Supply, Erection And Commissioning Of Various Electromechanical Equipments Like Vt Pumps, Electric Motors, Ltdb Panel And Other Allied Material At Pump House No. 4 Siwani Canal Supply, Erection And Commissioning Of Various Electromechanical Equipm, Bhiwani-Haryana

Irrigation Department has published Supply, Erection And Commissioning Of Various Electromechanical Equipments Like Vt Pumps, Electric Motors, Ltdb Panel And Other Allied Material At Pump House No. 4 Siwani Canal Supply, Erection And Commissioning Of Various Electromechanical Equipm. Submission Date for this Tender is 11-01-2022. Electromechanical Machinery Tenders in Bhiwani Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

30335683
Corrigendum : Supply, Erection And Commissioning Of Various Electromechanical Equipments Like Vt Pumps, Electric Motors, Ltdb Panel And Other Allied Material At Pump House No. 4 Siwani Canal Supply, Erection And Commissioning Of Various Electromechanical Equipm
Open Tender
Indian
Haryana
Bhiwani
11-01-2022

Tender Details

Supply, Erection And Commissioning Of Various Electromechanical Equipments Like Vt Pumps, Electric Motors, Ltdb Panel And Other Allied Material At Pump House No. 4 Siwani Canal Supply, Erection And Commissioning Of Various Electromechanical Equipments Like Vt Pumps, Electric Motors, Ltdb Panel And Other Allied Material At Pump House No. 4 Siwani Canal , Supply, Erection And Commissioning Of 60 Cs. V.T. Axial Flow Pumps Of 740 Rpm, Having Static Lift Of 27.5 Feet, Including Delivery Pipe As Per Actual Site Requirement And Ms Delivery Bends Of Minimum 8 Mm Thickness With Bituminous Based Paint Inside & Outside Including Flange Welding, S.S Nut-Bolts, Siphon Breaker Valve, Complete In All Respect, As Per Site And As Per Approved Technical Specifications. Ns Item ( For Ph 4 Siwani Canal ) . , Supply, Erection And Commissioning Of 30 Cs. V.T. Axial Flow Pumps Of 980 Rpm, Having Static Lift Of 27.5 Feet, Including Delivery Pipe As Per Actual Site Requirement And Ms Delivery Bends Of Minimum 8 Mm Thickness With Epoxy Coating Inside & Outside Including Flange Welding, S.S Nut-Bolts, Siphon Breaker Valve, Complete In All Respect, As Per Site And As Per Approved Technical Specifications. Ns Item ( For Ph 4 Siwani Canal ) . , Supply, Erection And Commissioning Of Solid Shaft Motor Of Capacity 325Hp Of 8 Pole, 740 Rpm, 3 Phase 415 Volt With Efficiency Class Ie2 ( As Per Is 12615 With Latest Amendments ) Suitable For 60 Cs. Vt Axial Flow Pumps Type Vertical Flange Mounted & As Perapproved Technical Specification With Earthing Of Motor. Ns Item ( For Ph 4 Siwani Canal ) . , Supply, Erection And Commissioning Of Solid Shaft Motor Of Capacity 150Hp Of 6 Pole, 980 Rpm, 3 Phase 415 Volt With Efficiency Class Ie2 ( As Per Is 12615 With Latest Amendments ) Suitable For 30 Cs. Vt Axial Flow Pumps Type Vertical Flange Mounted & As Perapproved Technical Specification. Ns Item ( For Ph 4 Siwani Canal ) . , Supply, Erection And Commissioning Of Ltdb Of 1250 Amp. Capacity With All Accessories As One Incomer Acb 4 Pole 1250 Amp. With 3 No. Outgoing2 No. Of Having Mccb Of 800 Amp.& 1 No. 400 Amp. Alongwith An-Addl. Mccb Of 100 Amp. For Lighting Loads, Indicators, Relay, Meters, Push Buttons, Bus Bars And With 3 No. Fully Automatic Ats Starters ( Completed In All Respect Like Relays, Indicators Timer Etc. ) . Of 2 No. 325 Hp & 1 No. 150 Hp Motors With 2 No. Mccb Of 630 Amp.& 1 No. 400 Amp.With Contactor Rating As 700, 550 , 400 Amp. For 325Hp And 400, 300, 200 For 150Hp With First Filling Of Oil ( If Oil Cooled Ats Used ) With Designed Capacitor Bank Of 350Kvar Capacity With 8 Step Apfcr, Each Stage Should Have Protection Through Separate Mccb. One No. Incomer Mccb Of 630 Amps To Be Provided For Capacitor Bank, Digital Display Instruments & Other Allied Accessories For Automatic As Well As Manual Operation Of Capacitor Bank Suitable For 2 Nos. 325 Hp & 1 No. 150 Hp Motors As Per Approved Design Of Ltdb With A Stand Of Ms Channel ( 1 Ft. Up From Floor ) & As Per Approved Technical Specification With Earthing. ( For Ph 4 Siwani Canal ) . , Supply, Erection And Commissioning Of Ltdb Of 1250 Amp. Capacity With All Accessories As One Incomer Acb 4 Pole 1250 Amp. With 3 No. Outgoing2 No. Of Having Mccb Of 800 Amp.& 1 No. 400 Amp. Alongwith An-Addl. Mccb Of 100 Amp. For Lighting Loads, Indicators, Relay, Meters, Push Buttons, Bus Bars And With 3 No. Fully Automatic Ats Starters ( Completed In All Respect Like Relays, Indicators Timer Etc. ) . Of 2 No. 325 Hp & 1 No. 150 Hp Motors With 2 No. Mccb Of 630 Amp.& 1 No. 400 Amp.With Contactor Rating As 700, 550 , 400 Amp. For 325Hp And 400, 300, 200 For 150Hp With First Filling Of Oil ( If Oil Cooled Ats Used ) With Designed Capacitor Bank Of 350Kvar Capacity With 8 Step Apfcr, Each Stage Should Have Protection Through Separate Mccb. One No. Incomer Mccb Of 630 Amps To Be Provided For Capacitor Bank, Digital Display Instruments & Other Allied Accessories For Automatic As Well As Manual Operation Of Capacitor Bank Suitable For 2 Nos. 325 Hp & 1 No. 150 Hp Motors As Per Approved Design Of Ltdb With A Stand Of Ms Channel ( 1 Ft. Up From Floor ) & As Per Approved Technical Specification. Ns Item ( For Ph 4 Siwani Canal ) .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Dec-2021 Technical Specification Technical Bid 03-01-2022
2 31-Dec-2021 Date Extended Date 11-01-2022

Key Value

Document Fees
INR 15000 /-
EMD
INR 533020.0 /-
Tender Value
INR 2.66 Crore /-

BOQ Items

Name of Work: Supply, Erection and Commissioning of Various Electromechanical Equipments like VT Pumps, Electric Motors, LTDB Panel and Other allied material at Pump House No. 4 Siwani Canal
Sl. No. Item Description
1Supply, erection and commissioning of 60 Cs. V.T. Axial flow pumps of 740 RPM, having static lift of 27.5 feet, including delivery pipe as per actual site requirement and MS delivery bends of minimum 8 mm thickness with Bituminous Based Paint inside & outside including flange welding, S.S nut-bolts, Siphon Breaker Valve, complete in all respect, as per site and as per approved technical specifications. NS Item (for PH 4 Siwani Canal).
2Supply, erection and commissioning of 30 Cs. V.T. Axial flow pumps of 980 RPM, having static lift of 27.5 feet, including delivery pipe as per actual site requirement and MS delivery bends of minimum 8 mm thickness with epoxy coating inside & outside including flange welding, S.S nut-bolts, Siphon Breaker Valve, complete in all respect, as per site and as per approved technical specifications. NS Item (for PH 4 Siwani Canal).
3Supply, erection and commissioning of solid shaft motor of capacity 325HP of 8 pole, 740 RPM, 3 phase 415 Volt with efficiency class IE2 (as per IS 12615 with latest amendments)suitable for 60 Cs. VT Axial flow pumps type vertical flange mounted & as perapproved technical specification with earthing of motor. NS Item (for PH 4 Siwani Canal).
4Supply, erection and commissioning of solid shaft motor of capacity 150HP of 6 pole, 980 RPM, 3 phase 415 Volt with efficiency class IE2 (as per IS 12615 with latest amendments)suitable for 30 Cs. VT Axial flow pumps type vertical flange mounted & as perapproved technical specification. NS Item (for PH 4 Siwani Canal).
5Supply, erection and commissioning of LTDB of 1250 Amp. Capacity with all accessories as one incomer ACB 4 pole 1250 Amp. with 3 No. outgoing2 No. of having MCCB of 800 Amp.& 1 No. 400 Amp. alongwith an-addl. MCCB of 100 Amp. for lighting loads, Indicators, Relay, Meters, Push buttons, bus bars and with 3 No. Fully Automatic ATS Starters( Completed in all respect like relays, indicators timer etc.). of 2 No. 325 HP & 1 No. 150 HP Motors with 2 No. MCCB of 630 Amp.& 1 No. 400 Amp.with contactor rating as 700,550 ,400 Amp. For 325HP and 400,300,200 for 150HP with first filling of oil (if oil cooled ATS used) with designed capacitor bank of 350KVAR capacity with 8 step APFCR, Each Stage should have protection through separate MCCB. One No. Incomer MCCB of 630 Amps to be provided for Capacitor Bank,digital display instruments & other allied accessories for automatic as well as manual operation of capacitor bank suitable for 2 Nos. 325 HP & 1 No. 150 HP motors as per approved design of LTDB with a stand of MS Channel ( 1 ft. Up from floor) & as per approved technical specification with earthing.(for PH 4 Siwani Canal).
6Supply, erection and commissioning of LTDB of 1250 Amp. Capacity with all accessories as one incomer ACB 4 pole 1250 Amp. with 3 No. outgoing2 No. of having MCCB of 800 Amp.& 1 No. 400 Amp. alongwith an-addl. MCCB of 100 Amp. for lighting loads, Indicators, Relay, Meters, Push buttons, bus bars and with 3 No. Fully Automatic ATS Starters( Completed in all respect like relays, indicators timer etc.). of 2 No. 325 HP & 1 No. 150 HP Motors with 2 No. MCCB of 630 Amp.& 1 No. 400 Amp.with contactor rating as 700,550 ,400 Amp. For 325HP and 400,300,200 for 150HP with first filling of oil (if oil cooled ATS used) with designed capacitor bank of 350KVAR capacity with 8 step APFCR, Each Stage should have protection through separate MCCB. One No. Incomer MCCB of 630 Amps to be provided for Capacitor Bank,digital display instruments & other allied accessories for automatic as well as manual operation of capacitor bank suitable for 2 Nos. 325 HP & 1 No. 150 HP motors as per approved design of LTDB with a stand of MS Channel ( 1 ft. Up from floor) & as per approved technical specification. NS Item (for PH 4 Siwani Canal).