Public Administrative Department Local Bodies Closing in 0 days TDR #30320345

Upgradations And Renovation Work Of T.R.H Rishilok, Muni Ki Reti Distt- Tehri Garhwal

Issued by Local Bodies · MUNIKIRETI, DISTT-TEHRI GARHWAL, Uttarakhand
Tender Value
86.97 Lakhs
Estimated cost
Bid Submission
30 Dec 2021
0 days left
EMD
1.74 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
MUNIKIRETI, DISTT-TEHRI GARHWAL → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Upgradations And Renovation Work Of T.R.H Rishilok, Muni Ki Reti Distt- Tehri Garhwal

BOQ

Name of Work: UPGRADATIONS & RENOVATION WORK OF T.R.HRISHILOK, MUNI KI RETI DISTT- TEHRI GARHWAL
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
3Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
4Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
5Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
6Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
7Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.2 0.80 mm thick with zinc coating not less than 275 gm/m²
8Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
912 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
10Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
11Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
12Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
13Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
14Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
15Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
16Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
17Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
18Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazingand false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
19Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
20Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New wok (two or more coats) over and including water tinnable priming coat with cement primer
21French spirit polishing :Two or more coats on new works including a coat of wood filler
22Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical andchemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
23Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
24Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
25Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
26Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (Angle 40x40x5)
27Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
28Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
29Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
30Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
31Providing and fixing PTMT swivelling shower, 15 mm nominal bore, sweighing not less than 40 gms
32Providing and fixing toilet paper holder : C.P. brass
33Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
34Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
35Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia
36Providing and fixing 100 mm sand cast Iron grating for gully trap.
37Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
38Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 40 mm nominal size)
39Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat ofneat cement complete as per standard design :18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
40WGPVCMOD Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as
41Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. -GroupA
421.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. Each 285
431.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess withsuitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. Each 406
44Supplying and flxing suitable size GI box with modular plae and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings
45Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
46Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1.22.1 75 mm X 75 mm X 60 mm deep-100 mm X 100 mm X 60 mm deep Each 160
47Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1.22.1 75 mm X 75 mm X 60 mm deep -180 mm X 100 mm X 60 mm deep Each 183
48Supplying and fixing following size/ modules, Gl alongwith modular base & cover plate for modular switches in recess etc. as required -1 or 2 Module (75mm x 75mm)
49Supplying and fixing following size/ modules, Gl alongwith modular base & cover plate for modular switches in recess etc. as required -3 Module (100mmX75mm) Each 267
50Supplying and fixing following size/ modules, Gl alongwith modular base & cover plate for modular switches in recess etc. as required -8 Module (125mmX125mm)
51Supplying and fixing following modular switch/ socket on the existing modularlate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
52Supplying and fixing following modular switch/ socket on the existing modularlate & switch box including connections but excluding modular plate etc. as required. -3 pin 5/6 amp socket outlet
53Supplying and fixing following modular switch/ socket on the existing modularlate & switch box including connections but excluding modular plate etc. as required. -TV antenna socket outlet
54Supplying and fixing following modular switch/ socket on the existing modularlate & switch box including connections but excluding modular plate etc. as required. -Telephone socket outlet
55Supplying and fixing following piano type switch/ socket of the existing switch box/ cover including connections etc. arequired. 1.23.1 5/6 amps switch Each 45 -5/6 amps switch
56Supplying and fixing following piano type switch/ socket of the existing switch box/ cover including connections etc. arequired. 1.23.1 5/6 amps switch Each 45 -3 pin 5/6 amp socket outlet
57Supplying and fixing following piano type switch/ socket of the existing switch box/ cover including connections etc. arequired. 1.23.1 5/6 amps switch Each 45 -TV antenna socket outlet
58Supplying and fixing following piano type switch/ socket of the existing switch box/ cover including connections etc. arequired. 1.23.1 5/6 amps switch Each 45 -Telephone socket outlet
59Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
60Telephone wiring in existing conduit:Supplying and drawing following pair, 0.5 sq mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/recessed steel/ PVC conduit as required. -2 Pair
61TVWGEC TV cable in existing conduit: Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
62PVCCON S/F PVC conduit: Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cuttting the wall and making good the same in case of recessed conduit as required. -25 mm
63WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. -2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
64WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. -2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
65WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. -2 X 4 sq. mm + 1 X 4 sq. mm earth wire
66WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. -4 X 6 sq. mm + 2 X 6 sq. mm earth wire
67Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. -3 x 1.5 sq. mm
68Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. -3 x 2.5 sq. mm
69Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.-3 x 4 sq. mm
70Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. -4 x 6 sq. mm
71Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copperbusbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnectios, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) -8 way, Double door
72Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phoshatized and powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)-4 way (4 +12), Single door, hotizontal type
73Supplying and fixing following rating, Duble pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required.-40amps
74Supplying an fixing following rating, four pole,(three phase and neutral), 415volts isolator,. as required. -100 amps
75Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"C\" series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. -Single pole
76Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt ) as required.
77Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required.
78Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. -125 A, 16 KA,TPMCCB
79Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. -250 A, 35 KA,TPMCCB
80Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. -4pole isolator 100 amp
81Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. -2pole isolator 40amp
82Laying of one number additional PVC insulated and PVC sheathed / XLPE POWER CABLE OF 1.1 KV Grade of following size direct in ground in the same trench in one tier horizontal dormation including excavation and reflling the trench etc. as required , but excluding sandcustginoiing and protective covering.
83Supplying and fixingf of decorative LED tube light fiting 18W , 4 feet complete with making connection and complite with all respect directed /approved by E/I
84Suplly of PVC Insulated Alimnium XLPE sheathed cable 16sq. mm 4 core complete in all respect
85supplyfixing ofPVC insulated andsheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
86S/F oft LED FANCY WALL LIGHTdown9W complete with making connection complete in all respect. INCLUDE GST
87Supplying and fixing of changeover switch 250amps, 415 volts complete with makingconnections,in open execution complete in all respects as directed by E/I.
88S/F ofExhaust fan 230mm krypton HS Mtgray EF as approved by E/I complete with making connection in all respect . Including GSt, Cartage Labour Charges.
89Supply of fixingh of factory eired ISI/ ECRTIFIED LED street light 40-45 W Capacity pressure dia cast or extruded Aluminium housing with corrossion resistant polyster powder coated side entry type shall consist at separate and control gear campatoment thoughened glass energy afficenvy LP- 18 watt operation voltage 140-270 HZ freequency 140-270 V electronic driver with internal surge protection of 4 KV street light should be protected with short circuit open circuit Reverse polarity and automatic safe shut down after 300 V AC and below 100 V A.C as per direction by E/I complete in all respect.
90S/Febrication of wired metal clad dust & verming proof floor mounting /wall TPN swich bord complete with following rating MCCB wuth instrument chember etc , the inssstument chember shall be eprated and shall compriss of flush type ammeter , voltmeter ,slector swith for amp & voltmeter ,fuse current Tranfer etc . the The board whall hare suitable capacity electrolytic al bus bar as per LS 8623 insulated with leat shirk sleeving and mounted ditecheable side cover comlete in all respect

AI Tender Summary

OUR REF NO 30320345
AUTHORITY Local Bodies
TENDER VALUE 86.97 Lakhs
LAST DATE 30-12-2021
Authority
Authority Name Garhwal Mandal Vikas Nigam Ltd
Work Description Upgradations And Renovation Work Of T.R.H Rishilok, Muni Ki Reti Distt- Tehri Garhwal
Basic Detail
Tender No GMVN- ENGG- RISHI
Bidding Type Tender
Location
City MUNIKIRETI, DISTT-TEHRI GARHWAL
State Uttarakhand
Key Dates
Publish Date 16 Dec 2021
Submission Date 30 Dec 2021
Open Date 30 Dec 2021
Finance
Tender Value 86.97 Lakhs
Tender Fee 4720
EMD 1.74 Lakhs
Exemption Not Available
Document List
2d2f2938-4cd8-4182-bf6d-22dd712b856e.html
BOQ_47523.xls
dcrishi1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 16, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 30, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 30, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2d2f2938-4cd8-4182-bf6d-22dd712b856e.html

xls

BOQ_47523.xls

pdf

dcrishi1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail