Bids Are Invited For Serviceability Checks / Overhaul Of Electronic Equipment - ( A ) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. ( B ) Check Connectors For Proper Mating And Grounding. ( C ) Clean All Pcbs /-Goa

Department of Defence Production has published Bids Are Invited For Serviceability Checks / Overhaul Of Electronic Equipment - ( A ) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. ( B ) Check Connectors For Proper Mating And Grounding. ( C ) Clean All Pcbs /. Submission Date for this Tender is 17-02-2022. Housekeeping Equipments Tenders in Goa. Bidders can get complete Tender details and download the document.




Tender Notice

30416960
Corrigendum : Bids Are Invited For Serviceability Checks / Overhaul Of Electronic Equipment - ( A ) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. ( B ) Check Connectors For Proper Mating And Grounding. ( C ) Clean All Pcbs /
Indian
Goa
17-02-2022

Tender Details

Bids Are Invited For Serviceability Checks / Overhaul Of Electronic Equipment - ( A ) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. ( B ) Check Connectors For Proper Mating And Grounding. ( C ) Clean All Pcbs / Modules And Check For Correct Functionality. Procure And Renew If Faulty. ( D ) Smps / Power Supply Unit To Be Checked For Rated Input / Outputs. Renew If Faulty. ( E ) Systems Having Software To Be Checked For Correct Functionality. ( F ) Check The Cable And Connectors For Cuts, Corrosion Or Undue Strain. ( G ) Clean The Air Filter With Vacuum Cleaner As Applicable. ( H ) Check The Set For Optimum / Designed Performance And Reliability. ( J ) Replace The Defective Lamps / Caps / Fuses / Hinges / Screws / Knobs / Keys / Switches. ( K ) All Existing Shock Mounts / Base Plates / Foundations To Be Checked For Integrity And Renew If Necessary. ( L ) Renew All Earthing / Bonding Straps. ( M ) Renew All Terminal Lugs ( N ) Renew Of Emi / Emc Gaskets Of All Openings Of Equipment. ( P ) Interfacing To All Systems To Be Proved As Applicable. ( Q ) Carry Out All Annual Routines And Performances Tests As Per Maintop At Shop Floor , Post Overhaul / Serviceability Checks - Post Overhaul / Repair / Routines Following To Be Carried Out:- ( A ) All Systems / Equipments / Machinary Should Be Proved To Rated / Designed Power / Capacity Without Limitations / Observations And Trials To Be Offered To The Naval Trial Agencies For Design Specifications Along With Installation Inspections As Per Approved Wlds, Op Checks, Hats And Sats. ( B ) Any Unserviceability During Undertaking Above Serial Needs To Be Repaired / Renewed By Firm Inclusive Of Spares. ( C ) Vibration Levels At All Points Should Be Less Than 5 Mm / Sec.The Equipment Performance Will Be Considered Satisfactory Only If The Performance Trials Are Cleared By Naval Inspection Agency. ( D ) Present System For Hats And Sats As Per The Standards Of Watt. , Ctd General-Ii ( Mt-74221 ) - Make: Bel, Benglore Model: General-Ii Oems Local Representative: M / S Elektronik Lab, Kochi ( A ) Serviceability Checks Ofcomplete Equipment To Be Carried Out As Per Sow 3. , 1 ( Ctd General-Ii ) - ( B ) Cooling Fans In The Monitor Unit Are To Be Checked For Proper Functioning. , 2 ( Ctd General-Ii ) - ( C ) Change The Battery Unit Of System. , 3 ( Ctd General-Ii ) - ( D ) Cleaning And Inspection Of Units. Carry Out Visual Internal Inspection / Cleaning Of Units. , 4 ( Ctd General-Ii ) - ( E ) Check Earth Bonding And Countinuety Inspection. , 5 ( Ctd General-Ii ) - ( F ) Measure The +5 Volt At The Raster Controller Pcb , 6 ( Ctd General-Ii ) - ( G ) Inspect The Air Filter In The Processor Unit.Clean Or Change As Necessary. , 7 ( Ctd General-Ii ) - ( H ) System To Be Offered For Trials As Per Sow 4. , Mandotoryspares 1 ( B9036b-456800101703 ) - Fuse Link Glass 5A Antisurge , 2 ( B9039b-456910300283 ) - Fuse Link 2.5A Antisurge , 3 ( B9039b-456910300283 ) - Lamp 14V, 80Ma T13 / 4 382Bp , 4 ( B9039b-456910300283 ) - Lamp 28V, 0.04A , 5 ( B9039b-456910300283 ) - Panel Soft Key , 6 ( B9039b-456910300283 ) - Lamp Pcb Assy. , 7 ( B9039b-456910300283 ) - Fan Assy Display , 8 ( B9039b-456910300283 ) - Fuse Link Glass 50Ma , 9 ( B9039b-456910300283 ) - Fuse Link Glass 3.15A , 10 ( B9039b-456910300283 ) - Fuse Link Ceramic 6A , 11 ( B9039b-456910300283 ) - Fuse Link Ceramic 7A , 12 ( B9039b-456910300283 ) - Relay, 4 Pole 24V , 13 ( B9039b-456910300283 ) - Relay, 2 Pole 24V , 14 ( B9039b-456910300283 ) - Air Filter , 15 ( B9039b-456910300283 ) - Power Supply Unit , 16 ( B9039b-456910300283 ) - Battery Fuse Unit , 17 ( B9039b-456910300283 ) - System Interface Pcb , 18 ( B9039b-456910300283 ) - Raster Controller Pcb , 19 ( B9039b-456910300283 ) - Main Processor Pcb , 20 ( B9039b-456910300283 ) - Colour Graphics Pcb , 21 ( B9039b-456910300283 ) - Track Controller Pcb , 22 ( B9039b-456910300283 ) - Arpa Pcb , 23 ( B9039b-456910300283 ) - Power Supply Interface Pcb , 24 ( B9039b-456910300283 ) - Battery Unit , Na - 3 Kva Online Ups , Nil - ( 12V, 42 Ahbattery ) , 25 ( Eb3050b-112003457734 ) - Terminal Pcb Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Jan-2022 11-01-2022
2 11-Jan-2022 14-01-2022
3 07-Feb-2022 11-02-2022
4 10-Feb-2022 17-02-2022

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl. No. Item TitleItem Description
1Serviceability checks/ overhaul of Electronic equipment(a) Clean dust, dirt and moisture from the internal and external surface of the units. (b) Check connectors for proper mating and grounding. (c) clean all PCBs/ modules and check for correct functionality. procure and renew if faulty. (d) SMPS/ power supply unit to be checked for rated input/ outputs. renew if faulty. (e) Systems having software to be checked for correct functionality. (f) Check the cable and connectors for cuts, corrosion or undue strain. (g) Clean the air filter with vacuum cleaner as applicable. (h) Check the set for optimum/ designed performance and reliability. (j) Replace the defective lamps/caps/ fuses/ hinges/ screws/ knobs/ keys/ switches. (k) All existing shock mounts / base plates / foundations to be checked for integrity and renew if necessary. (l)Renew all earthing/ bonding straps. (m) Renew all terminal lugs (n) Renew of EMI/ EMC gaskets of all openings of equipment. (p)interfacing to all systems to be proved as applicable. (q) Carry out all Annual routines and performances tests as per Maintop at shop floor
2post overhaul/ serviceability checksPost overhaul /repair/ routines following to be carried out:- (a) All systems/ equipments/ machinary should be proved to rated/designed power /capacity without limitations /observations and trials to be offered to the naval trial agencies for design specifications along with installation inspections as per approved WLDs, Op checks, HATs and SATs. (b) Any unserviceability during undertaking above serial needs to be repaired / renewed by firm inclusive of spares. (c)Vibration levels at all points should be less than 5 mm/sec.The equipment performance will be considered satisfactory only if the performance trials are cleared by naval inspection agency. (d) Present system for HATS and SATS as per the standards of WATT.
3CTD General-II (MT-74221)Make: BEL,Benglore Model: GENERAL-II OEM"s Local Representative: M/s Elektronik Lab, Kochi (a) Serviceability Checks ofcomplete equipment to be carried out as per SOW 3.
41 (CTD General-II)(b) Cooling fans in the Monitor unit are to be checked for proper functioning.
52 (CTD General-II)(c) Change the battery Unit of system.
63 (CTD General-II)(d) Cleaning and inspection of Units. Carry out Visual internal inspection/cleaning of Units.
74 (CTD General-II)(e) Check earth bonding and countinuety inspection.
85 (CTD General-II)(f) Measure the +5 volt at the raster controller PCB
96 (CTD General-II)(g) Inspect the air filter in the processor unit.Clean or change as necessary.
107 (CTD General-II)(h) System to be offered for trials as per SOW 4.
11MandotorySpares 1 (B9036B-456800101703)FUSE LINK GLASS 5A ANTISURGE
122 (B9039B-456910300283)FUSE LINK 2.5A ANTISURGE
133 (B9039B-456910300283)LAMP 14V,80mA T13/4 382BP
144 (B9039B-456910300283)LAMP 28V,0.04A
155 (B9039B-456910300283)PANEL SOFT KEY
166 (B9039B-456910300283)LAMP PCB ASSY.
177 (B9039B-456910300283)FAN ASSY DISPLAY
188 (B9039B-456910300283)FUSE LINK GLASS 50mA
199 (B9039B-456910300283)FUSE LINK GLASS 3.15A
2010 (B9039B-456910300283)FUSE LINK CERAMIC 6A
2111 (B9039B-456910300283)FUSE LINK CERAMIC 7A
2212 (B9039B-456910300283)RELAY,4 POLE 24V
2313 (B9039B-456910300283)RELAY,2 POLE 24V
2414 (B9039B-456910300283)AIR FILTER
2515 (B9039B-456910300283)POWER SUPPLY UNIT
2616 (B9039B-456910300283)BATTERY FUSE UNIT
2717 (B9039B-456910300283)SYSTEM INTERFACE PCB
2818 (B9039B-456910300283)RASTER CONTROLLER PCB
2919 (B9039B-456910300283)MAIN PROCESSOR PCB
3020 (B9039B-456910300283)COLOUR GRAPHICS PCB
3121 (B9039B-456910300283)TRACK CONTROLLER PCB
3222 (B9039B-456910300283)ARPA PCB
3323 (B9039B-456910300283)POWER SUPPLY INTERFACE PCB
3424 (B9039B-456910300283)BATTERY UNIT
35NA3 KVA Online UPS
36NIL(12V, 42 AHBATTERY)
3725 (EB3050B-112003457734)TERMINAL PCB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail