstallation, testing and commissioning of surface-recess mounting type three pole and neutral,prewired, sheetsteel, MCB distribution board 415 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCBdetachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as requiredTPN DB( Double door)A. TP&N D.B (Vertical TYPE)i) 1 No. 63 Amps 4P MCB Isolator + RCCBii) 30 Nos. 6-32 Amps SP MCBs as outgoing
602Supplyinginstallation, testing and commissioning of surface-recess mounting type Siingle pole and neutral,prewired, sheetsteel, MCB distribution board 240 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCBdetachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as required SPN DB SP&N D.B (HORIZONTAL TYPE)i) 1 No. 40 Amps 2P RCCB -1Nosii) 10 Nos. 6-32 Amps SP MCBs as outgoing
603Supplyinginstallation, testing and commissioning of surface-recess mounting type Siingle pole and neutral,prewired, sheetsteel, MCB distribution board 240 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCBdetachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as required SPN DBSP&N D.B (HORIZONTAL TYPE)i) 1 No. 40 Amps 2P RCCB -1Nosii) 6 Nos. 6-32 Amps SP MCBs as outgoing
604Supplyinginstallation, testing and commissioning of surface-recess mounting type Siingle pole and neutral,prewired, sheetsteel, MCB distribution board 240 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCBdetachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as required SPN DBSP&N D.B (HORIZONTAL TYPE)-Double Doori) 1 No. 40 Amps 2P RCCB -1Nosii) 12 Nos. 6-32 Amps SP MCBs as outgoing
605Supply and installation of 2.5 kVA Inverterwith Maintenance free batteries and 30 Min Power Back up
606Constructing brick chamber with cover for cable entry of following sizes inside dimension) with cement concrete above work in cement mortar 1:5 (1 cement : 5 coarse sand) including making necessary notch for lighting the cover necessary excavation 10cm thick foundation concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside and outside plastering with cement mortar 1:3 (1 cement and 50% coarse sand) with floating coat of neat cement finish complete as per requirement.900 mm X900 mm X 1000mm Deep Man hole
607Constructing brick chamber with cover for cable entry of following sizes inside dimension) with cement concrete above work in cement mortar 1:5 (1 cement : 5 coarse sand) including making necessary notch for lighting the cover necessary excavation 10cm thick foundation concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside and outside plastering with cement mortar 1:3 (1 cement and 50% coarse sand) with floating coat of neat cement finish complete as per requirement.600 mm X600 mm X 750mm Deep Man hole
608Constructing brick chamber with cover for cable entry of following sizes inside dimension) with cement concrete above work in cement mortar 1:5 (1 cement : 5 coarse sand) including making necessary notch for lighting the cover necessary excavation 10cm thick foundation concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside and outside plastering with cement mortar 1:3 (1 cement and 50% coarse sand) with floating coat of neat cement finish complete as per requirement.450 mm X450mm X 600mm Deep Man hole
609Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia
610Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia
611Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.250 mm dia
612Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required63 mm dia (OD-63 mm & ID-51 mm nominal)
613Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required120 mm dia (OD-120 mm & ID-103 mm nominal)
614Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required160 mm dia (OD-160 mm & ID-135 mm nominal)
615Supply of 7.0 Mtr High Octagonal pole ( Hot Dip Galvanized) BOP-7030with top dia 70mm and bottom dia 130mm and made of 2mm thick base plate of size 200mmX200mmX12mm ( LXBXT) and with suitable size of foundation bolts and complete as required
6161.0 Mtr Arm suitable for above pole
617Erection Of metallicstreet light standard pole of length exceeding 6.5mtrs but not exceding 8.5mtrs inin cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregated 40mm nominal size) foundation with cement concerete collar of size 0.4m dia X 0.5m dia height to accomodate the looping type cable end box including excabation and refilling etc as required
618Supplyoffollowing sizes sizes of PVC insulated PVC sheathed aluminium conductor armoured 1.1 KV grade as as required.2C x 6 sq mm
619Supplyoffollowing sizes sizes of PVC insulated PVC sheathed aluminium conductor armoured 1.1 KV grade as as required.2C x 10 sq mm
620Supplyoffollowing sizes sizes of PVC insulated PVC sheathed aluminium conductor armoured 1.1 KV grade as as required.2C x 16 sq mm
621Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 25 sq. mm
622Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 25 sq. mm
623Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.Upto 25 sq. mm
624Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.2C x 6 sq mm
625Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.2C x 10 sq mm
626Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.2C x 16 sq mm
627Supplying and fixing of outdoor type junction box( IP 67 ) suitable to incoming and outgoing 3C-16 sq. mm Al Armoured Cable. The juction box shall also be suitable for 3 Nos. outgoing circuits each consisitng of 3 Nos. 2.5 sq mm copper wired wires
628Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc as required
629Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc as required ( but with charcoal/coke and salt )
630Supplying and fixing 50mm dia GI pipe on the pole for cable entry to junction box as required.
631Wiringwith2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVCconduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required
632Supply, installation, testing and commissioning of UL Listed 1.3 Megapixel CMOS Vandal-proof, Network Dome Camera (1280 × 960) resolution, 1/3” Progressive scan CMOS, [email protected], AGC ON. 0 Lux with IR on, IR cut filter with auto switch, IR range up to 30 mtrs, H.264 / MJPEG, Dual stream, motion detection, Bit rate 32 Kbps-16Mbps, 3D DNR, DWDR, 12 VDC ± 10%, PoE , IP66, K-10, with fixed lens between(2.5 - 12mm),size of lens shall be as per site requirement & mockup. ONVIF, SIP, NMS, Profile S supported, connectors complete as required in dome shape fixed type for mounting recessed in false ceiling or mounted on wall complete as required.
633Supply, installation, testing and commissioning of UL Listed 1.3 Megapixel CMOS, Vandal-proof, Network Bullet Camera,(1280x960)resolution, 1/3” Progressive scan CMOS, [email protected], AGC ON. 0 Lux with IR on, IR cut filter with auto switch,, H.264 / MPEG4 , Dual stream, Bit rate 32 Kbps-16Mbps, Standard IP66, PoE , with Fixed Lens between(2.5 - 12mm),size of lens shall be as per site requirement & mock-up ,IR range Up to 50 mtr, motion detection, withONVIF, SIP, NMS,Profile S supported, connectors complete as required IR Bullet fixedtype for mountingon wall or surface mounted with back box and adapter plate complete as required.
634Supply, installation, testing and commissioning of UL Listed 1.3 Megapixel CMOS, Vandal-proof, Network Bullet Camera,(1280x960)resolution, 1/3” Progressive scan CMOS, [email protected], AGC ON. 0 Lux with IR on, IR cut filter with auto switch,, H.264 / MPEG4 , Dual stream, Bit rate 32 Kbps-16Mbps, Standard IP66, PoE , with Fixed Lens between(2.5 - 12mm),size of lens shall be as per site requirement & mock-up ,IR range Up to 30 mtr, motion detection, withONVIF, SIP, NMS,Profile S supported, connectors complete as required IR Bullet fixedtype for mountingon wall or surface mounted with back box and adapter plate complete as required.
635Supply, installation, testing and commissioning of UL Listed 1.3 Megapixel CMOS Vandal-proof, Network Mini Dome Camera (1280 × 960) resolution, 1/3” Progressive scan CMOS, [email protected], AGC ON. 0 Lux with IR on, IR cut filter with auto switch, IR range up to 10 mtrs, H.264 / MJPEG, Dual stream, motion detection, Bit rate 32 Kbps-16Mbps, 3D DNR, DWDR, 12 VDC ± 10%, PoE , IP66, K-10, with fixed lens between(2.5 - 8mm),size of lens shall be as per site requirement & mockup. ONVIF, SIP, NMS, Profile S supported,for Lift Inside Camera
636Supply, Installation, testing and commissioning of the wireless Access point for lift camera( transmitter & reciever pair)
637Supply, installation, testing and commissioning of Professional Video management and recording software and hardware comprising 32Ch. NVR to record output of all cameras mentioned above in Item no 1,2,3 Third-party network cameras supported, H.264 Compression - Up to 5 Megapixels resolution recording, multiple Hard Disk 8 SATA with each having maximum storage capacity of 6 TB , as required for minimum 30 days recording required for recording when in 80% motion @ 720p 25 Frames per second(Real Time) or for recording when not in motion @720p 12.5 Frames per second, with RAID-5 Storage ,10/100/1000 MBps network interface with each NVR, 2 USB2.0,HTTP Networkable, backupby USB/DVDWR, required Client software included, 6 Nos Client licenses and required Camera licenses for each camera completeas required. All the components to be of same make as Camera.
638Supply,installation,testing and commissioning of32” CCTV colour LED screen including all accessories complete as required.
639Supply, installation, testing and commissioning ofLayer 3 switchHP/ Cisco make with 16 ports PoE managed, 10/100/1000 EB core switches to support all IP cameras & Access Control System , with 2 Fibre uplinks Portmodule only complete as required.
640Supply, installation, testing and commissioning ofLayer 2 switchHP/ Cisco make with 32 ports PoE managed, 10/100/1000 EB core switches to support all IP cameras & Access Control System , with 2 Fibre uplinks Portmodule only complete as required.
641Supplying and installation of 19\" 42U APW President Rack with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate systems equipment and accessories as mentioned in the BOQ above and including all connections and terminations as required
642Supply and Laying of Cat-6 Cable in existing conduits for Cameras
643Supply and Laying of 3C-2.5 Sq. mm unarmouredcopper Power Cable in existing conduits for Cameras power supply
644Supply and Laying of 3C-1.5 Sq. mm unarmouredcopper Power Cable in existing conduits for Cameras power supply
645Supply , Installation , testing and commisioning of 2.0kVA UPS ( 1 Phase input and 1 Phase output) with 15 Minutes back up complete with batteries etc.
646Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.20mm dia
647Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.25mm dia
648Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.32mm dia
649Supply, installation, testing and commissioning of 750 KVA, at 0.8 P.F. (lagging), aircooled radiator type diesel engine alternator set mounted on common base frame complete with accessories asper specification and layout, drawing with battery charger, battery andbattery rack residential silencer, stainless steel bellows, 990 Ltrs. day fuel tank, spring loaded GERB cush pads, logic control panel, governor etc including Accoustic Enclosure suitable for outdoor installation complete as required.
650Supply, installation, testing and commissioning of 500 KVA, at 0.8 P.F. (lagging), aircooled radiator type diesel engine alternator set mounted on common base frame complete with accessories asper specification and layout, drawing with battery charger, battery andbattery rack residential silencer, stainless steel bellows, 990 Ltrs. day fuel tank, spring loaded GERB cush pads, logic control panel, governor etc including Accoustic Enclosure suitable for outdoor installation complete as required.
651Supply, laying of following sizes of MS Piping for Exhaust including providing suitable bends, reducers & supporting arrangement at suitable intervals including insulation on entire length of exhaust pipe with 50mm thick Rockwool insulation & painting etc. as required.250mm (NB) MS ERW pipe
652Supply, installation, testing and commissioning of 180 AH capacity 24 volts DC hermetically sealed maintenance free batteries duly charged including battery charger unit with provisions of Boost Charging, and Float charging. Suitable for 240 V, including DC DB single phase AC 50 Hz as per specifications
653IP Video Desktop Phone 16 lines with up to 16 SIP accountsBuilt-in 2 megapixel camera for video calling with privacy shutter Runs on the Android 7.x operating system Built-in Bluetooth for syncing with mobile devices and connecting Bluetooth headsets Dual-switched auto-sensing 10/100/1000Mbps network ports Integrated dualband Wi-Fi (2.4GHz & 5GHz) Built-in PoE/PoE+ for power and network connections Dual-mic HD speakerphone with advanced echo cancellation & excellent double-talk performance for any scenario 64-bit quad-core processor, 2GB RAM, and 16GB Flash 8’’ (1280x800) capacitive 10-point touch screen IPS LCD Peripherals include HDMI-in/out, USB, Micro SD, headset jack, EHS (Plantronics headsets) 7-way HD audio conferencing & 3-way 1080p 30fps HD video capability
654Supply, Installation,Testing & Commissioning of Single 0.7\" DLP Technology by TI Dual-lamp engine design for a brighter image and operational reliability should one lamp go down 6700 ANSI Lumens and 3000:1 contrast ratio Native XGA resolution with a maxium UXGA resolution DLP® and BrilliantColor™ technologies for detailed image quality Variety of connectivity options including: DVI, S-video, composite, component Enhanced color and display adjustments PC 3D compatibility with DLP® Link™ Power lens shift for easy adjustment and movement Seven (7) interchangeable lens options for a variety of projection needs Interchangeable color wheels for diverse applications and installation requirements One touch quick release lens button Built-in 12V trigger for convenient control of projector screen Network-ready for integration and system administration via RJ45
655Supply, Installation,Testing & Commissioning of Motorised front Projection Screen, wide(8ft) X hight (6ft) with Remote Control
656Supply, Installation,Testing & Commissioning of Ceilingspeaker 2-waybuilt-in loudspeaker,Power rated-40W/20W/15W/8ohm,“the reference loudspeaker”. It can be used with a standard Hifi amplifier and provides you with a Pro HiFi sound. The loudspeaker has an enforced 6 ½” woofer and 1” tweeter.suitable for the distribution of Back Ground Music.The housingis made of high quality ABS.SPL 1 watt/1 m-92db,SPL Max peak-106db,Frequency Range-60Hz to 20Hz Dispersion @ 1 kH-180Deg,@4KHz-80Deg,@8KHz-45Deg,IP-54 Rated Make- Bose/Martin-Audio/D&B
657Supply Installation testing and comisioning of 500W RMS Dual Channel Class-D Digital Power Amplifier with Switch power technology for power electricity saving, Separate PFC Design for highest reliability, Separate Power Supply System. Amplifier shall have Following Features: 240W RMS per Channel, Amplifier Output 100V, Supply input AC 220 +/- 10% - 50/60Hz, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD <0.1%, Frequency Response 40Hz - 20kHz, AC & DC Fuse, SNR >89dB.
658Supply of 10-12 Channel Digital Mixer with at least 8x Combo XLR-¼\" inputs, 1x Stereo inputs, 2 x Aux sends, Balanced stereo outputs, dedicated headphone output, USB A and B type connectors for WAV/MP3 files playback and PC connection, Protective magnetic cover. Shall also offer built-in Advanced digital audio processing with Studio-quality effects, Independent effects per channel, Master output EQ, Tap-tempo delay, Chromatic tuner and recallable scenes, illuminated LED display and controls, Switchable phantom power.
659Wireless Headset microphone : Frequency response :80Hz - 18kHz (Mic) Microphone type: Condenser; Polar Pattern : Cardioid; Max SPL : 150dB; THD : <0.9%; Signal to noise ratio : > 110dB; RF Output power : 30mW.
660Wireless Handheld microphone: Frequency response :80Hz - 18kHz (Mic); Maximum SPL : 154 dB; Bandwidth: 42MHz; Total harmonic distortion (THD) : < 0.9%; Signal to noise ratio : > 110 dB; 8 hours of operation; 12 presets; Microphone type: Dynamic.
661Gooseneck Microphone: Cardioid polar pattern; Frequency Response: 50 Hz to 20 kHz; Impedance <100 Ohms; Max Sound Pressure level: 130 dB; RF shielding against intermodulation from wireless devices with Base stand: a table stand with microphone modes like Toggle on/off, Push to mute, Push to talk.
662Supply Installation, Testing and Commissioning of Digital Lectern System with complete inbuit audio system andwired Goosecnec Microphone.
663Supply and laying of speaker cable
664Supply and laying ofHDMI & VGA Wall plate.
665Supply and laying of10Mtr HDMI Cable.
666Supply and laying of10Mtr VGA Cable.
667Supply and laying of 5Mtr HDMI Patch Cable.
668Supply and laying of5Mtr VGA Patch Cable.
669Add GST @12%
670Add Labour Cess @ 1%

AI Tender Summary

OUR REF NO 30490140
AUTHORITY Government Departments
TENDER VALUE 44.23 Crore
LAST DATE 19-01-2022
Authority
Authority Name Jharkhand Industrial Infrastructure Development Corporation Limited
Work Description Construction Of World Trade Centre At Core Capital Area At Site1 Hec Area Ranchi Jharkhand Construction Of World Trade Centre At Core Capital Area At Site1 Hec Area Ranchi Jharkhand
Basic Detail
Tender No JIIDCO/06/SBD/WTC/2021-22
Bidding Type Tender
Location
City
State Jharkhand
Key Dates
Publish Date 29 Dec 2021
Submission Date 19 Jan 2022
Open Date 20 Jan 2022
Finance
Tender Value 44.23 Crore
Tender Fee 10000
EMD 44.24 Lakhs
Exemption Not Available
Document List
29aa88f6-615c-430a-9385-9f81605c77bc.html
BOQ_73750.xls
sbd.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 29, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 19, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 20, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

29aa88f6-615c-430a-9385-9f81605c77bc.html

xls

BOQ_73750.xls

pdf

sbd.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender