Construction Of Pre-Fab Structure At 4Th Floor In Police Headquarter Building Sector 6, Panchkula Construction Of Pre-Fab Structure At 4Th Floor In Police Headquarter Building Sector 6, Panchkula, Panchkula-Haryana

Haryana Police Housing Corporation Limited has published Construction Of Pre-Fab Structure At 4Th Floor In Police Headquarter Building Sector 6, Panchkula Construction Of Pre-Fab Structure At 4Th Floor In Police Headquarter Building Sector 6, Panchkula. Submission Date for this Tender is 06-01-2022. Structural Work Tenders in Panchkula Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

30417741
Construction Of Pre-Fab Structure At 4Th Floor In Police Headquarter Building Sector 6, Panchkula Construction Of Pre-Fab Structure At 4Th Floor In Police Headquarter Building Sector 6, Panchkula
Open Tender
Indian
Haryana
Panchkula
06-01-2022

Tender Details

Construction Of Pre-Fab Structure At 4Th Floor In Police Headquarter Building Sector 6, Panchkula Construction Of Pre-Fab Structure At 4Th Floor In Police Headquarter Building Sector 6, Panchkula

Key Value

Document Fees
INR 5000 /-
EMD
INR 172000.0 /-
Tender Value
INR 85.73 Lakhs /-

BOQ Items

Name of Work: Construction of Pre-fab structure at 4th floor in Police Headquarter Building Sector 6, Panchkula
Sl. No. Item Description
1By Mechanical Transport including loading, unloading and stacking HSR 3.1
23.1.1 Lime, moorum, building rubbish Note:- these rates are exclusive of Contractor profit and overhead as well as GST, lead upto 5Km i.e Rs. 74. Now the rate including GST + Contractor Profit Rs. 74+18%+15% = Rs. 100.04 Say Rs. 100
3b) Earth Work. Note:- these rates are exclusive of Contractor profit and overhead as well as GST, lead upto 5Km i.e Rs. 93. Now the rate including GST + Contractor Profit Rs. 93+18%+15% = Rs. 126.20 Say Rs. 126.20
4Demolishingbrickworkmanually/bymechanical means includingstackingofserviceablematerialanddisposalof unserviceable material within 50 metres lead as per direction of Engineer-in-charge. HSR 5.7.
55.7.4 In cement mortar
6Demolishing mud phaska in terracing and disposal of material within 50 metres lead. HSR 5.11.
7Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. HSR 5.14.
8Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. HSR 5.23.
95.23.2 Nominal concrete 1 :2:4 or leaner mix (i/c equivalent cum design mix)
10Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. HSR 5.27.
11Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. HSR 5.45.
12Providing and laying cement concrete in retaining walls, return walls,walls(anythickness)includingattachedpilasters, columns,piers,abutments,pillars,posts,struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor fourlevel,excludingthecostofcentering,shutteringand finishing: HSR 6.2.
136.2.4 stone aggregate 20 mm nominal size) 1:5:10 (1 cement : 5 coarse sand (zone-Ill) : 10 graded stone aggregate 40 mm nominal size).
14Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). HSR 6.16.
15Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. HSR 6.34.
16Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
176.34.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
18Half brick masonry with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level. HSR 7.28.
197.28.2Cement mortar1 :4 (1 cement :4 coarse sand)
20Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand 4 stone aggregate 10 mm and down gauge),including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard designHSR 9.17.
219.17.1 In 75x75 mm deep chase
22Providing and fixing tiled false ceiling of specified materials of size 595x595 in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. HSR 9.47.
239.47.1 GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
24Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing "C" wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm centre to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1 .6 mm, rawl plugs of size 38x12 and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centres with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with: HSR 9.49.
259.49.1. GI Metal Ceiling Clip in plain Bevelled edge global white colour tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after
26Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping.HSR 10.4.
27Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. HSR 10.50.
2810.50.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
29Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. HSR 10.57.
30Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR 10.62.
31Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. HSR 10.63.
3210.63.2 Size of Tile 600x600 mm
33Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. HSR 10.67.
3410.67.2 Size of Tile 600x600 mm
35Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. HSR 10.70. Derived Rate 523.33
3610.70.2 Size of Tile 600x600 mm Derived Rate
37Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. HSR 10.106-10.72 Derived rate
3815 mm cement plaster on the rough side of single or half brick wall of mix : HSR 11.6.
3911.6.2 1 :6 (1 cement: 6 fine sand)
40112 mm cement plaster of mix : HSR 11.8.
4111.8.1 1 :4 (1 cement: 4 coarse sand)
4211.8.2 1 :6 (1 cement: 6 coarse sand)
43Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58.
44Distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. HSR 11.65.
4511.65.1 Two or more coats on new work
46Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: HSR 11.67.
4711.67.1 Water thinnable cement primer
48Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR 11.77.
49Painting over the wooden surface with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade HSR 11.83.
5011.83.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
51Finishing walls with Acrylic Smooth exterior paint of required shade HSR 1..95.
5211.95.1 New work (Two or more coat applied @ 1.67 litre/1 O sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
53Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. HSR 12.36.
5412.36.1 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws
55Providing and fixing pressed steel door frames conforming to IS: 4351, manufacturedfromcommercialmildsteel sheetof2.0mmthickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: HSR 13.3.
5613.3.2 Profile C
5713.3.2.1 Fixing with adjustable lugs with split end tail to each jamb
58Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. HSR 13.30.
5913.30.2 Hot finished seamless type tubes
60Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. HSR 13.31.
61Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required HSR 22.10.
6222.10.1 Kitchen sink with drain board
6322.10.1.1 510x1040 mm bowl depth 250 mm
64Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. HSR 22.14.
6522.14.2 Flexible pipe
6622.14.2.2 40 mm dia
67Providing and fixing white vitreous chinaware pedestal type (European type/ wash down type) water closet pan. HSR 22.30.
68Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. HSR 22.39.
6922.39.1 10 litre capacity - White
70Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from backside,includingfixingtowallwithsuitable brackets all as per manufacturers specification and direction of Engineer-in-charge. HSR 22.46.
71Providing and fixing partitions for different type of urinals. HSR 22.50.
7222.50.1 Vitreous Chinaware Partition plate.
7322.50.1.2 Large size 835mm x 355 mm
7422.50.1.2.1 White
75Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benching 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. HSR 22.84.
7621.84.2 Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern Iweighing 38 kg with C.C. topping)
77Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. HSR 22.86.
7822.86.1 15 mm nominal outer dia Pipes
7922.86.2 20 mm nominal outer dia Pipes
80Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. HSR 22.105.
8122.105.1 15 mm nominal bore
82Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. HSR 22.106.
8322.106.1 15 mm nominal bore
84Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. HSR 22.107.
8522.107.1 15 mm nominal bore
86Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 HSR 22.108.
8722.108.1 15mm nominal bore
88Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: HSR 22.166.
8922.166.1 100x100 mm size P type
9022.166.1.1 With common burnt clay non-modular bricks of class designation 7 .5
91Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181.
92Labour only for fixing in position mild steel storage tanks (to be supplied by the Engineer-in-charge-Ex-Store) including hoisting etc. and carriage from store to site of work complete with providing and fixing and 15 mm or 20 mm internal diameter flanges for inlet and outlet. 25 mm for overflow and 40 mm for scour pipe including 25 mm brass perforated mosquito proof cap for overflow and plug for scour pipe and labour for making pipe connections and small masonry supports on the top of the roof where these tanks are to be fixed complete in all respects including cutting and making good the walls andfloors etc. HSR 22.183.
9322.183.2 Tank made out of 3.00 mm thick plates with 40 mm x 40 mm angle iron frame : -
9422.183.2.3 More than 910 litres capacity
95Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. HSR 22.209.
96Providing and fixing SWR PVC pipe Type B of approved make complete to the Entire Satisfacation of Engineer in Charge complete in all respect. HSR 22.222.
9722.222.2 Single Socket Type B
9822.222.2.2 110mm old SWR UPVC pipe lines laid complete
9922.222.2.3 90mm old SWR UPVC pipe lines laid complete
100Providing and applying waterproofmg treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achievea minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : >400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : >50 N as per ASTM C- 836 Recovery from 350% elongation : 95% as per ASTM D 412 Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr Initial Hardness Shore A : min 60 as per ASTM D 2240 Root resistant : protection screed required System indudes supply , application and termination of coating all complete as per the manufacturer"s methodology. Clean the RCC slab/screed surface & wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer"s recommendations. Prepare a side gola of 50X50 mm at the junction using polymer modified mortar. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre lothffleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above FFI by providing a groove cut of 30mm x 30mm & seal it with shrinkage compensated polymer modified mortar. Lay a 150 GSM geotextile layer to protect the coating from external damage on final coating before laying of screed concrete/final finish. It shall be applied as per manufactures specification. Rates are ind of surface preparation, grouting and chemical application only. (Rates for geotextile, protection plaster and final finishes such as screed or Brick bat filling for slope, china mosaic, tiles etc is not included in above item. It will be added as per EIC requirements). WATERPROOFING TREATMENT TO TERRACE AREA USING TWO COMPONENT 100% SOLIDS HYBRID POLYUREA COATING HSR 28.6.
101Providing and laying cinder concrete in cement 1 :15 (1 cement and 15 cinder) on terraced roofs &(up to threeStoreys), laid to slope, including consolidating the same. HSR 28.27.
102Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade HSR 30.28.
10330.28.1 One or more coats on old work
104Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness up to 6" (six inches) for passing drain pipe and repairing the hole after insertion of drain pipe etc. including finishing-complete so as to make it leak proof. HSR 30.82.
10530.82.1 Drain pipe of 150mm internal dia
10630.82.2 Drain pipe of 100mm internal dia
107Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials HSR 31.14.
10831.14.5 20mm dia (hole size 24 mm dia & depthup to 240mm)
109HSR Total
110NS Items
111Providing and fixing of 50mm thick PUF insulated Wall Panel with 0.50mm thick PPGI sheet (Make JSW) (Ral-9002) both sides, with FR Grade PUF Density 44Kg/m3 + 10% in metallic tongue and Groove joint system, cut to size, with no loading of wastage with additional 90° bends in Male & Female groove to have proper sealing, Strength & Air Tight joints Panel to Panel, CFC free & Ozone friendly, complete with top bottom U Channel, Inner and Outer flashing complete with filling of joints with Silicone sealent alongwith taping to protect from water seepage and complete arrangment of providing and fixing of required size hilti make fastner as per design and drawing complete in all respect to the entire satisfaction of engineer in-charge of the work. NS Item
112Providing and fixing of 65/35mm puf insulated Roof panel with 0.50mm thick corrugated profile sheet from outside and light grooved 0.50mm thick PPGI inside with FR Grade PUF Density 44 Kg/m3 +10% with proper overlapping and projections on all sides complete with all accessories like L-Flashing & Roof edge covering channels complete with filling of joints with Silicone sealent alongwith taping to protect from water seepage as per design and drawing complete in all respect to the entire satisfaction of engineer in-charge of the work. NS Item
113Providing and fixing of Puf Insulated Doors with 40mm thick leaf and powder coated chowkhat complete with powder coated aluminium accessories like Hinge, Tower Bolts, Handles, Areal Drop, Door stopper, Door Closer of ISI marked as per design and drawing complete in all respect to the entire satisfaction of engineer in-charge of the work. (Make Classic, Grace). NS Item
114Door Size - 750 x 2100mm(3 Nos), Door Size - 900 x 2100mm(2 Nos), Door Size - 1000 x 2100mm(6 Nos), Door Size - 1200 x 2100mm(1 Nos)
115Powder coated aluminium sliding Windows of size 1175x1175mm with 5mm Glass, wire mesh and Grill outside duly powder coated complete in all respect using Rollers, EPDM Gasket, Locking arrangements, handle, tower bolts of suitable size with powder coated of ISI marked as per design and drawing complete in all respect to the entire satisfaction of engineer in-charge of the work. (Make Classic, Grace) NS Item
116Ventilators aluminium powder coated of size 450x600mm with provision for exhaust fan for wash rooms, pantry and cooking area with powder coated necessary fittings such as tower bolt, handle of ISI marked as per design and drawing complete in all respect to the entire satisfaction of engineer in-charge of the work. (Make Classic, Grace) NS Item
117Providing and fixing Under counter Basin oval size size 195 x 600 x 425 as per design and drawing complete in all respect to the entire satisfaction of engineer in-charge of the work. NS Item
118Providing and fixingHealth Fauct complete to the entire satisfacation of Engineer in Charge complete in all respect. NS Item
119Providing and fixing Toilet ring round AQN-7721(Jaquar make)complete in all respectto the entire satisfaction of Engineer in Charge. NS item
120Providing and fixing ACN-1131 N Soap Dish Holder(Jaquar make) Complete in all respectto the entire satisfaction of Engineer in Charge. NS Item
121Prividing and fixing Soap Dispenser SDR-WHT DJ 0010F/115 complete in all respectto the entire satisfaction of Engineer in Charge. NS item
122Providing and fixing SWR PVC pipe Specials of approved make complete to the Entire Satisfacation of Engineer in Charge complete in all respect. NS item
123a) 110mm dia
124i) Bend
125ii) Socket
126b) 90mm dia
127i) Bend
128ii) Socket
129ii) Floor trap
130Providing and fixing in position CP jali of heavy quality of approved make completeto the entire satisfacation of Engineer in Charge complete in all respect. NS Item
131Providing,fixing and jointing CPVC union couplings in CPVC pipelines complete in all respectto the entire satisfaction of Engineer in Charge. NS Item
13215 mm dia
13320 mm dia
134Providing, fixing and jointing of CPVC Gate valve on CPVC pipelines complete in all respect to the entire satisfaction of Engineer in Charge. NS Item
13515 mm dia
13620 mm dia
137Expansion Joint Treatment with 65mm width :- Cleaning of surface and make it for Dust Free. Any repair for edges of expansion joint will be done with Sand and cement. Providing and fixing of Thermo Plastic Elastomer Tape(TPE Tape) width 150 mm and thickness 1 mm designed for water tightness of expansion joint. The TPE Tape Should is applied with help of suitable epoxy Adhesive. Place the tape over the adhesive in such a way that 10mm adhesive remained exposed .Press the tape slightly to ensure good adhesion. Then Apply 2nd coat of Epoxy adhesive on the tape. The epoxy adhesive consumption will be 1.5kg per RMT The TPE Tape should have following properties : a. Elongation at Break >400% b. Tear strength >25Kn/m c. Adhesion By epoxy >52 N d. Tensile Strength >5 e. Chemical Para meter : Resistance to Water, Sea Water, Waste Water,UV Radiation, Microorganisms, Acids, Alkalis f. pH resistance: pH = 2 to 10 (Below 30degree temp.), 25to 10 (Below 40degree temp.) After fixing of TPE Tape, Apply Aluminum expansion joint plate on the ground level. The Aluminum plate will be width of 150 mm. The plate should be one side fixed with help of screws and other side loosely laid. Filling of PU sealant on edge of Aluminum Plate Make of TPE Tape : Asian Paints/ Surperma/Terramco as per design and drawing complete in all respect to the entire satisfaction of engineer in-charge of the work. NS item
138Removing and refixing of existing MS Step Ladder complete in all respectto the entire satisfaction of Engineer in Charge. NS item
139Total NS
140Credit of Old material.
141The recovery of dismantled material stacking on GF of construction site, the transportation charges including loading, unloading and carriage born by the agency his own level from GF to any lead and lift
142Taking 60% of good bricks
143Taking 40% of Brick bats as per HSR B0146
144Total
145E.I HSR
146Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated copper conductor cable 1100 volts grade in PVC conduit etc as required. (Rate are reduced by 15% for surface wiring) (HSR 23.3.6.)
14723.3.6.1.)1 run of size 1.50sqmm (1/1.40mm)
14823.3.6.2.) 1 run of size 2.50sqmm (1/1.80mm)
14923.3.6.3.) 1 run of size 4sqmm (1/2.24mm)
150Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe(Rate are reduced by 15% for surface wiring) (HSR 23.4.1.)
15123.4.1.1) Group A
152Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch.(Rate are reduced by 15% for surface wiring) (HSR 23.4.3.)
15323.4.3.1.) Group A
154Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required,.(Rate are reduced by 15% for surface wiring) (HSR 23.4.4.)
15523.4.4.1) Group A
156Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required.(Rate are reduced by 15% for surface wiring) (HSR 23.4.5.)
15723.4.5.1) Group A
158Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 23.8.11.)
15923.8.11.1.) 5 amp 1 way switch
16023.8.11.3.)15 amp 1 way switch
16123.8.11.4.) 5 amp socket
16223.8.11.5.)15 amp 6 pin socket
16323.8.11.6.) Bell Push
16423.8.11.7.) step type Fan regulator 2 modules 300 watt
16523.8.11.8) Telephone Socket outlet modular type
16623.8.11.10.) Blinking plate
16723.8.11.11) RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type
168Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 23.22.1.)
16923.22.1.4) TRIPLE POLE MCCB 125 to 160 Amp, 25 KA
170MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings(HSR 23.22.2.)
17123.22.2.1)MCCB up to 125 A FP
172Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. (HSR 23.22.4.)
17323.22.4.9) Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
174Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- (HSR 23.22.5.)
17523.22.5.1) 6 amp. to 32 amp Single Pole
17623.22.5.6) 40 amp to 63 amp. MCB"s TRIPLE POLE
177Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. (HSR 23.23.8.)
17823.23.8.1) 2 pair telephone wire
179Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required. (HSR 23.23.9.)
180Earthing and lightening arrestor (HSR 24.1.)
18124.1.4.) Earthing with tinned copper earth plate 6D0mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required
18224.1.5.) Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode
18324.1.9.) Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required
18424.1.10.)Providing and fixing 25 mm x5 mm copper strip on surface or in recess for connections etc. as required with all labour and material.
185Laying and fixing of cable on surface/ cable tray etc as required:-(HSR 24.2.5.)
18624.2.5.2) 16 Sq mm to 35 sqmm 2 to 4 Core
187Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. (HSR 20.71.)
18820.71.1) 48" (1200mm)
189Total (HSR + CP ) Amount
190NS Items
191S/E PVC pipe ISI Marked heavy guage i/c bendinspection box etc., i/c laying of pipe in slab or wall complete with all patty material required to complete the job in all respect.(Recessed type)
192ii)Size 25 mm dia (Recessed Type)
193ii)Size 25 mm dia (Surface type)
194S/E of copper refrigerant pipe with insulationwith labour etc.
195Supply and Erection of PVC hard Drain Pipe of 25 mm dia including PVC Tee, Elbow, Etc.
196Supply and Installation of PVC flexible pipe 2" dia for covering copper referigerent pipe
197Re-Installation of 1.5 ton/ 2.0 Ton Split A.C. complete in all respect
198Dismantling of Old A.C.1.5 / 2.0 Ton complete in all respect
199Supply and erection of M.K accessories complete in all respect. (white colour)
200i) PVC Commercial dado trunking of size 100mm x 50 mm NCT 1050
201S/E of PVC Batten / Channel with all petty material like rawal plug , wooden / steel, screws etc. (ISI marked)
202ii) 25mmx 16mm
203iii) Size 32mm x 16mm
204Supply of wall fan 16"" Sweep (400mm) oscillating type light duty complete with built-in regulator , blade, jali complete.( Make Havellsmodel Platina/ Crompton make Model High flo L.G)
205Supply and erection of energy eficent LED 6000 K round luminiare , complete with diffuser , energy efficent electronicdriver and othermaterial required to complete job including fixing the same in false ceiling with required material and making necessary connection etc. i) LED 18 W square fitting surface mounting
206Supply and erection of Vertical double door sheet enclosure distributiuon board (IP43) suitbale for MCCB as incomer recessed in wall including bonding to earth with all labourand material reqquired to complete the job in all respect upto the entire satifaction of the Engineer in charge of the work.
207b) 8 way TPN (vertical , MCCB provision as Incomer and provision for 24 No. 6-32 amp MCB SP as outgoings)
208Surface & Erection of surface mountingLED Batten fitting 1 x18 watt, (4 feet long) made of high grade poly carbonate body provided for efficent heat dissipation & integrated electronic driver suitable for single phase A.C. 230 volts , 50 Hz supply complete in all respect.
209S/E of ISI marked propeller type ventilating fans (Exhaust fan) suitable for single phase230 Volt, 50 Hz AC,complete with mounting rings with four no. fixing holes without regulator as per following specification under general technical requirements C.G Modle Heavy Duty or Havells Turboforce
2101. sweep = 300 mm
211S/E of louver shutter for exhaust fan including all labour comlete in all respect.
212S/E of Exhaust fan PVC body 250 mm outer with louver shutter and petty material required to complete the job in all respect. C.G model Brisk Air or Havells Platina
213Supply and erection of energy efficent LED 6000 K Round Luminiare complete with diffuser, energy efficent electronic driver and other material required required to complete the job including fixing the same in false ceiling with required material& making necessaryconnection etc:
214i) LED 36 W recess mounting2"x2"
215SITC of 2 Tr high wall mount split A.C unit of 5 star inverter type rating (Hitachi/ Mitusubishi, O-General , Daikin make) to be operated on 220 Volts (+)(-) 10% single phase 50 Hz AC supply and consisting of Condensing indoor unit cordless remote upto 3.0 RMT of hard copper refrigent piping with insulation and cabling between indoor and outdoor unit ,MS stand complete in all respect
216SITC of 1.5 Tr high wall mount split inverter typeA.C unit of 5 star rating to be operated on 220 Volts (+)(-) 10% single phase 50 Hz AC supply and consisting of Condensing indoor unit cordless remote upto 3.0 RMT of hard copper refrigrent piping with insulation and cabling between indoor and outdoor unitand MS stand complete in all respect
217Supply and erection ofISI markerd FRLS PVC insulated single core copper conductor cable complete in all respect.
218a) 1.5 sqmm
219b)4.0 sqmm
220Providing and fixing of GI concealed sheet metal box with inner and outer face plate including fixing the box on surface of wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respect. (On Surface)
221a) 2 Module
222b) 3 Module
223c) 4 Module
224d) 6 Module
225e) 12 Module
226Supply of LT armoured cable of following 1100 Volt and complete with making necessary connection of cable on both ends including loading, unloading and carriage with all labour and petty material required to complete the job upto the entire satisfaction of Engineer-in-Chargre of the work. 1) LT armoured cable of size 35sqmm4 core
227S/E of LED Flood light 50 watt suitable for operation on 230 Volts A.C. Supply
228Total NS
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail