Department of Defence Production has published Bids Are Invited For Serviceability Checks / Overhaul Of Electronic Equipment - ( A ) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. ( B ) Check Connectors For Proper Mating And Grounding. ( C ) Clean All Pcbs /. Submission Date for this Tender is 17-02-2022. Wrenches and Drivers Tenders in Goa. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Jan-2022 | 11-01-2022 | ||
2 | 11-Jan-2022 | 14-01-2022 | ||
3 | 07-Feb-2022 | 11-02-2022 | ||
4 | 10-Feb-2022 | 17-02-2022 |
Sl. No. | Item Title | Item Description |
1 | Serviceability checks/ overhaul of Electronic equipment | (a) Clean dust, dirt and moisture from the internal and external surface of the units. (b) Check connectors for proper mating and grounding. (c) clean all PCBs/ modules and check for correct functionality. procure and renew if faulty. (d) SMPS/ power supply unit to be checked for rated input/ outputs. renew if faulty. (e) Systems having software to be checked for correct functionality. (f) Check the cable and connectors for cuts, corrosion or undue strain. (g) Clean the air filter with vacuum cleaner as applicable. (h) Check the set for optimum/ designed performance and reliability. (j) Replace the defective lamps/caps/ fuses/ hinges/ screws/ knobs/ keys/ switches. (k) All existing shock mounts / base plates / foundations to be checked for integrity and renew if necessary. (l)Renew all earthing/ bonding straps. (m) Renew all terminal lugs (n) Renew of EMI/ EMC gaskets of all openings of equipment. (p)interfacing to all systems to be proved as applicable. (q) Carry out all Annual routines and performances tests as per Maintop at shop floor |
2 | post overhaul/ serviceability checks | Post overhaul /repair/ routines following to be carried out:- (a) All systems/ equipments/ machinary should be proved to rated/designed power /capacity without limitations /observations and trials to be offered to the naval trial agencies for design specifications along with installation inspections as per approved WLDs, Op checks, HATs and SATs. (b) Any unserviceability during undertaking above serial needs to be repaired / renewed by firm inclusive of spares. (c)Vibration levels at all points should be less than 5 mm/sec.The equipment performance will be considered satisfactory only if the performance trials are cleared by naval inspection agency. (d) Present system for HATS and SATS as per the standards of WATT. |
3 | overhaul of antennas and aerials | (a) clean and examine Whip and wire aerials for pitting /cavities, replace all defcetive components. apply RF paint to antennas. (b) Check insulation of wire Aerial, Value should be more than 2 mega ohms,if strands are cut/ broken to be replaced. (c) Renew Porcelean Insulators of Wire Aerial if required. (d) Replace insulator of Antenna if defective (e)Base plate of Antenna is corrodedto be manufactured and fitted. (f)work includes removal/refitment of Antenna. (g) Antenna foundation box is corroded,to be removed and new box as per original dimensions to be manufactured and fitted/ welded on the respective antenna place. |
4 | V/UHF Search RX ELK-7036 (I) | Make : BEL HYDModel : V/UHF Search RX ELK-7036 Serial No : 704101580010 OEM"s Local Representative : M/S BEL, Hyderabad Other Details( N/A ) : Power Cons -1.1 KVA,Receiver Frequency Range( KHZ ) : 20-1250 MHZ,Supply Frequency( HZ ) : 45-65,Supply Phase( Ph ) : 01,Supply Voltage( Volts ) : 90-240 |
5 | V/UHF Search RX ELK-7036 (II) | Overhauling of complete system as per SOW 3. |
6 | V/UHF Search RX ELK-7036 (III) | Overhauling of Antenna as per SOW 5 |
7 | V/UHF Search RX ELK-7036 (IV) | Post overhaul/ serviceability checks as per SOW 4. |
8 | Sanket MK II (MT-73112) | Make: BEL,Hydrabad Model: MK OEM"s Local Representative: M/s BEL,Hydrabad (a) Check the RF and Video tangential signal sensitivity at AHU output in normal mode by feeding the RF signal at AHU using RF generator. |
9 | 1 (Sanket MK II (MT-73112)) | (b) Check the DC offset Volttages for each FER Chennel and ensure that the DC Offset Voltage is within Specified Limit using test Equipment. |
10 | 2 (Sanket MK II (MT-73112)) | (c) Open the AHU back cover and inspect all the semi-rigid cables for intactness.Ensure that they are tightened properly using torque wrench. |
11 | 3 (Sanket MK II (MT-73112)) | (d) Carry out level-2 maintenance which includes repair of PCBs, replacment of components and sub assemblies in the shop floor. |
12 | 4 (Sanket MK II (MT-73112)) | (e) Inspect the EW cables run of both normal and Co-oxial wire for intactness and continuty. |
13 | 5 (Sanket MK II (MT-73112)) | (f) Replace the Gaskets with new set and apply grees before closing the unit covers wherever applicable. |
14 | 6 (Sanket MK II (MT-73112)) | (g) Remove the radomes, clean and stow them safely. |
15 | 7 (Sanket MK II (MT-73112)) | (h) Overhaul/ Serviceability checks of full system to be carried out as per SOW 3. Procure and replace all faulty components by refitting yard. |
16 | 8 (Sanket MK II (MT-73112)) | (j) Carry out complete performance checks of the system. |
17 | 9 (Sanket MK II (MT-73112)) | (k) Carry out the HATs schedules as per SOW 4 and ensure that the system is functioning satisfactory. |
18 | 10 (Sanket MK II (MT-73112)) | (l) Carry out calibration/ servicing/repair of PCBs, connectors and sub asseblies as applicable.Obtain OEM assistance if necessory |
19 | Mandotary spares 1 (EB3050B-172200061696) | CPU Card |
20 | 2 (EB3050B-172200061795) | Synthesizer card assy |
21 | 3 (EB3050B-172200061987) | Iner face card assy |
22 | 4 (EB3050B-457672630186) | PC Power Supply |
23 | 5 (EB3050B-480578080109) | Hard Disk |
24 | 6 (EB3050B-480672300186) | KEYBOARD DRAWER |
25 | 1(NA) | 3 KVA Online UPS |
26 | 2 (NA) | 12V, 42 AHBATTERY |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy