Repair Maint Of Certain Summer Appliances And Connected Works At Bairagarh And Repair Maint Of Walk In Cooler Mortuary Body Cabinet And Misc Items At Mh Bhopal Under Ge Bhopal Repair Maint Of Certain Summer Appliances And Connected Works At Bairagarh And , BHOPAL-Madhya Pradesh

Military Engineer Services-MES has published Repair Maint Of Certain Summer Appliances And Connected Works At Bairagarh And Repair Maint Of Walk In Cooler Mortuary Body Cabinet And Misc Items At Mh Bhopal Under Ge Bhopal Repair Maint Of Certain Summer Appliances And Connected Works At Bairagarh And . Submission Date for this Tender is 12-01-2022. Air Conditioner Tenders in BHOPAL Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30304427
Corrigendum : Repair Maint Of Certain Summer Appliances And Connected Works At Bairagarh And Repair Maint Of Walk In Cooler Mortuary Body Cabinet And Misc Items At Mh Bhopal Under Ge Bhopal Repair Maint Of Certain Summer Appliances And Connected Works At Bairagarh And
Open Tender
Indian
Madhya Pradesh
BHOPAL
12-01-2022

Tender Details

Repair Maint Of Certain Summer Appliances And Connected Works At Bairagarh And Repair Maint Of Walk In Cooler Mortuary Body Cabinet And Misc Items At Mh Bhopal Under Ge Bhopal Repair Maint Of Certain Summer Appliances And Connected Works At Bairagarh And Repair Maint Of Walk In Cooler Mortuary Body Cabinet And Misc Items At Mh Bhopal Under Ge Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Jan-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-01-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 64000.0 /-
Tender Value
INR 32 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF CERTAIN SUMMER APPLIANCES AND CONNECTED WORKS AT BAIRAGARH AND REPAIR/MAINT OF WALK IN COOLER, MORTUARY BODY CABINET AND MISC ITEMS AT MH BHOPAL UNDER GE BHOPAL.
Sl. No. Item Description
1NOTE: - This work comprises of (i) Repair/maint of certain Summer appliances at Bairagarh (ii) Repair/maint of Walk in cooler, Mortuary Body cabinates and misc items at MH Bhopal. The qty of individual part shall not vary beyond deviation limit specified in tender.
2M&L for cleaning down complete body including fitting and fixtures of desert cooler of capacity 4000 / 5000 Cum per hours of any makeincluding removal of all sludges, loose paint dust, dirt, etc and preparing the surface for painting and applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank including rewriting of MES No. etc complete all as specified and directed.
3M&L for taking out fan motor single phase 230 Volts, 1400 RPM, 3 speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and fixing in position complete all as specified and directed.
4S&F in repairs front grill / louvers to desert cooler made out from 0.8 mm thick GI sheet suitable for 5000 /4000 Cum / hrs capacity desert cooler of any make complete all as specified and directed.
5S&F in repairs PVC flexible pipe 16 mm outer dia with bends for desert cooler complete with PVC elbow complete all as specified and directed.
6S&F in repairs selector switches three way, 230 Volts single phase of standard quality fixed in desert coolers complete all as specified and directed.
7S&F in repairs wood pad (Set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as specified and directed.
8S&F in repairs desert cooler motor of three speed, ISI marked, 1400 RPM, single phase with ring, side legs, necessary bolts and nuts of capacity 1/8 HP complete all as specified and directed. [Make : Usha/ C&G/ Khaithan or equivalent as approved by GE]
9S&F in repairs plug top three pin 5 Amps complete all as specified and directed. [Make: - ANCHOR / LEADER or equivalent as approved by GE]
10S&F in repairs switch piano type, 240 volts, singe pole, one ways, 5 Amps, fixed in desert coolers complete all as specified and directed.
11S&F in repairs PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including necessary connection fixed in desert coolers complete all as specified and directed.
12S&F in repairs capacitor 4 MFD for fan motor of desert cooler complete all as specified and directed. [Make:-EPCOS / SYSCAP / ASIAN or equivalent as approved by GE]
13S&F body of 22 gauge suitable for coolers of capacity 5000 Cum / hour complete all as specified and directed.
14S&F body of 22 gauge suitable for coolers of capacity 4000 Cum / hour complete all as specified and directed.
15S&F in repairs side shutter (Set of three) made out from 0.80 mm thick galvanised iron sheet suitable for 4000 Cum / hrs capacity desert cooler complete all as specified and directed.
16S&F in repairs side shutter (Set of three) made out from 0.80 mm thick galvanised iron sheet suitable for 5000 Cum / hrs capacity desert cooler complete all as specified and directed.
17S&F in repairs float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15 mm bore iron pipe, weight not less than 142 grams / each complete all as specified and directed. [Make: - PRAYAG/POLYTUFF or equivalent as approved by GE]
18S&F in repairs sumbesable pump 230 Volts, 1/60 HP, ISI Marked for desert cooler including pump support plate fabricated with 0.4 mm thick GI sheet with fixing screws, nuts and bolts complete all as specified and directed. [Make : Khaitan/Polar/GEC or equivalent as approved by GE]
19S&F in repairs iron fan blade powder coated for fan motor of desert cooler 20 inch sweep complete all as specified and directed.
20S&F in repairs cast iron ring of cooler fan motor with clamps suitable for desert cooler complete with nuts & bolts complete all as specified and directed.
21S&F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut/ screws complete all as specified and directed.
22S&F in repairs 15 mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock, complete all as specified and directed. [Make: - PRAYAG/POLYTUFF or equivalent as approved by GE]
23S&F in repairs water tank suitable for desert cooler of cap 5000/4000 cum/hour, fabricated with 1 mm thick mild steel galvanized iron sheet including gas welding at joint and testing for water tightness of apply one coat of red oxide primer complete all as specified and directed.
24M&L for preparation of old painted surface of 40/80 Ltr capacity water cooler, externally and internally including compressor chamber, motor and applying synthetic enamel paint with spray machine including writing MES No. etc. complete all as specified and directed.
25All as per item Ser No. 23.00 above but for water cooler capacity 60/120 Ltrs complete all as specified and directed.
26All as per item Ser No. 23.00 above but for water cooler capacity 150/150 Ltrs complete all as specified and directed.
27M&L for removing the condenser fan motor from water cooler of 40/80 ltrs capacity, rewinding the same with super enameled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed
28All as per item Ser No. 26.00 above but for water cooler capacity 60/120 Ltrs complete all as specified and directed.
29All as per item Ser No. 26.00 above but for water cooler capacity 150/150 Ltrs complete all as specified and directed.
30S&F in repairs Plastic fan blade suitable for water cooler of capacity 40/80 Litres complete all as specified and directed.
31S&F in repairs Plastic fan blade suitable for water cooler of capacity 60 / 120 Ltrs complete all as specified and directed.
32S&F in repairs Plastic fan blade suitable for water cooler of capacity 150/150 Litrs complete all as specified and directed.
33S&F in repairs 15 mm size water tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specified and directed. [MAKE:-JAINKO/GEM/SOMA/ SHAKTI/CORONET or equivalent as approved by GE]
34S&F in repairs starting capacitor 2.5MFD, 80/100 suitable for water cooler of any capacity complete all as specified and directed. [Make:-EPCOS / USHA / ASIAN or equivalent as approved by GE]
35S&F in repairs running capacitor 2.5/10MFD suitable for water cooler of any capacity complete all as specified and directed. [Make:-EPCOS / USHA / ASAIN or equivalent as approved by GE]
36S&F in repairs thermostat suitable for water cooler of any capacity complete all as specified and directed. [Make: Danfoss / Indfoss or equivalent as approved by GE]
37S&F in repairs waste water adaptor PVC, 32 mm size suitable for water cooler of any cpacity complete all as specified and directed.
38S&F in repairs relay with Over Load Protector suitable for 40 to 150 liters capacity water cooler complete all as specified and directed.
39S&F in repairs PVC drain out pipe, heavy duty 32 / 40 mm dia, wall thickness 2 mm complete with fittings such as nipple, clips etc fixed to water coolers of any capacity complete all as specified and directed.
40S&F Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH or equivalent as approved by GE]
41Transporting refrigerator of any make and capacity from MES Store Yard/site to contactor’s workshop for carrying out necessary repair as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations/MES store yard after repairing complete all as specified and directed. NOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.
42M&L for cutting and removing unserviceable freezer unit of refrigerator capacity 165 / 170 / 175 litres of any make, and S&F new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified and directed.
43All as per item Ser No. 41.00 above but for refrigerator capacity 286/300/310 Ltrs complete all as specified and directed.
44M&L for preparation of external old painted surface of refrigerator of capacity 286 / 300 / 310 litres of any make, including denting of minor patches and applying one coat of Duco paint with spray machine including polishing complete all as specified and directed.
45S&F in repairs thermostat suitable for refrigerator 165 to 310 liters capacity complete all as specified and directed. [Make: Danfoss / Indfoss or equivalent as approved by GE]
46M&L in repairs for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section areaand drawing intoand including PVC casing capping, ISI marked, inclusive of all fittings such as tees, bends, junction boxes, etc. 25mm width and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
47Removing the unserviceable compressor sealed unit of any make from water cooler capacity 60 / 120 liters after cutting copper tubing without any damage to existing parts and M&L for replacing compressor with reconditioned compressor of same make with erection of compressor on base with suitable capillary, filter, etc jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing, etc including testing for smooth functioning complete all as specified and directed..
48All as per item Ser No. 46.00 above but for water cooler capacity 40/80 Ltrs complete all as specified and directed.
49All as per item Ser No. 46.00 above but for water cooler capacity 150/150 Ltrs complete all as specified and directed.
50Removing the unserviceable compressor sealed unit of refrigerator of capacity 286 / 300 / 310 liters of any make and M&L for replacing the compressor with reconditioned compressor of same make & model complete, installing in original position with all accessories like relay with Over Load Protector, filter & recharging of refrigerant complete including testing for smooth functioning complete all as specified and directed.
51All as per item Ser No. 49.00 above but for refrigerator capacity 165/175 Ltrs complete all as specified and directed.
52S&F in repairs condensing coil suitable for water cooler of capacity 150 / 150 liters complete all as specified and directed.
53S&F in repairs condensing coil suitable for water cooler of capacity 60 / 120 liters complete all as specified and directed.
54S&F in repairs condensing coil suitable for water cooler of capacity 40 / 80 liters complete all as specified and directed.
55Supply only refrigerant gas R-32 for charging complete all as specified and directed.
56M&L for servicing of Deep freezer of capacity 265 / 320 / 492 ltrs of any make, checking / testing all parts for its serviceability, oiling / greasing of condenser motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level complete including testing for smooth functioning complete all as specified and directed.
57M&L for preparation of external old painted surface of Deep freezer of capacity 405 / 492 liters of any makes including denting of minor patches and applying one coat of Duco paint with spray machine complete all as specified and directed.
58Removing the unserviceable compressor sealed unit of Deep freezer of capacity 320 liters of any make and M&L for replacing the compressor with reconditioned compressor of the same make of model complete re-installing in original position with all accessories like relay with over load protector & recharging of refrigerant complete including testing for smooth functioning complete all as specified and directed.
59S&F in repairs condensing coil suitable for Deep freezer of capacity 320 Liters complete all as specified and directed.
60S&F in repairs single pole and neutral enclosure with two pin and earth,plugand socket, single phase, 240 V with & including 1 No single pole MCB, capacity 20 amps, `C` charactristic, breaking cap 10 KA andindustial plug top complete all as specified and directed. [MAKE:-Legrand (Cat no. 607841) or equivalent in Siemens/ Schinder/L&T/ ABB/Havells]
61S&F in repairs stand made of MS angle of size 60 x 60 x 5 mm by necessary cutting weding and grouting as required at site and applying one coat of red oxide primer below two coats of synthetic enamel paint complete all as specified and directed.
62M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging thegas R-22/R-134 and testing the water cooler complete all as specified and directed.
63All as per item Ser No. 61.00 above but for water cooler capacity 120/80 Ltrs complete all as specified and directed.
64All as per item Ser No. 61.00 above but for water coolercapacity 60/40 Ltrs complete all as specified and directed.
65M&L for finding out the leakage with the pressure test of the condenser or cooling coil ofRerigerator of capacity 300/310 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging thegas R-22/R-134 and testing the water cooler complete all as specified and directed.
66All as per item64.00 above but for refrigerator capacity 165/170/175 Ltrs complete all as specified and directed.
67Removing defective window/Split type air conditioner of any make and capacity from various locations fixed on walls, windows, etc and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site complete all as specified and directed. NOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.
68Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary / new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. Note:- (a)Sealed unit compressor shall be measured and paid separately as supply only (b)If any item required to made equipment functional like capillary tube, copper pipe, etc is deemed to be included in quoted unit rate.
69Taking out window/split type Air conditioner of any make and capacity from position and cleaning the cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner, checking of electrical connections and re-fixing the same at its original position and testing complete all as specified and directed. NOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.
70Taking out package type Air conditioner of any make and capacity 5 Ton from position and cleaning the cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner, checking of electrical connections and re-fixing the same at its original position and testing complete all as specified and directed. NOTE:- (i) Rewinding of bloewer motor, cooling tower motor, etc shall be measuredand paid seperately. (ii) All other spares required for making the plant serviceable shall be deemed to included in the quoted unit rate.
71S&F in replacement power contactor (as per existing) for stater panel board of package type AC complete all as specified and directed. [Make :- L&T/ Legrand/ Seimens/ Schinider or equivalent as approved by GE]
72M&L for rewinding of stator of blower motor of package type AC with super quality of copper wire of existing sizewith varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as specified and directed.
73M&L for rewinding of motor of cooling tower ofpackage type AC with super quality of copper wire of existing sizewith varnishing, backing, testing including painting with one coat of synthetic enameled black paint and complete servicing of the cooling tower complete all as specified and directed.
74Supply only the folowing items for AC complete all as specified and directed. NOTE:- (a) The element of fixing is deemed to be included in respective Schedule ‘A’ Items. (b) If any item is not executed/consumed during the contract period the same shall be taken on ledger charge through Receipt Voucher if Required. (c) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months for all such replacement. If any compressor is burnt during the guaranty period the same shall be replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
75Hermitically sealed / Rotary type compressor of Capacity 1.5 TR complete all as specified and directed. Make: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.
76Hermitically sealed / Rotary type compressor of Capacity 2.0 TR complete all as specified and directed. Make: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.
77FHP motor of capacity 1/5 to 1/18 HP, single phase, 920 RPM with starting and running capacitor suitable for window type AC complete all as specified and directed. Make : AUE/Air master or equivalent as approved by GE.
78Starting capacitor 80-100 MFD /100-120 MFD /120-150 MFD complete all as specified and directed. Make: Keltronor/Epcos as per recommanded by manufacturer or equivalent as approved by GE.
79Running Capacitor 45/50 MFD complete all as specified and directed. Make : EPCOS or as per recommanded by manufacturer or equivalent as approved by GE.
80Starting relay suitable for 1.0 /1.5 /2.0 TR compressor complete all as specified and directed. Make: HI-tech/Classic or as per recommanded by manufacturer or equivalent as approved by GE.
81Rotary/Push type selector switch suitable for 1.5/2.0 TR window type AC complete all as specified and directed.
82Thermostat suitable for window / Split type A/C Make : INDFOSS/Godrej or as per recommanded by manufacturer or equivalent as approved by GE.
83Cover outer of GI Sheet heavy duty with painted for window type AC of capacity 1.5 / 2.0 TR
84Front grill for window type AC of any model all as required at site.Make: LG/ Lancer/ Blue star/ Fedder Lloyed/ Carrier
85Condenser/cooling fan blade suitable for window type AC of any make & capacity.
86Blower fan Motor suitable for split AC of any capacity & make.
87Remote PCB for a split type AC of any capacity & make.
88M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing sizewith varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as specified and directed.
89Charging of refrigerant gas R-22 in window / split type air conditioners 1.5 / 2.0 TR at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed.
90Taking down unserviceable voltage stabilizer of capacity 0.5 KVA to 5 KVAfrom site or MES store and transporting to MES/ contractor workshop to carry out necessary repair as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations after repairing or depositing to MES store yard including testing on load at site complete all as specified and directed. NOTE:- (a) If the transformer is found burnt, the same shall be re-winded in the workshop of contractor as directed. (b) All spares such as relay, PCB, transformeer, etc shall be measured and paid separately as supply only.
91Supply only the folowing items for voltage stablizers complete all as specified and directed. NOTE:- (a) The element of fixing is deemed to be included in respective Schedule ‘A’ Items. (b) If any item is not executed/consumed during the contract period the same shall be taken on ledger charge through Receipt Voucher if Required.
92Main relay 24 Volts, 25 Amps make as per OEM
93Main Control circuit (PCB)
94Output terminal, 32 Amps
95Replacement of Censor Transformer make as per OEM
96Voltmeter make as per OEM
97Time delay 2-3 minutes, low voltage-180 volts AC and high voltage 260-Volt AC make as per OEM
98S&F in repairs single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 2.5 sqmm nominal cross section areacomplete all as specified and directed. [Make: V-MARC/ Plaza/ Havells/Polycab as approved by GE]
99S&F in repairs plug top three pin 15 Amps, 240V complete all as specified and directed. [Make: - ANCHOR / LEADER or equivalent as approved by GE]
100M&L in repairs for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section areaand drawing intoand including PVC casing capping, ISI marked, inclusive of all fittings such as tees, bends, junction boxes, etc. 25mm width and PVC insulated stranded copper conductor of 6 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 4 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
101S&F in replacement sheet metal enclosures with socket plug top and MCB"s with two pin and earth plug and socket complete with one single pole MCB 240 V grade 20 Amp, complete all as specified and directed.
102S&F sheet metal enclosure factory fabricated for Multiphase Out going suitable for Mounting MCCB as Incomer of rating 100 AmpVertical distribution board 4 way with suitable Amp rated bus bar having IP-42 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed. Cat No - DBVDD04160TAB -MCCB of HPL or Equivalent Model Havells/Legrand/ABB as Approved by GE. ( Note : MCCB & MCB Shall be Measured and Paid Separately )
103S&F MCCB 100 Amp, 16 KA 3 Poleincluding complete electricalconnection by appropriate size of copper lugs complete all as specified and directed.
104Repair/maint of UPS for 30 min back up three phase AC input 3 phase, 4 wire voltage range (V AC) 310 to 480 V, 55 HZ, phase out put 3 phase, 4 wire, battery voltage(V DC) 360 V, battery charging current 10A, operating tempeature (celcius) 0 to 45 degree C, operating port RS-232 server and client, IP20 of DSP based double conversion online system with True Galvanised isolation technology with out put power 8000W and out put voltage415 V ± 1% of capacity 7.5 to10. KVAincluding repair of mother board and spare parts if required of suitable make, complete all as specified and directed.
105AMC for Aqua Guard of(quaterly basis) including servicing, repair, renewal/replacement of all filters, defective spare partsif required complete all as specified and directed. .
106Periodical maintenance(Quarterlybasis)of walk in cooler of size 8" x 8" x 8"for preserving life saving medicine and medical stores with maintain temperature range from 2 degree C to 8 degree C, including dual air cooled split type cooling unit of capacity 1 TR/12000 BT U/Hr (one working and other standby)including repair of short circuit/damaged wiring ,Servising of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- 1. Maintenance will be carried through OEM only . 2. Tenderer shall quote the rate including oiling, greasing & minor spare parts as required. 3. Major Spare parts as required to be measured and paid separately.
107Replacement of broken/burnt out spare part (only if required):-
108Repair/Replacement of Compressor for outdoor unit no 1 Modle RUAHOP1514
109Repair/Replacement of PCB Componant
110Repair/Replacement of blower fan heavy duty of size 450mm sweep or as per site requirement
111Periodical maintenance(Quarterlybasis)of walk in cooler of size 15" x 12" x 10"for preserving vegetable/meat stores with maintain temperature range from 2 degree C to 8 degree C, including dual air cooled split type cooling unit of capacity 5 TR/60000 BT U/Hr (one working and other standby)including repair of short circuit/damaged wiring ,Servicing of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- 1. Maintenance will be carried through OEM only . 2. Tenderer shall quote the rate including oiling, greasing & minor spare parts as required. 3. Major Spare parts as required to be measured and paid separately.
112Replacement of broken/burnt out spare part (only if required):-
113Repair/Replacement of Compressor for outdoor unit no 1 Model RUAHO6024CS
114Repair/Replacement of PCB Componant
115Repair/Replacement of blower fan heavy duty of size 650mm sweep or as per site requirement.
116Periodical maintenance(Quarterlybasis)of Mortuary cabinate for two body, 230 volt single phase, 50 hz with roof mounted refrigeration system of cp 6000 BTU/H, temperature range from 2 degree C to 6 degree C , complete with 1 piece stainless steel tray with handle including repair of short circuit/damaged wiring, Servising of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- 1. Maintenance will be carried through OEM only . 2. Tenderer shuold quote the rate including oiling,greasing & minor spare parts as required. 3. Major Spare parts as required to be measured and paid separately.
117Repair/Replacement of Air Curtain with adjustable louvers with electric motor single phase 230 volts AC, 50 hz with maximum velocity 10-11 Amps (1000mm width). Air speed 20M/S of Make Cecon modle No C1-042 including repair of short circuit/damaged wiring,servicing, repair/replaement of single phase motor complete all as specified and directed.
118Taking out old U/S voltage stabilizers of capacity 0.5 KVA to 5 KVAfrom MES store/site and repair the same in MES work shop (if the transformer found burnt, the in same shall be re-winded in the workshop of contractor complete all as specified and directed.
119Taking out old burnt winding work and re-winded with super enameled copper winding wire (existing size) for 5 KVA voltage stabilizers including all necessary insulating material and testing complete all as specified and directed.
120All as per item Ser No.93 above but capacity of voltage stabilizer 4 KVA/3KVA, complete all as specified and directed.
121All as per item Ser No. 93 above but capacity of voltage stabilizer 2 KVA / 1KVA, complete all as specified and directed.
122Charging of refrigerant gas R-134a for deep freezer /refrigerator/water cooler at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed.
123Deduct schedule of credit (calculation will be done off line)Rs. 81,757.00
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail