}

Supply Of , Bioabsorbable Interference Screw ( 7 / 8 / 9 / 10 / 11 ) , Bio Rc Interference Screw For Acl Reconsruction ( Bptb Graft ) Surgery Us Fda / Eu-Ce ( Full Quality Assurance ) ( Compatible With Mri ) ( Instrumentation And All Sizes Of Imp, 151 BASE HOSPITAL-Assam

Indian Army has published Supply Of , Bioabsorbable Interference Screw ( 7 / 8 / 9 / 10 / 11 ) , Bio Rc Interference Screw For Acl Reconsruction ( Bptb Graft ) Surgery Us Fda / Eu-Ce ( Full Quality Assurance ) ( Compatible With Mri ) ( Instrumentation And All Sizes Of Imp. Submission Date for this Tender is 30-12-2021. Cutting Crimping and Punching Tools Tenders in 151 BASE HOSPITAL Assam. Bidders can get complete Tender details and download the document.




Tender Notice

30323565
Supply Of , Bioabsorbable Interference Screw ( 7 / 8 / 9 / 10 / 11 ) , Bio Rc Interference Screw For Acl Reconsruction ( Bptb Graft ) Surgery Us Fda / Eu-Ce ( Full Quality Assurance ) ( Compatible With Mri ) ( Instrumentation And All Sizes Of Imp
Tender
Indian
Assam
151 Base Hospital
30-12-2021

Tender Details

Supply Of , Bioabsorbable Interference Screw ( 7 / 8 / 9 / 10 / 11 ) , Bio Rc Interference Screw For Acl Reconsruction ( Bptb Graft ) Surgery Us Fda / Eu-Ce ( Full Quality Assurance ) ( Compatible With Mri ) ( Instrumentation And All Sizes Of Implants To Be Provided At The Time Of Surgery ) ( Pre-Sterilised ) , Vapr Probe ( 3-4 Mm / 4-5 Mm ) For Ablation And Coagulation ( Pre-Sterilised With Cable For Attachment To Mitek ) Assorted Size Us Fda / Eu-Ce ( Full Quality Assurance ) , Tibial Post Fixation Screwsfor Acl Reconstruction Dia 6.5Mm Length 30 Mmmanufacturer Must Have Manufacturing Licence On Form 9 By Cdseo, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified , Metallic Suture Anchor 5Mm , Flipcutter:- Asterile Disposable Retro Construction All -In-One Guide Pin Reamer That Allows Minimaly Invasive Socket Creation From The Inside Out. The Diameter Of The Instrument Should Be 3.5Mm And It Changes From A Drill Pin To Retrograde Reamer By Simply Pushing A Button And Sliding The Blue Housing Forward.A Retrograde Reaming Is Done For Creating Sockets In Femur And Tibia In Acl, Pcl Reconstruction & Meniscal Root Repair. The Disposable Instrument Shouldbe Available In Sizes 6 Mm-13Mm, In Half Millimetre Increments As Single Sterile Pack Of Each Size. , Bc Screw:- A Bioabsorbable Interference Screw Made Up Of 70% Pldla And 30 %Biphasic Calcium Phosphate Required For Graft Fixation In Arthroscopicor Open Ligament Reconstruction , It Should Be Availablein Diameter From 6 Mm-12Mm And Length 23, 28, 35Mm. , Fiberstich:-Sterile, Dispoisable , All Inside Meniscalb Repair Device With 2 All Suture ( Made Up To Braided 4-0 &6-0 Non Absorbable Polyster Suture ) Implants And 2-0 Coreless Uhmwpe Suture. The Needle Of The Device Should Have 12 Degree Up Curve Low Profile. 1.8 Mm Diameter. The Device Should Facilitate Active Deployment Of Implants And It Should Produce A Single Stitch Knotless Double Mattersconfiguration With Compleate Meniscal Tear Closure. , 2-0 Fibrewire:_ An Uhmwpe Multifilament 2- 0 No Suture Braided With Polyster Jacketfor Smooth Handing And The Length Of Suture Should Be 96 Cm To Be Used For Variousmeniscal Repair Procedures. , 5 Mm Titanium Corkscrew_ Asterile Disposable Knotted 5 Mmm * 15.5 Cmm Titanium Self Punching Tap-In Anchor For Open Or Arthroscopic Rotator Cuff Repair And With Double Loaded Made Up Of #2 Uhmwpe Braided With Polyster Coveringfor Ease Of Suture For Ease Of Suture Handling. , Knee Scorpion Needle :_ A Sterile Disposable Needle Compaitable Withresuable Knee Self-Retrieving Suture Passer Instruments ( Knee Scorpion ) The Width Of The Needle Tip Should Be 1.5Mm And It Should Engage#2-0, #0 Uhmwpe Sutures For Various Arthroscopic Meniscal Repairprocedures. , Bio Rci- Hascrews ( Alternative Of Poly- Lactide ( Pla ) And Hydroxylaptite ( Ha ) To Metalscrews Biorci-Ha Screws Are Strong When Needed. , Biosure Regebesorb Interference Screw ( With Dual Osteoconductivecomponants Of 15% B-Tcp, 20% Calcium Sulfate And 65% Of Poly Lactic-Co-Glycoilc Acid ( Plga ) , Transparnt Track Cannula For Shoulder Arthroscopy With Valve For Inflow And Outflow ( 6 / 7 / 8 / 9 ) Mm With Membrane Usfda / Eu-Ce ( Full Quality Assurancce ) ( Pre Sterilised ) , Arthrscope 4Mmx 70 Degreespecification:Wide Angle , Direct View High Defination Arthroscopic Compatible With A J-Lock Fixation For Canulla; Workin Length Of Not More Than 160 Mm;Optimal Center -To-Edge Resolution For Enhance Picture Quality ; Angle Of View : 70 Degree ; Diameter 4Mm; Fibre Optic Light Transmission Incorporate;Standard Ocular Window For Coupling The Camera Head ;Scratch Resistance Saphire Quoted Tip Lens;Advanced Rod Lens System For Optimum Brightness Contrast And Defination; Arthrocopy Shuold Be Supplied With Compatible Cannula High Flow Double Valve Fully Rotatable With Fenistrated Tin & Conical And Blunt Obturator. , Trocar & Sheath Specification: Light Guide Insertion On Opposite Side Of The Direction Of View With A J- Lock Fixation For Cannula; Sheath - 5.95 To 6Mm High Flow Diagnostic Cannula , Doublevalve Rotatable Canulla With Fenestrated Tip; Trocar -4.5Mm Conical Obturator To Fit With Cannula , Cannula Inserter Compatible With Smith And Nephew- 07 Mm , Cannula Inserter Compatible With Smith And Nephew- 08 Mm , Mixter Forcep , Driver, Biocomposite Interference Screw ( Arthrex ) , Portal Skid, Suture Tensioner / Cutter For 2-0 And 0 Fiberwire ( Arthrex ) , 3.5 Mm Lcp Medial Distal Humerus Plate Rt & Lt ( 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 11 Holes ) For Shaft And 3-5 Holes For Articular / Extra Articular Medial Condylar Fragment With 6 X2.4 / 2.7 / 3.5 Locking And 2 X Cortical Screws Complete Construct.Implants Should Be Usfdaand Ce ( European ) Certified, Mri Safe , 3.5 Mm Lcp Postero-Lateral Distal Humerus Plate Rt & Lt With / Without Lateral Extension ( 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 11 Holes ) For Shaft And 4-5 Holes For Articular / Extra Articular Lateral Condylar Fragment With 8 X2.4 / 2.7 / 3.5 Locking And 2 X Cortical Screws Complete Construct..It Should Be Usfdaand Ce ( European ) Certified, Mri Safe. , Wire ( Kirschner ) 20 Cm Long X ( 1.0, 1.5Mm, 2Mm, 2.5Mm, 3Mmdia ) . 316Lvm Stainless Steel. , Distal Radius Fixator System With Adjustable Angles And Distraction - Distal Radius Fixator, 2 X Tapered Half Pin Dia 4 Mm Amd 2 X 3Mm Dia Shanz Pins.Manufacturer Must Have Manufacturing Licence On Form 9 By Cdseo, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified, , 2.4 / 2.7 Mm Volar Distal Radius Locking Plate With 5 Holes In Horizontal / Oblique Distal Part In A Single Row And ( 2 / 3 / 4 / 5 / 6 / 7 Holes ) In Longitudinal Part Of Plate With 5 X Locking And 2 X Cortical Screws Complete Construct. Implants Should Be Usfda And Ce ( European ) Certified, Mri Safe. , Tibia Nailing System ( Expert Type Titanium ) Consisting Of Expert Tibial Nail 1 Nos, Locking Bolt 5 Nos, Endcap 1Nos, Size ( 8 / 9 / 10 ) , Proximal Femoral Nail ( Titanium ) Long Length With Neck Locking Screws And Distal Locking01 Bolt . ( Manufacturer Must Have Manufacturing Licence On Form 9 By Cdseo, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified , 7 Hole 3.5 Mm Titanium Dcp Plate With 16 Mm Cortical Screw10 Nosmanufacturer Must Have Manufacturing Licence On Form 9 By Cdseo, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified, , 8 Hole 3.5 Mm Titanium Dcp Plate With 18 Mm Cortical Screw10 Nosmanufacturer Must Have Manufacturing Licence On Form 9 By Cdseo, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified, , Ao Pattern Lc-Dcp Plate 4.5Mm- Narrow ( 8 / 10 / 12 / 14 / 16 Holes ) With 9 Self Tapping 4.5Mm Cortical Screws Complete Construct-Titaniummanufacturer Must Have Manufacturing Licence On Form 9 By Cdseo, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 19.12 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail