Construction Of Mission Shakti Bhawan At Kantapada Block For 2021-22. Construction Of Mission Shakti Bhawan At Kantapada Block For 2021-22.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation in hardsoil including rough dressing and levelling the beds within 50m. initial lead and 1.5m. initial lift with cost, conveyance, taxes as per specification and directionof Engineer in charge. |
| 2 | Filling foundation and plinth with good quality river sand with watering and ramming incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge |
| 3 | Cement concrete (1:3:6) in foundation and plinth using 4cm(1½”) size hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 4 | RCC work ofM-20 Grade with 20mm and down graded size crushed stone aggregates mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including cost, conveyance, cost of all labour, T&P, cost of all materials etc. complete as per direction and specification of Engineer-in-charge.a ) Column Base |
| 5 | b) i) Plinth Band |
| 6 | c) i) Lintel and RCC band at window sill level |
| 7 | (ii) Lintel (1st floor) |
| 8 | d) Beam & column (GF) |
| 9 | Beam & column (1st floor) |
| 10 | e) i) Roof Slab |
| 11 | f)Chajja (GF) |
| 12 | (I) 1st floor |
| 13 | h)Staire Case |
| 14 | Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL includingbending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge i)Ground Floor |
| 15 | 1st floor |
| 16 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation & Plinthand for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge. i) Ground floor |
| 17 | Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge. i) Ground floor |
| 18 | (ii) 1st floor |
| 19 | Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. i) Ground floor |
| 20 | 1st floor |
| 21 | Providing 16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. i) Ground floor |
| 22 | 1st floor |
| 23 | Providing 20mm thickGrading plaster in cement mortar (1:4) in all floors finished smooth to Roof surfacecleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. i) Ground floor |
| 24 | Fininshing Surface of walls with cement based wall putty water bound of approved make and finsished smooth surface to receive painting including cost conveyance etc complete as per specification & direction of Engineer-in-charge. |
| 25 | Providing 6mm thick cement plaster.(1:4) to RCC surface finished smooth including closed deep chiping and slury treatment including watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge Ground floor |
| 26 | 1st floor |
| 27 | Supplying, fitting & fixing in all floors of M.S.grills and gates, with top rails, steel windows, critical frames for windows balustrades of stair case and parapet railing made out of M.S.square bar/flat as per approved drawing and design including making holes in walls and RCC structure, wood work etc and making good to the damages to walls with cement concrete(1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size(20mm size not to exceed 25%) of approved quality with cost of all materials labour, cost of welding all T&P, sundreis etc complete in all respect as per specification and direction of Engineer in charge(screws and other hardward required materials to be used in the work shall be of approved quality and specification and shall have to be supplied by the contractor at his own cost . |
| 28 | Providingfitting and fixing of Vetrifiedtiles in floors of approved makeover 20mm thick cement mortar(1:4) including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 29 | Providingfitting and fixing of Ceramic Walltilesof approved makeover 12mm thick cement Plaster (1:3) jointed with need cement slurry including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 30 | Painting two coats with a coat of approved synthetic enamel paint over a coat of redoxide primerin wood/ ironwork including sand papering, polishing the surface, cost, conveyances ofmaterials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge. (GF) |
| 31 | 1st floor |
| 32 | Painting two coats with Weather Seal Coat of approved shade over a coat of white washupto any height by means of brush to surface of walls after cleaning the surface including watering, curring etc. complete in all floors including cost, conveyance, taxes of all materials, labours sundries T&P required for the work as per specification and direction of Engineer in charge (GF) |
| 33 | 1st floor |
| 34 | Painting two Coat with plastic emulsion paint of approved shadeover a coat of cement primer upto any height by means of brush to surface of walls after cleaning the surfaceetc. complete in all floors including cost, conveyance, taxes of all materials, labours sundries T&P required for the work as per specification and direction of Engineer in charge (GF) |
| 35 | 1st floor |
| 36 | Providingfitting and fixing ofgranite tiles in floors, treads or steps of approved makeover 25mm thick cement mortar(1:1) including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 37 | supply of fitting and fixing paver block of 60mm thick in floors of approve quality over 50mm thick sand base including cost of paver block and all materials labour T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 38 | Cement concrete (1:2:4) using 12mm size hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 39 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe wiht Balustrade of size 32 x 32 x 2mm @ 0.90mtr C/C and stainless square pipe bracing of size 32 x 32 x 2mm in 3 rows in stair case as per approved design andspecification buffing polishing etc wiht cost conveyance taxes of all materials labour T&P etc.required for th ecomplete in all respect. |
| 40 | Providing G.S.B with close graded Gr-IV stone screening materials as per approved Drawing & technical specifications and as per Clause-401 of MoSRT7H specifications of road & Bridge work. |
| 41 | Dressed seasoned sal wood work framed and fixed (Wrought and put up) in truesses, purliness, frames of doors, windows, ventilelabours and beams with cost, carriage of all materials, etc compltete. |
| 42 | Providing and fixing of louvered glass ventilator of approved make to be fabricated from roll formed sections made of pre-painted steel(base steel as per IS-513 of 0.6mm thick \"D\" quality, galvanised as per IS-277 with zinc of 120 Gm/sqm) with total coated thickness of 0.5mm slide guide section should be made of 0.5mm sainlesssteel of 430 grade with paint specification being with primer of 5-7 microns and finished paint with polyster paint(Black/Pearl white/chocolate Brown) of 12-16 microns along with the alkyd backer at the back of 5-7 microns and the section for external frame bottom and top should be of 79x49mm extrenal frame side should be 69x24mm guide for top and bottom should be of 69x26mm. section for shutter should be of 23x57mm. accesory / gasket are tobe used as perb the mfg supply and specification like gasket will be made up EPDM.All croner brackets for internal and external are to be made up glass filled nylon. the section are to be cut to length joined and assembled by means of croner brackets and frames are fixed to the concrete / machinery wall by means of self expanding screws and glass to be used of 5mm refelctive with all taxes complete. |
| 43 | Providing fitting and fixing of 32mm thick flaush door shutter made up 30mm thick solid core flaush door shutter as per IS 2202 with 5mm thick vision panel including cost conveyance of all materials labour T&P reqired for the work. As per specification and direction of Engineer in Charge. |
| 44 | Providing and fixing of sliding windows of approved make to be fabricated from roll formed sections made of pre-painted steel(base steel as per IS-513 of 0.6mm thick \"D\" quality, galvanised as per IS-277 with zinc of 120 Gm/sqm) with total coated thickness of 0.5mm slide guide section should be made of 0.5mm sainlesssteel of 430 grade with paint specification being with primer of 5-7 microns and finished paint with polyster paint(Black/Pearl white/chocolate Brown) of 12-16 microns along with the alkyd backer at the back of 5-7 microns and the section for external frame bottom and top should be of 79x49mm extrenal frame side should be 69x24mm guide for top and bottom should be of 69x26mm. section for shutter should be of 23x57mm. accesory / gasket are tobe used as perb the mfg supply and specification like gasket will be made up EPDM.All croner brackets for internal and external are to be made up glass filled nylon. the section are to be cut to length joined and assembled by means of croner brackets and frames are fixed to the concrete / machinery wall by means of self expanding screws and glass to be used of 5mm refelctive with all taxes complete. |
| 45 | Supplying fitting fixing of big six or trafford A.C sheets in roof including fixing of ridges wind ties etc complete including cost, carriage taxes of all materials and all labour T&P required for the work. |
| 46 | Supply fitting fixing of 50mm dia GI pipe in roof for fixing of AC sheets including cost, carriage taxes of all materials and all labour T&P required for the work. |
| 47 | E.I - Recessed wiring to light point/ fan point/Exhaust fan point/Call bell point with 1.5sqmm FR PVC Insulated single core multistarand copperConductorof ISI marked with 20mm dia non metalic PVC flexible conductwith 6A 250V MODULAR type switch ISI marked and ceiling rose marked mounted on Modular GI Boxhaving front modular base plateof suitable size, with 1.5sqmm FR PVC Single core multistrand copper conductor as earth wire includingallaccessories and connection as per direction of Engineer in charge (Make of wire Finolex / Havells / Anchor / Finolex/Polycab) switch /socket/modular GI Board(Make-Legrand ) light pointGroup-A |
| 48 | -do-light pointGroup-B |
| 49 | -do-light pointGroup-C |
| 50 | -do- Fan point Group-A |
| 51 | -do- Fan point Group-B |
| 52 | Recessedwiring to 6 AMPModular socket out let with 2x1.5sq mm for FRLS PVC insulated single core multistrand copper conductor of ISI marked in reccess20mm dia non metalic PVC flexible conduit Modular GI Box and earthing point with1x1.5sqmm FR PVC insulated single core multistarnd copper conductor for loop earthing etc,as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells / Anchor /Polycab) switch /socket/modular GI Board Existing board(Make-Legrand ) |
| 53 | Supply and fixing of Multipurpose board having prov. Of 2Nos 6Amp plug with 6Amp switch on existing board (Modular)(Make-Legrand ) |
| 54 | Supply and fixing of Multipurpose board having prov. Of 2Nos 5 pin,15/16 AmpModular socket out letand 15/16 AmpModular switch ISI marked connection painting etc as required complete in all respect as per direction of Engineer in charge (Make-Legrand ) |
| 55 | Recessed Extra leadSub-main wiring for light and fan point 2x1.5mm2FR PVC insulated single core multistrand copper conductor of ISI Marked confirming to IS-694/1990 in 20mm dia nonmetalic heavy duty flexible conduct 1.6 sqmm thick along with 1x1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells / Anchor / Finolex/Polycab)2x1.5 sqmm +1x1.5 sqmm1100 Volts confirming to IS 694/1990 |
| 56 | Recessed wiring to Sub-main in 2x2.5 sqmm FR PVCinsulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mmdia non metalic heavy duty flexible conduct 1.6mm thick along with 1x1.5sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells / Anchor / Finolex/Polycab)2x2.5 sqmm +1x1.5 sqmm1100 Volts confirming to IS 694/1990 |
| 57 | Recessed wiring to Sub-main in 2x4 sqmm FR PVCinsulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mmdia non metalic heavy duty flexible conduct 1.6mm thick along with 1x1.5sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge(Make of wire Finolex / Havells / Anchor / Finolex/Polycab) 2x4 sq mm+1x1.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 58 | Recessed wiring to Sub-main in 2x6 sqmm FR PVCinsulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mmdia non metalic heavy duty flexible conduct 1.6mm thick along with 1x2.5sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge(Make of wire Finolex / Havells / Anchor / Finolex/Polycab)(Mainswtich/Busbar to MCB DB box) 2x6 sq mm+1x2.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 59 | Recessed wiring to Main in 4x6 sqmm FR PVCinsulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mmdia non metalic heavy duty flexible conduct 1.6mm thick along with 2x2.5sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells / Anchor / Finolex/Polycab)4X6sq mm+2x2.5 sqmm 1100 Volts confirming to IS 694/1990 |
| 60 | Supply of 25mmsq. mm 3 1/2 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable (Make-Polycab /Havells/Finolex) |
| 61 | LAYING OF CABLE 25mmsq. mm 3 1/2 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable |
| 62 | Supply and fixing of SP 6-32 A rating 240 V \"B\" series miniature circuit breaker suitable for lighting and other loadsin the existing MCB DB ISI marked complete with connections testing and commissioning completein all respect as per direction of Engineer in charge(Make : Schneider (ACTI 9 ) /legrand/siemens) |
| 63 | Supply and fixing of DP 6-32 A rating 240 /415V \"C\" series miniature circuit breaker suitable for lighting and other loadsin the existing MCB DB ISI marked complete with connections testing and commissioning completein all respect as per direction of Engineer in charge(Make : Schneider (ACTI 9 ) /legrand/siemens) |
| 64 | Supply and fixing of DP 63 A rating 240 /415V \"C\" series miniature circuit breaker suitable for lighting and other loadsin the existing MCB DB ISI marked complete with connections testing and commissioning completein all respect as per direction of Engineer in charge(Make : Schneider (ACTI 9 ) /legrand/siemens) |
| 65 | Supply and fixing of FP 6-32A rating 415V \"C\" series miniature circuit breaker suitable for lighting and other loadsin the existing MCB DB ISI marked complete with connections testing and commissioning completein all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand/siemens) |
| 66 | S/F of 4 way TPNMCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand/siemens) |
| 67 | S/F of 12 way Double Door MCB Box on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge(Make : Schneider (ACTI 9 ) /legrand/siemens) |
| 68 | Sypply of 48 inch / 1200mm A.C. Celling Fan High speed metalic colour ISI Marked with all connection complete in all respect as per direction of Engineer in charge Make:(Orient PSPO summer cool/Crompton High breeze/Almonard/Khaitan) |
| 69 | Fixing of above mentioned ceiling fan |
| 70 | S/F of step type electronic Fan RegulatorISI Marked with all connection completein all respect as per direction of Engineer in charge(Make-Legrand ) |
| 71 | S/F of 12 inchHeavy duty (Metalic Colour)Exahust Fan with wall cutting, S/F of proper size of hume pipe, concreating, plastaring, painting with all connection testing and commissioning complete in all respect as per direction of Engineer in charge Make:(Orient PSPO summer cool/Crompton High breeze/Almonard/Khaitan) |
| 72 | S/F of A.C. point consisting of 32 Amp single phase starter with all connection complete in all respect as per direction of engineer incharge (Make : Schneider/legrand/siemens) |
| 73 | S/F of 36 watt LED ceiling 2/2 Recess/Surface light fittings complete with all connections. Make- Phillip\"s/Havell\"s/Wipro/Orient/Panasonic) |
| 74 | S/F of Street light-ENDURA 90 W CITYLINER NEO new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover.(Phillips/Havells) |
| 75 | Fixing of Street light with G.I bracket and pipe |
| 76 | S/F of 63 A cubical panel boardmade of 16 SWG C.R sheet with powder coated with provision of following items with fabrication erection testing & comissioning of total enclosed panel board of size not less than 30\"x28\"x8\" with copper busbar of 63A, 415V 4strip & internal connection & provision for termination of incomming & out going cable , earthing etc, complete with supply & fixing of following switch gears.technical specification: |
| 77 | Supply and fixing of 4 pole MCCB 63-100A,Ics = 100% Icu, 16 KA breaking capacity, adjustableThermal,fixedmagnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required completein all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand/siemens) |
| 78 | Supply and fixing ofDigital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) IEC 62053-21 complete with connections testing and commissioning completein all respect as per direction of Engineer in charge (Make : legrand ) |
| 79 | Supply and fixing of 4 pole 63AMP changeover in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required completein all respect as per direction of Engineer in charge (Make : Schneider/legrand/siemens/L&T) |
| 80 | S/F of Earthing with medium class 40mm 3Mtr. Long ISI markedGI Earth pipe including accessories such as funnel GI nut, Bolt, washer , hinged cover plate with looking arrangement, 40mm to 20GI rediusor 5nos 20mm dia holes on GI pipe required charpol salt, Excavation of earth brick work in cement mortar complete in all respect as per specification of SR 2011 and asper Direction of Engineer-in -Chage |
| 81 | Supply and laying of 6 swggi wire in recess/surface |
| 82 | Supply and fixing of 22watt,CW/WW 5700K,1800 Lumen led Aluminium Housing batten on wall ,making connections, etc. as required completein all respect as per direction of Engineer in charge (Make : Panasonic/ Great white/ Orient/ wipro/ Havells) |
AI Tender Summary
Tender Timeline
Dec 17, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedDec 27, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 28, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender