Electrification Of Power House Control Room For 3 X 20 Mw Rangit Power Station, South Sikkim, Sikkim ( India ) Electrification Of Power House Control Room For 3 X 20 Mw Rangit Power Station, South Sikkim, Sikkim ( India ) -Sikkim

National Hydroelectric Power Corporation Limited has published Electrification Of Power House Control Room For 3 X 20 Mw Rangit Power Station, South Sikkim, Sikkim ( India ) Electrification Of Power House Control Room For 3 X 20 Mw Rangit Power Station, South Sikkim, Sikkim ( India ) . Submission Date for this Tender is 17-01-2022. Electrification Work Tenders in Sikkim. Bidders can get complete Tender details and download the document.




Tender Notice

30483459
Electrification Of Power House Control Room For 3 X 20 Mw Rangit Power Station, South Sikkim, Sikkim ( India ) Electrification Of Power House Control Room For 3 X 20 Mw Rangit Power Station, South Sikkim, Sikkim ( India )
Open Tender
Indian
Sikkim
17-01-2022

Tender Details

Electrification Of Power House Control Room For 3 X 20 Mw Rangit Power Station, South Sikkim, Sikkim ( India ) Electrification Of Power House Control Room For 3 X 20 Mw Rangit Power Station, South Sikkim, Sikkim ( India )

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
INR 10.29 Lakhs /-

BOQ Items

Name of Work: Electrification of Power House Control Room for 3 x 20 MW Rangit Power Station, South Sikkim, Sikkim (India)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Point Length 6 M
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Point Length 11 M
3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Point Length 16 M
4Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Point Length 21 M
5Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Point Length 26 M
6Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Point Length 29 M
7COPPER CONTROL CABLES: ARMOURED CONFORMING TO IS : 7098 PART-1 4 Core x 6 sq.mm
8RECESSED MOUNTED CRCA LED PANEL CONFORMIN LED Panel 2 x 2 36 Watt
9SLEEK PLUS RECESSED MOUNTED LED (SQUARE /ROUND) Sleek plus 18 watt (CW/OW/WW)
10RECESSED MOUNTED ROUND/SQUARE COB ADJUSTABLE LED Zoom 12 watt (CW/OW/WW)
11Wall mounting fan 18" (Havells) Conforming to IS: 2997
12Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
13Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) asrequired . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door
14Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A
15Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Single Pole
16Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door SPN MCBDB
17Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
18Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
19Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
20Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.6 Module (200mmX75mm)
21Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.3 Module (100mmX75mm)
22Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
23Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket
24Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
25Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.