| 1 | Repair & White Wash of Pump Chamber |
| 2 | Dismantling cement Concrete plan 1:2:4, 50mm thick |
| 3 | Conglomerate floor 50mm thick cement concrete rate 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling |
| 4 | Hollock wood doors shutter windows including Hinges, Screws, Chocks Cleats, Stops and Cords etc. complete fixed in position (double Leaf) @ Paneledglazed or glazed and paneled |
| 5 | Applying Pink Primer or-aluminium priming coat including preparation of surface With special quality paint |
| 6 | Painting two or morecoats excluding priming coat with synthetic enamel readypaint in all shades onwood workmetallic or plastered,concrete surface to give an even shade |
| 7 | Supply & fixing of pressed steel frames (chowkats) consisting of 18 gauge (1.25mm thick steel sheet of specified section standard design latest) including iron lugs (hold fasts) for iron hings conforming to PWD specification including bolts for fixing stops lock, netch bolts, hydraulic spring and finished with one priming coat of approved quality fixed in position including cost of cement concrete 1:3:6 for filling in the frame and cement concrete for 1:2:4 for lugs complete. |
| 8 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15cm layers including ramming watering and consolidating lead upto 30 meters. |
| 9 | White washing 3 coats inside of pump chamber. |
| 10 | Finishing wall with exterior decorative cement based paint such assnowcem robbiacem etc.two or more coats to give even shade. ” |
| 11 | Providing and fixing of Glass strips 4mm thick in floors |
| 12 | 50mm wide |
| 13 | 40mm wide |
| 14 | Preparationofplasteredsurfacesfor distempering including surface, applying fillingwith approved quality filler consisting ofplasterofParisandchalkmittiincludingfinishingthesurfacetotherequiredfinish complete. Inside pump Chamber. |
| 15 | Distempering with dry distemper of approved manufacture two or more coats over one priming coat to give an even shade. |
| 16 | Supplying & fixing glass panes with glazing clip andspecial metal sash putty of approved make. |
| 17 | Dismantling cement conglomerate floors (25mm to 50mm) thick without concrete base |
| 18 | Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent |
| 19 | Providing and fixing of electric tube set of reputed make |
| 20 | Repair ofExpansion Joints 150 mm i/d (For 150000 ltr Capacity OHSR) |
| 21 | DEVELOPMENT OF WATER WORKS SITE. |
| 22 | Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 9.34 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects as per DWSS standard Drawing and analysis. |
| 23 | Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4\" x 3\", size top 3\" x 3\",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. |
| 24 | Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm as per DWSS standard Drawing and analysis. |
| 25 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per DWSS standard Drawing & Analysis. |
| 26 | Repair of Gate Pillar |
| 27 | Earth work in excavation in foundations trenchesetc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth includingdressingofbottomandsidesof trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 28 | Cement Concrete 1:8:16 with stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumeturic type |
| 29 | First class Burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 30 | First class Burnt Bricks work laid in cement sandmortar 1:5 in first storey upto 4 meters above plinth level |
| 31 | 12.5 mm thick cement plaster 1:5 on wall |
| 32 | Cement concrete block 1:2:4 with stone ballast or single |
| 33 | Finishingwallswithexteriordecorative cementbasedpaintsuchassnowcem, robbiacem etc. two or more coats to give aneven shade |
| 34 | Extra for fixing hold fast complete in all respects (LS) |
| 35 | Applying priming coat with metal primer on new steel or iron work incluing preparation of surface and Paintingtwo or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work. |
| 36 | Construction of Foot Path with masonry toe wall & earth filling and Cement Concrete 1:8:16 with 40 mm gauge stone aggregate, 40 mm thick cement concrete topping 1:2:4, inside water works as per DWSS standard Drawing and analysis. |
| 37 | Disinfection Unit: |
| 38 | Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution /sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. ( Milton Roy or Equivalent Make ) |
| 39 | Providing, laying, Fixing, jointing, cutting & testing of uPVC Pipes & Specials (6 kg./cm2) including cost of excavation complete in all respects as per ISI-4985 standard analysis. |
| 40 | Excavation with Manually |
| 41 | uPVC Pipe90 mm o/d |
| 42 | Provision for connecting new pipe line with existing pipe line complete in all respects |
| 43 | Providing & fixing C.I D/F S.V. including cost of tail piece, rubber insertion, gland dori, Nut bolts & accessories complete in all respects. |
| 44 | 80 mm i/d |
| 45 | Consturction of masonary Sluice valve chamber excluding Sluice valve cover as per standard design & drawings of pubic health department. |
| 46 | (a) Size 0.6 m. x 0.6 m. |
| 47 | Dismantling and restoration brick paving complete in all respect as per DWSS standard approved analysis. |
| 48 | Dismantling and restoration Cement Concrete complete in all respect as per DWSS standard approved analysis. |
| 49 | Water Connection on New pipe line |
| 50 | Providing proposed water connection to house hold up to wall with providing laying , jointing, testing MDPE pipe line 15mm o/d 2 mtr & GI 15mm i/d 4.50 mtr, including cost of specials such as tees, bends, sockets, elbow etc, cutting threading and testing in trenches in the ground and ISI marked 15mm i/d GN ferrule as oer IS:2692and 3\"\" i/d clamp with C.I. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete with excavation |
| 51 | Providing proposed water connection to house hold up to wall with providing laying , jointing, testing MDPE pipe line 15mm o/d 2 mtr & GI 15mm i/d 4.50 mtr, including cost of specials such as tees, bends, sockets, elbow etc, cutting threading and testing in trenches in the ground and ISI marked 15mm i/d GN ferrule as oer IS:2692and 3\"\" i/d clamp with C.I. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete with excavation in CC Streets |