Aruppukkottai Municipality Supply , Delivery And Fixing Electromagnetic Flow Meter At Kattangudi Booster Station And Madurai Road Tank And Supply Of Double Air Valve And Construction Of Valve Pit In 3Pbt To Kattangudi Booster Station In Aruppukkotta, ARUPPUKOTTAI-Tamil Nadu

municipality has published Aruppukkottai Municipality Supply , Delivery And Fixing Electromagnetic Flow Meter At Kattangudi Booster Station And Madurai Road Tank And Supply Of Double Air Valve And Construction Of Valve Pit In 3Pbt To Kattangudi Booster Station In Aruppukkotta. Submission Date for this Tender is 29-12-2021. Valve Tenders in ARUPPUKOTTAI Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

30400317
Aruppukkottai Municipality Supply , Delivery And Fixing Electromagnetic Flow Meter At Kattangudi Booster Station And Madurai Road Tank And Supply Of Double Air Valve And Construction Of Valve Pit In 3Pbt To Kattangudi Booster Station In Aruppukkotta
Open Tender
Indian
Tamil Nadu
ARUPPUKOTTAI
29-12-2021

Tender Details

Aruppukkottai Municipality Supply , Delivery And Fixing Electromagnetic Flow Meter At Kattangudi Booster Station And Madurai Road Tank And Supply Of Double Air Valve And Construction Of Valve Pit In 3Pbt To Kattangudi Booster Station In Aruppukkotta

Key Value

Document Fees
Refer document
EMD
INR 22000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of work :Supply , Delivery and Fixing Electromagnetic Flow Meter@ Kattangudi Booster Station and Madurai Road Tank and Supply of Double Air valve and Construction of Valve pit in 3PBT to Kattangudi Booster station in Aruppukkottai Municipality. Estimate Amount Rs.22.00 lakhs
Sl. No. Item Description
1Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304) for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.
2350 MM
3Supply and Fixing of1KVA Online Upssingle phase with one hour back up etc., complete)
4Supply and Delivery ofC.I. DOUBLE AIR VALVE AS PER ISI 14845/2000 etc., complete
5100 MM
6Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete
7Conveyance and Removal of Excavated Excess Earth away from the site to 2K.M including loading and transportation charges etc, complete as per standard specification.
8Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per ss.
9Providing centering shuttering including necessary supports for height using country wood joist of size 10cmx6.50cm spaced at 90cm center to center and supporting by casurina props of 10 cm to 13 xm dia. As directed for column, beam, slab cantilever beam, cantilever slab, waist slab and slope surface etc., complete as per ss.
10Suppling and fabrication placing in position of M.S.(or)RTS rod for required size and length as directed by the departmental officers approved design including bending cutting tying and cost of binding wire cost and conveyance of all materials to site etc. complete as per standard specification
11Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials)
12Labour Charge For Fixing the Air valve in Pipe line With necessary MS pipe Flage, Bolt & Nut , with weldingetc.,