}

Bids Are Invited For Sicads Make: Environics, Feland, Model - ( A ) Overhaul The Chemical Agent Detection System And Its Following Sub Units / Accessories. Overhauling Includes Replacement Of All Internal And External Filters And Pipes For Air Inlet A-Goa

Department of Defence Production has published Bids Are Invited For Sicads Make: Environics, Feland, Model - ( A ) Overhaul The Chemical Agent Detection System And Its Following Sub Units / Accessories. Overhauling Includes Replacement Of All Internal And External Filters And Pipes For Air Inlet A. Submission Date for this Tender is 17-02-2022. Nuts Supply Tenders in Goa. Bidders can get complete Tender details and download the document.




Tender Notice

30476616
Corrigendum : Bids Are Invited For Sicads Make: Environics, Feland, Model - ( A ) Overhaul The Chemical Agent Detection System And Its Following Sub Units / Accessories. Overhauling Includes Replacement Of All Internal And External Filters And Pipes For Air Inlet A
Indian
Goa
17-02-2022

Tender Details

Bids Are Invited For Sicads Make: Environics, Feland, Model - ( A ) Overhaul The Chemical Agent Detection System And Its Following Sub Units / Accessories. Overhauling Includes Replacement Of All Internal And External Filters And Pipes For Air Inlet And Outlet And Replacement Of Any Defective Components In The Unit : ( I ) Control Light Unit ( Dchq ) , Detector Unit ( Dchq Lobby ) , Detector Unit ( Helo Deck Catwalk Port ) , Detector ( Helo Deck Catwalk Stbd ) , Air Intake Duct And Sp1 Sample Probe ( Catwalk Port ) , Air Intake Duct And Sp1 Sample Probe ( Catwalk Stbd ) , Purchase And Replacement Of Shock Mountings And Base Nuts Of Detector Assembly And Control Light Unit - 04 Nos, Carry Out Test Of The Complete System: Sicads Quantity One Cu&Sensorsoems Localrepresentative:M / S Environics , 1 ( Sicads ) - ( A ) Carry Out Serviceability Checks And Replace The Defective Components : - ( I ) Power Main Switch-01, Fan Assembly - 01, Air Pump -01, Battery 12V Rechargeable Nicd - 01, Pump Control Board - 01, Over Voltage Suppressor Module Pt 5-Hf-12Dc-St -01, Ion Mobility Pectrometric Sensor ( Im Cell ) - 01, Semiconductor Sensor ( Sc Cell ) - 01, Indicating Leds - 15 ( X ) Power / Test Switch - 01, Buzzer - 01, Audio Switch - 01, Supply And Relace Of All Cabinet Filters ( Qty-03 ) , Air Inlet Filters ( Qty-06 ) And Air Outletfilters ( Qty-06 ) Of All Three Sensors. , 2 ( Sicads ) - Interfacing Of Sicads System With Bdcs To Be Undertaken And Proved. , Mandotary Spares 1 ( Na ) - External Filters , 2 ( Na ) - Internal Filter , 3 ( Na ) - External Pump , 4 ( Na ) - Sensor Inlet Filter , 5 ( Na ) - Im Cell Tester , 6 ( Na ) - Sc Cell Tester , 7 ( Na ) - Cabin Fan Assy. Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Jan-2022 13-01-2022
2 14-Jan-2022 18-01-2022
3 07-Feb-2022 11-02-2022
4 10-Feb-2022 17-02-2022

Key Value

Document Fees
Refer document
EMD
INR 37500.0 /-
Tender Value
Refer document

BOQ Items

Sl. No. Item TitleItem Description
1SICADS Make: Environics, Feland, Model(a) Overhaul the Chemical Agent Detection System and its following sub units/accessories. Overhauling includes replacement of all internal and external filters and pipes for air inlet and outlet and replacement of any defective components in the unit : (i) Control Light Unit (DCHQ) , Detector Unit (DCHQ lobby) ,Detector unit (Helo deck catwalk port) , Detector (Helo deck catwalk stbd) , Air intake duct and SP1 Sample probe (catwalk port) , Air intake duct and SP1 Sample probe (catwalk stbd) , Purchase and replacement of shock mountings and base nuts of Detector assembly and Control Light Unit - 04 Nos ,Carry out Test of the complete system : SICADS Quantity One CU&SensorsOEM"s LocalRepresentative:M/s Environics
21 (SICADS)(a) Carry out serviceability checks and replace the defective components : - (i) power main switch-01 , Fan assembly - 01 , Air Pump -01 , Battery 12V rechargeable NiCd - 01 , Pump Control Board - 01 , Over voltage suppressor module PT 5-HF-12DC-ST -01 , Ion Mobility pectrometric Sensor (IM cell) - 01 ,Semiconductor Sensor (SC cell) - 01 , Indicating LEDs - 15(x) power/ Test switch - 01 , Buzzer - 01 , Audio switch - 01 , Supply and relace of all cabinet filters (qty-03), air inlet filters (qty-06) and air outletfilters (qty-06) of all three sensors.
32 (SICADS)Interfacing of SICADS system with BDCS to be undertaken and proved.
4Mandotary spares 1 (NA)EXTERNAL FILTERS
52 (NA)INTERNAL FILTER
63 (NA)EXTERNAL PUMP
74 (NA)SENSOR INLET FILTER
85 (NA)IM CELL TESTER
96 (NA)SC CELL TESTER
107 (NA)CABIN FAN ASSY.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail