| Sl. No. | Item Description |
| 1 | SH : I: EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing andramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.Ordinary Rock |
| 3 | Extra for every additional lift of 1.50 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 4 | Fillingavailableexcavatedearth(excludingrock)intrenches,plinth,sidesof foundationsetc.inlayersnotexceeding20cmindepth,consolidatingeach deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 5 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth inlayersnotexceeding20cmintrenches,plinth,sidesoffoundationetc. complete. |
| 6 | Supplyingandfillinginplinthwith sandunderfloors,includingwatering, ramming, consolidating and dressing complete. |
| 7 | SH : II: PCC WORK |
| 8 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 9 | 1:4:8 (1 cement : 4 coarse sand (Zone III) : 8 graded stone aggregate 40 mm nominal size). |
| 10 | SH : III : RCC WORK |
| 11 | Centering and shuttering including strutting, propping etc. and removalof form for : |
| 12 | a) Foundations, footings, bases of columns, etc. for mass concrete |
| 13 | Suspended floors, roofs, landings, balconies and accessplatform |
| 14 | b) Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 15 | c) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | d) Stairs, (excluding landings) except spiral-staircases |
| 17 | f) Extra for additional height in centering, shuttering where ever requiredwith adequate bracing, propping etc., including cost of de-shutteringand decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). |
| 18 | e) Suspended floors, roofs, landing, beams and balconies(Plan area to be measured) |
| 19 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishingandreinforcement,includingadmixturesin recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. |
| 20 | a) All works upto plinth level : Concrete of M-25 grade Mix with minimum cement content of 330kg/cum |
| 21 | b) All works above plinth level upto floor V level : Concrete of M-25 grade Mix with minimum cement content of 330kg/cum |
| 22 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. |
| 23 | Thermo Mechanically treated bars |
| 24 | Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 Kg per Sq.m. on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil |
| 25 | SH : IV: BRICK WORK |
| 26 | BrickworkwithcommonburntclayF.P.S.(nonmodular)bricksofclass designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 27 | Half brick masonry in cement mortar 1:4 (1 cement :4 coarse sand) in foundation and plinth. |
| 28 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 29 | Extra for providing and placing in position 2 Nos 6mm dia M.S. bars at every third course of half brick masonary. |
| 30 | SH:V :FLOORING WORK |
| 31 | Dry Stone Kharanja using stone as directed by Engineer In Charge using approved quality Stones |
| 32 | Providing and laying in foundations and plinth cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete |
| 34 | c) Size of Tile 600x600 mm |
| 35 | Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of eps,over 12mm thick bed of cemen tmortar1:3 (1cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete |
| 36 | c) Size of Tile 600x600 mm |
| 37 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 38 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 39 | Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse and) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 41 | SH : VI : FINISHING WORK |
| 42 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 43 | 15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall. |
| 44 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 45 | Granite of any colour and shade, Area of slab over 0.50 sqm |
| 46 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 47 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 48 | Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade: |
| 49 | New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 50 | Providing and Fixing of Exterior Texture Paint, complete in all respect and in supervision of Engineer-in-charge |
| 51 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : 13.60.1 Two or more coats on new work |
| 52 | Painting two coats with oil wood preservatives of approved brand and manufacture on new work. |
| 53 | French spirit polishing (two or more coats) including a coat of wood filler on new work |
| 54 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |
| 55 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate primimng coat, preparation of surface, etc, complete. On steel surface |
| 56 | SH : VII : WOOD/ ALUMINIUM WORK |
| 57 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood |
| 58 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 59 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. |
| 60 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 61 | a) For fixed portion |
| 62 | Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 63 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 64 | Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 65 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) |
| 66 | With float glass panes of 5 mm thickness. |
| 67 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 68 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.2Fixed to openings /wooden frames with rawl plugs screws etc. |
| 69 | Providing and fixing aluminum butt hinges anodised, transparent or dyed to required color or shade with necessary screws etc complete. |
| 70 | a) 100 x 63 x 4 mm |
| 71 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete. |
| 72 | a)250 x 10 mm |
| 73 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. |
| 74 | a)125 mm |
| 75 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a)300 x 16 mm |
| 76 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 77 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws andPVC sleeves etc., wherever necessary complete : |
| 78 | 9.46.325 mm dia |
| 79 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 80 | SH : VIII : SANITARY & PLUMBING WORK |
| 81 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 82 | a) White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 83 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 84 | Kitchen sink without drain board |
| 85 | a) 610x510 mm bowl depth 200 mm |
| 86 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 87 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 88 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 89 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 90 | Semi rigid pipe |
| 91 | a) 40 mm dia |
| 92 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 93 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 94 | Providing and fixing toilet paper holder : |
| 95 | a) C.P. brass |
| 96 | Providing and fixing soil, waste and vent pipes : |
| 97 | 100 mm dia |
| 98 | Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 99 | 75 mm diameter : |
| 100 | Centrifugally cast (spun) iron socketed pipe as per IS: 3989 |
| 101 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : |
| 102 | 75 mm diapipe |
| 103 | 100 mm diapipe |
| 104 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : |
| 105 | For 100 mm dia pipe |
| 106 | For 75 mm dia pipe |
| 107 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete |
| 108 | 100 mm dia |
| 109 | Sand cast iron S&S as per IS - 3989 |
| 110 | Providing and fixing heel rest sanitary bend |
| 111 | 100 mm dia |
| 112 | Sand cast iron S&S as per IS - 3989 |
| 113 | 75 mm dia |
| 114 | Sand cast iron S&S as per IS - 3989 |
| 115 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : |
| 116 | 100 mm |
| 117 | 75 mm |
| 118 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : |
| 119 | 100mm |
| 120 | 75mm |
| 121 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 122 | 100 mm inlet and 100 mm outlet |
| 123 | Sand cast iron S&S as per IS - 3989 |
| 124 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 125 | 100 mm dia |
| 126 | 75 mm dia |
| 127 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete |
| 128 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 129 | C.P.V.C. PIPES |
| 130 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 131 | Internal work - Exposed on wall |
| 132 | a) 20 mm nominal outer dia Pipes |
| 133 | b) 25 mm nominal outer dia Pipes |
| 134 | c) 32 mm nominal outer dia Pipes |
| 135 | d) 40 mm nominal outer dia Pipes |
| 136 | e) 50 mm nominal outer dia Pipes (For Bottle Trap & O.H. Filling) |
| 137 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge |
| 138 | Concealed work, including cutting chases and making good the walls etc. |
| 139 | a) 20 mm nominal outer dia Pipes |
| 140 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 141 | External work |
| 142 | 20 mm nominal outer dia Pipes |
| 143 | BRASS FITTINGS |
| 144 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 145 | 20 mm dia nominal bore |
| 146 | 25 mm dia nominal bore |
| 147 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : |
| 148 | 25 mm dia nominal bore |
| 149 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 150 | 30 cm length |
| 151 | 15 mm nominal bore |
| 152 | 45 cm length |
| 153 | 15 mm nominal bore |
| 154 | C.P. BRASS FITTINGS |
| 155 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 156 | 15 mm nominal bore |
| 157 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 158 | 15 mm nominal bore |
| 159 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 160 | 15 mm nominal bore |
| 161 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 162 | 15mm nominal bore |
| 163 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 164 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 165 | With common burnt clay F.P.S. (non modular) bricks |
| 166 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 167 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
| 168 | Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) including disposal of malba. |
| 169 | DRAINAGE |
| 170 | STONE WARE PIPES AND FITTINGS |
| 171 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
| 172 | 100 mm diameter pipe |
| 173 | 150 mm diameter pipe |
| 174 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : |
| 175 | 100 mm diameter S.W. pipe |
| 176 | 150 mm diameter S.W. pipe |
| 177 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 178 | 180x150 mm size P type |
| 179 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 180 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 181 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 182 | a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 183 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : |
| 184 | b) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 185 | Extra for depth for manholes : |
| 186 | Size 90x80 cm |
| 187 | a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 188 | Size 120x90 cm |
| 189 | b) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 190 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : |
| 191 | a) With 20x20 mm square bar |
| 192 | Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg |
| 193 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 194 | a) For pipes 100 to 250 mm diameter |
| 195 | SH : IX : STRUCTURAL GLAZING |
| 196 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment |
| 197 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: |
| 198 | (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: |
| 199 | (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. |
| 200 | (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. |
| 201 | (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. |
| 202 | (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporatingprinciples of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. |
| 203 | Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. |
| 204 | Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. |
| 205 | The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025. |
| 206 | 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr |
| 207 | 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. |
| 208 | 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml |
| 209 | 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm |
| 210 | 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site. |
| 211 | 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml |
| 212 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. |
| 213 | (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) |
| 214 | For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. |
| 215 | (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 216 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge. |
| 217 | Providing and fixing of Dorma ES-200 frameless Automatic bi-parting sliding door operator for clear opening size of 2000 mm x2400mm, modular design, including internal cover, eagle sensors on bothsides,Electromechanical lock,light barriers and programme switch complete, With Operator Dimensions (LxH x T): 4150x100 x180 mm. The track profile should be separate from the main profile for enabling reduction in vibration. Microprocessorcontrol, self-learning, reversing whenobstruction is encountered. Microprocessorcontrolled control unit. It should be Selflearning, with adjustable parameters for opening and closing speed, hold-open timeand opening and closing force. Class of protection IP 20.,The glasses shall be of12mm clear toughend frameless with polished edges. |
| 218 | Item includes supply installation of toughened high performance glassof thickness 12mmasper ST - 467of Saint Gobain/ Modi/ Asahi Glass or equivalent ofincluding of sealants, brackets, fasteners, screws, sieve, backer rod, bolts, gasket, fixtures, etc. complete) The above work is to be carried out by associate Specialized Agency as per approval of the Engineer-in- Charge |
| 219 | SH : X : FALSE CEILING |
| 220 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 221 | 12.5 mm thick tapered edge gypsum plain boardconforming to IS: 2095- (Part I) : 2011 (Board with BIScertification marks) |
| 222 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. |
| 223 | With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7) |
| 224 | SH : XII : FIRE FIGHTING |
| 225 | Fire Hydrant System |
| 226 | Supply, Installation, Testing & Commissioning of: Single headed, SS/ Gun Metal ISI marked oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63mm dia instantaneous type female outlet complete with Gun Metal cap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type \"A\") |
| 227 | Supply, Installation, Testing & Commissioning of: First-Aid Fire Hose Reel wall mounting swinging type complete with drum, bracket, ball valve and 20mm dia.x 30M long high pressure Hose Reel tubing as per IS:444 with Gun Metal shut-off nozzle having 5mm dia. orifice. The Hose Reel shall strictly confirm to IS : 884-1985 |
| 228 | Supply, Installation, Testing & Commissioning of: Non-percolatingflexible hose(RRL type-\"A\") ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneoustype SS/ Gun Metal 63mm dia. IS markedMale and female couplings (IS:903)bound and riveted to hose pipe with Gun Metal rivets and 1.5 mm Gun Metal wire |
| 229 | Supply, Installation, Testing & Commissioning of: SS/ Gun Metal 63mm dia short size branch pipes with 20 mm dia nozzle with 63mm instantaneous coupling ISI marked (IS: 903) |
| 230 | Providing & fixing standard fireman\"s axe with heavy insulated rubber handle. |
| 231 | Supply, Installation, Testing & Commissioning of:M.S. hose door fabricated from 16g M.S. sheet with full glass door and locking arrangement, suitable to accommodate 1 Hydrant landing valve, 1fire hose reel, 2 nos.15m long 63mmdia hose,1-branch pipe. The door shall be painted with one coat of primer and finished stove enamelled \"Fire Red\", \"Fire Hose\" written on front including suitably mounted on a raised masonry platform as required. (Approx. size 1.2m x .6m x2.1m ) |
| 232 | Supply, Installation, Testing & Commissioning of Gun Metal Fire Brigade connection (Suction collecting head) consistingof63 mm dia instantaneous type male coupling with built-in check valves and 150 mm dia. flanged outlet complete with bolts, nuts and rubber insertions as requiredas perIS:904-1983 |
| 233 | Supply, Installation, Testing & Commissioning of: M.S. cabinet (toenclose above. Draw-out/Fire brigade inlet connections)fabricated from 16 g sheet with full front glassdoor and locking arrangement duly painted with one coatof primer and twoormore coats of synthetic enamel paintofapprovedmake andshadeandsuitably mounted on a raised masonryplatformas required(Approx.0.6 m x 0.6 M x 0.45 M ). |
| 234 | Supply, Installation, Testing & Commissioning of: Aircushiontank(air-vessel) 250 mm dia. x 1.0 Mhigh with dishedtop, madeofminimum6 mm thick M.S. pipe/plate complete with 25mm dia. BrassAirValve (Ball valve, pressure gauge type),25 mmdia.Stop withbrassstop cock, nipple,tees, elbow, pipe and allaccessories as requiredincl. fixing brackets. |
| 235 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING of Mild Steel pipe (IS:1239 Part-I) heavy class including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc.including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. |
| 236 | a) 200 mm diaIS 1239 |
| 237 | b) 150 mm diaIS 1239 |
| 238 | c) 100 mm diaIS 1239 |
| 239 | d) 80 mm diaIS 1239 |
| 240 | e) 50 mm diaIS 1239 |
| 241 | f) 25 mm diaIS 1239 |
| 242 | Supply, Installation,Testing & Commissioning of: MildSteelblack pipe (IS:1239 Part-1) heavy class including cutting, screwing, welding etc.complete with fitting viz. tees elbow, bends, flanges, reducers.etc including providing anti-corrosive treatment (coating & wrapping) with 4mm thick tape and holiday test check as per IS: 10221complete as required including necessary excavation, refilling etc. complete. |
| 243 | a) 150 mm dia |
| 244 | b) 100 mm dia |
| 245 | Supply, Installation, Testing & Commissioning ofslim seal dual type non-returnvalves (PN 1.6) complete withmatching flanges, rubberinsertion,nuts, bolts and washer etc. of following sizes. |
| 246 | a) 150 mm dia |
| 247 | Providing and fixing Slim seal Butterfly valves (PN 1.6) completewith matching flanges rubber insertion, nuts. bolts andwasher etc. of following sizes |
| 248 | a) 150 mm dia nominal bore |
| 249 | AUTOMATIC SPRINKLER SYSTEM |
| 250 | SUPPLY, INSTALLATION, TESTING. & COMMISSIONING OF: |
| 251 | ElectricalMotorDriven Fire Pumping set suitable forautomatic operation consisting ofthe following as per the specifications. |
| 252 | a) Horizontally mounted, centrifugal type single stage firepump having cast iron body, bronze impeller, stainless steel shaft& capable of delivering 1620 LPM against atotal head of 60 M complete with all accessories pressure gaugeetc. as requiredAs per approved make |
| 253 | b) Squirrel cage induction motor totally enclosed fan cooled 2900 RPM type suitable for 415 Volts+ 10% - 15% , 3 phase, 50 HZ A.C. supply of suitable capacity forthe above pump coupled with flexible coupling includingearthling as per relevant Indian Standard & specifications. |
| 254 | c) Common bed plate for mounting Pump and Motor fabricated of suitable M.S.Channel asper manufacturer\"s recommendations. |
| 255 | d) Suitable RC.C Pump-Foundations as per manufacturer\"s design and 4 nos.Dunlop (cushy foot) heavy duty Anti vibration mounting pads. |
| 256 | Diesel Engine Driven Fire Pumping set suitable for automatic operation consisting of the following as per specifications |
| 257 | a) Horizontally mounted, centrifugal type single stage/ multi-stage fire pump having cast iron body, bronze impeller,stainless steelshaft & capableof delivering 1620 lpm against a total headof60 m completewith all accessories pressure gaugeetc. as requiredAs per approved make |
| 258 | b) Water cooled TAC approvedDiesel Engine suitable for developing required BHP at 1800 RPM) for above pump complete with automatic starting mechanism, batteries, automatic battery charger unit, flexible coupling with the pump, coupling with the pump, fuel tank, silencer, exhaust pipe & allstandard accessories as required as per TAC rules including earthing, mandatory spares and tool kit. |
| 259 | c) Common bed plate for mounting Pump and Engine fabricated of suitable M.S.Channel as per manufacturer\"s recommendations. |
| 260 | d) Suitable RCC Pump foundations as per manufacturer \" s design 8 Nos Dunlop Anti-vibration (cushy foot) heavy duty mounting pads. |
| 261 | SUPPLY, INSTALLATION TESTING &COMMISSIONING OF: |
| 262 | a) Electrical Motor Driven Automatic pressurisation (Jockey) pumping set consisting of the following as per specifications. Horizontally mounted centrifugal type single/multi-stage fire pump for building pressure loss due to any leakage in the system and capable to deliver approx 180 LPM against a total head of 60 M with all accessories pressure gaugeetc. as requiredAs per approved make |
| 263 | b) Squirrel cage induction motor totally enclosed fan cooled type at 2900 RPM suitable for415 Volts + 10% - 15%3 phase. 50 HZA.C. supply of suitable capacity for the above pumpwith synchronous speed of 1500/3000RPM confirming to IS: 325 & duly coupledwith abovepumpcoupled with flexible coupling including earthling as per relevant Indian Standard and specifications. |
| 264 | c) Common bed plate for mounting Pump and Motor fabricated of suitable M.S.Channel as per manufacturer\"s recommendations. |
| 265 | d) Suitable RCC Pump foundations as per manufacturer\"s design 4 Nos Dunlop Anti-vibration (cushy foot) heavy duty mounting pads. |
| 266 | Supply,Installation,Testing & Commissioning of fire pump on terrace as per specification horizontally mounted centrifugal type for building and capable to deliver approax 450 LPM againsta total head of 35M having cast iron body.Bronze impeller, stainless steel shaft and complete with \"Y\" strainer on the suction side,butterfly valve on suction and delivery side,non return valve on delivery side and Pressure Gauge with stop G.M. Stop Valve etc. for periodical testing of the working of the pumping set and Suitable RCC Pump foundations as per manufacturer\"s design 4 Nos Dunlop Anti-vibration (cushy foot) heavy duty mounting pads including all kinds of accessories & valves required for terrace pump installation complete in all respect. |
| 267 | Supply, Installation, Testing & Commissioning of cubical typewall mounted Fire Pump Control Panel (For Terrace Pump at Roof) with One FullyAutomatic DOL Starter suitable for 450 LPM Pump Motor with over loadrelay, timer push buttons and Auto/Manual selector switch. |
| 268 | Supply, Installation, Testing & Commissioning of cubical typefloor mounted Fire Pump Control Panel (For Fire Pump Room) fabricated from14 g M.S. CRCA Sheet duly powder coated finish of approvedshade and comprising of : |
| 269 | INCOMING: |
| 270 | One 125 amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA |
| 271 | One- digital Volt Meter (0-500 V) with selector switch |
| 272 | One Set indicating lamps (LED) |
| 273 | BUS BARS OUTGOING: |
| 274 | 125 Amp TPN BUS BAR (Aluminum). |
| 275 | One - 100 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA |
| 276 | One - 40 Amp.TP + NL M.C.B. with breaking capacity 10KA |
| 277 | One - 20 Amp.DP M.C.B. with breaking capacity 10KA |
| 278 | Two Fully Automatatic Star-Delta starters suitable for two electric & jockey Pump Motor with over load relay timer push buttons and Auto/Manual selector switch |
| 279 | Four panel type Amp. meters onefor each motor with ASS. CTS etc. |
| 280 | Four sets of On/Off - LED indicating lamp. |
| 281 | Fully Automatic Diesel engine starting system complete with battery charger, 4 window annunciator, indicating lights, transformer, rectifier, timer, voltmeter ammeter, selector switches, push buttons, auxiliary relay etc. complete as required as per fire authority. |
| 282 | All interconnecting power & control wires/cables suitable size within the panel and from panel to motors diesel engine, pressure switches, level switches, cable Tray, pipes etc. including brass glands termination within fire pump house and earthing as per specifications (Power cable size shall not be less than 1Nos. 3.5 x 95 mm sq., (3.5 x 50 Sqmm) for main pumps motor and 1 No. 4x16 mm sq for jockey pump motor. |
| 283 | Slim seal dual plate type non-return valves (PN 1.6) complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes. |
| 284 | 150 mm dia |
| 285 | 100 mm dia |
| 286 | 80 mm dia |
| 287 | Slim seal Butterfly valves B 190 Class (PN1.6) complete with matching flanges rubber insertion, nuts. bolts and washer etc. of following sizes : |
| 288 | 80 mm dia |
| 289 | 100 mm dia |
| 290 | 150 mm dia |
| 291 | 200 mm dia |
| 292 | Providing and fixing Ball valve with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete: in all respects. |
| 293 | 50 mm dia nominal bore |
| 294 | Supply, fixing, testing and commissioning in position the following Y - STRAINER in Pump SuctionWater line complete with flanges etc as per specifications & drawings. |
| 295 | 150 mm dia MS pipes |
| 296 | 100 mm dia MS pipes |
| 297 | Providing and fixing resilient rubber neoprene lined single arch vibration eliminators suitable for raw water up to 450C temperature working pressure 7kg and test pressure 14 kg/ cm2. |
| 298 | 80 mm dia |
| 299 | 100 mm dia |
| 300 | 150 mm dia |
| 301 | Day Oil Tank (Rectangular) |
| 302 | Double shell M.S. fabricated of IS:226 plate of 200 liters Capacity x 8mm thick. With inlet & outlet nozzles, Control Valve, Float Valve, Pipes, Flanges, Gaskets, bolts, nuts & internal supports.(The outer shall be having 110% capacity of the inner shell) |
| 303 | Electrical Fault-isolation Modules to protect the system against wire to wire short circuits on loops, to be installed at the rate of every 3 nos. monitor modules complete as per manufacturer specifications and in an accessible location as per site, excluding wiring to Annunciation Panel, with UL/FM approval. |
| 304 | Automatic electrically operated hooter ofrequired db (min.40) capacity fire alarm, to be connected to the main fire panel and zonal sprinkler annunciation panel, complete in all respects as per requirements. |
| 305 | a) For main fire panel at the main fire pump starter |
| 306 | b) For sprinklers zonal panel at main sprinkler pump starter |
| 307 | PORTABLE CHEMICAL FIRE EXTINGUISHERS |
| 308 | Supply and fixing of ISI marked( IS : 15683 ) ABC (Dry Powder) fire extinguishers cap 10 kg (9Kg) in seamless HP steel cylinders ISI marked and approved by CCE Nagpur fitted with pressure indicating gauge, internal tube squeeze level type valves fully charged with ABC powder and pressurized by Nitrogen complete in all respects including wall suspension bracket. |
| 309 | Supply and fixing of ISI marked (IS:2878) Portable fire Extinguisher, Carbon-dioxidetype flat base including valve, dischargehose of not less than 10 mm dia. 1m long& completeinall respectsincluding initial fill with CO2 gas conforming to IS:307-1966 filled to a filling ratio ofnot morethan0.667andwallsuspension bracket. |
| 310 | Capacity 4.5 Kg |
| 311 | SH:XI :HVAC WORK |
| 312 | HVAC SYSTEM SUPPLY: |
| 313 | AIR COOLED DX SYSTEM : |
| 314 | Supply and installation of copper refrigerant piping of requiredsizes duly insulated with closed cell elastomeric insulation thickness as specified by manufacturer,as per pipe size and cabling between indoor and outdoor complete with proper supports etc for following capacity unit. All related civil work such as making hole, chasing in wall, shall be inclusive in the quoted price. |
| 315 | a) GROUND FLOOR |
| 316 | 1.0 TR WALL MOUNTED UNIT |
| 317 | 1.5 TR WALL MOUNTED UNIT |
| 318 | 2.0 TR WALL MOUNTED UNIT |
| 319 | 2.5 TR WALL MOUNTED UNIT |
| 320 | b) FIRST FLOOR |
| 321 | 1.0 TR WALL MOUNTED UNIT |
| 322 | 1.5 TR WALL MOUNTED UNIT |
| 323 | 2.0 TR WALL MOUNTED UNIT |
| 324 | 2.5 TR WALL MOUNTED UNIT |
| 325 | c) SECOND FLOOR |
| 326 | 1.0 TR WALL MOUNTED UNIT |
| 327 | 1.5 TR WALL MOUNTED UNIT |
| 328 | 2.0 TR WALL MOUNTED UNIT |
| 329 | To supply, install, test and commission UPVC drain pipes duly insulated with 6 mm thick nitrile rubber and \"U \" traps from indoor units to nearest drain point. |
| 330 | 25 mm dia. |
| 331 | 50 mm dia. |
| 332 | AIR DISTRIBUTION |
| 333 | Supplying, installing, testing and commissing of direct driven PROPELLER FANS for exhaust air as shown in drawings. Each fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate, accessories like guard, bird-screen & fixed louvers for weather protection as required. Fan selection arrangement and electrical characteristics shall be as follows. |
| 334 | 230 mm dia 1400 RPM fan suitable for 220 +(-)6% volts 50 cycles, 1 Phase AC supply |
| 335 | 300 mm dia 1400 RPM fan suitable for 220 +(-)6% volts 50 cycles, 1 Phase AC supply |
| 336 | 450 mm dia 1400 RPM fan suitable for 220 +(-)6% volts 50 cycles, 1 Phase AC supply |
| 337 | AIR DISTRIBUTION SYSTEM |
| 338 | DUCT |
| 339 | Supply, fabrication, installation, and testing of site Fabricated ducts of following thickness including necessary supports flexible hangers with isolators, nut bolts, gasket, splitter damper,duct dampers, vanes, etc. complete as per specifications in accordance with the approved shop drawings. |
| 340 | SITE FABRICATED DUCT |
| 341 | 24 gauge galvanised sheet (0.63 mm) |
| 342 | GRILLE / DIFFUSER |
| 343 | Supply, installation, testing and commissioning of terminal air distribution equipment as per approved shop drawings, colour and specifications. |
| 344 | Aluminium powder coated air grille with damper for exhaust of 150 x 150mm |
| 345 | SH : XII: PASSANGER ELEVATOR |
| 346 | Providing & Fixing Passanger elevator as per specifications |
| 347 | for thyssenkrupp Elevator (India) Pvt. Ltd. |
| 348 | SH : XIII: ELECTRICAL & COMMUNICATION WORK |
| 349 | CHAPTER-1 - W I R I N G |
| 350 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 351 | Group B |
| 352 | Wiringfortwincontrollightpointwith1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessedmediumclassPVCconduit,2waymodularswitch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mmFRLSPVCinsulatedcopperconductorsinglecorecable etc. as required. |
| 353 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium classPVC conduit alongwith1No.4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 354 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 355 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas required. |
| 356 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 357 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 358 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 359 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 360 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 361 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 362 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 363 | 2 Pair |
| 364 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 365 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 366 | 20 mm |
| 367 | 25 mm |
| 368 | 32 mm |
| 369 | 40 mm |
| 370 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 371 | Telephone socket outlet |
| 372 | TV antenna socket outlet |
| 373 | Bell push |
| 374 | Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 375 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 376 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 377 | 1 or 2 Module (75mmX75mm) |
| 378 | 3 Module (100mmX75mm) |
| 379 | 4 Module (125mmX75mm) |
| 380 | 6 Module (200mmX75mm) |
| 381 | 8 Module (125mmX125mm) |
| 382 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 383 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 384 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 385 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connectionsetc. as required. |
| 386 | Supplyingandfixingcallbell/buzzersuitableforsinglephase,230 V, complete as required. |
| 387 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 388 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 389 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 390 | Upto 450 mm sweep |
| 391 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 392 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 393 | 1 run of cable |
| 394 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductorsinglecorecableinsurface/recessedPVCconduit, andearthingthepointwith1.5sq.mmFRLSPVCinsulated copper conductor single core cable etc. as required. |
| 395 | Group B |
| 396 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 397 | CHAPTER-2-MCCB, MCB & DB’S |
| 398 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 399 | 12 way , Double door |
| 400 | Supplyingandfixingfollowingway,horizontaltypethreepole andneutral,sheetsteel,MCBdistributionboard,415V,on surface/recess,completewithtinnedcopperbusbar,neutralsurface/recess,completewithtinnedcopperbusbar,neutral includingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator) |
| 401 | a) 4 way (4 + 12), Double door |
| 402 | b) 6 way (4 + 18), Double door |
| 403 | c) 8 way (4 + 24), Double door |
| 404 | Supplyingandfixing5Ato32A rating, 240/415V, 10kA,\"C\" curve,miniaturecircuitbreakersuitableforinductiveloadof followingpolesintheexistingMCB DBcompletewith connections, testing and commissioning etc. as required. |
| 405 | a) Single pole |
| 406 | b) Double pole |
| 407 | c) Triple pole and neutral |
| 408 | Supplyingandfixingsinglepoleblankingplateintheexisting MCB DB complete etc. as required. |
| 409 | Supplying and fixing following rating, double pole, (single phase andneutral),240V,residualcurrentcircuitbreaker(RCCB),havingasensitivitycurrent30mAintheexistingMCBDBcompletewithconnections,testingandcommissioningetc.as required. |
| 410 | a) 25 A |
| 411 | b) 40 A |
| 412 | Providing and fixing M.V. danger notice plate of 200 mm X 150mm,madeofmildsteel,atleast2mmthick,andvitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 413 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc.as required. |
| 414 | a) For 4 way, Double door TPN MCB DB |
| 415 | b) For 6 way, Double door TPN MCB DB |
| 416 | c) For 8 way, Double door TPN MCB DB |
| 417 | CHAPTER-4-CABLE TRAYS |
| 418 | Hot Dipped Galvanized Iron Cable Tray |
| 419 | Supplying and installing following size of perforatedHot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenientsections,joinedwithconnectors,suspendedfrom the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 420 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 421 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \"bends\" (galvanisation not lessthan 50microns)withperforation notmore than 17.5%, in convenientsections,joinedwithconnectors,suspendedfrom the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 422 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 423 | Supplying and installing following size of perforated Hot Dipped GalvanisedIroncable tray \"Tee\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joinedwithconnectors,suspendedfromtheceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 424 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 425 | CHAPTER - 5 - E A R T H I N G |
| 426 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories,andprovidingmasonryenclosurewith coverplatehavinglockingarrangementandwateringpipeof 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 427 | Earthingwithcopperearthplate600mmX600mmX3mm thickincludingaccessories,andprovidingmasonryenclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 428 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipefromearthelectrodeincludingconnectionwithbrassnut,bolt, spring, washer excavation and re-filling etc. as required. |
| 429 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipefromearthelectrodeincludingconnectionwithG.I.nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 430 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 431 | Providingandfixing25mmX5mmG.I.striponsurfaceorin recess for connections etc. as required. |
| 432 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 433 | CHAPTER 6 - LIGHTNING CONDUCTOR |
| 434 | Providingandfixingoflightningconductorfinial,madeof25 mm dia 300 mm long, G.I. tube, having single prong at top, with85mmdia6mmthickG.I.baseplateincludingholesetc.complete as required. |
| 435 | Fixing of lightning conductor finial (single prong) with base plateincluding holes etc. complete as required. |
| 436 | Jointing copper / G.I. tape (with another copper/ G I tape, baseofthefinialoranyothermetallicobject)byriveting/nutbolting/ sweating and soldering etc as required. |
| 437 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor completeas required.(For horizontal run) |
| 438 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete as required.(For vertical run) |
| 439 | Providing and fixing testing joint, made of 20 mm X 3 mm thickG.I.strip,125mmlong,with4nos.ofG.I.bolts,nuts,chuck nuts and spring washers etc. complete as required. |
| 440 | ProvidingandlayingG.I.tape32mmX6mmfromearth electrode directly in ground as required. |
| 441 | CHAPTER 7 - MV CABLE LAYING |
| 442 | Laying ofone numberPVC insulated and PVC sheathed/ XLPE powercableof1.1KVgradeoffollowingsizeintheexisting RCC/ HUME/ METAL pipe as required. |
| 443 | a) Upto 35 sq. mm |
| 444 | b) Above 35 sq. mm and upto 95 sq. mm |
| 445 | c) Above 95 sq. mm and upto 185 sq. mm |
| 446 | CHAPTER 8-HT CABLE LAYING |
| 447 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 11 KV grade of following size direct in groundincluding excavation, sand cushioning, protective covering andrefilling the trench etc as required. |
| 448 | Upto 120 sq. mm |
| 449 | CHAPTER 9-MV CABLE JOINTING & END TERMINATION |
| 450 | Supplying and making end termination with brass compression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 451 | a) 3½ X 35 sq. mm (32mm) |
| 452 | b) 3½ X 50 sq. mm (35mm) |
| 453 | c) 3½ X 70 sq. mm (38mm) |
| 454 | d) 3½ X 185 sq. mm (57mm) |
| 455 | CHAPTER-10- FIRE DETECTION AND ALARM SYSTEM |
| 456 | INTELLIGENT FIRE ALARM SYSTEM |
| 457 | Supplying,installation,testingandcommissioningofmicro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (includingdetectors)andminimum120detectorsperloop andlooplengthupto2km,networkcommunicationcard, minimum320charactergraphics/LCDdisplaywithtouch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuationsystem(whichispartofthescheduleofwork under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 458 | a) Two Loop Panel. |
| 459 | Supplying, installation, testing & commissioningof intelligent analogaddressablephotothermaldetectorcompletewith mounting base complete as required. |
| 460 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 461 | Supplying, installation, testing & commissioningof addressable manual call point complete as required. |
| 462 | Supplying, installation, testing & commissioningof addressable horn cum strobe complete as required. |
| 463 | PUBLIC ADDRESS SYSTEM |
| 464 | Supplying,installation,testing&commissioningof6zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 465 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 466 | Supplying,installation,testing&commissioningofdigital audioamplifier75Watt,25Vrmsoperatingat240VoltAC Supply complete as required. |
| 467 | Supplying, installation, testing & commissioning of Voice commandkeypad6zone,withmicrophoneassembly complete as required. |
| 468 | CABLING & WIRING |
| 469 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000Vratedwithannealedcopperconductorhaving XLPEinsulation,steelwirearmouring&FRLSoutersheath complete as required. |
| 470 | speaker cable Single pair, 2-core, 1.5 sqmm |
| 471 | NON DSR ITEMS |
| 472 | Fixture |
| 473 | Supply of below mentioned Items- |
| 474 | a) 36Watt Square LED Natural Light |
| 475 | b) 12 Watt LED Light |
| 476 | c) 1200 MM Ceiling Fan |
| 477 | d) 225mm Exaust fan |
| 478 | e) Data Socket(RJ-45 CAT6) (Legrand Myrius) |
| 479 | Make: |
| 480 | Light- Philips |
| 481 | Fan -Havells |
| 482 | Supply of HT/ LTCABLES |
| 483 | Supply offollowing 1100 voltgradeXLPE insulated PVC inner sheathed and FR PVC outer sheathed Aluminium conductor armoured LT cables .(Make: Cable- GuptaPower, Polycab, RR Kabel, Havells ) |
| 484 | 3.1/2 core 185 sq. mm. |
| 485 | 3.1/2 core 70 sq.mm |
| 486 | 3.1/2 core 50 sq.mm |
| 487 | 3.1/2 core 35 sq. mm |
| 488 | Supply of LTPANEL |
| 489 | (Make: L & T) |
| 490 | MAIN LT PANEL with AMF |
| 491 | INCOMER |
| 492 | 400A, FP, MCCB ,36 KA (2 Nos.) |
| 493 | METERING & INDICATION with each incomer |
| 494 | -ON/OFF phase indicating lamps with control fuses . |
| 495 | - Multifunction Meter with CT\"s |
| 496 | BUS BAR |
| 497 | \"800 A, TPN, Al Bus Bars with heat shrinkable PVC Sleeves |
| 498 | OUTGOINGS |
| 499 | 100 A, FP, MCCB, 16 Ka – 12 Nos |
| 500 | 63 A, FP, MCCB, 16 Ka – 2 Nos |
| 501 | 63 A, FP, MCB–2 Nos |
| 502 | All MCCB\"s should with Extended Rotary Handle and Spreader terminals |
| 503 | Cable Entry from Top. |
| 504 | Supply of Building LT PANEL -as described above |
| 505 | Supply installation Testing and commissioning of120 KVAr with 6 stage relay |
| 506 | Supply ofUPS |
| 507 | Supply installation Testing and commissioning of .......... KVA on line UPS system as per IEC 62040-I(Safety) ,IEC 62040-3(Performance) for critical IT solutions ,fully digital IGBT Converter and Inverter ,with Internal /External isolation transformer from DC to AC, PWM, pure sine wave out put, double conversion ,output pf 0.9, with parallelling facility , standard communicaton features/options auto and manual static by pass switch three phase input / Three phase output. Accoustic level shall be less than 58dB at 1 mtr distance.Makes: Numeric/APC/Consul Neowatt/Sakshham /Emerson |
| 508 | 20.0 KVA 312/360 V DC |
| 509 | Supply of Transformer |
| 510 | Supply, Installation, Testing and commissioning of copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. |
| 511 | 250 KVA |
| 512 | Supply of DG |
| 513 | SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start, Batteries, Fuel tank ( with Stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183 .The doors are fabricated from 1.6 mm CRCA sheet packed with accoustic material, floor of MS chequrred plate 5.0 mmthick, All doors/ opening are sealed with neoprene/ EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 °C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system mccb Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. Lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 db (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity : Radiator cooled and turbo charged ( AMF include in the LT panel) |
| 514 | 250KVA at 0.8 pf 415V 50Hz 3-Ø |
| 515 | Two Pole Structure |
| 516 | Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications: |
| 517 | DP :double pole structure on 2no ISMB 125mm 10 mtr high pole or 2no PCC pole 10 mtr high using 7 no MS channel each of size 75mmx50mmx2500mm complete in all respect with nuts, springs ashers, clamps as required |
| 518 | GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9nos pin insulator ,GI pipe of suitable length for operation. |
| 519 | DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators |
| 520 | LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. |
| 521 | JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ |
| 522 | (SH-XIV:- Boundary wall ) Details of cost for 320.00 Mtr. |
| 523 | Earth work in excavation in foundation and trenches in soils containing 50% ormore of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 524 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 525 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: |
| 526 | a) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 527 | Reinforcement cement concrete work in columns, pillars,piers,abutments, post and struts etc upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. |
| 528 | a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 529 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar1:3 (1cement:3finesand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 530 | a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 531 | Centring and shuttering including strutting, propping etc and removal of form work for |
| 532 | a) Lintels, beams, girders, bressumers and cantilevers etc. |
| 533 | b) Column, pillars, posts and struts etc. |
| 534 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 535 | b) Tar/TMT steel |
| 536 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 537 | Extra for half brick masonary in superstructure above floor two level. |
| 538 | Providing and fixing MS grills of required pattern in wooden frames of windows etc. With MS flat, square or round bars with round headed bolts and nuts or by screws. |
| 539 | a) Plain grill |
| 540 | 12 mm cement plaster 1 : 6 (1 cement : 6 fine sand). |
| 541 | Colour washing such as green, blue or buff on new work (two or more coats) including a base coat of white washing with lime to give an even shade |
| 542 | SH- XV:- STEEL GATE AND CATTLE TRAP |
| 543 | Earth work in excavation in foundation and trenches in soils containing 50% ormore of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 544 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 545 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: |
| 546 | a) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 547 | Reinforcement cement concrete work in columns, pillars,piers,abutments, post and struts etc upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. |
| 548 | a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 549 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar1:3 (1cement:3finesand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 550 | a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 551 | Centring and shuttering including strutting, propping etc and removal of form work for |
| 552 | a) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 553 | b) Lintels, beams, girders, bressumers and cantilevers etc. |
| 554 | c) Column, pillars, posts and struts etc. |
| 555 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 556 | b) Tar/TMT steel |
| 557 | Providing and fixing MS Gate / grills of required pattern with MS flat, square or round barswith roundheaded boltsand nuts or by screws. MS Steel Gate and Cattle Trap (3.50M wide) |