Addition / Alteration And Provn Of Basic Amenties To Certain Smqs / Omqs, Ac For Briefing Hall, Deficient Electric Meters At Various Locations And Dg Set At Air Force Station Pathankot Addition / Alteration And Provn Of Basic Amenties To Certain Smqs / , GE (AF) PATHANKOT-Punjab

Military Engineer Services-MES has published Addition / Alteration And Provn Of Basic Amenties To Certain Smqs / Omqs, Ac For Briefing Hall, Deficient Electric Meters At Various Locations And Dg Set At Air Force Station Pathankot Addition / Alteration And Provn Of Basic Amenties To Certain Smqs / . Submission Date for this Tender is 15-01-2022. Diesel Generators Tenders in GE (AF) PATHANKOT Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

30352027
Corrigendum : Addition / Alteration And Provn Of Basic Amenties To Certain Smqs / Omqs, Ac For Briefing Hall, Deficient Electric Meters At Various Locations And Dg Set At Air Force Station Pathankot Addition / Alteration And Provn Of Basic Amenties To Certain Smqs /
Open Tender
Indian
Punjab
GE (AF) PATHANKOT
15-01-2022

Tender Details

Addition / Alteration And Provn Of Basic Amenties To Certain Smqs / Omqs, Ac For Briefing Hall, Deficient Electric Meters At Various Locations And Dg Set At Air Force Station Pathankot Addition / Alteration And Provn Of Basic Amenties To Certain Smqs / Omqs, Ac For Briefing Hall, Deficient Electric Meters At Various Locations And Dg Set At Air Force Station Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Dec-2021 Corrigendum Other 08-01-2022
2 08-Jan-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-01-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

Name of Work : ADDITION/ALTERATION AND PROVN OF BASIC AMENTIES TO CERTAIN SMQs/OMQs, AC FOR BRIEFING HALL, DEFICIENT ELECTRIC METERS AT VARIOUS LOCATIONS AND DG SETAT AIR FORCE STATION PATHANKOT
Sl. No. Item Description
1Supply and fixing energy efficient water heater storage type, electric supplied and installed complete incl all PVC connection for hot and cold water & CP connections and havingtank of capacity 25 litres, incl suitable size of iron anchor bolt for fixing the new geyser complete all as specified and directed by Engineer-in-charge.
2Supply and fixing bib taps 15mmfency type with crutch or butterfly handle, screwed down screwed for GI pipe complete all as specified and directed by Engineer-in-charge.
3Supply and fixing stop valve 15mm fency type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for GI pipe complete all as specified and directed by Engineer-in-charge.
4Supply and fixing GI tubing pipes galvanized, "Medium class", supplied and laid complete including fittings 15 mm (1/2") dia complete all as specified and directed by Engineer-in-charge.
5Cutting of Existing water supply main any size upto 25 /20 mm for Taking branch connection for taking branch connection of size 15 mm including insertion of Tee unegual all as required at site or directed by Engr-in-Charge.
6Supply and fixing Switch piano flush button single pole one way 15 amp 230 Volts complete all as specified and directed by Engineer-in-charge.
7Material and labour for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 voltsc complete all as specified and directed by Engineer-in-charge.
8Material and labour for MCB single pole 240 volts 16 amps, with rupturing capacity 10 KA, complete all as specified and directed by Engineer-in-charge.
9Material and labour forsubmain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 2.5 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit 2mm thickness ISI marked cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge.
10Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit 2mm thicknesswith all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified and directed by Engineer-in-charge.
11Material and labour for ceiling rosesurface bakelite 2 to 3 terminals complete all as specified and directed by Engineer-in-charge.
12Material and labour for switch piano flush button single pole one way 5 amps 240 voltscomplete all as specified and directed by Engineer-in-charge.
13Supply and fixing exhaust fan 300 mm sweep steel body single phase 230 volts 50 Hz AC,totally enclosed mounted on two ball bearings complete with louvers & shutters including making of suitable size of hole for fixing of ex fan,cutting chases to wall making good the disturbed surfaces to match with theexisting specification, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site or directed byEngr- in Charge
14Supply, installation,testing of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 as per IS: 13364 complete comprising ofAIR cooled Diesel Engine (CPCB NORMS COMPLIANCE) developing 10 BHP @1500 RPM & 7.5 KVA KOEL Greenmake Alternator rated at 3 Phase ,415 Volts,50 Hz 0.8 p.f @ 1500 RPM both mounted ,and alignedon a common MS base frame complete with MS fuel tankIntegrated controll panel,Residential Exhaust silencer,AVMPads fitted on base frame ,1 No. 12 Volts DC batteryLeads,1st fill of lube oil .and other featuresincluding foundation (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB norms of capacity complete all as specified and directed by Engineer-in-charge.
15Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engineer-in-charge.
16Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deepand getting out in soft/loose ofsoil for laying of pipes etc complete all as specified and directed by Engineer-in-charge.
17Returning, filling in(soil) including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickcomplete all as specified and directed by Engineer-in-charge.
18Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-charge.
19Sub Class"B" bricks laid dry flatto cover the cable with width equal to the length of cable and abutting each other for protection of cable complete all as specified and directed by Engineer-in-charge.
20Sand cushioning to undergroundcables providing a layer of 8cm thick before laying the cable and 15cm thick after laying,stretching and testing the cable complete all as specified and directed by Engineer-in-charge.
21Supply, installation, commissioning and testing CPRI approved LT panel of suitable size recommended by manufacturercubical floor mounted type (IP-55 degree of protection ) made out of3.15mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 100 amps rating made of copper strip duly drilled holes for connections and mounted on epoxy based post insulatorsfor 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including the following (i) On load Change over switch 4 pole , 63 Amp 415 Volt front operated (ii) MCCB 4 pole 415 volts with thermal magnetic releaserupturing cap 25 KA, 63 amps - 01 Nos for incoming) (iii) MCB ,SPN40 amps-3 Nos( for outgoing) (iv)Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio (v) RYB LED indicating lamp- 01 No
22Earthingcompletewith galvanisedsteelearthplateelectrode 600x600x6mm burrieddirectlyin groundnotless than2.25mtr deepbelow normal ground level with top edgeof earth plate not less than 1.5mtrbelow normal ground level connected to the Galvanised iron strip 32x6mm sizeby meansof bolts ,nuts,check nutsandwashersof galvanisediron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm boreincl provision of concrete pit in PCC1:2:4 typeB-i, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPMweight not less than 4 Kg /Sqm and 6mm diabar handle ,excavationand earthworkin any type of soil ,charcoaldustand saltlightgrade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GIprotectionpipe 15mm bore 5 Mtr long and GI strip upto main earthingof polecomplete all as shown in electrical plateNo 5 of MES Sch 191 Part-I all as specifiedand directed . (i) Main earthing lstrip from earth plate electrode to test point upto length of 7.5 meters length shalldeem to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 metre shall be measured and paid for seperately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
23Supply and install in wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality of capacity 1.5 Ton complete all as specified and directed by Engineer-in-charge.
24Submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 6.0 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in & including concealed rigid metallic steel conduit 2mm thick ISI Marked cutting chases to wall for laying conduit and making good the distrubed wall surfaces to matdch with existing specificaiton complete all as specified and directed by Engineer-in-charge.
25Supply and fixing electronic meters temper proof LCD display with polycarbonate cover 230V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed by Engineer-in-charge.
26Supply and fixing meter box suitable for fixing of one meters with locking arrengement of suitable size including complete all as specified and directed by Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail