Tender For Pre-Fabricated Canopies At Retail Outlets Under South Zone - Standing Rate Contract -END TERMINATION End termination of following cable with double compression NFLP gland and crimping sockets 4CX2.5 SQMM END TERMINATION, O INSTALL SUPPLIED LED FIXTURE OF CANOPY OR YARD LIGHT AT RETAIL OUTLETS OR OTHER PREMISES AS DECIDED BY HPCL. WORK INCLUDES PICKING UP OF FIXTURES, ACCESSORIES, CUT OUTS, CONTROLLERS ETC. FROM REGIONAL OFFICE, TRANSPORTING, STOCKING AT RETAIL OUTLETS. COST TO INCLUDE INSTALLATION OF FIXTURE AS PER MANUFACTURER RECOMMENDATION, WITH CHAIN OR GI WIRE HOLDING STRAPS, ACCESSORIES, MATERIAL, LABOR ETC.. VENDOR TO FOLLOW INSTRUCTIONS OF EIC FOR DECIDING THE LOCATION OF FIXTURE. CABLE, GLANDS WILL BE PAID EXTRA IF PROVIDED BY VENDOR, Supplying, transporting, fabricating, erecting in position in position of Pre- fabricated steel structures at all elevations for Canopy using structural steel sections ISMB/ISMC/ISA conforming to IS:2062 and IS 226 , including cutting, welding or bolting, supply of bolts/nuts/washers etc., complete as per drawings including surface preparation and applying one coat of Zinc Phosphate Primer before erection, one coat after erection and two coats of synthetic enamel paint as per specification after erection and all materials and labour complete. ( No welding is permitted at site). The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes and any other consumables required for completing the work. Nut bolts shall not be considered for payment.Theoretical wight of steel sections shall be considered for payment..(.(No measurement shall be taken for nut,bolt,washer splice plate & gusset plate), Supply and fixing Clippon Roofing System:Roofing base material should be of cold rolled steel of 0.55 mm thick and conform to ASTM:A 446 having yield stress of 275 MPA . The coating should be Aluminum and Zinc alloy comprising 55% Al , 43.5 Zinc & 1.5 % Silicon , as per ASTM :A 792 . The coating mass should not be less than 150 Gms per SqM (total of both sides). For, bare galvalume, TCT should not be less than 0.55 mm . Sheets shall have approved side laps with top sheets facing away from the prevailing weather. Necessary profiled filler box should be provided at higher level of roof sheeting and at valley gutter to ensure water tightness in the profiled gaps . The fixing of roofing shall be done in such a manner that the roof is not drilled / punctured for fixing with the purlins .Refer to the approved makes given in the Attachment. Flashings, Cappings and trims:These shall be formed out of same substrates as that of the roofing sheets and shall be supplied in standard lengths of 2.5 M in the required shapes and girths and fixed by means of hex-head mechanically galvanized stitching screws. Silicon sealant non-hardening neutral cure type shall be applied at all laps to avoid water seepage, Providing & fixing false ceiling system of Trac 150 F exterior grade or approved equivalent of 0.5mm thick galvanised steel with stove enameled coil coated finish inter locking ceiling panels, carriers, suspension system and edge closure as per the following specification. Supplying and installation of exterior grade 150 F ceiling system comprising of 150 mm x 17 mm deep panels roll formed out of 0.5 mm galvanised steel with stove enameled coil coated finish. The panels shall be pre-treated and coil coated on one side in manufacturers standard colour shades as approved by the Architect/ Engineer in charge. The rear side of the panel shall be given a coat of primer and a wash coat while the finished side shall be given a coat of primer and finish colour coat in polyster paint for a min. dry film thickness of 20 microns, fixed on to the roll formed carriers 34.5 mm x 488 mm deep out of 6 mm thick Galvanised steed with prongs to hold panels in the module of 150 mm at maximum 1.2 mts. C/C. The carriers to be suspended from roof truss by rigid suspension angles as per manufacturers recommendation. Panels shall be supplied in custom length upto maximum of 5 mts. Job also includes providing ceiling flashing using factory formed 0.5 mm thick Polyster coated galvanised steel material. Rate shall be including providing flashing to cover gap if any between illuminated banding and false ceiling, Supplying and fixing 20 SWG GI sheet facia including painting with one coat of zinc chromate primer and two coats of 1 st quality synthetic enamel paint on front side . Necessary facia framework for fastening the sheet to the canopy securely shall be paid separately, Supply and laying following size PVC insulated, sheathed, armoured cable of approved make conforming to IS 1554:Part 1:1988 4CX2.5SQMM COPPER CABLE, Providing and fixing 6 dia PVC pipes of 6 Kg/sqcm of approved Make as per IS 4985 for rain water pipes including all fittings like bands , shoes etc., MS fabricated bracket as per requiment etc. All complete as directed by the EIC, Providing and fixing 2 mm thick Aluminum Sheet Gutters of required shape in slope with 40 mm x 3 mm MS. Brackets at 1000 mm maximum spacing and 8 mm dia G.I. J or L hooks, boltsand nuts, GI Limpet and bitumen washers, providing nut bolt joint , sealing the joints with silicon sealant testing the gutter for leakage by filling water etc. Complete.(Refer attached Drawing .For allowable tolerance refer to IS codes, Providing and fixing 4 dia PVC pipes of 6 Kg/sqcm of approved Make as per IS 4985 for rain water pipes including all fittings like bands , shoes etc., MS fabricated bracket as per requiment etc. All complete as directed by the EIC, SUPPLY AND LAYING FOLLOWING SIZE PVC INSULATED,SHEATHED,ARMOURED CABLE OF APPROVED MAKE CONFIRMING TO IS 1554: PART 1:1988- 3C X 1.5 SQMM COPPER CABLE, etc.