Bids Are Invited For Icaf System ( M / S Sargam Metal, Chennai ) - Lb 5004Whr Sea Chest Icaf Anode Cable Defective. Cable To Be Renewed Alongwith Replacement Of Anode During Dry Docking Of Ship.Gsl Remarks:Do Renewal Of Cable. Renewal Of Anodes-Goa

Department of Defence Production has published Bids Are Invited For Icaf System ( M / S Sargam Metal, Chennai ) - Lb 5004Whr Sea Chest Icaf Anode Cable Defective. Cable To Be Renewed Alongwith Replacement Of Anode During Dry Docking Of Ship.Gsl Remarks:Do Renewal Of Cable. Renewal Of Anodes. Submission Date for this Tender is 25-01-2022. Kitchen Equipment Tenders in Goa. Bidders can get complete Tender details and download the document.




Tender Notice

30477922
Corrigendum : Bids Are Invited For Icaf System ( M / S Sargam Metal, Chennai ) - Lb 5004Whr Sea Chest Icaf Anode Cable Defective. Cable To Be Renewed Alongwith Replacement Of Anode During Dry Docking Of Ship.Gsl Remarks:Do Renewal Of Cable. Renewal Of Anodes
Indian
Goa
25-01-2022

Tender Details

Bids Are Invited For Icaf System ( M / S Sargam Metal, Chennai ) - Lb 5004Whr Sea Chest Icaf Anode Cable Defective. Cable To Be Renewed Alongwith Replacement Of Anode During Dry Docking Of Ship.Gsl Remarks:Do Renewal Of Cable. Renewal Of Anodes Under Aiamc. Cable Length – 02 Mtrs, Size – 2.5 Mm2 X 3 Core. Material – Firm Supply.All In Way Jobs Included.Cable - Firm Supply , Main Switch Board ( Port & Stbd ) Qty-02 Nos And Emergency Switch Board ( M / S Rrmi ) Qty-01 No Pms ( Port & Stbd ) ( M / S Deif Qty -02 Nos ) Pac Firm M / S Rrmi For Msb And M / S Deif For Pms - La 5033The Following Instrument / Measuring Device Of Both Main Switch Boards And Em. Switch Board To Be Calibrated And Limits To Be Red Marked. Calibration Certificate To Be Handed Over To Ship Staff. ( Maintenance Schedule No. Lp-05 ) Sldescriptionrangeqty ( A ) Voltmeter0 – 300 V3 ( B ) Voltmeter0 – 600 V10 ( C ) Insulation Meter0-Infinite7 ( D ) Ammeter0 – 1000 A3 ( E ) Ammeter0 – 1600 A1 ( F ) Ammeter0 – 2000 A3 ( G ) Ammeter0 – 6000 A12 ( H ) Ammeter0 – 10000 A6 ( J ) Frequency Meter45 Hz – 55 Hz10 ( K ) Kw Meter0 To 200 Kw1 ( L ) Kw Meter-50 To 500Kw 1 ( M ) Kw Meter -150 To 1500 Kw6 ( N ) Kw Meter-2875 To 2875 Kw3 ( P ) Synchroscope-- 7 ( Q ) Power Factor Meter 0-1-0 10 ( R ) Phase Sequence Meter --1Gsl Remarks:Do.Spares – Cg Supplymaterial – Firm Supplyfirm To Provide Calibration Certificate & Safety Check Report. All In Way Jobs Included. , Shore Connection Box ( M / S Marine Electrical ( 02 Nos ) - La 5142Calibrate Following Instrument. Calibration Certificate To Be Handed Over To Ship. ( Maintenance Schedule No. Lp-10 ) .Sldescription Specification Qty ( A ) Volt Meter0-500 V02 No. ( B ) Ammeter 0-1000 A02 No. ( C ) Phase Sequence Meter -- 02 No. ( D ) Power Factor Meter -- 02 No.Gsl Remarks:Dospares – Cg Supplymaterial – Firm Supplyall In Way Jobs Included.Calibration Certificate To Be Provided By Firm. , Shore Connection Box ( M / S Marine Electrical ( 02 Nos ) 1 - La 5143Overhaul Shore Distributionconnection Box Consist Of Contactor ( 3Tf-6844-Oc ) , Qty – 02 Nos, Calibrate 01 No. Voltmeter, Range 0-600V, And 02 Nos Current Transformers.Renewdefectivemeter.Calibrationcertificatewithlimitstobe Handed Over To Ship.Gsl Remarks:Dospares – Cg Supplymaterial – Firm Supplyall In Way Jobs Included.Calibration Certificate To Be Provided By Firm. , Galley Equipment ( M / Sdenki & Sushma Electricals, Mumbai ) - La 5149Overhaulfollowinggalleyequipmentmotor.Overhaulingincludesrecordof Insulation Prior Dismantling Of Motor And Withdrawal Of Rotor, Renewal Of De / Nde Ball Bearing On Dismantling Of Motor, Spray Painting Of Heat Resistive Paint On External / Internal Part Of Yoke, Apply Of Varnish And Baking Up For 10 Hour. Renewal Of All Consumable Associated With Motor ( Cooling Fan, Foundation Nut, Bolt, Screw, Junctioncoverwithgasketandterminalstrip ) .Recordingof Insulation, Starting / Running Current And Proving Of Motor For Satisfactory Operation On Completion Of Overhauling. ( Maintenance Schedule No. Lp-55 & 56 ) . All Materials / Spares To Be Supplied Under Scope Of Firm.Slequipment Motor Specificationqty ( A ) Electric Meat Mincer 230V, 0.75 Kw1 ( B ) Heavy Duty Grinder230 V, 1.5 Kw 1 ( C ) Dough Mixture415v, 1.5 Kw1 ( D ) Potato Peeler 415V, 1.5 Kw 1Gsl Remarks:Do.Spares – Cg Supply. Material – Firm Supply.All In Way Jobs Included. , Battery Charger ( M / S Marine Electrical ) - La 5154Overhaul 08 In No Battery Charger 230 V To 24 V Dc, Capacity, 60A. Overhauling Includes Cleaning / Functional Check Of Single Phase Double Wound Transformer, 230 V To 40 V, 50Hz, 2.5 Kva Qty-06 No, Single Phase Scr Controlled Bridge Rectifier 24 V, 75A, Qty-08 No, Single Phase Scr Controlled Sensing Circuit 230 V 1Ph 50 Hz, Qty-08 No, Diode ( S4hr63 ) 63A, Qty- 08 No. Calibrate Volt Meter ( Size – 96X96 Mm ) , 0-50V Dc Heaving Red Mark Of 24 V Dc Qty-08 No, Ammeter ( Size – 96X96 Mm ) 0-75 A Dc R / M 60A With External Shunt 75 Mv, Qty-08 No. Renew All Defective / Deterioratedcomponentsandcableterminalconnector.Calibration Certificate With Limits To Be Handed Over To Ship Staff. ( Maintenance Schedule No. Lp-50 ) .Gsl Remarks:Do.Spares – Cg Supply. Material – Firm Supply.All In Way Jobs Included. Calibration Certificate To Be Provided By Firm. , Battery Charger ( M / S Marine Electrical ) 1 - La 5155Overhaul 02 In No Portable Battery Charger 24 V, Capacity – 20 A. Overhauling Includes Cleaning / Functional Check Single Phase Double Wound Transformer, 230 V To 40 V, 50Hz, 1000 Va, Qty-02 No, Single Phase Scr Controlled Bridge Rectifier 24 V, 50A, Qty-02 No, Single Phase Scr Control And Sensing Circuit 230 V 1Ph 50 Hz, Qty-02 No, Diode ( S2hr40 ) , 40A, Qty 02 No. Calibrate Volt Meter ( Size 96X96 Mm ) 0-50V Dc Heaving Red Mark At 24 V Dc, Qty-02 No.Ammeter ( Size – 96X96 Mm ) , 0-75 A Dc R / M 30A With External Shunt 75 Mv, Qty-02 Nos. Renew All Defective / Deteriorated Components And Cable Connector. Calibration Certificate With Limits To Be Handed Over To Ship Staff. ( Maintenance Schedule No. Lp-50 ) . Gsl Remarks:Do.Spares – Cg Supply. Material – Firm Supply.All In Way Jobs Included.Calibration Certificate To Be Provided By Firm. , Aerials - La 5218Sldescription Of Whip Aerial Qty ( A ) Vhf Rt & , Dsc , 5022 4 ( B ) Ais ( Gps &Vhf ) 2 ( C ) Aero Vhf1 ( D ) 1Kw Mf / Hf Tx / Rx Codan1 ( E ) 100W , Hf / Rx Tr 2400 1 ( F ) Ndb 1 ( G ) Dsc Watch Receiver, 2187.5Khz2 ( H ) Dsc Watch Receiver Ch-70, 6000A2 ( J ) Vlf / Hf Duplexreceivers Ek 8962 ( K ) Mss Tx / Rx2 ( L ) Navtex Receiver 1 ( M ) Fbb 150 1Gsl Remarks:Do Only Paint Of Aerials. Rf Paint - Firm Supply.Quantity Of Paint – 40 Ltrsremaining Scope Of Job By Ss / Underdfp. , Miscellaneous:- - Lb 5221Galley Hot Plate – 02X 5Kw Galley Plate Base Deformed And Inclined. Deformed Base To Be Repaired And Re-Fabricated So To Remove Inclination. Cabling Inside Structure / Beneath Hotplate Elements Deteriorated, Cabling To Be Replacedgsl Remarks:Do.Spares – Cg Supply. Material – Firm Supply.All In Way Jobs Included. , Window Wiper ( Make- M / S Jung-A Marine ) - Lb 5224Repair Essential On 04 In Nos. Window Wiper Motor 230V, 1Phase, 50Hz, ( Make- M / S Jung-A Marine ) And 02 In Nos. Control Panel ( Lso & Bridge ) View Motors Getting Stuck Intermittently During Operation And Gears Getting Slipped.Gsl Remarks:Do.Spares & Material – Firm Supply. All In Way Jobs Included. , Bilge Sensor - Lb 522514Bilgesensorshingesandjunctionboxesfittedinconfinedspaces / Bilges Deteriorated / Rusted To Be Renewed.Gsl Remarks:Do.Spares & Material – Firm Supply. All In Way Jobs Included. , Water Tight Sliding Door - Lb 5226Intermittent Failure Of Plc For Water Tight Sliding Door Indication On Ipms. View Failure Of Plc, Operation, Not Available From Ipms. Plc To Be Reprogrammed / Repaired.Gsl Remarks:Do.Spares & Material – Firm Supply. All In Way Jobs Included. Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jan-2022 17-01-2022
2 17-Jan-2022 18-01-2022
3 18-Jan-2022 19-01-2022
4 24-Jan-2022 25-01-2022

Key Value

Document Fees
Refer document
EMD
INR 62500.0 /-
Tender Value
Refer document

BOQ Items

Sl. No. Item TitleItem Description
1ICAF SYSTEM ( M/S SARGAM METAL, CHENNAI)LB 5004 WHR Sea Chest ICAF anode cable defective. Cable to be renewed alongwith replacement of Anode during dry docking of ship. GSL remarks: DO renewal of cable. Renewal of Anodes under AIAMC. Cable Length – 02 Mtrs, Size – 2.5 mm2 x 3 core. Material – firm supply. All in way jobs included. Cable - firm SUPPLY
2MAIN SWITCH BOARD (PORT & STBD) QTY-02 NOS AND EMERGENCY SWITCH BOARD (M/S RRMI) QTY-01 NO PMS (PORT & STBD) (M/S DEIF QTY -02 NOS) PAC FIRM M/S RRMI FOR MSB AND M/S DEIF FOR PMSLA 5033 The following Instrument/measuring device of both Main Switch Boards and Em. Switch Board to be calibrated and limits to be Red Marked. Calibration certificate to be handed over to Ship Staff. (Maintenance schedule no. LP-05) SlDescriptionRangeQty (a) Voltmeter0 – 300 V3 (b) Voltmeter0 – 600 V10 (c) Insulation Meter0-Infinite7 (d) Ammeter0 – 1000 A3 (e) Ammeter0 – 1600 A1 (f) Ammeter0 – 2000 A3 (g) Ammeter0 – 6000 A12 (h) Ammeter0 – 10000 A6 (j) Frequency Meter45 Hz – 55 Hz10 (k) KW Meter0 to 200 KW1 (l) KW Meter-50 to 500KW 1 (m) KW Meter -150 to 1500 KW6 (n) KW Meter-2875 to 2875 KW3 (p) Synchroscope-- 7 (q) Power factor Meter 0-1-0 10 (r) Phase Sequence meter --1 GSL remarks: DO. Spares – CG supply Material – firm supply firm to provide calibration certificate & safety check report. All in way jobs included.
3SHORE CONNECTION BOX (M/S MARINE ELECTRICAL(02 NOS)LA 5142 Calibrate following instrument. Calibration certificate to be handed over to Ship. (Maintenance schedule no. LP-10). SlDescription Specification Qty (a)Volt Meter0-500 V02 No. (b)Ammeter 0-1000 A02 No. (c)Phase sequence meter -- 02 No. (d) Power factor meter -- 02 No. GSL remarks: DO Spares – CG supply Material – firm supply All in way jobs included. Calibration certificate to be provided by firm.
4SHORE CONNECTION BOX (M/S MARINE ELECTRICAL(02 NOS) 1LA 5143 Overhaul Shore Distributionconnection Box consist of Contactor (3TF-6844-OC), Qty – 02 Nos, Calibrate 01 no. voltmeter, range 0-600V, and 02 Nos Current transformers.Renewdefectivemeter.Calibrationcertificatewithlimitstobe handed over to Ship. GSL remarks: DO Spares – CG supply Material – firm supply All in way jobs included. Calibration certificate to be provided by firm.
5GALLEY EQUIPMENT (M/SDENKI & SUSHMA ELECTRICALS, MUMBAI)LA 5149 Overhaulfollowinggalleyequipmentmotor.Overhaulingincludesrecordof Insulation prior dismantling of motor and withdrawal of rotor, Renewal of DE/NDE ball bearing on dismantling of motor, Spray Painting of heat resistive paint on External/Internal part of Yoke, apply of varnish and baking up for 10 hour. Renewal of all consumable associated with motor (cooling fan, foundation nut, bolt,screw,junctioncoverwithgasketandterminalstrip).Recordingof insulation, starting/running current and proving of motor for satisfactory operation on completion of overhauling. (Maintenance schedule no. LP-55 & 56). All Materials/spares to be supplied under scope of firm. SlEquipment Motor SpecificationQty (a)Electric Meat mincer 230V,0.75 KW1 (b)Heavy duty Grinder230 V,1.5 KW 1 (c)Dough Mixture415V,1.5 KW1 (d)Potato Peeler 415V,1.5 KW 1 GSL remarks: DO. Spares – CG supply. Material – firm supply. All in way jobs included.
6BATTERY CHARGER (M/S MARINE ELECTRICAL)LA 5154 Overhaul 08 in no battery charger 230 V to 24 V DC, Capacity, 60A. Overhauling includes Cleaning /functional check of Single phase double wound transformer, 230 V to 40 V, 50Hz, 2.5 KVA Qty-06 No, Single phase SCR controlled bridge rectifier 24 V, 75A, Qty-08 No, Single phase SCR controlled Sensing circuit 230 V 1ph 50 Hz, Qty-08 No, Diode (S4HR63) 63A, Qty- 08 No. Calibrate Volt meter (size – 96X96 mm), 0-50V DC heaving red mark of 24 V DC Qty-08 No, Ammeter (size – 96X96 mm) 0-75 A DC R/M 60A with external shunt 75 mV, Qty-08 No. Renew all defective/deterioratedcomponentsandcableterminalconnector.Calibration certificate with limits to be handed over to ship staff. (Maintenance schedule no. LP-50). GSL remarks: DO. Spares – CG supply. Material – firm supply. All in way jobs included. Calibration certificate to be provided by firm.
7BATTERY CHARGER (M/S MARINE ELECTRICAL) 1LA 5155 Overhaul 02 in no portable battery charger 24 V, Capacity – 20 A. Overhauling includes cleaning /functional check Single phase double wound transformer, 230 V to 40 V, 50Hz, 1000 VA, Qty-02 No, Single phase SCR controlled bridge rectifier 24 V, 50A, Qty-02 No, Single phase SCR control and Sensing circuit 230 V 1ph 50 Hz, Qty-02 No, Diode (S2HR40), 40A, Qty 02 No. Calibrate Volt meter (size 96X96 mm) 0-50V DC heaving red mark at 24 V DC, Qty-02 No.Ammeter (size – 96X96 mm), 0-75 A DC R/M 30A with external shunt 75 mV, Qty-02 nos. Renew all defective /deteriorated components and cable connector. Calibration certificate with limits to be handed over to ship staff. (Maintenance schedule no. LP-50). GSL remarks: DO. Spares – CG supply. Material – firm supply. All in way jobs included. Calibration certificate to be provided by firm.
8AERIALSLA 5218 SlDescription of Whip Aerial Qty (a) VHF RT & ,DSC ,5022 4 (b)AIS (GPS &VHF)2 (c) AERO VHF1 (d)1KW MF/HF Tx/RX CODAN1 (e)100W ,HF/RX TR 2400 1 (f)NDB 1 (g) DSC WATCH Receiver, 2187.5KHZ2 (h)DSC WATCH RECEIVER CH-70, 6000A2 (j) VLF/HF DuplexReceivers EK 8962 (k) MSS Tx / Rx2 (l)NAVTEX RECEIVER 1 (m)FBB 150 1 GSL remarks: DO only paint of aerials. RF Paint - firm supply. Quantity of paint – 40 ltrs Remaining scope of job by SS/under DFP.
9Miscellaneous:-LB 5221 Galley hot plate – 02x 5KW galley plate base deformed and inclined. Deformed base to be repaired and re-fabricated so to remove inclination. Cabling inside structure/beneath hotplate elements deteriorated, cabling to be replaced GSL remarks: DO. Spares – CG supply. Material – firm Supply. All in way jobs included.
10WINDOW WIPER (MAKE- M/S JUNG-A MARINE)LB 5224 Repair essential on 04 in nos. window wiper Motor 230V, 1Phase, 50Hz, (Make- M/S JUNG-A MARINE) and 02 in nos. Control panel (LSO & bridge) view motors getting stuck intermittently during operation and gears getting slipped. GSL remarks: DO. Spares & Material – firm Supply. All in way jobs included.
11BILGE SENSORLB 5225 14bilgesensorshingesandjunctionboxesfittedinconfinedspaces/bilges deteriorated / rusted to be renewed. GSL remarks: DO. Spares & Material – firm Supply. All in way jobs included.
12WATER TIGHT SLIDING DOORLB 5226 Intermittent failure of PLC for water tight sliding door indication on IPMS. View failure of PLC, operation, not available from IPMS. PLC to be reprogrammed/ repaired. GSL remarks: DO. Spares & Material – firm Supply. All in way jobs included.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail