}

Comprehensive And Preventive Maintenance Of Various Laundry Plants Boilers And Equipment Including Connected Items At Ahrr Under Ge E / M Rrh Delhi Cantt 110010- 1 M &L For Comprehensive, Preventive And Periodical Maintenance Of Various Equipments, GE EM RR HOSPITAL-Delhi

Military Engineer Services-MES has published Comprehensive And Preventive Maintenance Of Various Laundry Plants Boilers And Equipment Including Connected Items At Ahrr Under Ge E / M Rrh Delhi Cantt 110010- 1 M &L For Comprehensive, Preventive And Periodical Maintenance Of Various Equipments. Submission Date for this Tender is 14-01-2022. Kitchen Equipment Tenders in GE EM RR HOSPITAL Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

30340862
Corrigendum : Comprehensive And Preventive Maintenance Of Various Laundry Plants Boilers And Equipment Including Connected Items At Ahrr Under Ge E / M Rrh Delhi Cantt 110010- 1 M &L For Comprehensive, Preventive And Periodical Maintenance Of Various Equipments
Open Tender
Indian
Delhi
GE EM RR HOSPITAL
14-01-2022

Tender Details

Comprehensive And Preventive Maintenance Of Various Laundry Plants Boilers And Equipment Including Connected Items At Ahrr Under Ge E / M Rrh Delhi Cantt 110010- 1 M &L For Comprehensive, Preventive And Periodical Maintenance Of Various Equipments Of Laundry Plantscomprising Of Opening, Dismantling Of The Washer Extractor Machine Using Adequate Labour And Disconnecting All Steam / Water Connection And Electrical Connection, Cleaning / Servicing Of Steam Heating Coil, Steam Trap, Installed In Main Bldg Ahrr Complex As Mentioned Here-In-After, In Reliable, Safe. Smooth, Healthy And Efficient Manner Using Latest Techniques & Oem Guidelinefor Daily / Monthly / Quaterly / Half Yearly / Yearly Maintenance / Servicing / Lubricating / Greasing And Adjusting The Mechanical And Electrical Driving Equipment, Shaft Assembly ( Filling Extra Material Filling / Including Granding , Welding , Reviting ) , Bearing / Contact, Governor Jaws In And Including Change Of Lubricating Oil, Grease, All Rubber Gaskets / Packing Of All Equpment And Oil Seales As Per Oem Priscription Andreplacement Of Kinds Of Minordefective / Spares Parts I.E. Wire, Lugs, Nut, Bolts, Screw Etc And All Machine Work I.E. Welding, Cutting, Drilling Etc As And When Required, In And Including Repair / Replacement Of Defective Spares Parts Mentioned In Sch – ‘A’ As Supply OnlyTo Entire Satisfaction Of Engineer -In- Charge, Complete All As Specified Anddirected By Engr-In-Charge For Followinglaundry Equipments- ( A ) Washer Extractor Upto 120 Kg Capacity Of– 02 Nos ( B ) Washer Extractor Upto 60 Kg Capacity Of– 01 Nos ( C ) Washer Extractor Upto 100 Kg Capacity Of – 03 Nos ( D ) Flat Work Ironer Machine Of -02 ( E ) Flat Bed Press Of -04Thecomprehensive / Preventive / Periodical Maintenance Includes. The Complete Records Of The Replased Spare Parts, Other Than Mentioned In Sch A , Will Be Maintained And Will Be Produced To Engineer-In Charge On Monthaly Basis Or As And When Asked To Produced The Same. All The Complaint ( S ) Will Be Addressed Within 02 Hrs From The Time Of Receipt Of Complaint. If, Contractor Or His Tradesmen Fails To Attend The Complaint Within 02 Hrs From The Time Of Receipt Of Complaint, The Compensation / Penalty Of Rs. 500.00 ( Rupees Five Hundred Only ) Per Complaint Per Hr For First 04 Hrs And After That Rs. 1000.00 ( Rupees One Thousand Only ) Per Complaint Per Hr Shall Be Recovered From The Contractor’S Dues. All The Complaint ( S ) Is Required To Be Rectify Within 24 Hrs Or Within Stipulated Time Given By The Je / Engineer-In-Charge. If, Contractor Or His Tradesmen Fails To Rectify The Defect, The Compensation Of Rs. 500.00 ( Rupees Five Hundred Only ) Per Complaint For Each Day ( I.E. 24 Hours ) Shall Be Recovered From The Contractor’S Dues. The Decision Of Accepting Officer In This Regard Shall Be Final And Binding. The Cost Of Transportation ( To And Fro ) And Other Necessary Equipment Shall Be Arranged / Brought By Contractor To Complete The Job And No Extra Cost Shall Be Paid To The Contractor In This Effect. The Cost Of Balancing / Alignment Of Cylindrical Basket, Remattling The Shaft By Taking It To The Lathe Work Shop Complete All As Specified Anddirected By Eic For Above Mentionedlaundry Equipments. 2 Supply And Fixing, In Replacement Of Main Bearing Set Of Size ( 6322, 2Rs And 6323, 2Rs ) Suitable For Washer Extractor Of 120 Kg Capacityid-125, Od -160 And Thickness 13 Mm Complete All As Specified Anddirected By Engr-In-Charge. 3 Supply And Fixing, In Replacement Of Main Bearing Seal Set Of Silicon Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 4 Supply And Fixing, In Replacement Of Main Bearing Circlip Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 5 Supply & Fixing, In Replacement Of Display Controller ( Axw ) Suitable For Washer Extractor Of 120 / 60 Kg Capacity Fabcare / Stefab Complete All As Specified And Directed By Engr-In-Charge. 6 Supply Only, In Replacement Of Main Water Inlet Valve / Main Drain Valve ( Actuator Butterfly Valve ) Of Size 100 Mm Suitable For Washer Extractor Of 120 Kg Capacitycomplete All As Specified And Directed By Engr-In-Charge. 7 Supply Only, In Replacement Of Main Steam Inlet Solenoid Valveof Size 25 Mmsuitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. Make Will Be As Perexisting Valve. 8 Supply Only In Replacement Of V-Belt Of Size B-128 Complete Set ( 05 Nos ) Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 9 Supply Only In Replacement Of Ss Flexible Hose, Pressure / Temp Rating 7 Kg / Cmsqure / 1000 Digricentigrate Ofsize1 Dia And 2.5 M Long For Steam Inlet Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. Make As Per Existing Sample. 10 Supply And Fixing, In Replacement Of Ss Flexible Hose, Pressure / Temp Rating 7 Kg / Cmsqure / 1000 Digricentigrate Ofdia 2 And 2.5 M Longfor Water Inlet Suitable For Washer Extractor Of 120 Kg Capacity , Complete All As Specified And Directed By Engr-In-Charge. Make As Per Sample. 11 Supply Only, In Replacement Ofpvc Pneumatic Pipecomplete All As Specified And Directed By Engr-In-Charge. 12 Supply Only, In Replacement Of Pvc Pneumatic Pipe Fitting I.E. Tee, Elbow, Connector Etc , Complete All As Specified And Directed By Engr-In-Charge. 13 Supply Only V-Belt Of Size A-57Suitable For Flat Work Ironer Machine Complete All As Specified And Directed By Engr-In-Charge. 14 Supply Only, In Replacement Of Ss Flexible Hose Of 2 ¼ Size, 1 M Long Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 15 Supply Only, In Replacement Of Rubber Hose Pipe Of 4 Size, 1 M Long Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 16 Supply Only, In Replacement Of Pneumatic Frl Set Suitable For Washer Extractor Of 120 Kg Capacity / Flat Work Ironer Machinecomplete All As Specified And Directed By Engr-In-Charge. 17 Supply Only, In Replacement Of Ln Key Bolt For Main Housing Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 18 Supply Only, In Replacement Solenoid Valve Suitable For Washer Extractorany Capacitytape Complete All As Specified And Directed By Engr-In-Charge. 19 Supply Only, In Replacement Of Pneumatic Cylinder Door Lock Suitable For Washer Extractor Of 100 / 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 20 Supply Only, In Replacement Of Main Shocker Suitable For Washer Extractor Of 120 Kg Capacity Including Nut, Bolt And Washer Complete All As Specified And Directed By Engr-In-Charge. 21 Supply Only, In Replacement Of Main Spring Heavy Duty Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 22 Supply Only, In Replacement Of Door Lock Latch Handle Suitable For Washer Extractor Of 120 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. As Per Existing Sample. 23 Supply Only, In Replacement Of Thermo Couple Suitable For Flate Bed Press / Washer Extractor Of 100 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. Make : As Per Existing Sample. 24 Supply Only, In Replacement Of Flannel Cloth Suitable For Flat Work Ironer Machine Complete Including Anchoring Iron Rod Clip Complete All As Specified And Directed By Engr-In-Charge. As Per Existing Sample. 25 Supply Only, In Replacement Of Final Cover Suitable For Flat Work Ironer Machine Complete All As Specified And Directed By Engr-In-Charge.As Per Existing Sample. 26 Supply Only, In Replacement Of Conveyor Beltswith Hook & Pin Suitable For Flat Work Ironer Machine Complete All As Specified And Directed By Engr-In-Charge. As Per Existing Sample. 27 Supply Only, In Replacement Of Guide Tape Suitable For Flat Work Ironer Machine Complete All As Specified And Directed By Engr-In-Charge.As Per Existing Sample. 28 Supply Only, In Replacement Of Main Bearing Set Roller Suitable For Flat Work Ironer Machine Complete All As Specified And Directed By Engr-In-Charge. 29 Supply Only, In Replacement Of V-Belt Of Size A-46 Suitable For Flat Work Ironer Machine Complete All As Specified And Directed By Engr-In-Charge. 30 Supply Only, In Replacement Of Temperature Meter Of Dia 2 And Temp Rating 0-200 Digricentigrate For Flat Work Ironer Machine Complete All As Specified And Directed By Engr-In-Charge. 31 M&L For Comprehensive Maintenance / Over Hauling Of Drying Trumler Of Capacity 50 / 60 Kg ( Make - Fabcare / Stefab ) , Comprising Of Opening, Dismantling Of The Machine Using Adequate Labour And Disconnecting All Steam / Water Connection And Electrical Connection, Balancing / Alignment Of Cylindrical Basket, Remattling The Shaft By Taking It To The Lathe Work Shop, Cleaning / Servicing Of Steam Heating Coil, Steam Trap, Replacing All Defective Spares Parts / Items Mentioned In Price Schedule As Supply Only And Reassembling All Dismantled Part / Items After Carrying Out Necessary Repair As Required, Including Cleaning, Servicing, Oiling, Greasing Etc, Making All Water / Steam Connection And Electrical Connection, Leak Testing At Desired Pressure, With And Including Testing, Commissioning Of Drying Trumbler Machine At Optimum Efficiency As Per Service Manual Or As Per Manufacturer Standard, Complete All As Specified And Directed By Engr-In-Charge. And Required At Site. ( A ) Drying Trumblern 60 Kg Make- Fabcare-04 ( B ) Drying Trumblern 50 Kg Make-Stebfab-03Note:-The Cost Of Transportation ( To & Fro ) Is Deemd To Be Included In Quoted Rates. 32 Supply Only, In Replacement Of Steam Heating Coil Having Copper Tube With Aluminium Fins Suitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 33 Supply Only, In Replacement Of V-Belt Of Size A-102 Of Main Drivesuitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 34 Supply Only, In Replacement Of V-Belt Of Size B- 82 Suitamle For Ideler Drivesuitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 35 Supply Only, In Replacement Of Steam Trap Suitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 36 Supply Only, In Replacement Of Main Drive Bearing Of Size-2210Alongwith Sleeves Suitable For Drying Tumblers Of 50 / 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 37 Supply Only, In Replacement Of Idler Drive Bearing Of Size-2213 Alongwith Indler Sleeves Suitable For Drying Tumblers Of 60 Kg Capacitycomplete All As Specified And Directed By Engr-In-Charge. 38 Supply Only, In Replacement Of Door Latches For Lint Screen Suitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 39 Supply Only, In Replacement Of Door Limit Switch Suitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 40 Supply Only, In Replacement Of Main Door Lock Suitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 41 Supply Only, In Replacement Of Timer 0-60 Sec Time Delay Suitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 42 Supply Only, In Replacement Of Timer Rev-Fwd Action Suitable For Drying Tumblers Of 60 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 43 Supply Only, In Replacement Of Digital Temperature Controller Suitable For Drying Tumblers Of 60 Kg Capacity / Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 44 Supply Only, In Replacement Of Padding Set Suitable For Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 45 Supply Only, In Replacement Of Main Bearing Suitable For Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 46 Supply Only, In Replacement Of Flow Control Valve Of Size 1 / 2 Inch ( 15Mm ) Suitable For Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 47 Supply Only, In Replacement Of Air Valve Of Size 15 Mm For Manual Control Suitable For Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 48 Supply Only, In Replacement Of Steam Supply Valve Of Size 20 Mm Suitable For Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 49 Supply Only, In Replacement Of Steam Trap Td-3 Type Of Size 25 Mm Suitable For Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 50 Supply Only, In Replacement Of Timer Gic Type Suitable For Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 51 Supply Only, In Replacement Of Ss Flexible Steam Inlet Pipe Of Size 20 Mm Suitable For Flat Bed Presscomplete All As Specified And Directed By Engr-In-Charge. 52 Supply Only, In Replacement Of White Nipples Suitable For Flat Bed Press Complete All As Specified And Directed By Engr-In-Charge. 53 Supply Only, In Replacement Of Red / Green Push Button, Complete All As Specified And Directed By Engr-In-Charge. 54 Supply Only, In Replacement Of Indicator Lamp, Complete All As Specified And Directed By Engr-In-Charge. 55 M&L For Comprehensive Maintenance / Overhauling Of Hydro Extractor Capacity Of 25 Kg ( Make - Stefab ) , Comprising Of Opening, Dismantling And Disconnecting All Electrical Connection, Balancing / Alignment Of Cylindrical Basket, Balancing Of Blower, Shaft Turning, Cleaning / Servicing Of Steam Radiator, Replacing All Defective Spares Parts / Items Mentioned In Price Schedule As Supply Only. The Work Include Taking Down Of 3 Ph Induction Drive Motor And Neccessary Turning & Grinding Of Motor Rotor And Reassembling All Dismantled Part / Items After Carrying Out Necessary Repair As Required, Including Cleaning, Servicing, Oiling, Greasing Etc, Making All Water Connection And Electrical Connection, Leak Testing At Desired Pressure, With And Including New Control Wiring And Testing, Commissioning Of Hydro Extracor At Optimum Efficiency As Per Service Manual Or As Per Is Standard, Complete All As Specified And Directed By Engr-In-Charge. 56 Supply Only, In Replacement Of, Transformer Of 15 Amp Capacity Suitable For Hydro Extractor Of 25 Kg Capacitycomplete All As Specified And Directed By Engr-In-Charge. 57 Supply Only, In Replacement Of Buffer Suitable For 25 Kg Hydro Extractor Complete All As Specified And Directed By Engr-In-Charge. 58 Supply Only, In Replacement Of Oil Seal Suitable For 25 Kg Hydro Extractor Complete All As Specified And Directed By Engr-In-Charge. 59 Supply Only, In Replacement Of Limit Switch Suitable For 25 Kg Hydro Extractor Complete All As Specified And Directed By Engr-In-Charge. 60 Supply Only, In Replacement Of Spring Suitable For 25 Kg Hydro Extractor Complete All As Specified And Directed By Engr-In-Charge. 61 Servicing Of Existing Screw / Reciprocating Type Air Compressor Of Any Make / Model, By Engaging Sufficient Man Power And Suitable T&P To Ensure Safety Of Plant As Well As Working Persons Including Disconnecting Of Air / Electric Connections, Dismantling Of Air Compressor By Unscrewing / Cutting Of Screws, Nuts & Bolts Etc, Dismantling Of Air Filter, Unserviceable Parts / Items, Air Receivers, Moisture Separator, Air Suction Silencer And Fixing The New Spare Part As Given Below, Replacing Complete Oil With New Oil Of Recommended Make & Grade, Adjusting / Balancing The Compressor Parts / Items Including All Machine Works I.E. Welding, Cutting, Drilling Etc As And When Required And Reassembling The Compressor, Making Electric Connection And Testing For Leakage, Required Air Pressure & Suction Temperature Etc, Complete All As Specified And Directed By Engr-In-Charge.The Cost Of Transportation ( To And Fro ) And Other Necessary Equipment Shall Be Arranged / Brought By Contractor To Complete The Job And No Extra Cost Shall Be Paid To The Contractor In This Effect. The Defective Spares Parts / Items Will Be Measured And Paid Separately Under Respective Items Only. The Replacement Cost ( Labour Charges ) For All Defective Spares Parts / Items Mentioned In Boq ( Sch – ‘A’ ) Here In Afteras Supply Only, Is Deemed To Be Included In Quoted Rates And No Extra Cost Shall Be Paid To The Contractor In This Effect At Any Stage. ( I ) The Air Compressor Will Be Handed Over To Contractor In As And Where Condition. Hence, The Bidder Is Advised To Visit The Site To Assess The Quantum Of Work To Be Carried Out In This Contract. No Claim On Condition Of Air Compressor Will Be Accepted At Later Stage And Bidder Is Deemed To Have Visited The Site To Ascertain The Condition Of Air Compressor. ( Iii ) The Cost Of Any Spare Part ( S ) , Other Than Specified Here-In-Above And Which Are Essential To Be Replaced For Smooth Working Of Compressor Is Deemed To Be Included In Quoted Rates And No Extra Cost Shall Be Paid To The Contractor On This Account. ( Iv ) The Cost Of All Kind Of Repair Includingminor Items I.E. Wire, Lugs, Nut, Bolts, Screws Etc, Is Deemed To Be Included In Quoted Rates And No Extra Cost Shall Be Paid To The Contractor On This Account. ( V ) The Entire Work Shall Be Carried Out By The Oem Or Auth Dealer Of The Oem Only. 62 Supply Only Crank Shaft 63 Supply Only Cylender Sleeve Lp +Hp 64 Supply Only Piston Lp+Hp 65 Supply Only Piston Ring Lp+Hp 66 Supply Only Fingar Valve Lp+Hp 67 Supply Only Air Filter Assy 68 Suuply Only Nrv Assy 3 / 4 69 Supply Only Bearing 70 Supply Only Gasket 71 Supply Only Oil Indictor Breather Valve 72 Supply Only Compressor Oil Of Suitable Grade / Make 73 Supply & Fixing In Replacement Of Digital Ammeter Of Size 96Mm X 96Mm, Three Phase, 5A, Class I With Inbuilt Selector Switchcomplete All As Specified And Directed By Engr-In-Charge. 74 M&L For Preventive And Periodical Repair / Overhauling Of Steam Boiler Of 850 / 650 Kg Capacity ( Make : Thermax Rxd ) By Engaging Sufficient Man Power And Suitable T&P To Ensure Safety Of Boiler Plant As Well As Working Persons Including Disconnecting Of Water / Steam / Electric Connections, Dismantling Of Boiler Plant By Unscrewing / Cutting Of Screws, Nuts & Bolts Etc, Taking Out Complete Coil Assembly And Other Major Parts From The Boiler Etc, Replacing All Defective Spares Parts ( Spare Parts Shall Be Measured And Paid Seperately AsSupply Only In Respective Items Catered Here-In After ) Cleaning / Servicing Of Coil Assemblyincl Electrical Control Panel Board, All Machine Works I.E. Welding, Cutting, Drilling Etcas And When Required And Reassembling All Dismantled Part / Items After Carrying Out Necessary Repair As Required, Other Material, Cleaning, Servicing, Oiling, Greasing Etc, Making All Steam / Water Connection And Electrical Connection, Leak Testing At Desired Pressure, With And Including Testing, Commissioning Of Complete Boiler Plant In Original Location For Smooth And Trouble Free Operation, To Entire Satisfaction Of Engineer-In-Charge, Complete All As Specified And Directed By Engr-In-Charge.Note : The Entire Work Incl Spare Parts / Items, As Mentioned In Srl Item No 75.00, Shall Be Got Executed Through Oem I.E. M / S Thermax Ltd Only. The Defective Spares Parts / Items Will Be Measured And Paid Separately Under Respective Items Only. The Replacement Cost ( Labour Charges ) For All Defective Spares Parts / Items Mentioned In Boq ( Sch – ‘A’ ) Here In Afteras Supply Only, Is Deemed To Be Included In Quoted Rates And No Extra Cost Shall Be Paid To The Contractor In This Effect At Any Stage. The Boiler Plants Will Be Handed Over To Contractor In As And When Condition And Cost Of All Kind Of Repair Incl Minor Items I.E. Wire, Lugs, Nut, Bolts, Screws Etc, Other Than Mentioned In Sch A, Is Deemed To Be Included In Quoted Rates And No Extra Cost Shall Be Paid To The Contractor In This Effect. Hence, The Bidder Is Advised To Visit The Site To Assess The Quantum Of Work To Be Carried Out In This Contract. The Cost Of Transportation ( To And Fro ) And Other Necessary Equipment Shall Be Arranged / Brought By Contractor To Complete The Job And No Extra Cost Shall Be Paid To The Contractor In This Effect. 75 Supply Only Limit Switch Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 76 Supply Only Coil Rxd 850 For 850 Kg / Hr Boiler Hsn / Sac 84029020 , Part No Prxcl10002model : Rxd / 850 Complete All As Specified And Directed By Engr-In-Charge. 77 Supply Only Sequence Controller Ma 810 Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 78 Supply Only Burner Rod Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 79 Supply Only Metallic Hose Pipe 3 / 8 X 40 Size Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 80 Supply Only Ss Diffuser Plate 132 Mm Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 81 Supply Only Insulyte 7 Low Density Insulating Castable Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 82 Supply Only Electronic Sequence Timer Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 83 Supply Only Thermocouple K Type Ss310 For Primary Chamber Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 84 Supply Only Safety Relief Value Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 85 Supply Only Resin T-40 Na Complete All As Specified And Directed By Engr-In-Charge. 86 S&F, In Replacement, Of Rtdpt-100 Temperature Sensor Output, Complete All As Specified And Directed By Engr-In-Charge. 87 S&F, In Replacement, Of Rtd Temperature Controller 0-1200ºc, K Type Input, Complete All As Specified And Directed By Engr-In-Charge. 88 Supply Onlyoil Filtersuitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 89 Supply Onlyignition Electrode Suitable For Steam Boiler Of 850 / 600 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 90 Supply Onlyphoto Ignition Electrode Suitable For Steam Boiler Of 850 / 600 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 91 Supply Onlyfuel Pump Aj6ac Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 92 Supply Only Valve Seat Assembly For Triplex Pump Suitable For Steam Boiler Of 850 Kg Capacity Complete All As Specified And Directed By Engr-In-Charge. 93 Supply Only Maxtreat 3220 Solution For Water Softning Plant Complete All As Specified And Directed By Engr-In-Charge. 94 Supply Only Maxclean 05 Descaling Chemical For Boilerplant Complete All As Specified And Directed By Engr-In-Charge. 95 Supply Only Maxtreat 3004 Solution For Water Softning Plant Complete All As Specified And Directed By Engr-In-Charge. 96 Supply Only Hardness Kit For Testing Of Water Complete All As Specified And Directed By Engr-In-Charge. 97 M&L For Dismantling Of Electric Driven Horizontal Induction Motor Of Upto 2.0 Hp Capacity Of Any Type And Make, By Engaging Sufficient Man Power And Suitable T&P To Ensure Safety Of Pump-Motor As Well As Working Persons Including Disconnecting Of Electric Connections, Dismantling Of Motor, Taking Out The Burnt Windings, Cleaning And Washing Of Slots And Rewinding The Same With Copper Winding Wire Of Existing Gauge And Quantity ( As Per Original Manufacturer Design ) Including Replacement Of All Damaged Parts I. E. Bearings, Bush, Thrust Plate, Thrust Bearing, Connector Plate, Insulating Materials Such As Insulating Sheets Insulating Paper ( Class F ) , Sealing Compounds Etc And Reassembling The Motor After Varnishing, Heating / Drying, Greasing Of Moving Parts Etc And Reinstallation Of The Motor In Original Location, Checking The Alignment, Making Proper Electric Connection, Testing For Smooth Operation, Complete All As Specified And Directed By Engr-In-Charge. Note : ( I ) The Cost Of Winding Wire And All Replaced Defective Parts Are Deemed To Be Included In Quoted Rates And No Extra Cost Shall Be Paid To The Contractor In This Effect. ( Ii ) Thecost Of Transportation ( To And Fro ) And Other Necessary Equipment Shall Be Arranged / Brought By Contractor To Complete The Job At Site Or At Repair Shop And No Extra Cost Shall Be Paid To The Contractor In This Effect. 98 All As Per Srl Item No 97 Here-In-Above But For 5.0 Hp Capacity, 3 Ph, 415 Volt, 50 Hz Ac. 99 All As Per Srl Item No 97 Here-In-Above But For 10.0 Hp Capacity, 3 Ph, 415 Volt, 50 Hz Ac. 100 All As Per Srl Item No 97 Here-In-Above But For 30.0 Hp Capacity, 3 Ph, 415 Volt, 50 Hz Ac. 101 Supply And Lay Ms Pipe Pipe In Replacement 20 Mm Bore Heavy Grade With All Fittings Laid In Floors Or Ffixed To Walls And Ceiling Etc Complete All As Specified And Directed By Engr-In-Charge. 102 All As Per Item No. 101 Here-In-Before But For Pipe Size Of 25 Mm Dia. 103 All As Per Item No.101- Here-In-Before But For Pipe Size Of 32 Mm Dia. 104 All As Per Item No.101 Here-In-Before But For Pipe Size Of 40 Mm Dia. 105 All As Per Item No. 101 Here-In-Before But For Pipe Size Of 50 Mm Dia. 106 All As Per Item No. 101 Here-In-Before But For Pipe Size Of 65 Mm Dia. 107 All As Per Item No. 101 Here-In-Before But For Pipe Size Of 80 Mm Dia. 108 All As Per Item No. 101 Here-In-Before But For Pipe Size Of 100 Mm Dia. 109 M & L For Under Deck Insulation Forms Pipe Of 20 Mm To 100 Mm Dia Size With Glass Wool Of Denisity 48 Kg / Cum Suitable For Factory Laminated With Aluminum Foil And Providing Additional Support To Insulation With Amd Including Chickenwire Mesh , With An Include Applying Bituminus Compound And Gi Clading Of 26 Guage Gi Sheet With Inc. Taking Down Of Old Insulation And Preparing Of Pipe Surface By Sctraching / Removing Rust , Dust And Old Paints Etc. With Wire Brush , Emery Paper , Grinder Etc And Making Surface Smooth Complete All As Specified And Directed By Engr-In-Charge. 110 S&F In Replacement Bronze Globe Steamstop Valve Of Size 50 Mm Dia As Per Isi 778 , Class-2 Gun Metal Body ( Is-318Ltb2 ) , Screwed In Bonnet, Out Side Screw And Yoke Type Rising Stem , Test Pressure 500Psig. Hydraullic , Working Pressure 250Psig At 450Degree Farenhite Hsn Code 84818030, Complete All As Specified And Directed By Engr-In-Charge. 111 All As Per Srl Item No 110 Here-In-Above But 80 Mm Dia Size. 112 All As Per Srl Item No 110 Here-In-Above But 25 Mm Dia Size. 113 S&F, In Replacement, 6 Dia Caster Wheel, Swivel Type, Heavy Duty, With Supporting Base Plate Bracket Complete With Nut And Bolts Etc Of Existing Shape And Size Suitable For Washroom Trolley, Complete All As Specified And Directed By Engr-In-Charge. 114 S&F In Replacement, 6 Dia Caster Wheel, Fixed Type, Heavy Duty, With Supporting Base Plate Bracket Complete With Nut And Bolts Etc Of Existing Shape And Size Suitable For Washroom Trolley, Complete All As Specified And Directed By Engr-In-Charge. 115 Supply Only Pvc Container Trolley As Per Existing Size / Sample Suitable For Carry Patiant Cloths Complete All As Specified And Directed By Engr-In-Charge. 116 Supply Only Crystal Type Salt Of Sodium Chloride 25 Kg Bag For Water Softening Plant @ 3 Kg / Day Complete All As Specified And Directed By Engr-In-Charge. 117 Supply & Fixing In Replacement, Of Mccb 40 Amp, 4 Pole, 18 Ka, C Curve, Complete All As Specified And Directed By Engr-In-Charge. 118 Supply & Fixing In Replacement, Of Mccb 63 Amp, 4 Pole, 18 Ka, C Curve, Complete All As Specified And Directed By Engr-In-Charge. 119 Supply & Fixing In Replacement, Of Mccb 125 Amp, 3 Pole, 36 Ka, Ics = 100% Icu, With Adjustable Thermal Magnetic Setting Alongwith Spreader Terminals And Phase Barriers, Complete All As Specified And Directed By Engr-In-Charge. 120 All As Per Srl Item No. 119 Here-In-Before But 36 Ka 250 Amp Capacity. 121 All As Per Srl Item No. 119 Here-In-Before But 36 Ka 160 Amp Capacity. 122 Supply Only, In Replacement Of Brake Timer 0-60 Sec Time Delay Suitable For 25 Kg Hydro Extractor Complete All As Specified And Directed By Engr-In-Charge. 123 Supply Only, In Replacement Of, Diode 10Hi Cn 25D Suitable For 25 Kg Hydro Extractor Complete All As Specified And Directed By Engr-In-Charge. 124 Supply Only, In Replacement Of, Over Load Relay Suitable For Hydro Extractor Of 25 Kg, 5 Hp Motor Capacity Complete All As Specified And Directed By Engr-In-Charge. 125 Supply Only, In Replacement Of Timer 0-15 Sec Time Delay Suitable For 25 Kg Hydro Extractor Complete All As Specified And Directed By Engr-In-Charge. 126 Supply Only, In Replacement Of 3 Ph, 415 Volt , Contactor, Mnx-18 Amps With Neccessary No & Nc Aux Contact Complete All As Specified And Directed By Engr-In-Charge. 127 Supply Only, In Replacement Of 3 Ph, 415 Volt , Contactor, Mnx-25 Amps With Neccessary No & Nc Aux Contactcomplete All As Specified And Directed By Engr-In-Charge. 128 Supply & Fixing In Replacement Of Power Contactor Of 32 Amp Ac3 Rating, 03 Pole, Mnx32 With No+Nc Aux Contacts, 415Vwith And Including Taking Down Of Unserviceable Contactor And Making All Electric Connection, Complete All As Specified And Directed By Engr-In-Charge. 129 Supply & Fixing In Replacement Of Power Contactor Of 40 Amp Ac3 Rating, 03 Pole, Mnx40 With No+Nc Aux Contacts, 415Vwith And Including Taking Down Of Unserviceable Contactor And Making All Electric Connection, Complete All As Specified And Directed By Engr-In-Charge. 130 Supply & Fixingin Replacement Of Power Contactor Of 25 Amp Ac3 Rating, 03 Pole, 415 V, Ml 1.52No+2Nc Contactswith And Including Taking Down Of Unserviceable Contactor And Making All Electric Connection, Complete All As Specified And Directed By Engr-In-Charge. 131 Supply & Fixingin Replacement Of Power Contactor Of 25 Amp Ac3 Rating, 03 Pole, 415 V, Ml31 2No+2Nc Aux Contactswith And Including Taking Down Of Unserviceable Contactor And Making All Electric Connection, Complete All As Specified And Directed By Engr-In-Charge. 132 Supply & Fixing In Replacement Of Over Load Relay Mn2 Range 20-33 Amps, With Built In Single Phase Preventer, Direct / Separate Mounting On Contactors, As Required, With And Incl Taking Down Of Unserviceable Relay And Making All Electric Connection, Complete All As Specified And Directed By Engr-In-Charge. 133 All As Per Srl Item No 132 Here-In-Above But 14-23 Amps Capacity. 134 All As Per Srl Item No 132 Here-In-Above But 4.5-7.5 Amps Capacity. 135 Supply And Fixing Of Multi Port Valve For Water Softening Plant 50 Mm Pressure 5 Kg / Cm2 Complete All As Specified And Directed By Engr-In-Charge. 136 S&F, In Replacement Of Three Phase Mk1 Dol Starter, In Sheet Metal Enclosure With 4P, Ac3 Duty Contactor, 4P Over Load Relay And Single Phase Protection Suitable For7.5 Hp, 3 Ph, 415 Volt Ac, 50 Hz Electric Motorincl Making All Electric Connection, Complete All As Specified And Directed By Engr-In-Charge. 137 S&F, In Replacement Of Three Phase Fully Automatic Star-Delta Starter Mn 16 Fasdstarter, In Sheet Metal Enclosure Type With 4P, Ac3 Duty Contactor, 4P Over Load Relay And Single Phase Protection Suitable For 15 Hp, 3 Ph, 415 Volt Ac, 50 Hz Electric Motor With Relayrange 14-23Incl Making All Electric Connection, Complete All As Specified And Directed By Engr-In-Charge. 138 S&F, In Replacement Of Three Phase Fully Automatic Star-Delta Starter Mn 32 Fasd Starter, In Sheet Metal Enclosure Typewith 4P, Ac3 Duty Contactor, 4P Over Load Relay And Single Phase Protection Suitable For 25 Hp, 3 Ph, 415 Volt Ac, 50 Hz Electric Motor With Relayrange 14-23Incl Making All Electric Connection, Complete All As Specified And Directed By Engr-In-Charge. 139 S&F, In Replacement Of Off -Load Change Over Switch-Ac 21 ( Side Handle ) , Having Powder Coated Sheet Metal Enclosure, 400Amp, 03 Phase, 415 Volt, Complete All As Specified And Directed By Engr-In-Charge. 140 M&Linreplacement Of Rubber Packing For Lint Screen Suitable For Washer Extractor Of Capacity 120 / 100 Kgcomplete All As Specified And Directed By Engr-In-Charge. 141 M&L Forapplying One Coat Synthetic Enamelledpaint As Desired Colour Over A Coat Of Red Oxideprimer On Steel / Iron Surfaces Of Pipes After Preparing Surface With Help Of Emery Paper Etc Removingrust, Dust And Old Paintsand Making Surfaces Smooth For Achieving Better Grip Between Surface And Primer Complete All As Specified And Directed By Engr-In-Charge. 142 Dismantling Of Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) And Removing Rubbish Off Premises Min 500M Away From Bldg Complex, Complete All As Specified And Directed By Engr-In-Charge. 143 Demolition Of Cement Concrete ( Unreinforced ) As In Any Positionn.Exc. 15 Cm Below Or Above Ground Level And Removing Rubbish Off Premises Min 500M Away From Bldg Complex, Complete All As Specified And Directed By Engr-In-Charge. 144 Material And Labour For Machine Cut Kota Stone Flooring 20-25 Mm Thick Of Approved Size Over Cement Screed Base, Laid And Jointed With Grey Cemented Slurry Mixed With Pigment To Match The Shade Of Slab Including Rubbing And Polishing ( Mirror ) , Complete All As Specified And Directed By Engr-In-Charge. 145 Material And Labour For 20 Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:6 For Laying Kota Stone Floor Finishes, Complete All As Specified And Directed By Engr-In-Charge. 146 M&L For Preparation Of Old Decorated Wall Surfaces Including Washing Rubbing Down And Stopping Of Distempered Surfaces And Applying A Coat Of Distemper Oil Emulsion On Wall Surfaces, Complete All As Specified And Directed By Engr-In-Charge. 147 S&F Of Thermal Insulation On New / Existing Ducts And Plenum Chamber, Comprise Of Preparation Of Surface And Fixing Of New Cross Linked Closed Cell Polythene, Plane, Fire Retardant Insulation Of 9 Mm Thick Nitrile Insulation With Aluminium Foil Of The Ducthaving A Tow Stable K Value Of 0.027-0.029 Kcal / Hr / M At 0-23°C With Minimum Density Of 33 Kg / Cum, Fire Retardant Self Extinguishing On Dripping, Good Ozone Resistance, Including Fixing The Insulation To The Duct Surface With Help Of Adhesive Paste And Closing The Gap With Self Adhesive Tape Of 3Mm Thick, Complete All As Specified And Directed By Engr-In-Charge.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Jan-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-01-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 86720.0 /-
Tender Value
INR 43.36 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail