Providing Lwss Pc_Fc Habitation From Dwaru Khad To Bindla In Tehsil Karsog Distt Mandi Hp Sh_Laying Jointing And Testing Of Rising Main And Supplying And Installation Of Centrifugal Pumping Machinery With Allied Accessories Ist Stage
Tender Overview
Project Description
Providing Lwss Pc_Fc Habitation From Dwaru Khad To Bindla In Tehsil Karsog Distt Mandi Hp Sh_Laying Jointing And Testing Of Rising Main And Supplying And Installation Of Centrifugal Pumping Machinery With Allied Accessories Ist Stage
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil includingbailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides,leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testingof pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoitedlayer by ramming & watering & then disposing of all surplus excavated soil /unusablematerial as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversionfor traffic, night signals, fixing caution boards, crossingover trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-Charge. |
| 2 | Laying, jointing and testing in trenches to grade IS marked GI flanged pipe of the following diameter conforming to IS 1239 (part-II) latest with upto date ammandments having nominal thickness as forclass of pipe soecified below jointed with flanges confirming to tables as specified belowof BIS 6392-1971(with latest upto date amendments) welded at boyh ends according to relevant BIS standrdsand detaild specification as specified in NIT & provided along with nuts and boltsof required sizes, 3 mm thick compressed asbestos fiber/ synthetic rubber gasket confirming to relevant BIS codes as givenintechnick specificationi/c all kinds of leads 7 lifts flanged short pieces, bends, tees & other specials etcs. made from parents tubes & welded with flanges of tables as applicable for the particular reach & of technical specification appended in the NIT as per site conditions including flushing & hydraulic testing as per directionof Engineer in charge. |
| 3 | RDs 1st stage from to LengthDia ClassFlanged Table. 0 30030065Heavy 285% of flange joints |
| 4 | RDs 1st stage from toLengthDia Class Flanged Table. 3001000 700 65Medium28 5% of flange joints |
| 5 | RDs 1st stage from toLengthDia ClassFlanged Table. 10001500 500 65Medium5 5% of flange joints |
| 6 | Laying, jointing and testing ofGMS Pipebevelled edged conforming to IS:1239 of following size and class in trenches havingrandom lengths of 5-7 mtrs including cost of fabrication of minimum 3 cut bends of required degree. The pipe shall have inside & out side Galvanisation at manufacturer work conforming to IS:4736 (with upto date ammendments). The pipe shall be jointed withcircumferencialbuttweldedjointsby electric arc welding with minimum three layers of welds so as to achive the minimum effective thorat thickness and strength of welds conforming to IS: 816-1969 sepecification, by using welding electrodes of 2.50 mm to 6.30 mm of Advani Oerlikon (Ador)- CITOJET / Esab make, conforming to IS:814-1991, at site of work complete in all respects. Each butt welded joint shall be tested with dye-penetration test ( with the kit consisting of 3 sprays of 250 ML each includes (a) Cleaner CL-96 (b) Penetrant PT-97 (c) Developer Div-98 of checkmate make) complete in all respects, including manual / mechanical handling of pipes in all leads and lifts to the entire satisfication of Engineer-in-charge. (The earth work in trechesand cost of MS flanges to be measured and paid for separately) |
| 7 | RDs 1st stage from to LengthDia ClassFlanged Table. 0 30030065Heavy 2895% of flange joints |
| 8 | RDs 1st stage from toLengthDia Class Flanged Table. 3001000 700 65Medium28 95% of flange joints |
| 9 | RDs 1st stage from toLengthDia Class Flanged Table. 10001500 500 65Medium595% of flange joints |
| 10 | Supply & Installation of Centrifugal Pumping Machinery with allied accessories 1st StageProviding of horizontal spindle,horizontal/redial split casing/end suction (backpull out arrangement)Single/double/Multistage centrifugal pumps or combination of pumps,.in series/parallel of recommended make such as KSB/Mather & Platt/Kirloskar /Beaconweir/BE / Grundfos pump/LUBI Pump as perBIS 1520-1980 with upto date ammendments) read with IS 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze ,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade------- with cast iron casing coupled directely through a flexible coupling on a common CI/cast steel base plate(base plate to be from the manufacturer of the pumping unit only) to slip ring/squirrel cage screen protected drip proof induction motor/motors of standard make such askirlokar/BHEL/NGEF/GEC/Crompton/ Siemen/Marthon/ABBand suitable for operation on 415(+/-)5% volts,50 cycles/second ,3 phase AC electric supply. The power of electric motor/motors should be at least +15% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and(-) 15% of the duty point head.The motor/motors as per IS: 325-1978 with upto date ammendments read with IS: 900-1972. It should include cost of bearing ,nuts,bolts and painting etc. and should meet the following requirements:- |
| 11 | (A).SITE CONDITION :- (i) Location of Site About 18 Km fromChurag:- Near Village Dawaru (ii) The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mt:- 750 Mtrs (iii)Humidity:- Weather generally remains humid during monsoon Season. (iv) Nature of Atmosphare:-As normally encountered in Shivalik Range. (v) Detail of quality of water:-Clear cold water. (vi) Water free from sand or not:- Yes. (vii) Water corosive or not:-Not. (viii) Turbidity (if any):-Clear Cold WATER. (ix) NPSH available:-8.994 Mts. (x) Any other information or requirement. |
| 12 | (B). OPERATING CONDITIONS :- (i) Typeof current:- AC three/single phase. (ii) Operating frequency:- 50 HZ. (iii) Rated voltage:-400 (+/-) 10% volts. (iv) System of earthing if any to be adopted:-Double loop earthing as per BIS 3043-1987 latest with upto date ammendments. (v) No. of working hours per day :- 6 hours. (vi) Speed of revolution in RPM:- To be quoted by tenderer. (vii) Direction of rotation:-To be quoted by tenderer. (viii) The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 25 degree centigrade. |
| 13 | (C). MOTOR :- (i) Ref to BIS code:-BIS 325- 1978 read with BIS 900-1992 (latest) with upto date ammendments. (ii) Type of enclosure of motor:-SPDP (as per BIS 4691-1985 (Latest). (iii) Type of duty:-Continuous. (iv) Mechanical out put in KW:-suitable for driving centrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. (v) Class of insulation:-Class- B. (vi) Max. permissible temp. rise of motor reqd. if different from given in B (viii) above. (vii) Particulars of test reqd. & where they are to be conducted:-As per terms & conditions. (viii) Particulars as to whether voltage limiting device will be employed:-ATS/star delta starter oil immersed fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site.NOTE :- Star delta starter upto 37.5 KW. ATS between 37.5 KW to 50 KW & Stator rotor starter with slip ring motor beyond 50 KW. (ix) Motor whether squirrel cage or slipring:- Squirrel cage/slipring. Note :- Squirrel cage upto 65HP and slipring above 65 HP. (x) Detailsof shaft extension reqd:- Just sufficient to provide direct drive by flexible coupling to pump. |
| 14 | (xi) Type of slip ring gear whether continously rated or for starting puposes only & whether to be fitted with brush lifting or short circuiting arrangements or bothe if interlocks are required.:-Continously rated for squirrel cage/ slipring motor. (xii) Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in curcuit:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.(xiii) Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated& No. of starts during a specified period:- To work the pumps offered. (xiv) Where possible fault capacity of the systemto which the motor is connected:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent defomations. |
| 15 | (D). PUMP (BIS 1520-1980) read with BIS 9137-1978 both latest with upto date ammendemnts :- (i) Nosof pumps reqd:-1 Nos. working pumps & 1 No. stand bye. (ii) Spare parts required:- For two years normal maintenance as recommended by manufacturer. (iii) Optional fittings reqd:-Air cock for exahausting air from each stage. |
| 16 | (E).PUMP OPERATING CONDITIONS :- (i) Capacity:-2.40 LPS. (ii) Total head in Mts.:- 292.7mtrs. (If total head is not known then follwing details be provided :- a)static Head: 260.5 mtrs, (b) Minimum depth of water: --------mtrs. (c) Variation in water level: ----- mtrs. (d) Ground level mex. Water level: 750 mtrs. (e) Ground level to delivery point: 1110.5 mtrs. (f) Pressure in the suction tank: ------ Kg/cm^2 (g) Pressure in the delivery tank: ------ Kg/cm^2 (h) Length of Rising main: 1550 mtrs.) (iii) Dia of R/main:65mm. (iv) Drive arrangement:Direct through flexible coupling on a common base plate.(v) Drive type:-Electric driven. (vi) NPSH reqd:-To be quoted by the tenderer. (vii) Limits of total head in which the pump is reqd. to operate:-(-) 25% to (+) 10% of total head. (viii) Suction/delivery size of pump:-To be specified by the tenderer. (ix) Efficiency of pump at a)duty head,b) (+) 10% head,c) (-) 25 % head:-To be specified by the tenderer. (x) Material of construction:-To be specified by the tenderer (Manufacturer certificate to be appended). |
| 17 | Suply of suitableoil immeresd Star Delta Starter/ATS/stator Rotor Starter ofstandard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with initial oil filling. Note:- Star- delta - starter upto 37.5 KW. ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50KW. |
| 18 | Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections.The drawing of panel board shall be subject to approval of Engineer-in-Charge. |
| 19 | Ammeter AC supply, 100mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selectro switches conforming to BIS 1248-1983 latest with upto date ammendments. |
| 20 | Voltmeter A.C. Supply, 100mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor withselectro switches conforming to BIS 4064-1978 with upto date ammendments. |
| 21 | ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. |
| 22 | Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and11353-1985 read with 5578-1985 all latest with upto date amamendments. |
| 23 | MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. |
| 24 | 3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments. |
| 25 | Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitablerange with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tapeCTS.It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side. |
| 26 | Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations. |
| 27 | Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference. |
| 28 | Change over switch of reputed make & suitable capacity. |
| 29 | Single phase preventor of reputed make & suitable cacpacity. |
| 30 | Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast iron/cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of ASA 300 nominal seat pressure 52 Kg/cm^² NOTE:-The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600) |
| 31 | Supply of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast iron/Cast Steel double flanged swing check type reflux valve having bye pas arrangement &size equal to delivery of Pump for withstanding nominal seat pressure of 52Kg/cm^ ² ASA 300 NOTE:-The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 52 Kg/Cm²) as per BS 1414 (API 300) |
| 32 | Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/Bhel/Leader of suitable size Cast Iron/Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^²NOTE:-The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^²) or class 300 ASA (Seat pressure 52 Kg/cm^² or class 600 ASA (Seat pressure 104 Kg/Cm²) as per BS 1414 (API 600) |
| 33 | Supply of Kirloskar/Kilburn/IVC/Fouress/Glad/BHEL/Leader/of reputed make of suitable size cast iron flanged sluice valve confirming to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap. |
| 34 | Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conformingto BIS 4038-1986 or latest with upto date ammendments. |
| 35 | P/L suitable size copper pVC insulated armoured power 31/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phase) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor.The type size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. |
| 36 | Providing layingsuitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes,solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor.The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. |
| 37 | P/L double loop earthing with GI plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring& 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment. |
| 38 | Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.) |
| 39 | Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments. |
| 40 | Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pumpincluding tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge.The pipes shall be capable of with standing 1.5 times the total pressure indicated in item No. 1e(ii). Note :- Actual laying to be done as per final drawings to be approved by the Engineer-in-Charge. |
| 41 | Errection of all equipments i/c cost of tees, bends tapers and any other fittings required as per site conditions and as per directions of Engineer-in-Charge. |
| 42 | Errection of all equipments from S.No. 1 to 4, 6 & 8i/c cost of tees, bends tapers & anyother fittings required as per site conditions& as per directions of Engineer-in-Charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender