Providing Ei In Science Building G Plus 2 At Kailashahar College Unakoti District
Tender Value
36.03 Lakhs
Estimated cost
Bid Submission
10 Jan 2022
0 days left
EMD
36030
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
KAILASHAHAR → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Providing Ei In Science Building G Plus 2 At Kailashahar College Unakoti District
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | a) Short Point :- |
| 3 | b) Medium Point :- |
| 4 | c) Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | a.2x1.5 sq.mm: |
| 9 | b.2 X 2.5 sq mm |
| 10 | c.2x4 sq mm |
| 11 | d.4x6 sq mm |
| 12 | e.4 X 10 sq mm |
| 13 | f.4 X 16 sq mm |
| 14 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 15 | a. 1 X 1.5 sq mm |
| 16 | b. 1 X 4 sq mm |
| 17 | c. 1 X 10 sq mm |
| 18 | Providingearthing systemwith maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminalsize 32mmx 6mm including accessories with masonry enclosure of CIcover plate size 12\"x 12\" having locking arrangement including CC works etc as required:- |
| 19 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copperwire on surface or inexisting G.I / PVC / Polythene pipe for loop earthing as required. |
| 20 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 21 | a. 200 amps TPN 415 voltsfront handle cubical main switch (HRC):- |
| 22 | b. 100 amps TPN 415 voltsfront handle cubical main switch (HRC):- |
| 23 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 24 | a. 200 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx120mm):- |
| 25 | b. 100 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx120mm):- |
| 26 | Supplying and installation of change over switch of following ratings in existing enclosure/panel including necessary connection etc. as required :- |
| 27 | a. 200 amps FP on load change over switch (Front handle without enclosure):- |
| 28 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 29 | a. 16 to 100 amps FP MCCB, Breakingcapacity 16/18KA (Thermal Magnetic):- |
| 30 | Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required:- |
| 31 | a. Enclosure suitable for MCCB upto 100 amps:- |
| 32 | Supplying & installation of Astronomical timer Switch including necessary connection etc as required:- |
| 33 | Supplying & installation of following power contactors including necessary connection etc as required:- |
| 34 | a. 3 pole 18 amps (AC3)power contactors with 1NO+1NC Aux. Contact. |
| 35 | Supplying, installation, testing and commissioning of following ratings online UPS with inbuilt isolation transformer, 50/60Hz (Auto sensing) frequency, P.F range 0.95-0.99, voltage regulation +/-1%, Pure sine wave form, total harmonic distortion < 5% with full load, Noise level 50db at 1m, LED indication for Normal mode/Load on battery/Load on bypass/System fault, Audible alarm forMains failure, low battery, Overload, fault and Bypass mode complete with M. S Rack for mounting battery bank, Battery inter link cables and all other necessary accessories including connections etc. as required:- |
| 36 | a. 1 kVA, 1 Ph input/1 Ph output Online UPS with 3024 VAH battery bank for minimum 2 hours Backup:- |
| 37 | Supply and fixing of the following sizes GIprongwith necessary nuts & bolts etc as required grouted on roof for Lightning protection. |
| 38 | a. G.I Prong 450 mm long |
| 39 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 40 | Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required:- |
| 41 | a. Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 15 KA (3P+N) :- |
| 42 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 43 | a. 12 module plastic switch board:- |
| 44 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 45 | a. 12 module :- |
| 46 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 47 | a. Musical call bell |
| 48 | b. 32 amps DP kit kat switch:- |
| 49 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 50 | a. Bell push SP (1M) :- |
| 51 | b. 5 step fan regulator (2M):- |
| 52 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required. |
| 53 | a. 4way horizontal TPN MCB DB (Double door):- |
| 54 | b. 6way horizontal TPN MCB DB (Double door):- |
| 55 | c. 2 way SPN MCB DB (single door):- |
| 56 | d. 4 way SPN MCB DB (single door):- |
| 57 | Supplying & installation of RCCB (sensitivity 30mA to 300mA) of following ratings in the existing MCB DB including connection etc as required:- |
| 58 | a. 16 to 40 amps DP RCCB:- |
| 59 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:- |
| 60 | a. 6 to 32 amps SP MCB:- |
| 61 | b. 6 to 32 amps DP MCB:- |
| 62 | c. 6 to 32 amps TPN MCB:- |
| 63 | Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
| 64 | a. Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL,electronic ballast and high quality reflector cover : - |
| 65 | b. Box type double FTL fittings of CRCA steel sheet housing complete with 2 nos. 36/40 W FTL,electronic ballast and high quality reflector cover: - |
| 66 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : - |
| 67 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 68 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 69 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 70 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:- |
| 71 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 72 | a. Recessed round/Square shaped 18 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 73 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 74 | a. 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 75 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 76 | a. 3 core4 Sq mm |
| 77 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 78 | a. 40 mm dia |
| 79 | Supplying and fixing of 20 mm MS pipe as down rod for installation of luminaries with necessary accessories etc as required. |
| 80 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
AI Tender Summary
Tender Timeline
Dec 22, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedJan 10, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 11, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender