Irrigation And Public Health Department has published Aug. Of Wss Tipper Pokhar Karad, Bagi, Bala Zehra And Shilli Ropa In Anni Block Distt. Kullu ( H.P ) Rcc Anchor Block , Providing Laying Of Mserw Pipe 100Mm Dia With Butt Welding Flanged In Both Stages And Laying Jointing Of Gi Pipe 100Mm In Trenches. Submission Date for this Tender is 23-12-2021. Pipe Laying Tenders in Anni Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Excavation in foundation and trenches etc.(for pipes & pits) in earth work in all kinds of soil such as pick work, jumper work, blasting soft or hard rock or by chiselling soft or hard rock where blasting is prohibited in all leads and lifts including trimming / dressing of sides and bed, stacking the excavated soil clear from the edge of excavation and returning the excavated soil after completion of work in 15cm layers when required into plinth, sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated soil complete in all respect as per directionand to the entire satisfaction of the Engineer-in-Charge. |
2 | Providing and laying cement concrete 1:3:6(1 cement:3 sand:6 graded stone agg. 40mm nominal size) and curing complete excluding cosot of form work and reinforcement of RCC work in foundation and plinth with in all leads and lifts as per directionand to the entire satisfaction of the Engineer-in-charge. |
3 | Providing and layingcement conc. 1:2:4(1 cement:2 sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cosot of form work and reinforcement of RCC work in all leads and lifts as per directionand to the entire satisfaction of the Engineer-in-charge. |
4 | Foundation footing and bases of columns & like mass concrete. |
5 | Providing form work with steel plate 3.15 m.m thick welded with angle iron 30x 30 x5 m.m so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling upto all heights and removal of the same for in-situ reinforced conc.and plain conc.work in :- |
6 | Vertical surfaces such as walls (any thickness)portions and the like including attached pilaster buttresses plinth and string course and the like |
7 | Providing tor steel reinforcement for RCC work including bending, binding and placing in position i /c binding wire complete up to floor two level complete in all respect as per direction & to the entire satisfaction of Engineer-in- Charge upto all lead & lifts. |
8 | Providing Laying in trenches IS marked MSERW pipe L-290of following diameters conforming to BIS 3183-2007 of following grade and having wall thickness as specified below with plain end capable of with standing required test presure in random length of 4 to 7 mtr, including specials, short pieces bends, reducers, tees etc. made from parent tube with providing and weldingof MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 ( with latest up to date amendments) duly welded in two layers ( two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standared. The laying of pipe will include all operation such as cutting welding jointing providing and fixing of MS flanges fabrication of bends tees etc. including lowering and laying in excavated trenches to ensure required level including flushing cleaning and hydralic testing complete in all respects to the satisfaction of the Engineer inCharge. The fabricated bends shall have three or four cuts having its radius not less than five time the dia of pipe. The pipe shall be factory galvanized ( zinc coating both inside and outside) as per relevant IS standareds and the damaged portion of the pipe and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of antocorrosive bituminous paint over a priming coat as per AWWA Specification C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrriage of matrial flushing cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts.(5% of Lenght of Rising Main has been taken for Flanged) |
9 | 1St Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 0 3003001005.634 Flanged Length @5% 15 |
10 | 1St Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 300 6003001004.834 Flanged Length @5% 15 |
11 | 1St Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 6009003001004.828 Flanged Length @5% 15 |
12 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 0 3003001005.634 L.For Flange 15 |
13 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 300 6003001004.834 L.For Flange 15 |
14 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 600 9003001004.828 L.For Flange 15 |
15 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 900 12003001004.5 28 L.For Flange 15 |
16 | Providing, laying,jointing ( by way of circumfrential butt welded jointsby electrical arc welding ) and testing of MSERW pipe L-290 of following dia meters confirming to BIS 3183-2007, steel grade -A(latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). |
17 | 1St Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness 0300 3001005.6 Length of Butt Welding @95% 285 |
18 | 1St Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness 300 900 6001004.8 Length of Butt Welding @95% 570 |
19 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness 0300 3001005.6 Length of Butt Welding @95% 285 |
20 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness 300 900 6001004.8 Length of Butt Welding @95% 570 |
21 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness 900 1200 300100 4.5 Length of Butt Welding @95% 285 |
22 | Laying,jointing testing in trenches to be levelled to grades,GI flanged pipes of following diameter confirming to IS:1239-1990(Part-II)having minimum wall thickness as per IS code and classof pipes specified below, i/c cost of flanges conforming to table as specified below of BIS 6392-1971 welded at both ends according to relevant BIS standards and detailed specifications and provided with nut & bolts of required size ,3mm thick compressed asbestos fiber gasket/ synthetic rubber gasket, confirming to relevant BIS code including all kind of flanged short pieces,bends,tees & other specials etc made from parent tubes & welded with flanges of tables as applicable for the perticular reach as per site condition including flushing cleaning & hydraulic testing as per directions of Engineer in charge. |
23 | 1St Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 900 1200 300100 4.5 28 Length of Butt Welding @5% 15 |
24 | 1St Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 1200 1550 350100 4.5 17 Length of Butt Welding @5% 17.5 |
25 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Flange table 1200 17005001004.5 17 Length of Butt Welding @95% 25 |
26 | Layingand Jointing (by way of circumfrential butt welded joints by electrical arc welding) andtesting ofG.I pipes of following dia meters confirming to BIS 3183-2007 (latest with upto date amendment) having wall thickness as per code with bevelled/ plain ends in arandom length of 4 to 7 meters, including manufacturing reducers tapers all shorts pieces bend etc as per site requirement made from parent tubes tees etc. The laying of pipe wil including lowring and laying in excavated trenches to ensuere required level including flushing cleaning and hydrolic testing complete in all respects to the satisfaction of the Engineeer in Charge. The fabricated bends shall have three or four cuts having its rudius not less then five times the dia of pipe. The damaged portion of the pipes and special made for parenttube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminnous paint over a primingcoat as per AWWA specification C-203-1978. The weldingelectroded shall be as per IS 814 of Advani,Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material Flushing Cleaning & Hydrolic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts.( 95% Lenght of Rising main has been taken for Butt Welding) |
27 | 1St Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Class 9001550650 100 4.5 (MC) Length of Butt Welding @95% 617.5 |
28 | 2nd Stage RDFrom ToLength in mtrs Pipe (MM)wall Thickness Class 1200 1700500100 4.5 (MC) Length of Butt Welding @95% 475 |
29 | 1St Stage Prov. fixing commissioning & testing of horizontal spindle, horizontal/redial spilt casing/end suction (back full out arrangement) single/double/multistage centrifugal pumpin series/parallel of recommended make such as Mather and Platt/KSB/Beacon weir/Jyoti/ WASP/ Kirlosker/ ASPEE (Asea Brown Boven LTD) as per BIS 1520-1980 with upto dateamendements, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze, impeller, priming funnels, casing ring and shaft sleeves of bornze shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common CI/Cast steel/base plate (base plate to be from the manufacturer of the pumping unit only) to slipring/squirrel cage screen protected drip proof induction motor /motors of standred make such as Kirloskar/BEHL/Crompton/NGEF /GEC/Siemens/Jyoti and suitable for opration on 415(+/-) 5% volts 50 cycles/second. 3 phase AC electric supply. The power of electric motor/motors should be at least +10% in excess of the maximum power required by the pump/pumps in the operationrange of(+) 10% and (-) 15% of the duty point head. The motor/ motors as per IS: 325-1978 with uptodate ammendements readwith IS:900-1972. It should include cost of bearing, nuts,bolts and painting etc. and should meet the following requirements. |
30 | I) Discharge(Q) =6.21 LPS for each Pump |
31 | ii) Total dynamic head = 567.26 meters |
32 | a) LWL in sump well (h) = 1627.00 meters |
33 | b) Shaft level= 1626.00 meters |
34 | c) Level at discharge point = 2170.00 meters |
35 | d) suction lif = + ve (-)1.00Mt |
36 | e)Discharge head= 567.26 meters |
37 | f) Static head = 544.00 meters |
38 | iii) Rising main |
39 | a) Length1550 meters |
40 | b) dia 100 mm |
41 | iv) Pumping hours8 hours |
42 | v) Altitude of installation above MSL 1626 meters |
43 | vi) Characteristices of water with turbidity upto 50 PPM |
44 | a) Temperature200C |
45 | b) Ambient temp44 0C |
46 | c) Turbidity50 JTU |
47 | d) Alkalanilty mg/1 Ca |
48 | e) Size of the solidsmm |
49 | f) others |
50 | Providing ICTP main switch with HRC of Kilburn/L&T /Siemens/Standarrd/Havells make and having capacity 30% extraof operational rating as per IS:4069-1978 with up to date amendments,immediately afterthe power meter of HPSEBL. |
51 | Prov. & fixing M.S. sheet,steel fabricated floor mounted closed (almirach type switch board including angle iron post of suitable height and size ISA 40x40x6, duly painted with steel sheet of16 guage comprising and capable of mounting the following accessories with all internal connections.All accessories should be suitable for the proposed pumping machinery at item NO.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authoroties. |
52 | OCB/MCCB of MEI/Havels/standard make and suitable capacity of offered motor on incoming feeder with or without intial oil filling as the case may be with linked under voltage released as per relevent IS code with up to date ammendments |
53 | Earth leakage circuit breaker ELR of recommended make(Kilburn/L&T/MEI/GEC as per IS:2516-1977 with uptodate ammendements and of suitable of range which should have control box, operating,handle and trip/reset bush button on/off indicatorsre-indicating off spring condition of the circuit breaker for over current protection.The circuit should be equipped with magnet thermal release with metallic tape CTS, It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side and.suitable for 60 HP motor. |
54 | The voltage meter relay 3 phase with all protection and usual indicators and electric siran against single phasing, Low voltage high voltage reverse phasing over loading and phase voltage difference as per IS:3842(latest edition) |
55 | Digital 100 mm diameter circular dial A.C. supply volt meter of recommended make AE/IMP/Havells of suitable range with slector switches as per IS:4064-1978 with uptodate ammendements. |
56 | Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with up to date ammendments |
57 | Digital frquency meter of standard make AE/L&T/IMP/Havells as per relevant IS code with up to date ammendments |
58 | Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for netural phase as per IS:8084-1976 and IS:11353-1985 read with BIS-5578-1985 with uptodate ammendements |
59 | Providing and fixing of change over switch requiredcapacity of Kilburn/Larsen & turbo/ Standard/ Siement make andwith upto date ammendments immediatly after the power meter of HPSEB ICTP Main switch.i.make,ii.Type,iii. Range. |
60 | Three phase indicator lamps complete with toggie switches for individual motors as per IS:3452(P-I&II) with upto date ammendements. |
61 | Digital 100mm dia circular dia A.C. supply ammeter of A/E/IMP/Havells make of suitable range with selector switches andCTS operated as per IS:1248(P-II) 1983 with upto date amendements. |
62 | Capacitor of Mecheil/BHEL/GEC/L&T/ make as per IS 2834-1986 with upto date ammendements, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according toH.P. offered including cables as per relevent ISI code (of Siemens/Clocter/IEC make) from bus bar chamber to capacitor and also including ICPT switches of appropriate upto date ammendements. |
63 | Providing fixing suitable oil imersed Auto transformer/starter rotor starter of MEI/Kilburn/Jyoti /L&T/ Siemens/make as per IS:8544-1979 with upto date ammendements for squirrel cage/slip ring motor mountedon panel board with magentic type over load release and dashpot,time lag,under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS:1248(P-V)-1983 with upto date ammendements. |
64 | n) Providing Digital hour run meter of recommended make and suitables capacity as per IS :722 ( latest edition) |
65 | Providing & fixing 100mm dia circular dial pressure guage of fiebig /bourden PREGA/Precision make complete with all accessories such as stock cock, copper tubing etc. as per IS:3624-1987 with upto date ammendements. |
66 | Errection of all equipments i /c cost of tees bends lapers and any other fittings required as per site conditions and as per directions of Engineer-in-charge. |
67 | Providing double flanged CI sluice valve PN-1.00ofLeader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar/KSB make and equal to dia ofsuction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments. |
68 | Providing& fixing double flangedcaststeel reflux valve of leader/BHELKirloskar/Kilburn/Fouress make and ofequal to dia of the pump delivery and capable of with standing the normal sheet pressure as per ISAPI -6D with upto dateammendements.class ASA-600 |
69 | Providing double flanged CS sluice valveofLeader/BHEL/Kirlosker /GLEd/ Kilburn Fourses / Kartar make and equal to dia ofpump delivery and capable of withstanding the normal seat pressure as per API -6D with upto date ammendments. Class ASA-600 STP 104 kg/cm2 |
70 | Providing& fixing double flangedcaststeel reflux valve of leader/BHEL/ Kirloskar /Kilburn/Fouress/KSB make and ofequal to dia ofrising main and capable of with standing the normal sheet pressure as per BIS1414/ API 600 with upto dateammendements.class ASA-600 STP 104 kg/cm2 |
71 | Providing and fixing double flanged G.I./MSERW piping work(layout to be approved by the Engineer-in-charge work for suction and delivery pipe suitable of pump(S) offered and common header as per the Rising main respectively complete with all specials such as bends Rising main respectively complete with all specials such as bends tees, reducers, increasers,with companion flanges matching with the IS specification of the accessories including rubber/ asbostos gasket of 3mm thickness as per IS 2712-1979 and required number of nuts and bolts as per IS 1364-1983.The pipe shall be as per relevent IS code and to with stand 1.5 times total head stipulated under item No.1. The size of the various component to be as under:- |
72 | Suction pipe 150mm diaGI Pipe = 10 Rmt. |
73 | Delivery pipeMSERWPipe = 5 Rmt. |
74 | Common header MSERWPipe = 10 Rmt. |
75 | Providing and laying copper PVC insulatedarmured power cable (one cable carrying all the three phases) of 3 core suitable size and capacity to motors and all other electrical equipments as per IS: 1554(P-I) 1988 or latest with upto date ammendements of siemens/Gloster/IEC/ICC/EICO/ National/ GRANDLY make including all other accessories such as thimble, flaxible pipes, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
76 | Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode completewith material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
77 | 2nd Stage Prov. fixing commissioning & testing of horizontal spindle, horizontal/redial spilt casing/end suction (back full out arrangement) single/double/multistage centrifugal pumpin series/parallel of recommended make such as Mather and Platt/KSB/Beacon weir/Jyoti/ WASP/ Kirlosker/ ASPEE (Asea Brown Boven LTD) as per BIS 1520-1980 with upto dateamendements, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze, impeller, priming funnels, casing ring and shaft sleeves of bornze shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common CI/Cast steel/base plate (base plate to be from the manufacturer of the pumping unit only) to slipring/squirrel cage screen protected drip proof induction motor /motors of standred make such as Kirloskar/BEHL/Crompton/NGEF /GEC/Siemens/Jyoti and suitable for opration on 415(+/-) 5% volts 50 cycles/second. 3 phase AC electric supply. The power of electric motor/motors should be at least +10% in excess of the maximum power required by the pump/pumps in the operationrange of(+) 10% and (-) 15% of the duty point head. The motor/ motors as per IS: 325-1978 with uptodate ammendements readwith IS:900-1972. It should include cost of bearing, nuts,bolts and painting etc. and should meet the following requirements. |
78 | I) Discharge(Q) = 5.75 LPS for each Pump |
79 | ii) Total dynamic head = 506.38 meters |
80 | a) LWL in sump well (h) = 2167.00 meters |
81 | b) Shaft level= 2166.00 meters |
82 | c) Level at discharge point = 2650.00 meters |
83 | d) suction lif = + ve (-)1.00Mt |
84 | e)Discharge head= 506.38meters |
85 | f) Static head = 484.00 meters |
86 | iii) Rising main |
87 | a) Length1700 meters |
88 | b) dia 100 mm |
89 | iv) Pumping hours8 hours |
90 | v) Altitude of installation above MSL2166 meters |
91 | vi) Characteristices of water with turbidity upto 50 PPM |
92 | a) Temperature200C |
93 | b) Ambient temp44 0C |
94 | c) Turbidity50JTU |
95 | d) Alkalanilty mg/1 Ca |
96 | e) Size of the solidsmm |
97 | f) others |
98 | Providing ICTP main switch with HRC of Kilburn/L&T /Siemens/Standarrd/Havells make and having capacity 30% extraof operational rating as per IS:4069-1978 with up to date amendments,immediately afterthe power meter of HPSEBL. |
99 | Prov. & fixing M.S. sheet,steel fabricated floor mounted closed (almirach type switch board including angle iron post of suitable height and size ISA 40x40x6, duly painted with steel sheet of16 guage comprising and capable of mounting the following accessories with all internal connections.All accessories should be suitable for the proposed pumping machinery at item NO.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authoroties. |
100 | OCB/MCCB of MEI/Havels/standard make and suitable capacity of offered motor on incoming feeder with or without intial oil filling as the case may be with linked under voltage released as per relevent IS code with up to date ammendments |
101 | Earth leakage circuit breaker ELR of recommended make(Kilburn/L&T/MEI/GEC as per IS:2516-1977 with uptodate ammendements and of suitable of range which should have control box, operating,handle and trip/reset bush button on/off indicatorsre-indicating off spring condition of the circuit breaker for over current protection.The circuit should be equipped with magnet thermal release with metallic tape CTS, It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side and.suitable for 60 HP motor. |
102 | The voltage meter relay 3 phase with all protection and usual indicators and electric siran against single phasing, Low voltage high voltage reverse phasing over loading and phase voltage difference as per IS:3842(latest edition) |
103 | Digital 100 mm diameter circular dial A.C. supply volt meter of recommended make AE/IMP/Havells of suitable range with slector switches as per IS:4064-1978 with uptodate ammendements. |
104 | Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with up to date ammendments |
105 | Digital frquency meter of standard make AE/L&T/IMP/Havells as per relevant IS code with up to date ammendments |
106 | Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for netural phase as per IS:8084-1976 and IS:11353-1985 read with BIS-5578-1985 with uptodate ammendements |
107 | Providing and fixing of change over switch requiredcapacity of Kilburn/Larsen & turbo/ Standard/ Siement make andwith upto date ammendments immediatly after the power meter of HPSEB ICTP Main switch.i.make,ii.Type,iii. Range. |
108 | Three phase indicator lamps complete with toggie switches for individual motors as per IS:3452(P-I&II) with upto date ammendements. |
109 | Digital 100mm dia circular dia A.C. supply ammeter of A/E/IMP/Havells make of suitable range with selector switches andCTS operated as per IS:1248(P-II) 1983 with upto date amendements. |
110 | Capacitor of Mecheil/BHEL/GEC/L&T/ make as per IS 2834-1986 with upto date ammendements, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according toH.P. offered including cables as per relevent ISI code (of Siemens/Clocter/IEC make) from bus bar chamber to capacitor and also including ICPT switches of appropriate upto date ammendements. |
111 | Providing fixing suitable oil imersed Auto transformer/starter rotor starter of MEI/Kilburn/Jyoti /L&T/ Siemens/make as per IS:8544-1979 with upto date ammendements for squirrel cage/slip ring motor mountedon panel board with magentic type over load release and dashpot,time lag,under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS:1248(P-V)-1983 with upto date ammendements. |
112 | n) Providing Digital hour run meter of recommended make and suitables capacity as per IS :722 ( latest edition) |
113 | Providing & fixing 100mm dia circular dial pressure guage of fiebig /bourden PREGA/Precision make complete with all accessories such as stock cock, copper tubing etc. as per IS:3624-1987 with upto date ammendements. |
114 | Errection of all equipments i /c cost of tees bends lapers and any other fittings required as per site conditions and as per directions of Engineer-in-charge. |
115 | Providing double flanged CI sluice valve PN-1.0ofLeader/BHEL/Kirlosker/ GLEd/Kilburn Fourses / Kartar make and equal to dia ofsuction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments. |
116 | Providing& fixing double flangedcaststeel reflux valve of leader/BHEL/ Kirloskar/Kilburn/Fouress/KSB make and ofequal to dia of the pump delivery and capable of with standing the normal sheet pressure as per BIS-1868 API -600 with upto dateammendements.class ASA-300 STP 104 kg/cm2 |
117 | Providing double flanged CS sluice valveofLeader/BHEL/Kirlosker/ GLEd/ Kilburn Fourses / Kartar/KSB make and equal to dia ofpump delivery and capable of withstanding the normal seat pressure as per API -6D with upto date ammendments. Class ASA-300 STP 104 kg/cm2 |
118 | Providing& fixing double flangedcaststeel reflux valve of leader/BHEL/ Kirloskar/Kilburn/Fouress/KSB make and ofequal to dia ofrising main and capable of with standing the normal sheet pressure as per BIS 1414/ API 600 with upto dateammendements.class ASA-300 STP 104 kg/cm2 |
119 | Providing and fixing double flanged G.I./MSERW piping work(layout to be approved by the Engineer-in-charge work for suction and delivery pipe suitable of pump(S) offered and common header as per the Rising main respectively complete with all specials such as bends Rising main respectively complete with all specials such as bends tees, reducers, increasers,with companion flanges matching with the IS specification of the accessories including rubber/ asbostos gasket of 3mm thickness as per IS 2712-1979 and required number of nuts and bolts as per IS 1364-1983.The pipe shall be as per relevent IS code and to with stand 1.5 times total head stipulated under item No.1. The size of the various component to be as under:- |
120 | Suction pipe 150mm diaGI Pipe |
121 | Delivery pipeMSERWPipe |
122 | Common headerMSERWPipe |
123 | Providing and laying copper PVC insulatedarmured power cable (one cable carrying all the three phases) of 3 core suitable size and capacity to motors and all other electrical equipments as per IS: 1554(P-I) 1988 or latest with upto date ammendements of siemens/Gloster/IEC/ICC/EICO/ National/ GRANDLY make including all other accessories such as thimble, flaxible pipes, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
124 | Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode completewith material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail