}

Bids Are Invited For Table Top High Speed Refrigerated Centrifuge ( Preferred Make : Eppendorf, Thermo Fisher, Sorvall ) - Maximum Speed Of 30, 130Xg / 17500 Rpm, With A Brushless Motorspeed Setting Should Be Possible In Both Rpm And Rcfrotor ( S ) -Jammu And Kashmir

Higher Education Commission has published Bids Are Invited For Table Top High Speed Refrigerated Centrifuge ( Preferred Make : Eppendorf, Thermo Fisher, Sorvall ) - Maximum Speed Of 30, 130Xg / 17500 Rpm, With A Brushless Motorspeed Setting Should Be Possible In Both Rpm And Rcfrotor ( S ) . Submission Date for this Tender is 07-01-2022. Cutting Crimping and Punching Tools Tenders in Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30299096
Corrigendum : Bids Are Invited For Table Top High Speed Refrigerated Centrifuge ( Preferred Make : Eppendorf, Thermo Fisher, Sorvall ) - Maximum Speed Of 30, 130Xg / 17500 Rpm, With A Brushless Motorspeed Setting Should Be Possible In Both Rpm And Rcfrotor ( S )
Open Tender
NCB
Jammu And Kashmir
07-01-2022

Tender Details

Bids Are Invited For Table Top High Speed Refrigerated Centrifuge ( Preferred Make : Eppendorf, Thermo Fisher, Sorvall ) - Maximum Speed Of 30, 130Xg / 17500 Rpm, With A Brushless Motorspeed Setting Should Be Possible In Both Rpm And Rcfrotor ( S ) To Be Supplied With Centrifuge Should Have Minimum24x1.5Ml / 2Ml It Should Be Possible To Store 50 Programs With 5 Quick Access Program Keysshould Possess A Separate Short Spin Key For Brief Spinrotor Lids Should Have A Quick Lock-System For Secure Lid Closing And Opening Noise Levels Should Be ?54 Db ( A ) It Should Be Possible To Operate The Centrifuge At Set Rpm, For Short Spin Protocolstimer: 15 Sec To 59 Min Or Moreinstrument Should Be Ce Certified, Ivd Conformity , Elisa Reader And Shakerpreferred Make : Thermo Fisher, Biotek, Biorad, Genetix, Transasia ) - 800Ts: 6- To 96-Well Plates, 400 To 750 Nm Detection, Shakingdetection Modes: Absorbance Read Methods: End Point. Kinetic, Well Area Scanning ( Under Computer Control ) Microplate Types: 6- To 384-Well Plates Temperature Control: To 50 °C ( “I” Configuration ) Shaking: Yes ( Except 800Tsnb ) Read Speed: 11 Secs / 96 Wells ( Sweep Mode ) Software: Gen5 Reader Control Software Gen5 Microplate Reader And Imager Software ( Optional ) Absorbance Light Source: Tungsten Halogen Wavelength Selection: Filters Wavelength Range: 400 – 750 Nm 340 – 750 Nm ( “Uv” Confirgurations ) Dynamic Range: 0 To 4.0 Od ( Normal And Rapid Read Modes ) 0 To 3.0 Od ( Sweep Read Mode ) Resolution: 0.001 Od ( Standalone Mode ) 0.0001 Od ( Via Gen5 Control ) Filter Wheel Capacity: 5 Positions Filters Supplied: 405, 450, 490, 630 340, 405, 450, 490, 630 ( “Uv” Configurations ) Features: • Versatile For Many Applications, Including Elisa, Protein And Other End Point Assays, Plus Kinetics And Cell-Based Assays Color Touchscreen For Quick Programming And Simple Operation • Usb Flash Drive For Convenient Data Export, Gen5 Import For Analysis • High Precision And Accuracy For Reliable Results • Durable And High Quality Design From Biotek, The #1 Microplate Reader Brand , Haematology Analyser ( Fully Automated 5 Part Differential Cell Counter ) ( Preferred Make: Syxmax, Mindray Transasia ) - Please See The Specifications Given For The Said Item In The Pdf Format In The Uploaded Specification File , Biochemistry Analyser ( Preferred Make: Accurex, Mindray Transasia ) - Please See The Specifications Given For The Said Item In The Pdf Format In The Uploaded Specification File , Urine Strip Reader ( Preferred Make : Accurex, Roche, Clinitek - Semi-Quantitative Reflectance Photometeroptional Unit: Leds And Colour Detectorwavelength: 470, 540, 650 Nmincubation Period: 55Secscapacity: 60 Strips Per Hour In Standard Mode Or 240 Strips Per Hour ® With In Smart Timing Modetouchscreen Color Tft Lcd Display ( 320 X 240 Pixels. Built-In Printerhost Interface Rs232, Usb Possibility To Connect External Keyboard Or A Barcode Scanner Via Ps / 2Memory Capacity: Last 400 Results , Dry Block Heaterspreferred Make : Genetix, Tarsons, Eppendorf - Accurate Temperature Control From Ambient+5ºc To 150ºc In 0.1ºc Incrementsintegral Aluminium / Stainless Steel Block To Hold 12 X 1.5-2 Ml Tubestemperature Increments: 0.1°Ctimer: 0 - 19 Hours 59 Minutes Or Continuouselectrical : 100 - 240V / 50-60 Hz , Spinix Vortex. ( Preferred Make : Tarsons, Genetix And Thermo Fisher, Himedia, Agilent ) - Vortex Should Have Speed Control Vortex Should Have Spare Cup Attachment Vortex Should Have Spare One Hand Attachment Vortex Should Have Spare Microtube Insert. , Fine Analytical Balancepreferred Make : Mettler Toledo, Contech, Wenser - • Minimum Display- 0.1Mg• Readibility 0.1 Mg• Repeatibility 0.1 Mg• Linearity 0.2 Mg• Max Capacity <130 Gm• Operating Ambient Temperature 10-40 C• Response Time : 3 Sec , Rocky Max Rocking Shake ( Preferred Make Tarsons, Genetix And Thermo Fisher, Himedia, Agilent ) - Speed Should Be Around 10-50 Rpmtime Can Withhold Speed 99 Minutes And 99 Hrplatform Dimension 30 L X 30 B In ( Cm ) Manimum Load 20 Kgdigital Displayloadac, 230V, 50 Hz , Rechargeable And Motorisedpipette Controller Preferred Make : Gilson, Eppendorf, Thermo Fisher - Range- 1Ml To 100Ml.Aspiration / Dispensing Speed Setting Should Be Settableselectable Flow Ratelithium-Ion Battery ( Rechargeable ) Should Be Supplied With Appropriate Stand And Adapters Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 30-12-2021 07-01-2022

Key Value

Document Fees
Refer document
EMD
INR 75000.0 /-
Tender Value
INR 25 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail