Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Palampur Mil Stn Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Palampur Mil Stn, Palampur Mil Stn-Himachal Pradesh

Military Engineer Services-MES has published Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Palampur Mil Stn Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Palampur Mil Stn. Submission Date for this Tender is 19-01-2022. Power Factor Panel Tenders in Palampur Mil Stn Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30428166
Corrigendum : Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Palampur Mil Stn Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Palampur Mil Stn
Open Tender
Indian
Himachal Pradesh
Palampur Mil Stn
19-01-2022

Tender Details

Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Palampur Mil Stn Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Palampur Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jan-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-01-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 16000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINTENANCE AND REPLACEMENT OF LT AND APFC PANELS, SWITCHGEARS, SERVICE CABLES AND MISC WORKS AT PALAMPUR MIL STN.
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
2Returning filling in including spreading leveling watering and well ramming inlayers not exceeding 25 cm in any type of soil complete all as specified and directed.
3Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
4M&L sand cushioning to undergound cable with using fine river sand and gently punning for cushioning to cable complete all as specified and as directed. Note:-for the purpose of payment only punned thickness will be measured.
5S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable, including taking out old tubing complete all as specified and as directed.
6S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
7S&F 80mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,including taking out old tubing complete all as specified and as directed.
8Supply and fix in replacement Digital voltmeter in96x96 Sqmm three phase class 1.0including making necessary connection in existing panel complete all as specified and directed.
9Supply and fix in replacement Digitalammeterin96x96 Sqmm three phase class 1.0including making necessary connection in existing panel complete all as specified and directed.
10Supply and fix in replacementselector switch for voltmeter/ammeter including making necessary connection in existing panel complete all as specified and directed.
11Supply and fix in replacementneon indicator lamp with holder assembly RYB including making necessary connection in existing panel complete all as specified and directed.
12Supply and fix in replacementCT coil of existing capacity including making necessary connection in existing panel complete all as specified and directed.
13Cutting and removing existing wild grass,vegetation, creepers,small plants / bushes etc clamping up towards the poles and stays etc including cleaning bottom surface area of pole &stay not less than 1m x 1m by surface dressing of earth outside and inside substations, perimeter fencing around pump house area, and in drains surrounding area from site complete all as specified and directed by Engineer-in-charge.
14Supply and fix in replacement synthetic insulation mat 2m x 1m x 10mm (as per IS 15652-2006) complete all as specified and directed.
15M&L 20X15cm size LT danger notice plate of 1.60mm thick mild steel sheet,vitreous enamelled white,with letters,figures and conventional skull and bones in single red colour and fixed with M.S clamps,bolts and nutsincluding taking down existing rusted danger notice platecomplete all as specified and directed.
16Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 120sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed by Engineer-in-charge.
17Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 95sq.mm 3 1/2coreincluding taking out old unserviceable cable complete all as directed by Engineer-in-charge.
18Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 70sq.mm 3 1/2coreincluding taking out old unserviceable cable complete all as directed by Engineer-in-charge.
19Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 50sq.mm 3 1/2coreincluding taking out old unserviceable cable complete all as directed by Engineer-in-charge.
20M&L old size brick class "B" as in cable protection laid dry, flat, transversally along the length of cable on sand cushioning with width equalto length of the brickcomplete all as specified and as directed.
21Supply and fix in replacement MCCB, AC, 415 volts, 250 Amp, 35/36KA, 4 pole, adjustable thermal magnetic release including making necessary connection in existing panel complete all as specified and directed.
22Supply and fix in replacement MCCB, AC, 415 volts, 160 Amp, 35/36KA, 4 pole, adjustable thermal magnetic release including making necessary connection in existing panel complete all as specified and directed.
23Supply and fix in replacement MCCB, AC, 415volts, 125 Amp,16KA, 4 pole, adjustable thermal magnetic release including making necessary connection in existing panel complete all as specified and directed.
24Supply and fix in replacement MCCB, AC, 415volts, 100 Amp, 16KA, 4 pole, adjustable thermal magnetic release including making necessary connection in existing panel complete all as specified and directed.
25M&Lpreparation of existing old steel painted surface of panels of any size andany height , apply one coat of synthetic enamel paint inside and outside of panel (strictly existing shade) over a coat of red oxide zinc chrome primercomplete all as specified and directed.
26Taking down old un-serviceable panel of any specification,Supply, installation, commissioning and testing powder coated LT feeder pillar box outdoor type of size 0.90 mtr x0.50 mtrx 0.60 mtr factory fabricated made out of MS sheet of thickness 3.15 mm with front door openable with locking arrangement mounted on angle iron legs made out of angle iron size 40mm x40m x6mm , 1.0 mtr long, 0.50 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30 mtr x 0.30 mtr x0.50 mtr-04 nos, with 200 Amp rated copper bus bar LED phase indicating lamp, suitable for 3 phase 4 wire supply system with MCCB 125 Amp 4 pole breaking capacity 25 KA-01 No, duly drilled holes for cable connection mounted on epoxy based post insulators all as required at site, complete all as specified and directed.
27M&L welding existing broken panel doors (any number of shutters) and welding good quality hinges (any size any number of hinges per panel) of suitable size for making open and close the panel doors including bends etc and fixing locking arrangement of the doors complete all as specified and directed.
28M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead strip 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as directed by Engineer-in-charge. Note: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I., (ii) Item includes the cost of GI pipe up to 7.5m GI for protection of earth strip & (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
29M&Linspection, checking and repair of APFC panel by cleaning of dust inside with blower, cleaning of moving part/contract from CT cleaner, tightening of loose parts/electrical wiring , cleaning of contractors, relays and capacitor juction points, oiling of cooling fan , complete testing of APFC relay with necessary settings with CTs /load adjustments to match with the APFC load management systemcomplete with replacement of burnt/worn out unserviceable components /burnt wires thimbles /lugs etc for APFC panel capacity 50 KVAR to 150 KVAR completeall as specified and directed. Note : All unserviceable parts shall be measured and paid seperately as supply only. Replacement of small nuts/screws, wires lugs or thimbles and cleaning material cost included in this item.
30SupplyonlyMCB, TP 6 to 32 Amp 10 KA C curve 415 volts complete all as specified and directed.
31SupplyonlyMCB, TP 40 to 63 Amp 10 KA C curve 415 volts complete all as specified and directed.
32Supplyonly Auxillary contractor 1 NO+1NC TP 415 volts suitable for 10 KVAR rating complete all as specified and directed.
33Supplyonly Auxillary contractor 1 NO+1NC TP 415 volts suitable for 20 KVAR rating complete all as specified and directed.
34Supplyonly capacitor 440 volts 50 Hz5 KVAR complete all as specified and directed.
35Supplyonly capacitor 440 volts 50 Hz 10 KVAR complete all as specified and directed.
36Supplyonly capacitor 440 volts 50 Hz 15 KVAR complete all as specified and directed.
37Supplyonly capacitor 440 volts 50 Hz 20 KVAR complete all as specified and directed.
38Supplyonly CT"s suitable for Ampere meter 100/5A ratio complete all as specified and directed.
39Supplyonly CT"s suitable for Ampere meter 200/5A ratio complete all as specified and directed.
40Supplyonly APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 6 stages complete all as specified and directed.
41Supplyonly APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 8 stages complete all as specified and directed.
42SupplyonlyMCCB, AC , 415volts,100 Amp, 25KA, 4 pole, fixed thermal magnetic release complete all as specified and directed.
43SupplyonlyMCCB, AC, 415volts, 160 Amp, 25KA, 4 pole, fixed thermal magnetic release complete all as specified and directed.