| 1 | BLOOD DISORDER DISABILITY UNIT |
| 2 | Thalassemia Rapid test |
| 3 | Blood Gas Analyzer– (• Blood Gas Analyzer– • Essential measured parameters should be: pH, pCO2, pO2, Na+, K+, Ca++ or Cl- and Hct.• Calculated parameters which includes HCO3 actual HCO3 Std, BE (ecf), BE (B), ct Co2, Ca ++(7.4), Anion Gap, O2 Sat, O2 Ct, Po2 (A-a), Po2 (a/A), Ct Hb (est.), po2/F1O2.• Blood Gas Analyzer should be based on Gas Calibration principle• Should come with Maintenance free Ready sensors.• No membrane to be used.• Analyzer should have an intuitive color touch screen interface.• Analyzer should also have an attached Barcode scanner.• Should analyze both Syringe and Capillary samples • Should have a Micro sampling capability.• Minimum Sample Volume should be 50 µl.• Should have fast analysis time: 60 Seconds.• Should have Data print out on in built thermal printer.• Built in QC analysis software. Should also have a storage capacity of up to 250 patient rest records.• Should have Bi-directional connectivity and USB connectivity for data transfer and a RS 232 port.• Should be able to analyze dialysis fluids.• Should comply with the EMC directives (CE Mark), developed and manufactured by a BS EN ISO 9001 and EN46001 approved facility. • Should be provided with HIS connectivity software to enable remote viewing of analyzers, connecting analyzers and troubleshooting of analyzers.) |
| 4 | Methylene Blue Chemical – |
| 5 | Urine Analyzer– (• Specifications of Urine Analyzer:-• The system should be compact and easy to use.• Should be based on Reflectance spectrophotometer principle. • Should be designed to read 2, 4, 8 and up to 10 parameters of urine test strips mentioned as follows: • Albumin, Bilirubin, Creatinine, Glucose, Ketone, Leukocytes, Nitrite, pH, Protein, Speci?c gravity, and Urobilinogen and offer Albumin-to-creatinine ratio as calculated parameter.• Analyzer should have a through put of 60 samples / hour • Analyzer should automatically detect Strip types.• Analyzer should perform auto calibration before performing each test.• Analyzer should check strip for humidity exposure before performing the test. • Analyzer should also provide sample interference notes to interpret test results• Should display the results in LCD touch screen display of 4 - 5 inches with good resolution to display all the results. • The system should have in built thermal printer and also provision to connect to external printer. • Should have option to connect with handheld barcode reader • Should have option to run positive and negative quality control• Should work on 100V - 240V AC and 50-60 Hz power supply.• Shouldbe European CE marked and US FDA certified) |
| 6 | VISUAL UNIT |
| 7 | Hand held slit lamp |
| 8 | Direct Ophthalmoscope 2.8 v |
| 9 | Trial set power cotted/Stereo Acuity Test material |
| 10 | Trial frame for both adult and paediatric |
| 11 | Distance vision testing drum remote control motorised movement |
| 12 | VS-V Universal Vision Screener (for school going children also) |
| 13 | Tele Binocular Equipment |
| 14 | LED Vision Chart |
| 15 | Snellen Chart/Eye Testing Drum |
| 16 | Automatic Matrix Auto Refractometer R-20 for eye Examination |
| 17 | Near Vision Drum |
| 18 | Acuity Digital Vision Tester |
| 19 | Keratometer&Keratoscope tools |
| 20 | Brallier (Braille Type Writer) |
| 21 | Orbit Reader (Braille Embossed Reader) |
| 22 | Pen Scanner |
| 23 | Magnifiers for low vision (NIEPVD) |
| 24 | MAGIC software for low vision |
| 25 | Electronic Mobility Cane/White Cane |