Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #30416960

Bids Are Invited For Serviceability Checks / Overhaul Of Electronic Equipment - ( A ) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. ( B ) Check Connectors For Proper Mating And Grounding. ( C ) Clean All Pcbs /

Issued by Statutory Bodies & Commissions/Committees · , Goa
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Feb 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are Invited For Serviceability Checks / Overhaul Of Electronic Equipment - ( A ) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. ( B ) Check Connectors For Proper Mating And Grounding. ( C ) Clean All Pcbs / Modules And Check For Correct Functionality. Procure And Renew If Faulty. ( D ) Smps / Power Supply Unit To Be Checked For Rated Input / Outputs. Renew If Faulty. ( E ) Systems Having Software To Be Checked For Correct Functionality. ( F ) Check The Cable And Connectors For Cuts, Corrosion Or Undue Strain. ( G ) Clean The Air Filter With Vacuum Cleaner As Applicable. ( H ) Check The Set For Optimum / Designed Performance And Reliability. ( J ) Replace The Defective Lamps / Caps / Fuses / Hinges / Screws / Knobs / Keys / Switches. ( K ) All Existing Shock Mounts / Base Plates / Foundations To Be Checked For Integrity And Renew If Necessary. ( L ) Renew All Earthing / Bonding Straps. ( M ) Renew All Terminal Lugs ( N ) Renew Of Emi / Emc Gaskets Of All Openings Of Equipment. ( P ) Interfacing To All Systems To Be Proved As Applicable. ( Q ) Carry Out All Annual Routines And Performances Tests As Per Maintop At Shop Floor , Post Overhaul / Serviceability Checks - Post Overhaul / Repair / Routines Following To Be Carried Out:- ( A ) All Systems / Equipments / Machinary Should Be Proved To Rated / Designed Power / Capacity Without Limitations / Observations And Trials To Be Offered To The Naval Trial Agencies For Design Specifications Along With Installation Inspections As Per Approved Wlds, Op Checks, Hats And Sats. ( B ) Any Unserviceability During Undertaking Above Serial Needs To Be Repaired / Renewed By Firm Inclusive Of Spares. ( C ) Vibration Levels At All Points Should Be Less Than 5 Mm / Sec.The Equipment Performance Will Be Considered Satisfactory Only If The Performance Trials Are Cleared By Naval Inspection Agency. ( D ) Present System For Hats And Sats As Per The Standards Of Watt. , Ctd General-Ii ( Mt-74221 ) - Make: Bel, Benglore Model: General-Ii Oems Local Representative: M / S Elektronik Lab, Kochi ( A ) Serviceability Checks Ofcomplete Equipment To Be Carried Out As Per Sow 3. , 1 ( Ctd General-Ii ) - ( B ) Cooling Fans In The Monitor Unit Are To Be Checked For Proper Functioning. , 2 ( Ctd General-Ii ) - ( C ) Change The Battery Unit Of System. , 3 ( Ctd General-Ii ) - ( D ) Cleaning And Inspection Of Units. Carry Out Visual Internal Inspection / Cleaning Of Units. , 4 ( Ctd General-Ii ) - ( E ) Check Earth Bonding And Countinuety Inspection. , 5 ( Ctd General-Ii ) - ( F ) Measure The +5 Volt At The Raster Controller Pcb , 6 ( Ctd General-Ii ) - ( G ) Inspect The Air Filter In The Processor Unit.Clean Or Change As Necessary. , 7 ( Ctd General-Ii ) - ( H ) System To Be Offered For Trials As Per Sow 4. , Mandotoryspares 1 ( B9036b-456800101703 ) - Fuse Link Glass 5A Antisurge , 2 ( B9039b-456910300283 ) - Fuse Link 2.5A Antisurge , 3 ( B9039b-456910300283 ) - Lamp 14V, 80Ma T13 / 4 382Bp , 4 ( B9039b-456910300283 ) - Lamp 28V, 0.04A , 5 ( B9039b-456910300283 ) - Panel Soft Key , 6 ( B9039b-456910300283 ) - Lamp Pcb Assy. , 7 ( B9039b-456910300283 ) - Fan Assy Display , 8 ( B9039b-456910300283 ) - Fuse Link Glass 50Ma , 9 ( B9039b-456910300283 ) - Fuse Link Glass 3.15A , 10 ( B9039b-456910300283 ) - Fuse Link Ceramic 6A , 11 ( B9039b-456910300283 ) - Fuse Link Ceramic 7A , 12 ( B9039b-456910300283 ) - Relay, 4 Pole 24V , 13 ( B9039b-456910300283 ) - Relay, 2 Pole 24V , 14 ( B9039b-456910300283 ) - Air Filter , 15 ( B9039b-456910300283 ) - Power Supply Unit , 16 ( B9039b-456910300283 ) - Battery Fuse Unit , 17 ( B9039b-456910300283 ) - System Interface Pcb , 18 ( B9039b-456910300283 ) - Raster Controller Pcb , 19 ( B9039b-456910300283 ) - Main Processor Pcb , 20 ( B9039b-456910300283 ) - Colour Graphics Pcb , 21 ( B9039b-456910300283 ) - Track Controller Pcb , 22 ( B9039b-456910300283 ) - Arpa Pcb , 23 ( B9039b-456910300283 ) - Power Supply Interface Pcb , 24 ( B9039b-456910300283 ) - Battery Unit , Na - 3 Kva Online Ups , Nil - ( 12V, 42 Ahbattery ) , 25 ( Eb3050b-112003457734 ) - Terminal Pcb Total Quantity : 1

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Jan-2022 11-Jan-2022
2 11-Jan-2022 14-Jan-2022
3 10-Feb-2022 17-Feb-2022
4 07-Feb-2022 11-Feb-2022

BOQ

Sl. No. Item TitleItem Description
1Serviceability checks/ overhaul of Electronic equipment(a) Clean dust, dirt and moisture from the internal and external surface of the units. (b) Check connectors for proper mating and grounding. (c) clean all PCBs/ modules and check for correct functionality. procure and renew if faulty.(d) SMPS/ power supply unit to be checked for rated input/ outputs. renew if faulty.(e) Systems having software to be checked for correct functionality. (f) Check the cable and connectors for cuts, corrosion or undue strain. (g) Clean the air filter with vacuum cleaner as applicable.(h) Check the set for optimum/ designed performance and reliability. (j) Replace the defective lamps/caps/ fuses/ hinges/ screws/ knobs/ keys/ switches. (k) All existing shock mounts / base plates / foundations to be checked for integrity and renew if necessary.(l)Renew all earthing/ bonding straps. (m) Renew all terminal lugs(n) Renew of EMI/ EMC gaskets of all openings of equipment.(p)interfacing to all systems to be proved as applicable.(q) Carry out all Annual routines and performances tests as per Maintop at shop floor
2post overhaul/ serviceability checksPost overhaul /repair/ routines following to be carried out:-(a) All systems/ equipments/ machinary should be proved to rated/designed power /capacity without limitations /observations and trials to be offered to the naval trial agencies for design specifications along with installation inspections as per approved WLDs, Op checks, HATs and SATs. (b) Any unserviceability during undertaking above serial needs to be repaired / renewed by firm inclusive of spares.(c)Vibration levels at all points should be less than 5 mm/sec.The equipment performance will be considered satisfactory only if the performance trials are cleared by naval inspection agency. (d) Present system for HATS and SATS as per the standards of WATT.
3CTD General-II (MT-74221)Make: BEL,Benglore Model: GENERAL-II OEM\"s Local Representative: M/s Elektronik Lab, Kochi(a) Serviceability Checks ofcomplete equipment to be carried out as per SOW 3.
41 (CTD General-II)(b) Cooling fans in the Monitor unit are to be checked for proper functioning.
52 (CTD General-II)(c) Change the battery Unit of system.
63 (CTD General-II)(d) Cleaning and inspection of Units. Carry out Visual internal inspection/cleaning of Units.
74 (CTD General-II)(e) Check earth bonding and countinuety inspection.
85 (CTD General-II)(f) Measure the +5 volt at the raster controller PCB
96 (CTD General-II)(g) Inspect the air filter in the processor unit.Clean or change as necessary.
107 (CTD General-II)(h) System to be offered for trials as per SOW 4.
11MandotorySpares 1 (B9036B-456800101703)FUSE LINK GLASS 5A ANTISURGE
122 (B9039B-456910300283)FUSE LINK 2.5A ANTISURGE
133 (B9039B-456910300283)LAMP 14V,80mA T13/4 382BP
144 (B9039B-456910300283)LAMP 28V,0.04A
155 (B9039B-456910300283)PANEL SOFT KEY
166 (B9039B-456910300283)LAMP PCB ASSY.
177 (B9039B-456910300283)FAN ASSY DISPLAY
188 (B9039B-456910300283)FUSE LINK GLASS 50mA
199 (B9039B-456910300283)FUSE LINK GLASS 3.15A
2010 (B9039B-456910300283)FUSE LINK CERAMIC 6A
2111 (B9039B-456910300283)FUSE LINK CERAMIC 7A
2212 (B9039B-456910300283)RELAY,4 POLE 24V
2313 (B9039B-456910300283)RELAY,2 POLE 24V
2414 (B9039B-456910300283)AIR FILTER
2515 (B9039B-456910300283)POWER SUPPLY UNIT
2616 (B9039B-456910300283)BATTERY FUSE UNIT
2717 (B9039B-456910300283)SYSTEM INTERFACE PCB
2818 (B9039B-456910300283)RASTER CONTROLLER PCB
2919 (B9039B-456910300283)MAIN PROCESSOR PCB
3020 (B9039B-456910300283)COLOUR GRAPHICS PCB
3121 (B9039B-456910300283)TRACK CONTROLLER PCB
3222 (B9039B-456910300283)ARPA PCB
3323 (B9039B-456910300283)POWER SUPPLY INTERFACE PCB
3424 (B9039B-456910300283)BATTERY UNIT
35NA3 KVA Online UPS
36NIL(12V, 42 AHBATTERY)
3725 (EB3050B-112003457734)TERMINAL PCB

AI Tender Summary

OUR REF NO 30416960
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 17-02-2022
Authority
Authority Name Department of Defence Production
Work Description Bids Are Invited For Serviceability Checks / Overhaul Of Electronic Equipment - ( A ) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. ( B ) Check Connectors For Proper Mating And Grounding. ( C ) Clean All Pcbs / Modules And Check For Correct Functionality. Procure And Renew If Faulty. ( D ) Smps / Power Supply Unit To Be Checked For Rated Input / Outputs. Renew If Faulty. ( E ) Systems Having Software To Be Checked For Correct Functionality. ( F ) Check The Cable And Connectors For Cuts, Corrosion Or Undue Strain. ( G ) Clean The Air Filter With Vacuum Cleaner As Applicable. ( H ) Check The Set For Optimum / Designed Performance And Reliability. ( J ) Replace The Defective Lamps / Caps / Fuses / Hinges / Screws / Knobs / Keys / Switches. ( K ) All Existing Shock Mounts / Base Plates / Foundations To Be Checked For Integrity And Renew If Necessary. ( L ) Renew All Earthing / Bonding Straps. ( M ) Renew All Terminal Lugs ( N ) Renew Of Emi / Emc Gaskets Of All Openings Of Equipment. ( P ) Interfacing To All Systems To Be Proved As Applicable. ( Q ) Carry Out All Annual Routines And Performances Tests As Per Maintop At Shop Floor , Post Overhaul / Serviceability Checks - Post Overhaul / Repair / Routines Following To Be Carried Out:- ( A ) All Systems / Equipments / Machinary Should Be Proved To Rated / Designed Power / Capacity Without Limitations / Observations And Trials To Be Offered To The Naval Trial Agencies For Design Specifications Along With Installation Inspections As Per Approved Wlds, Op Checks, Hats And Sats. ( B ) Any Unserviceability During Undertaking Above Serial Needs To Be Repaired / Renewed By Firm Inclusive Of Spares. ( C ) Vibration Levels At All Points Should Be Less Than 5 Mm / Sec.The Equipment Performance Will Be Considered Satisfactory Only If The Performance Trials Are Cleared By Naval Inspection Agency. ( D ) Present System For Hats And Sats As Per The Standards Of Watt. , Ctd General-Ii ( Mt-74221 ) - Make: Bel, Benglore Model: General-Ii Oems Local Representative: M / S Elektronik Lab, Kochi ( A ) Serviceability Checks Ofcomplete Equipment To Be Carried Out As Per Sow 3. , 1 ( Ctd General-Ii ) - ( B ) Cooling Fans In The Monitor Unit Are To Be Checked For Proper Functioning. , 2 ( Ctd General-Ii ) - ( C ) Change The Battery Unit Of System. , 3 ( Ctd General-Ii ) - ( D ) Cleaning And Inspection Of Units. Carry Out Visual Internal Inspection / Cleaning Of Units. , 4 ( Ctd General-Ii ) - ( E ) Check Earth Bonding And Countinuety Inspection. , 5 ( Ctd General-Ii ) - ( F ) Measure The +5 Volt At The Raster Controller Pcb , 6 ( Ctd General-Ii ) - ( G ) Inspect The Air Filter In The Processor Unit.Clean Or Change As Necessary. , 7 ( Ctd General-Ii ) - ( H ) System To Be Offered For Trials As Per Sow 4. , Mandotoryspares 1 ( B9036b-456800101703 ) - Fuse Link Glass 5A Antisurge , 2 ( B9039b-456910300283 ) - Fuse Link 2.5A Antisurge , 3 ( B9039b-456910300283 ) - Lamp 14V, 80Ma T13 / 4 382Bp , 4 ( B9039b-456910300283 ) - Lamp 28V, 0.04A , 5 ( B9039b-456910300283 ) - Panel Soft Key , 6 ( B9039b-456910300283 ) - Lamp Pcb Assy. , 7 ( B9039b-456910300283 ) - Fan Assy Display , 8 ( B9039b-456910300283 ) - Fuse Link Glass 50Ma , 9 ( B9039b-456910300283 ) - Fuse Link Glass 3.15A , 10 ( B9039b-456910300283 ) - Fuse Link Ceramic 6A , 11 ( B9039b-456910300283 ) - Fuse Link Ceramic 7A , 12 ( B9039b-456910300283 ) - Relay, 4 Pole 24V , 13 ( B9039b-456910300283 ) - Relay, 2 Pole 24V , 14 ( B9039b-456910300283 ) - Air Filter , 15 ( B9039b-456910300283 ) - Power Supply Unit , 16 ( B9039b-456910300283 ) - Battery Fuse Unit , 17 ( B9039b-456910300283 ) - System Interface Pcb , 18 ( B9039b-456910300283 ) - Raster Controller Pcb , 19 ( B9039b-456910300283 ) - Main Processor Pcb , 20 ( B9039b-456910300283 ) - Colour Graphics Pcb , 21 ( B9039b-456910300283 ) - Track Controller Pcb , 22 ( B9039b-456910300283 ) - Arpa Pcb , 23 ( B9039b-456910300283 ) - Power Supply Interface Pcb , 24 ( B9039b-456910300283 ) - Battery Unit , Na - 3 Kva Online Ups , Nil - ( 12V, 42 Ahbattery ) , 25 ( Eb3050b-112003457734 ) - Terminal Pcb Total Quantity : 1
Basic Detail
Tender No GEM/2021/B/1787506
Bidding Type Tender
Location
City
State Goa
Key Dates
Publish Date 10 Feb 2022
Submission Date 17 Feb 2022
Open Date 17 Feb 2022
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
2971169_Boq_4.xlsx
83dbb07f-05a1-4962-89e5-228772ab5987.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 10, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 11, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 14, 2022
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 17, 2022
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 11, 2022
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 17, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 17, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xlsx

2971169_Boq_4.xlsx

pdf

83dbb07f-05a1-4962-89e5-228772ab5987.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders