Renovation Work By Installing Decorative Pole And Post Top Led Lights On Heritage Walk-Way In Jaipur Municipal Corporation Heritage Area Financial Year 2021-22 , ( 44.1 ) Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Isi, JAIPUR-Rajasthan

Department Of Local Bodies has published Renovation Work By Installing Decorative Pole And Post Top Led Lights On Heritage Walk-Way In Jaipur Municipal Corporation Heritage Area Financial Year 2021-22 , ( 44.1 ) Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Isi. Submission Date for this Tender is 05-01-2022. Coats and Jackets Tenders in JAIPUR Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

30453634
Corrigendum : Renovation Work By Installing Decorative Pole And Post Top Led Lights On Heritage Walk-Way In Jaipur Municipal Corporation Heritage Area Financial Year 2021-22 , ( 44.1 ) Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Isi
Open Tender
Indian
Rajasthan
JAIPUR
05-01-2022

Tender Details

Renovation Work By Installing Decorative Pole And Post Top Led Lights On Heritage Walk-Way In Jaipur Municipal Corporation Heritage Area Financial Year 2021-22 , ( 44.1 ) Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Isi Marked ( Is:694 ) Of 1.1 Kv Grade And Approved Make In Existing Surface Or Recessed Conduit / Casing Capping Including Making Connections Etc. As Required. , ( 44.1.7 ) 2 X 2.5 Sq.Mm , ( 45.2 ) P & F In Position Frame Made Out Of M.S. Angle ( Riveted Or Welded ) Finished With Two Coats Of Red Oxide And Enamel Paint Of Following Sizes As Required. , ( 45.2.5 ) 50Mm X 50Mm X 6Mm , ( 45.5 ) P & F Sheet For Boxes / Frames Including Making Holes For Switches Etc, With Brass Screws, Washers / Zinc Plated Nut And Bolts As Required. , ( 45.6 ) 3.0 Mm Thick Synthetic Phenolic Resin Bonded Laminates Confirming To Is:2046 Bakelite Sheet , ( 46.6.2 ) 6.4 Mm Thick , ( 46.1 ) P&F 240 / 415 V Mcb Of Breaking Capacity Not Less Than 10 Ka ( B / C / D Tripping Characteristic ) Isi Marked Is 8828 ( 1996 ) ] / Conforming To Iec 60898 In Existing Board / Sheets Including Making Connections With Lugs, Testing Etc. As Required. , ( 46.1.1 ) Single Pole Mcb , ( 46.1.1.2 ) 6 A To 32 A Rating , ( 48.1 ) Sitc Of Walll / Free Standing Floor Mounted Dust And Vermin Proofcompartmentalised Cubical Panel Made Out Of Crca Sheet, Required Hardware, Duly Painted By Two Coats Of Zinc / Red Oxide Primer Followed By Powder Coated / Epoxy / Pu Painted With Phosphatisation In Grey Or Required Shade After Rinsing. The Panel Having Pu / Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness, Separate Detachable, Gland Plate M.S. Base Channel, Hinged Door With Locking Arrangement For Equipment / Switchgear. Thickness Of Sheet Shall Not Be Less Than 1.6Mm Up To 600Mm Length / Width Of Any Compartment And Be Of 2.0Mm Above 600Mm. Load Bearing Structure Shall Be Of 2.0Mm Thick Sheet Supported By Base M.S.Channel If Required. Side Walls And Cable Alley Compartments Having Bolted Type Doors With Detachable Extension Type Structure ( Only Outer Area On All Sides Shall Be Measured And Panel To Be Fabricated From Cpri Approved Fabricator ) . , ( 48.2 ) Supplying And Fixing Of Aluminium / Copper Bus Bar By Means Of Smc / Dmc Type Insulator, High Tensile Nuts And Bolts Spring Washers In Existing Panel Including Bending , Cutting In Required Shape And Size And Colour Coding With Heat Shrinkable Pvc Sleeves , ( 48.2.1 ) Electrolytic Grade Aluminium Bus Bar , ( 48.15 ) P & F Of Ac Operated Heavy Duty 230 / 440 Volt Power Contactor Conforming To Is:13947-4-1 / Iec:947-4-1Having Provision Of Mechanical Interlocking, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. , ( 48.15.2 ) 4 Pole Ac 1 Rating Contactors , ( 48.15.2.4 ) 46 To 60 Amp , ( 48.20 ) P&F Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16- 20 Amperes Including Making Connection, Programming Etc. As Required , ( 48.20.3 ) One Day & Week Reserve ( Digital Type ) , ( 51.1 ) Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. , ( 51.1.4 ) 10.0 Sq.Mm , ( 51.1.4.1 ) 2 Core , ( 51.1.5 ) 16.0 Sq.Mm , ( 51.1.5.3 ) 4 Core , ( 52.8 ) Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. , ( 52.8.4 ) 2 X 10.0 Sq.Mm , ( 52.8.42 ) 4 X 16.0 Sq.Mm , ( 54.15 ) Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I.Coating , ( 54.15.1 ) With Pipe In Pipe Technology With 80-100 Micron G.I. Coating , ( 54.15.1.2 ) G.I. Pipe 2000 Mm Long , 80 / 40 Mm , Terminal 12 Mm G.I. Strip , ( 49.7 ) Sitc Of Quick Make And Quick Break 4 Pole Current Limiting Mccb Having Following Current Rating, Short Circuit Breaking Capacity At 440 / 415 V, 50 Hz; O / L & S / C Settings And Conforming To Is 13947-2 / Iec 60947- 2 With Front Face And Centralised Adjustable, Line Load Interchangeability, Having Positive Isolation Capability, Provision For Uvr , Shunt Trip , Earth Fault Trip, Push ( Test ) To Trip , Including Making Connections With Lugs / Spreaders Etc. As Required , ( 49.7.1 ) With Thermal Magnetic Release , ( 49.7.1.2 ) Up To 100 Amp , 16 / 25 Ka, Adjustable O / L & Fixed S / C Setting

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Dec-2021 Corrigendum Document Other 05-01-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 57023.0 /-
Tender Value
INR 28.51 Lakhs /-

BOQ Items

Name of Work: Renovation work with LED Post Top and Decorative Poleat Heritage Walk Way
Sl. No. Item Description
1(44.1) Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
2(44.1.7)2 x 2.5 sq.mm
3(45.2) P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and enamel paint of following sizes as required.
4(45.2.5)50mm x 50mm x 6mm
5(45.5) P & F sheet for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required.
6(45.6) 3.0 mm thick Synthetic phenolic resin bonded laminates confirming to IS:2046 Bakelite sheet
7(46.6.2)6.4 mm thick
8(46.1) P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required.
9(46.1.1)Single pole MCB
10(46.1.1.2)6 A to 32 A rating
11(48.1) SITC of walll/free standing floor mounted dust and vermin proofcompartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S.channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator).
12(48.2) Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves
13(48.2.1)Electrolytic grade aluminium bus bar
14(48.15) P & F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required.
15(48.15.2)4 pole AC 1 Rating contactors
16(48.15.2.4 ) 46 to 60 Amp
17(48.20) P&F of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16- 20 amperes including making connection, programming etc. as required
18(48.20.3)One day & week reserve (digital type )
19(51.1) Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
20(51.1.4 ) 10.0 Sq.mm
21(51.1.4.1)2 core
22(51.1.5 ) 16.0 Sq.mm
23(51.1.5.3)4 core
24(52.8) Supplying and making one end termination with heavy duty double compression brass gland SIBG type, aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.
25(52.8.4)2 x 10.0 sq.mm
26(52.8.42)4 x 16.0 sq.mm
27(54.15) Maintenance free gel earthing with pipe in pipe /Strip in Pipe technology filled with anti corrosive conductive compound (CPRI tested) below the ground in 150 -200 mm dia earth pit and surrounding filled with required mineral filling compound (MFC should have hygroscopic proper ty to retain the moisture for long time to create low resistance Zone) and C.C. finished chamber covered with hinge type with locking arrangement C.I cover. C.I. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes With pipe in pipe technology (inner pipe dia / outer pipe dia) 80 -100 micron G.I.coating
28(54.15.1)With pipe in pipe technology with 80-100 micron G.I. coating
29(54.15.1.2)G.I. pipe 2000 mm long , 80/40 mm , terminal 12 mm G.I. strip
30(49.7) SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 13947-2 / IEC 60947- 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push (test) to trip , including making connections with lugs / spreaders etc. as required
31(49.7.1)With Thermal Magnetic Release
32(49.7.1.2)up to 100 Amp , 16/25 kA, adjustable O/L & fixed S/C setting