| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.(Group-B) |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (Make-Polycab/Havells/Grandlay)3 x 1.5 sq. mm |
| 3 | 3 x 4 sq. mm |
| 4 | 3 x 6 sq. mm |
| 5 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make-Northwest)1 or 2 Module (75mmX75mm) |
| 6 | 3 Module (100mmX75mm) |
| 7 | 4 Module (125mmX75mm) |
| 8 | 6 Module (200mmX75mm) |
| 9 | 8 Module (125mmX125mm) |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (Make-Northwest)5/6 A switch |
| 11 | 2 way 5/6 A switch |
| 12 | 15/16 A switch |
| 13 | 3 pin 5/6 A socket outlet |
| 14 | 6 pin 15/16 A socket outlet |
| 15 | Telephone socket outlet |
| 16 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.(Make-Havells/Schnider/Seimens/Legrand/ABB) |
| 17 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make-Havells/Seimens/Legrand/ABB/Schnider)8 way (4 + 24), Double door |
| 18 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Havells/Schnider/Seimens/Legrand/ABB)Single pole |
| 19 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make-Havells/Schnider/Seimens/Legrand/ABB)63 A |
| 20 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Havells/Schnider/Seimens/Legrand/ABB)63 A |
| 21 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required(Make-Polycab/Havells/Grandlay)2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 22 | Less for credit buy back of old burnt out/faulty accessoriesAssorted size PVC insulated copper conductor cable |
| 23 | Assorted size modules, GI box alongwith modular base & cover plate |
| 24 | Assorted size/type switch socket/telephone socket |
| 25 | Assorted size MCB |
| 26 | 63A Isolator |
| 27 | 63ARCCB |
| 28 | 8 way (4 + 24), Double door DB |
| 29 | submain wiring alongwith earth wire (2 X 16 sq. mm + 1 X 6 sq. mm earth wire) |