| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-01-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-01-2022 |
| Sl. No. | Item Description |
| 1 | Taking down carefully aluminium/copper point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc complete all as required and keeping serviceable light fittings in safe custody for reuse in the work as directed. |
| 2 | M & L for point wiring ,wire drawn through PVC casing capping of adequate size but not less than 20mm in width, 1.2mm thick with all fittings andwith 1.5 sqmm PVCFRLSinsulated (red for phase and black for neutral) sheathed , multi stranded copper conductor 1100 volt grade cable and 1.5 sqmm green in colour PVC insulated multy stranded copper conductor cable for earth continuity connected to common earth bus incl factory made metal sheet terminal box modularflush type of thickness not less than 3.00mm( required as per site condition),for mounting fittings such as switches, sockets, fan regulators, bell push etc and including all other fixing accessories complete all as specified and directed for one light point/fan point controlled by one way modular switch. Note:- Modular Box PVC/ Metalandcover plates areincluded in the quoted rate |
| 3 | All as per item No 2.00 above but one fan point controlled by one 5 Amps one waymodular switch complete as specified and directed. |
| 4 | All as per item No2.00 above but onecall bellpoint controlled by push bottom complete as specified and directed.. |
| 5 | All as per item No 2.00 above but one 5/6 Ampsocket controlled by one switch in Independent board. |
| 6 | All as per item No2.00above but one 5/6 Amp Socket controlled by one switch on same board. |
| 7 | All as per item No2.00 above but one light point controlled by two way switches complete as specified and directed. |
| 8 | All as per item No 2.00above butone 3 pin, 5/15 Amps switch socket outlet on independent but using PVC FRLS insulated, unsheathed stranded copper conductor cable of size 4 Sqmm and 1.5sqmm for earth continuity conductor complete as specified and directed. |
| 9 | M & L for point wiring ,wire drawn throughin and incl PVCconcealed conduit andwith 1.5 sqmm PVCFRLSinsulated(red for phase and black for neutral) sheathed , multi stranded copper conductor 1100 volt grade cable and 1.5 sqmm green in colour PVC insulated multy stranded copper conductor cable for earth continuity connected to common earth bus incl factory made metal sheet terminal box modularflush type of thickness not less than 3.00mm ( required as per site condition),for mounting fittings such as switches, sockets, fan regulators, bell push etc and including all other fixing accessories complete all as specified and directed for one light point/fan point controlled by one way modular switch. Note:-Modular Box PVC/ Metalandcover plates areincluded in the quoted rate |
| 10 | All as per item No 9.00 above but one fan point controlled by one 5 Ampsone waymodular switch complete as specified and directed. |
| 11 | All as per item No 9.00 above but onecall bellpoint controlled by push bottom complete as specified and directed.. |
| 12 | All as per item No 9 above but one 5 /6 Ampsocket controlled by one switch Independent board complete as specified and directed. |
| 13 | All as per item No9 above but one 5/6 Ampsocket controlled by one switch on same board complete as specified and directed.. |
| 14 | All as per item No 9.00 above but one light point controlled by twoway switches complete as specified and directed. |
| 15 | All as per item No 9.00above butone 3 Pin, 5/15 Amps switch socket out let independent but using PVC FRLS insulated, unsheathed stranded copper conductor cable of size 4 Sqmm and 1.5sqmm for earth continuity conductor complete as specified and directed. |
| 16 | S&F modular switch piano flushtype single pole one way 5/6 Amps incl necessary connections complete as specified and directed. |
| 17 | S&F modular switch piano flushtype single pole two way 5/6Amps incl necessary connections complete as specified and directed. |
| 18 | S&F socket out let 5/ 6 Amps 5 pin modularflush typeincl necessary connections complete as specified and directed. |
| 19 | S&F modular bell push switchflushtype single pole one way 5/6 amps incl necessary connections complete as specified and directed. |
| 20 | S&Fmodular switch piano flushtype single pole one way 15/16 Ampsincl necessary connections complete as specified and directed. |
| 21 | S&F modular socket 2 in 1, 5 pin6/16 Ampsflush typeincl necessary connections complete as specified and directed. |
| 22 | S&F modular rotating step type electronic fan regulator, 120w/280volts incl necessary connections complete as specified and directed. |
| 23 | S&F multi music call bellincl necessary connections complete as specified and directed. |
| 24 | S&FDingdong call bellincl necessary connections complete as specified and directed. |
| 25 | S&F ceiling rose, surface type, Bakelite, 65x50mm two to three terminals complete all as specified and as directed. |
| 26 | S&F in repairs lamp holder, PVC/ Polycarbonate type with back plate for batten fittings complete as specified and directed. . |
| 27 | S&F in replacement LEDbulb 0.5 W R-Y-B, colour should be decided by Engr-in-Charge complete as specified and directed. |
| 28 | S&F in replacement LED 7 W Bulb type complete as specified and directed. |
| 29 | S&F in repairs decorative Ultra Slim linear LED tube light fitting with extruded Polycarbonate environmental friendly energy efficient of capacity20W 6000Ketc, complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size complete as specified and directed. |
| 30 | S&F in repairs decorative Ultra Slim linear LED tube light fittingfixture with extruded Polycarbonate environmental friendly energy efficient of capacity10 W 6000Ketc, complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size complete as specified and directed. |
| 31 | S&Fin repairs energy efficient 36 W recess / ceiling mounted LED luminary suitable for 2\"x2\" grid with profiled diffuser including lamp, electronic control driver 36 watts, AC 230 Volts 50 Hz supply single phase including connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting and fixing to ceiling complete all as directed. |
| 32 | S&F in repairs 15 W recess typeLEDdecorative ultra slim Squarelighting fixture with co extruded polycarbonate body, environmental friendly, energy efficientand makingconnections with twin twisted unsheathed PVC copper cable of suitable sizecomplete as specified and directed. |
| 33 | S&F in repairs 9 W recess typeLEDdecorative ultra slim Squarelighting fixture with co extruded polycarbonate body, environmental friendly, energy efficientand makingconnections with twin twisted unsheathed PVC copper cable of suitable size complete as specified and directed. |
| 34 | S&F in repairs energy efficient wallmounted LED luminary30watts, AC 230 Volts 50 Hz supply single phase including connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting and fixing to ceiling complete all as directed. |
| 35 | S&F in replacementrechargeable 12 W LED light with frosted PC cover and pull chord, rechargeable Li-ion battery of 3.7 volts, 2000 mAh capacity environmental friendly energy efficient complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as specified and directed. |
| 36 | S&F in repairs LEDmirror lightfittings 12Watt integral polycarbonate LED channel with white acrylic cover complete as specified and directed. |
| 37 | S&F in replacement LED building securitylight fittings 36 Wattpressure dia cast housing with epoxy power coated dark graphite grey colour finish, polycarbonate cover with indivisual LED lenses with IP 65 protection complete as specified and directed. |
| 38 | S&F in repairs bracketmade of GI material of GI pipe of size 32mm dia and 60 CM long including two no of GI clamp fixed on wallwith GI flash nut of suitable size complete all as directed |
| 39 | Taking down of unserviceable ceilingfan / Wall mounted fan/Exhaust fanof any size and sweep and refixingthe same in existingplace with serviceable conditioncompleteall as specified and as directed. Note : Cost of spare parts shall be included in the quoted rate |
| 40 | Taking down old unserviceable aluminium sub main wiring any size complete with PVC conduit/ casing capping and removing materials from site and making good disturbed surfaces of walls, etc complete as specified and directed. |
| 41 | M&L for sub main wiring with 2 runs of 2.5 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping /Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 2.5 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed.(Note : (i) PVC casing capping/ Conduitand its accessories measured and paid separately (ii) Two runs of cables and one run of earth wire shall be measured as one unit length) |
| 42 | M&L for sub main wiring with 2 runs of 10 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping /Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 10 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed.(Note : (i) PVC casing capping/ Conduitand its accessories measured and paid separately (ii) Two runs of cables and one run of earth wire shall be measured as one unit length ) |
| 43 | M&L for sub main wiring with 2 runs of 6 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping /Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 6 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed.(Note : (i) PVC casing capping/ Conduitand its accessories measured and paid separately (ii) Two runs of cables and one run of earth wire shall be measured as one unit length ) |
| 44 | S&F for sub main wiring with 2 runs of single core, 4 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping /Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 4.00 Sqmm PVC insulated, unsheathed, single core, multistranded,, copper conductor as earth continuity wire complete as specified and directed. (Note : (i) PVC casing capping and its accessories measured and paid separately (ii) Two runs of cable and one run of earth wire shall be measured as one run length) |
| 45 | M&L for cutting of grove channel of wall for sub main wiring and preparing surface to make good complete all as specified and directed. |
| 46 | S&F in repairs vertical MCCB DB TPN 4 wayIP-43 made of sheet steel phosphatised, powder painted with bus bar400A, neutral link, earth bar and Din rail ,415 Volts with double door complete all as specified and as directed Note : DB shall be concealed on wall including making good to the disturbed surface |
| 47 | S&F in repairs MCCB 4 Pole, 415Volts breaking capacity 25 KA,\"C\" series of rating 100 Amps including testing complete all as specified and as directed |
| 48 | S&F in repairs MCCB 4 Pole, 415Volts breaking capacity 25 KA,\"C\" series of rating 63 Amps including testing complete all as specified and as directed |
| 49 | S&F in replacement vertical type of MCB TPN DB4 wayIP-43 made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and Din rail ,415 Volts with double door complete all as specified and as directedNote : DB shall be concealed on wall including making good to the disturbed surface |
| 50 | S&F in replacement MCB SPN DB 12 way IP-43made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and din rail ,230 Volts with double door complete all as specified and as directedNote : DB shall be concealed on wall including making good to the disturbed surface |
| 51 | S&F in replacement MCB SPN DB8 way IP-43made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and din rail ,230 Volts with double door complete all as specified and as directedNote : DB shall be concealed on wall including making good to the disturbed surface |
| 52 | S&F in replacement MCB SPNDB4 way IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,230 Volts with double door complete all as specified and as directedNote : DB shall be concealed on wall including making good to the disturbed surface |
| 53 | S&F in replacement MCB TPN240 Volts, \"C\" series, breaking capacity 10 KA of rating40 Amps complete all as specified and as directed |
| 54 | S&F in replacement MCB TPN240 Volts, \"C\" series, breaking capacity 10 KA of rating63 Amps complete all as specified and as directed |
| 55 | S&F in replacement MCB TP240 Volts, \"C\" series, breaking capacity 10 KA of rating40 Amps complete all as specified and as directed |
| 56 | S&F in replacement MCB TP240 Volts, \"C\" series, breaking capacity 10 KA of rating63 Amps complete all as specified and as directed |
| 57 | S&F in replacement MCB SPN 240 Volts, \"C\" series, breaking capacity 10 KA of rating 40 Amps complete all as specified and as directed |
| 58 | S&F in replacement MCB SPN 240 Volts, \"C\" series, breaking capacity 10 KA of rating 63 Amps complete all as specified and as directed |
| 59 | S&F in replacement MCB SP 6-32 Amps complete all as specified and as directed |
| 60 | S&F in replacement MCB SP 40Amps complete all as specified and as directed |
| 61 | S&F in replacement MCB SP 63Amps complete all as specified and as directed |
| 62 | M&L for replacement of earthingwith galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 25 mm x 3 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe \"light grade\" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1,pre-cast reinforced cover with steel round bar 8 mmRCC 1:1.5:3 cover slab of size 450x 450 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testingcomplete all as specified and as directed |
| 63 | Taking down of unserviceable conventional type tube light fitting of T8type 36/40 Watt and rewiring of fitting and supply and fixing of LED tube rod PC type of capacity 18 watt andrefixingthe same existingplace completeall as specified and as directed |
| 64 | Taking down of unserviceable conventional typetube light fitting18 Watt and rewiring of fitting and supply and fixing of LED tuberod PC type of capacity 10 watt andrefixingthe same existingplace completeall as specified and as directed |
| 65 | Taking down of unserviceable conventional type tube light fitting of T5 of 36 watt type and supply and fixing of LED tube light fitting of capacity 20 wattthe same placecompleteall as specified and as directed. |
| 66 | Taking down of unserviceable conventional tube light fittingof 20 wattsupply and fixingof LED light fitting of capacity 10watt the same placecompleteall as specified and as directed |
| 67 | Taking down of unserviceable conventional tube light fittingof 18 watt supply and fixingof LED light fitting of capacity 5 watt the same placecompleteall as specified and as directed. |
| 68 | S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single poleMCB 32 Amps complete all as specified and as directed |
| 69 | S&F in replacement of foot light 3 W outdoor type completeall as specified and as directed |
| 70 | Taking down of unserviceable 2X18watt pin type CFL recess mounted Square light fittingand supply and fixing of 15 wattLED recess mounted square light fitting square type of existing place completeall as specified and as directed . |
| 71 | Taking down of unserviceable Tube light batten 36/40 watt light fittingand supply and fixing of suitable of 18/20 watt LEDbatten light fitting with wiring of existing placecompleteall as specified and as directed |
| 72 | Taking down old conventional type CFL Lamp of 25 watt and Supply and fixing LED 9 W Bulb type complete all as specified and as directed |
| 73 | Taking down of unserviceable conventional surface type 36 watt light fitting and supply and fixing recessmounted slim type LED 12Watt down lighter with white powder coated aluminium housing with integrated electronic driver of existing placecompleteall as specified and as directed |
| 74 | Taking down of unserviceable conventional surface type 72 watt light fitting and supply and fixing surface mounted energy efficient recess / Ceiling mounted LED luminary suitable for 2\"x2\" grid with profiled diffuser including lamp, electronic control driver 36 watts, AC 230 Volts 50 HzLED 40 Watt down lighter with white powder coated aluminium housing with integrated electronic driver of existing placecompleteall as specified and as directed |
| 75 | Taking down of unserviceable conventional36 watt surface type light fitting and supply and fixing 18 WLED surface typedecorative ultra slim round lighting fixture with co extruded polycarbonate body, environmental friendly, energy efficientand makingconnections with twin twisted unsheathed PVC copper cable of suitable size complete as directed |
| 76 | Taking down of unserviceable conventional 24 surface type light fitting and supply and fixing 12 WLED surface type decorative ultra slim round lighting fixture with co extruded polycarbonate body, environmental friendly, energy efficientand makingconnections with twin twisted unsheathed PVC copper cable of suitable size complete as directed. |
| 77 | Taking down of unserviceable conventional36 watt recess type light fitting and supply and fixing 18 W recess typeLEDdecorative ultra slim Squarelighting fixture with co extruded polycarbonate body, environmental friendly, energy efficientand makingconnections with twin twisted unsheathed PVC copper cable of suitable size complete as directed |
| 78 | Taking down of unserviceable conventional18 watt recess type light fitting and supply and fixing 9 WLED recess type decorative ultra slim round lighting fixture with co extruded polycarbonate body, environmental friendly, energy efficientand makingconnections with twin twisted unsheathed PVC copper cable of suitable size complete as directed |
| 79 | Taking down of unserviceable conventional type 18 watt wall light fittingand supply and fixing 7 WLEDdecorative ultra slim wall light fittingfixture with co extruded polycarbonate body, environmental friendly, energy efficientand makingconnections with twin twisted unsheathed PVC copper cable of suitable size complete as directed . |
| 80 | Taking down of unserviceable conventional type 150 watt wall focus light and supply and fixing 18 WLED narrowbeam light making wall light fittingfixture with co extruded polycarbonate body, environmental friendly, energy efficientand makingconnections with twin twisted unsheathed PVC copper cable of suitable size complete as directed. |
| 81 | Taking down carefully old ceiling fan with necessary fitting andsupply & replacement Energy efficientceiling fan 1400 mm sweep single phase 230 / 240 volts AC with externaldistance speed control with necessary fitting and connecting with cable from ceiling rose or connector to fan includingall as specified and directed |
| 82 | Taking down of unserviceable conventional focus light fittingof 18 watt and supply and fixingof LED focuslight fitting of capacity 3 Wcompleteall as specified and as directed |
| 83 | Taking down of unserviceable conventional surface type light fitting and supply and fixing24 WLED Horizontal gear box Track lightsame placecompleteall as specified and as directed |
| 84 | Taking down of unserviceable conventionaltype spot light fitting and supply and fixing 30W LEDround type same placecompleteall as specified and as directed |
| 85 | Taking down of unserviceable strip light fitting and supply and fixing LED Strip light 14.4 watt 220 Volt RGB (WW,WH) Pink coloured completeall as specified and as directed |
| 86 | Taking down of unserviceable strip light fitting and supply and fixing neon LED Strip light220 Volt RGBcoloured completeall as specified and as directed |
| 87 | Taking down of unserviceable connector and supply and fixing neon LED Stripconnector220 Volt completeall as specified and as directed . |
| 88 | Taking down of unserviceable connector and supply and fixingLED Stripconnector220 Volt for RGB coloured completeall as specified and as directed |
| 89 | Taking down of unserviceable 5/6 Amp box type Switch Socket combination and supply and fixing of new 5/6 Amps box type switch socket combination at thesame placecompleteall as specified and as directed. |
| 90 | Taking down of unserviceable 15/16 Amp box type Switch Socket combination and supply and fixing of new 15/16 Amps box type switch socket combination at thesame placecompleteall as specified and as directed |
| 91 | Taking down of unserviceable ceiling rose and supply and fixing of new ceiling rose at thesame placecompleteall as specified and as directed |
| 92 | Taking down carefully old ceiling fan with necessary fittingandsupply & replacementEnergy efficient ceiling fan 1200 mm sweep single phase 230 / 240 volts AC with necessary fitting and connecting with cable from ceiling rose or connector to fan i all as specified and directed. |
| 93 | Taking down of unserviceable 5/15 Amp Switch Socket and supply and fixing of new 5/15 Amps switch socket combination at thesame placecompleteall as specified and as directed. |
| 94 | Taking down of unserviceable 5/6 Amp 5 pin Switch socket combination and supply and fixing of new 5/6 Amps 5 pin switch socket combination at thesame placecompleteall as specified and as directed. |
| 95 | Taking down of unserviceable 5/6 Amp 5 pinsocketand supply and fixing of new 5 Amps 5 pin socketat thesame placecompleteall as specified and as directed. |
| 96 | Taking down of unserviceable 5 Amp two way piano switchand supply and fixing of new switch piano, flush type ,two way 5 Amp, 230 Voltsat thesame placecompleteall as specified and as directed |
| 97 | Taking down of unserviceable 5 Amp single pole piano switchand supply and fixing of newpiano switch , flush type , single pole , one way 5 Amp, 230 Voltsat thesame placecompleteall as specified and as directed. |
| 98 | Taking down of unserviceable 5 Amp bell push switchsupply and fixing of new switch piano, flush type , bell push switch 5 Amp, 230 Voltsat thesame placecompleteall as specified and as directed. |
| 99 | Taking down of unserviceable electronic type fan regulator andsupply and fixing of new electronic type two modulefan regulator of230 Voltsat thesame placecompleteall as specified and as directed. |
| 100 | Taking down of unserviceable electronic type fan regulator andsupply and fixing of new electronicswitch typefan regulator of230 Voltsat thesame placecompleteall as specified and as directed. |
| 101 | Taking down of unserviceable resistancetype fan regulator andsupply and fixing of new resistance type fan regulator of230 Voltsat thesame placecompleteall as specified and as directed. |
| 102 | Taking down of unserviceable 5/15 Amp modularSocket and supply and fixing of new 5/15 Amps Modular socketat thesame placecompleteall as specified and as directed. |
| 103 | Taking down of unserviceable 5/6 Amp 5 pin modular socket and supply and fixing of new 5 Amps 5 pin modular socket at thesame placecompleteall as specified and as directed. |
| 104 | Taking down carefully old exhaust fan of size 450 mm sweep andS&F Heavy duty Exhaust fan continuous duty with louvers, double ball bearing. silent operation, rust proof body and blades with fixing arrangements of size 450 mm sweep, 1400 rpm, 240V complete all as specified and as directedNote : OldFandeposited to E/M Store yard. |
| 105 | Taking down of unserviceable 15/16 Amp single pole modular piano switch and supply and fixing of newmodular piano switch, flush type, single pole, one way 15/16 Amp, 230 Voltsat thesame placecompleteall as specified and as directed |
| 106 | Taking down of unserviceable 5 Amp single pole modular piano switchand supply and fixing of newmodular piano switch, flush type, single pole, one way 5/6 Amp, 230 Voltsat thesame placecompleteall as specified and as directed. |
| 107 | Taking down of unserviceable 5 Amp double pole modular piano switchand supply and fixing of newmodular piano switch, flush type, double pole, one way 5/6 Amp, 230 Voltsat thesame placecompleteall as specified and as directed. |
| 108 | Taking down of unserviceable 5 Amp modular bell push switchand supply and fixing of new modularpiano switch , flush type , bell push switch 5 Amp, 230 Voltsat thesame placecompleteall as specified and as directed. |
| 109 | Taking down carefully old ceiling fan with necessary fittingandS&F Energy efficientceiling fan 1400mm sweep single phase 230 / 240 volts AC with necessary fitting and connecting with cable from ceiling rose or connector to fanall as specified and directed. Note : OldFan deposited to E/M Store yard. |
| 110 | Taking down of unserviceable modular electronic type fan regulator andsupply and fixing of new modular electronic type two modulefan regulator of230 Voltsat thesame placecompleteall as specified and as directed. |
| 111 | Taking down of unserviceable multimusictype call belland Supply and fixing including connection ofmulti music call bellat thesame placecompleteall as specified and as directed. |
| 112 | Taking down of unserviceable dingdongtype call belland Supply and fixing including connection ofdingdong call bellat thesame placecompleteall as specified and as directed. |
| 113 | Taking down carefully old ceiling fan with necessary fitting and making good to damaged surface of wall/ceiling to match existing finish andS&F Fresh air fan continuous duty with louvers, with fixing arrangements of size 250 mm sweep, 1400 rpm, 240Vcomplete all as specified and as directedNote : OldFandeposited to E/ M Store yard. |
| 114 | Taking down of unserviceable Lamp holder, PVC/ Polycarbonate type with back plate for batten fittings. and supply and fixing of new Lamp holder, PVC/ Polycarbonate type with back plate for batten fittings of230 Voltsat thesame placecompleteall as specified and as directed. |
| 115 | Taking down of unserviceable capacitor 2.5 mfd from celling/ wall mounted/Exhaust fanand supply and fixing of new capacitor 2.5 mfd of celling/ wall mounted fanof230 Voltsat thesame placecompleteall as specified and as directed. |
| 116 | Taking down of unserviceable capacitor 3.15 mfd from celling/ wall mounted/Exhaust fanand supply and fixing of new capacitor 3.15mfd of celling/ wall mounted fanof230 Voltsat thesame placecompleteall as specified and as directed |
| 117 | Taking down of unserviceable Metalsunk box of size 10X12 inchand supply and fixing of new Metalbox of size 10X12 inch and fitting of existing serviceable switch ,socket, regulator etc at thesame placecomplete all as specified and as directed. Note :- PCC and all connected itemsfor making good to disturbed surface are included in the quoted rate |
| 118 | Taking down of unserviceable Metal sunkbox of size 10X8 inchand supply and fixing of new PVC box of size 10X8 inch and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed Note :- PCC and all connected itemsfor making good to disturbed surface are included in the quoted rate |
| 119 | Taking down of unserviceable Metalsunk box of size 6X8 inchand supply and fixing of new PVC box of size 6X8 inch and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed Note :- PCC and all connected itemsfor make in good are including. |
| 120 | Taking down of unserviceable Metal sunkbox of size 4X4 inchand supply and fixing of new PVC box of size 6X8 inch and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed Note :- PCC and all connected itemsfor making good to disturbed surface are included in the quoted rate |
| 121 | Taking down of unserviceable PVC box of size 10X12 inchand supply and fixing of new Metalbox of size 10X12 inch and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 122 | Taking down of unserviceable PVCbox of size 10X8 inchand supply and fixing of new PVC box of size 10X8 inch and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 123 | Taking down of unserviceable PVCbox of size 6X8 inchand supply and fixing of new PVC box of size 6X8 inch and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 124 | Taking down of unserviceable PVCbox of size 4X4 inchand supply and fixing of new PVC box of size 4X4 inch and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 125 | Taking down of unserviceable Modular PVC Box with white cover plate and frame 1/2 module supply and fixing of new Modular white cover plate with frame 1/2 module and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 126 | Taking down of unserviceable ModularPVC Box with white cover plate andframe 3 module supply and fixing of new Modular white cover plate with frame 3 module and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 127 | Taking down of unserviceable Modular PVC Box with white cover plate andframe4module supply and fixing of new Modular PVC Box withwhite cover plate with frame 4 module and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 128 | Taking down of unserviceable Modular PVC Box with white cover plate andframe6 module supply and fixing of new Modular pvc box white cover plate with frame6module and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 129 | Taking down of unserviceable Modular PVC Box with white cover plate andframe 8 module supply and fixing of new Modular white cover plate with frame 8 module and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 130 | Taking down of unserviceable Modular PVC Box with white cover plate andframe 12 module supply and fixing of new Modular box white cover plate with frame 12module and fitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed. |
| 131 | Taking down of unserviceable laminated sheet top cover of size 10X12 inchand supply and fixing of new 3mm thick plastic laminated sheet top cover or PVC termination board and refitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed |
| 132 | Taking down of unserviceable laminated sheet top cover of size 8X10 inchand supply and fixing of new 3mm thick plastic laminated sheet top cover or PVC termination board and refitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed. |
| 133 | Taking down carefully old unserviceable geyser 15 Ltr capacity with necessary fitting and making good to damaged surface of wall to match existing finish , depositing to MES store and Supply and fix energy efficient new 15liters capacity electrical geyser white/half white, copper container inner tank with fibre reinforced body (FRB) puff insulation for both inner tank & for hot outlet copper connection pipe with all in built in safety accessories like thermostat/automatic thermal cut out with ON /OFF /CUT out indicators all pre-wired and additional safety accessories like pressure release valve/pressure reducing valve, non return valve, rate shall be including for new PVC heavy duty hot & cold wired pipe of length 1.0 meter with brass ferrule fitting for HOT and COLD water connections fixed in same or new location as ordered/required as per manufacturers instruction with suitable size nuts & bolts, making necessary connection & testing on completion complete all as directed. |
| 134 | Taking down of unserviceable laminated sheet top cover of size 6X8inchand supply and fixing of new 3mm thick plastic laminated sheet top cover or PVC termination board and refitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed. |
| 135 | Taking down of unserviceable laminated sheet top cover of size 4X4inchand supply and fixing of new 3mm thick plastic laminated sheet top cover or PVC termination board and refitting of existing serviceable switch ,socket, regulator etc at thesame placecompleteall as specified and as directed. |
| 136 | Taking down of serviceable tube/panel lightfittingand kept safe custody andrefixing the same at direction of engr- in - chargecompleteall as specified and as directed. |
| 137 | Taking down of unserviceable PVC cashing capping of 20 mm size including serviceable copper /aluminium conductor and supply and fixing of new PVC cashing capping medium grade of size 20 mm on wall /roofwith help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lappingcompleteall as specified and as directed |
| 138 | Taking down old unserviceable mounted fan 600 mm sweep and supply and replacement of new wall mounted fan 600 mm sweep completed fixed to wall with nut bolts etc 3 core cable from connected to ceiling rose all as specified and directed. Note : OldFandeposited to E/ M Store yard. |
| 139 | Taking down of unserviceable PVC cashing capping of 25 mm size including serviceable copper /aluminium conductor and supply and fixing of new PVC cashing capping medium grade of size 25 mm on wall /roofwith help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lappingcompleteall as specified and as directed. |
| 140 | Taking down of unserviceable PVC conduit of size 20mm including serviceable copper /aluminium conductor and supply and fixing of new PVC conduit medium grade of size 20 mm on wall /roofwith help of screw and GI saddle including fixing of existingserviceable copper /aluminium conductorand all fitting fixture such as Tee, Elbow and lappingcompleteall as specified and as directed. |
| 141 | Taking down of unserviceable PVC conduit of size 25mm including serviceable copper /aluminium conductor and supply and fixing of new PVC conduit medium grade of size 25mm on wall /roofwith help of screw and GI saddle including fixing of existingserviceable copper /aluminium conductorand all fitting fixture such as Tee, Elbow and lappingcompleteall as specified and as directed |
| 142 | Taking down of unserviceable PVC Flexible conduit and supply and fixing of new PVC Flexible conduit of size 25 mmcompleteall as specified and as directed. |
| 143 | Taking down of unserviceable PVC Flexible conduit and supply and fixing of new PVC Flexible conduit of size 20 mmcompleteall as specified and as directed. |
| 144 | Taking down of unserviceable GI Flexible conduit and supply and fixing of new GI Flexible conduit of size 25 mmcompleteall as specified and as directed. |
| 145 | Taking down of unserviceable multistrand copper conductorand supply and fixing of new multistrand copper conductor(FRLS) of size 1.5 Sqmm (R Coloured) completeall as specified and as directed. |
| 146 | Taking down of unserviceable multistrand copper conductorand supply and fixing of new multistrand copper conductor(FRLS) of size 1.5 Sqmm (BlackColoured) completeall as specified and as directed. |
| 147 | Taking down old unserviceable Exhaust fanof size 300mm sweep and supply and fixing continuous duty with louvers, double ball bearing. silent operation, rust proof body and blades with fixing arrangements of size 300mm sweep, 1400 rpm, 240V complete all as specified and as directedNote : OldFandeposited to E/ M Store yard. |
| 148 | Taking down of unserviceable multistrand copper conductorand supply and fixing of new multistrand copper conductor (FRLS) of size 1.5 Sqmm (green Coloured) completeall as specified and as directed. |
| 149 | Taking down of unserviceable multistrand copper conductorand supply and fixing of new multistrand copper conductor (FRLS)of size 4.00Sqmm (R Coloured) completeall as specified and as directed. |
| 150 | Taking down of unserviceable multistrand copper conductorand supply and fixing of new multistrand copper conductor (FRLS) of size 4.00 Sqmm (BlackColoured) completeall as specified and as directed. |
| 151 | Taking down of unserviceable multistrand copper conductorand supply and fixing of new multistrand copper conductor (FRLS) of size 4.00 Sqmm (green Coloured) completeall as specified and as directed. |
| 152 | Taking down old unserviceable air circulator fan and supply and replacement new wall mounted fan 400 mm sweep completed fixed to wall with nut bolts etc 3 core service cable from connected to ceiling rose including all as specified and directed. Note : OldFandeposited to E/ M Store yard. |
| 153 | Taking down of unserviceable MCB blank plate from mcb DBs and supply and fixing of MCB blank plate from MCBDBs completeall as specified and as directed. |
| 154 | Taking down of old MCB 63 Amp TPN andSupply and fix MCB 63 Amps, TPN 4 pole, 415 volt, breaking capacity 16 KAcomplete all as specified and as directed |
| 155 | Taking down of old MCB 63 Amp TPN andSupply and fix MCB 100 Amps, TPN 4 pole, 415 volt, breaking capacity 16 KAcomplete all as specified and as directed |
| 156 | Taking down of unserviceable E Board 2ft X2Ft and supply and fixing E Board 2ft X2ftcompleteall as specified and as directed. |
| 157 | Taking down of unserviceable three phase KWH meter 4 wire andsupply and Fix of newthree phase KWH meter 4 wire with LED Display, LED meter 10-60 Amp with Box complete. Note : Oldmeter shall be deposited to E/ M Store yard. |
| 158 | Taking down of unserviceable singlephase KWH meterandsupply and Fix of newsinglephase KWH meter 2 wire with LED Display, LED meter 10-60 Amp withcrystalBox complete.Note : Oldmeter shall be deposited to E/ M Store yard. |
| 159 | Taking Down of old energy meterseal and Supply andFixing PVC energy meter seal with specific no complete all as directed. |
| 160 | Taking down old MCCB TP of capacity100 Amps and supply and fixing of thermal type of MCCBTP16 KA 100 Amps complete all as directed |
| 161 | Taking down old MCCBTPN/ FP of capacity100 Amps and supply and fixing of thermal type of MCCBTPN/FP 16 KA 100 Amps complete all as directed |
| 162 | Taking down old MCCB TPN/FP cover of capacity of 63- 160Amps andsupply and fixing MCCB TPN/FP cover of capacity of 63- 160Amps complete all as directed |
| 163 | Taking down ceiling fan of1200/1400 mm sweepany make for repairing, opening the body including blade, checking for replacement of unserviceable spares, cleaning, oiling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position testing and hanging up the same as directed. Note:New spare parts required for renewal shall be measured and paid separately as \"Supply only\". |
| 164 | Supply only the following spare parts for ceiling fans:- |
| 165 | MS split pin size 2 \" x 1/8 \" |
| 166 | Hanging bolt with nut of size 3/8\" x 3 1/2 \" . |
| 167 | Rubber bush of size 1 1/2 \" dia x 1\" thick |
| 168 | Blade of size - 1200 mm sweep. |
| 169 | Ball bearing of existing size. |
| 170 | Blade of size - 1400 mm sweep. |
| 171 | Metal bush bearing |
| 172 | Shaft (good quality of mild steel) for 1200 / 1400 mm sweep ceiling fan. |
| 173 | Taking down exhaust fan of 450/300/250 mm sweep any make for repairing, opening the body including blade, checking for replacement of unserviceable spares, cleaning, oiling, greasing, replacement of unserviceable spare by new one,,re-assembling of all components in original position testing and hanging up the same as directed Note:New spare parts required for renewal shall be measured and paid separately as \"Supply only\". |
| 174 | Supply only the following spare parts for exhaustfans :- |
| 175 | Blade for 450 mm sweep. |
| 176 | Ball bearing of existing size. |
| 177 | Blade for 300/250 mm sweep. |
| 178 | Metal bush bearing |
| 179 | Shaft for exhaust fan ( good quality of mild steel). 300/450 mm sweep. |
| 180 | Taking down Wall mounted/exhaustfan of size 600 mmof any type, any make ,by opening of body carefully checking for replacement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position.Note:New spare parts required for renewal shall be measured and paid separately as \"Supply only\". |
| 181 | Supply only the following spares for wall mountedfan:- |
| 182 | Ball bearing |
| 183 | Shaft ( good quality of mild steel). |
| 184 | Metal bush bearing |
| 185 | Blade 600 mm sweep |
| 186 | Taking down cabin fan/wall mounted of size 400/450 mm of any type, any make , by opening of body carefully checking for replacement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling, greasing, testing and fixed in original position.Note:New spare parts required for renewal shall be measured and paid separately as \"Supply only\". |
| 187 | Supply only the following spares for cabin fan/wall mounted :- |
| 188 | Ball bearing . |
| 189 | Shaft ( good quality of mild steel). |
| 190 | Metal bush bearing . |
| 191 | Blade for 400 mm sweep. |
| 192 | Supply and fix as in repair for copper flexible wire twin core of size 23/0076all as directed. |
| 193 | Supply and fix as in repair for canopy for 1400 / 1200 mm sweep ceiling fan. |
| 194 | S&F in repairs capacitor 2.5 mfd capacity all as directed. |
| 195 | S&F in repairs capacitor3.0 mfd capacity all as directed. |
| 196 | S&F in repairs capacitor4.0mfd capacity all as directed. |
| 197 | M&L for spray painting of ceiling fan of size 1200/1400 mmsweep with synthetic enamel white paint including preparation of old painted surface including writing of \"MES No\" complete all as specified and as directed |
| 198 | Taking down carefully old unserviceable geyser 25 Ltr capacity with necessary fitting and making good to damaged surface of wall to match existing finish , depositing to MES store and Supply and fix energy efficientnew 25liters capacity electrical geyser white/half white, copper container inner tank with fibre reinforced body (FRB) puff insulation for both inner tank & for hot outlet copper connection pipe with all in built in safety accessories like thermostat/automatic thermal cut out with ON /OFF /CUT out indicators all pre-wired and additional safety accessories like pressure release valve/pressure reducing valve, non return valve, rate shall be including for new PVC heavy duty pipe with brass ferrule fitting for HOT and COLD water connections fixed in same or new location as ordered/required as per manufacturers instruction with suitable size nuts & bolts, making necessary connection & testing on completion complete all as directed. |
| 199 | S&F in repairs of MS black tube, medium grade, 20mm bore, for hanging ceiling fan including necessary cutting, drilling, threading complete all as specified and as directed |
| 200 | S&F in repairs of MS black tube, medium grade, 15mm bore, for hanging of ceiling fan including necessary cutting, drilling, threading complete all as specified and as directed |
| 201 | M&L for rewinding of ceiling fan, 1200 /1400 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnishedcomplete all as specified and as directedNote : Minor parts like ball bearing, greasing, oiling, nut and bolts shall be included in the quote rate |
| 202 | M&L for rewinding of wall mounted/ Exhaust Fan fan 600 mm sweepwith super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnishedcomplete all as specified and as directedNote : Minor parts like ball bearing, greasing, oiling, nut and bolts shall be included in the quote rate |
| 203 | M&L for rewinding of Exhaust fan, 300 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnishedcomplete all as specified and as directedNote : Minor parts like ball bearing, greasing, oiling, nut and bolts shall be included in the quote rate |
| 204 | M&L for rewinding of exhaust fan 450 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnishedcomplete all as specified and as directedNote : Minor parts like ball bearing, greasing, oiling, nut and bolts shall be included in the quote rate |
| 205 | M&L for rewinding of exhaust fan 250 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnishedcomplete all as specified and as directedNote : Minor parts like ball bearing, greasing, oiling, nut and bolts shall be included in the quote rate |
| 206 | M&L for rewinding of wall mounted fan 400/450 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnishedcomplete all as specified and as directedNote : Minor parts like ball bearing, greasing, oiling, nut and bolts shall be included in the quote rate |
| 207 | Taking down of ceiling fan from one position and refixing to another location including provision of flexible cable from ceiling rose to fan complete all as specified and as directed |
| 208 | Shifting only cabin wall mounting fan from one position to another and hanging including provision of flexible cable from ceiling rose to fan complete all as specified and as directed. |
| 209 | M&L for cutting of hole through cement mortar brick wall including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core, rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed. |
| 210 | Supply and fixing in repairfastener bolts with nut and washer of size 3 inch long with complete accessories complete all as specified and as directed. |
| 211 | Taking down of unserviceable geyser of 25/50 ltr capacity of any make from the wall after disconnecting and opening of nuts and bolts carefully for repair and testing in MES store yard for ascertaining repair, refixing the same after repair/replacement of nuts and bolts, connecting to water mains and electric supply, after carrying out the repair work/ replacement complete all as specified andas directedNote : Minor parts like ball bearing, greasing, oiling, nut and bolts shall be included in the quote rate |
| 212 | Dismantling to geyser of capacity 50 ltr of any make, taking out inner tank, descaling the inner surface by scrapping carrying out soldering/ brazing/gaswelding to prevent the leakage, filling of glass wool & assembling the same after repair including replacement of required number ofstainless steel screws, nuts & bolts for fixing of siphon assembly etc complete all as specified and directed by Engineer-in-charge.Note – Glass wool shall be measured & paid as Supply only separately under concerned item. |
| 213 | Dismantling to geyser of capacity 25 ltr of any make, taking out inner tank, descaling the inner surface by scrapping carrying out soldering/ brazing/gaswelding to prevent the leakage, filling of glass wool & assembling the same after repair including replacement of required number ofstainless steel screws, nuts & bolts for fixing of siphon assembly etc complete all as specified and directedNote – Spare parts shall be measured & paid as Supply only separately under concerned item. |
| 214 | Supply only glass wool of good quality as approved for 50litre capacity of geyser complete all as specified and as directed |
| 215 | Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed |
| 216 | Supply only inner tank with connected fitting fixtureof 50 liter capacity geysers of existing make & model including testing after assembled & fixed at site complete all as specified and as directed |
| 217 | Supply only inner tank with connected fitting fixtureof 25 liter capacity geysers of existing make & model including testing after assembled & fixed at site complete all as specified and as directed |
| 218 | Taking down of unserviceable Heating element 1.5 KWfrom geysers and supply and fixing of new Heating element 1.5 KWof geysers completeall as specified and as directed. |
| 219 | Taking down of unserviceable Heating element 2.0 KWand supply and fixing of new Heating element2.0 KW completeall as specified and as directed. |
| 220 | Taking down of unserviceable Thermostat switchfrom geysersand supply and fixing of new Thermostat switchcompleteall as specified and as directed. |
| 221 | Taking down of unserviceable Safety valve from geyserand supply and fixing of new Safety valve completeall as specified and as directed. |
| 222 | Taking down of unserviceable Indicating Lampfrom geyserand supply and fixing of new LED Indicating Lamp completeall as specified and as directed. |
| 223 | Taking down of unserviceable 23 to 30 cm long ,10 mm boreC.P Connection with brass unionfrom geyserand supply and fixing of new 23 to 30 cm long ,10 mm boreC.P Connection with brass union completeall as specified and as directed. |
| 224 | Taking down of unserviceable Gun metal non return valve ,15 mm borefrom geyserand supply and fixing of new Gun metal non return valve ,15 mm bore completeall as specified and as directed. |
| 225 | Taking down of unserviceable 45 cm long , 15mm bore PVC connection pipe with brass union both ends fixed to GI Pipefrom geyserand supply and fixing of new 45 cm long , 15mm bore PVC connection pipe with brass union both ends fixed to GI Pipe completeall as specified and as directed. |
| 226 | Taking down of unserviceable apparatus plate for 50 litre from geyserand supply and fixing of new apparatus plate for 50 litre completeall as specified and as directed. |
| 227 | Taking down of unserviceable apparatus plate for 25 litre from geyserand supply and fixing of new apparatus plate for 25 litre completeall as specified and as directed. |
| 228 | Taking down of unserviceable apparatus plate for 15 litre from geyserand supply and fixing of new apparatus plate for 15 litrecompleteall as specified and as directed. |
| 229 | Taking down of unserviceable Plug top 3 pin, 16 Amp and supply and fixing plug top 3 Pin, 16 Amps completeall as specified and as directed. |
| 230 | M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying two coats of synthetic enamel paint over a coat of red oxide primer and writing the MES No with black paint complete all as specified and as directed |
| 231 | M&L for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying two coats of synthetic enamel paint over a coat of red oxide primer and writing the MES No with black paint complete all as specified and as directed |
| 232 | S&F in replacementof unserviceableflexible PVC insulated lead in lieu of provided with new flexible PVC insulatedsheathed copper conductor connection lead 3 core ,size 40/0.0076cablesuitable forgeysercomplete all as specified and as directed |
| 233 | M&L for repair of geyser body by cutting the rusted portion and remaking of body by providing new mild steel sheet and cutting in shape including welding and re painting with two coats of duco paint over a coat of red oxide primer all as specified and directed. |
| 234 | S&F in replacement NRV ISI marked of capacity 15mm/20mm dia connecting up complete all as directed. |
| 235 | S&F in replacement of top cover for geyser forcapacity 50 as required at site duly painted with spray paint all as directed. |
| 236 | S&F in replacement top cover for geyser forcapacity 25 litrs as required at site duly painted with spray paint all as directed. |
| 237 | S&F in replacement bottom cover for geyser forcapacity 50 litrs as required at site duly painted with spray paint all as directed. |
| 238 | S&F in replacement bottom cover for geyser forcapacity 25litrs as required at site duly painted with spray paint all as directed. |
| 239 | Collection of complain slip by contractor\"s representatives related toInternal Electric supply of buildingsfromSrinagar complaint cell and Main complain cell of AGE EM-I andhandover to groups consisting of oneelectrician and one helper in each group( Twogroup ,Srinagar area, BV yard, CWE ofc , GE Ofc and puspa Market , one group to be deputed at\"One group to be deputed Dhanmvantri , 34 WE area) and handover the same to the complaint cells after rectification of the complaint by respective group of electrician and helper. Note:- (i) The complain slip will be taken over byauthorised supervisor of the contractor from concern complain cells.(ii) After rectification Electrical complain Electrician should endorsed signature mentioned with full name and mobile No from user for further verification.(iii) Rep of department will endorse the complaint ofthe complain slip to be collected.(iv) Blank complaint slips shall be provided by contractor.(v) Complaints to be rectified within 48 Hour after receiving the complaint slip. Failing which, penalty ofRs 300 shall be deducted from contractor.(vi) All electrical materials and labour charges to be used forrectification of complaints shall be measured and paid separately under relevant item of this schedule.(vii) If any complaints is not rectified due to any justified reason, then the complaint slip shall be returned to the department with proper justification.(viii) Pls note that no manpower are being procured vide this item, only services to be provided by the contractor. |
| 240 | S&F in replacement 2.5 sqmm copper cable three core rubber insulatedall as specified and directed. |
| 241 | S&F in replacement air pressure release safety valve 15mm diasuitable for geyser of 25/50 Ltrs capacity complete all as specified and as directed. |
| 242 | S&F in replacement of Electronic sensor for light/Fancomplete all as specified and as directed |
| 243 | S&F in replacement of PVC insulation tape 25mm x 25Mtr ofelectrical conductor complete all as specified and as directed |
| 244 | Supply and fixing as in repair rubber insulation tape 25 cm width 2.5 Mtr long fixing of connection Electrical equipmentcomplete all as specified and as directed |
| 245 | S&F in replacement of copper lugs 6 Sqmm complete all as specified and as directed |
| 246 | S&F in replacement of copper lugs 10 Sqmm complete all as specified and as directed |
| 247 | S&F in replacement of copper lugs 16 Sqmm complete all as specified and as directed |
| 248 | S&F in replacement of Electronic driver of capacity 36/40 W for LED Panel light complete all as specified and as directed |
| 249 | Taking down of unserviceable conventional type tube light fitting andsupply and fixing ofEmergency LEDTube light fittingof capacity 20 wattcompleteall as specified and as directed . |
| 250 | (f)Provisioning of cubicle 05 Nos suitable foraccommodating the following MCCBs switches.(i) MCCBs 250 Amp FP 36 KA Microprocessor -01 (incoming)(ii) MCCBs 160 Amp FP 36 KA - 01 No (Outgoing)(iii) MCCBs 63 Amp TP 16 KA - 04 Nos (Outgoing) |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy