Comprehensive Repair / Maintenance Of Security Lights, Garden Lights And Allied Works At Ts Mahul And Sewri Under Ge ( Nw ) Mankhurd Comprehensive Repair / Maintenance Of Security Lights, Garden Lights And Allied Works At Ts Mahul And Sewri Under Ge , GE (NW) MANKHURD-Maharashtra

Department Of Planning Statistics And Evaluation- has published Comprehensive Repair / Maintenance Of Security Lights, Garden Lights And Allied Works At Ts Mahul And Sewri Under Ge ( Nw ) Mankhurd Comprehensive Repair / Maintenance Of Security Lights, Garden Lights And Allied Works At Ts Mahul And Sewri Under Ge . Submission Date for this Tender is 03-01-2022. Tube Light Tenders in GE (NW) MANKHURD Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

30291484
Corrigendum : Comprehensive Repair / Maintenance Of Security Lights, Garden Lights And Allied Works At Ts Mahul And Sewri Under Ge ( Nw ) Mankhurd Comprehensive Repair / Maintenance Of Security Lights, Garden Lights And Allied Works At Ts Mahul And Sewri Under Ge
Open Tender
Indian
Maharashtra
GE (NW) MANKHURD
03-01-2022

Tender Details

Comprehensive Repair / Maintenance Of Security Lights, Garden Lights And Allied Works At Ts Mahul And Sewri Under Ge ( Nw ) Mankhurd Comprehensive Repair / Maintenance Of Security Lights, Garden Lights And Allied Works At Ts Mahul And Sewri Under Ge ( Nw ) Mankhurd

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Dec-2021 AMENDMENT Other 27-12-2021
2 27-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-01-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 52000.0 /-
Tender Value
INR 26 Lakhs /-

BOQ Items

Name of Work : COMPREHENSIVE REPAIR/MAINTENANCE OF SECURITY LIGHTS, GARDEN LIGHTS AND ALLIED WORKS AT TS MAHUL & SEWRI UNDER GE (NW) MANKHURD
Sl. No. Item Description
1Notes : (i)The contractor should be in possession of valid electrical license to execute electrical works. (ii) Supervisor for execution of electrical works/ electrical component of works employed by the contractor shall possesses supervisor certificate of competency issued by concerned State Government/ Union Territory and the worker/ tradesmen for execution of electrical works/ electrical component of works shall hold necessary permit issued by concerned State Government/ Union Territory. Excavation in trenches not exc. 1.5 mtr wide and not exc.1.50 mtr depth for foundation etc or for shafts, wells, cesspits, manholes etc n.exc 10 Sqm on plan & n.exc 1.5 mtr in depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable cable protection cover for re-use at site obtained during excavation complete all as specified and directed.
2All as per ser item No 01 above but depth exc 1.5 m upto 3.0 m etc complete all as specified and directed.
3Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil etc complete all as specified and directed.
4Removing the excavated materials not exc 50mtr and depositingwhere directed at a level not exceeding 1.5 mtr above the staring point etc complete all as specified and directed.
5M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection etc complete all as specified and directed. Note : Sand after punning down will be measured
6Supply and laying precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm laid in trenches etc complete all as specified and directed. Make - Methab Indore Tiles or Conforming to IS Marked.
7Laying only un-reinforced precast concrete cable cover class LV, type-I, flate size 250mm x 150mm x 40mm laid cable cover obtained from item Ser No 8.00 to 12.00 shall be reused etc complete all as specified and directed.
8Taking out old unserviceable underground cable XLPE insulated, PVC sheathed armored heavy duty aluminum conductor LT 1100 Volts grade of size 4 Core 10 Sqmm, fixed on pole, wall and laid in trenches etc after disconnecting etc complete all as specified and directed. Note - Excavation and earth work will be mesured and paid seprately.
9All as per item No 8.00 abovebut of size 4 core 16 Sqmmetc complete all as specified and directed.
10All as per item No 8.00 above but of size 3.5 core 25 Sqmm etc complete all as specified and directed.
11All as per item No 8.00 abovebut of size 3.5 core 95 Sqmm etc complete all as specified and directed.
12All as per item No 8.00 abovebut of size 3.5 core 240 Sqmm etc complete all as specified and directed.
13Supply and laycableXLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm x 4 core etc complete all as specified and directed.
14All as per item No 13.00 abovebut of size 4 core 16 Sqmm etc complete all as specified and directed.
15All as per item No 13.00 abovebut of size 3.5 core 25 Sqmmetc complete all as specified and directed.
16All as per item No 13.00 abovebut of size 3.5 core 70 Sqmm etc complete all as specified and directed.
17All as per item No 13.00 here-in-before but of size 3.5 core 95 Sqmm etc complete all as specified and directed.
18All as per item No 13.00 here-in-before but of size 3.5 core 240 Sqmm etc complete all as specified and directed.
19M&L for straight through joint suitable for 3 ½ / 4 core up to 95 Sqmm size underground cable etc complete all as specified and directed.
20M&L for straight through joint suitable for 3 ½ /4 core 95 to 240 Sqmm size underground cable etc complete all as specified and directed.
21M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole etc complete all as specified and directed.
22M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole etc complete all as specified and directed.
23S& F in replacement of GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x 5mm flat iron, nuts , bolts, etc complete all as specified and directed.
24M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil etc complete all as specified and directed.
25S&F of HDPE pipe 75 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etc complete all as specified and directed.
26Supply and fix in replacement ofFRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channelincluding making connections etc complete all as specified and directed. Make - confirm to Cat No KF 1616 G of Hensel/ National / Sintex.
27M&L for taking down old unsv and supply & lay 3Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts,all For interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc complete all as specified and directed. Make :- POLYCAB /Havells or equivalent.
28M&L for Multistandarded Copper Conductor cable of3 Core 1.5 Sq mmsize drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc taking down old unsv cable etc complete all as specified and directed. Make :- POLYCAB /Havells or equivalent.
29M&L in repairs MCCBs 3 Pole 250 Amps,36 KA including connecting up electrically with proper lugsglands etc complete all as specified and directed.
30M&L in repairs MCCBs 3 Pole 200 Amps,36 KA including connecting up electrically with proper lugsglands etc complete all as specified and directed.
31M&L in repairs MCCBs 3 Pole 100 Amps,16 KA including connecting up electrically with proper lugsglands etc complete all as specified and directed.
32M&L in repairs MCBs FP 16 amp to 63 Amps,16 KA including connecting up electrically with proper lugsglands etc complete all as specified and directed.
33Supply and fix 3 pole power contactor 32 A , coil voltage 230 V etc complete all as specified and directed.
34M&Lin repairs for 24 Hrs240 V FM1 Quartz type daily timer switch for controlling street lights contactors etc complete all as specified and directed. Make : L & T/ Indo Asian
35Dismentling of PCC foundation / coping from pole not exc 1.65below ground level for removing of pole etc complete all as specified and directed.
36M&L for pcc 1:2:4 type B-1 using 20 mm graded stone agrregates as in pedestal of pole/ strut and in copping including necessary form work and finishing exposed faces of concrete even and smooth using extra cement etc complete all as specified and directed.
37Supply and fix in replacement 8 Watt LED Bollard garden light fitting with efficient high output COB LED, pressue die cast powder coated housing with PC diffuser driver nut bolt ,washer base plate foundation 0.3mtrx0.3 mtr x.03 mtr by PCC 1:2:4 type B-1 using 20mm grade stone aggegates of size including excavtion and earth work , provision of GI bend of size 50MM dia in the PCC for cable entry the fitting shall cvonform to cat No-CONEBL8WLED830PSYMTOPC of Havells equivalent from Philips, Bajaj / CG.
38Suply and fix New generation , post-top LED light 15W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 50MM dia in the PCC for cable entry the fittingwith nut bolts,washer shall conform to cat No-CORALMINIPT15WLED757PSYMTOPC of Havells equivalent from Philips, Bajaj/CG.
39Suply and fix New generation , post-top LED light 15W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 50MM dia in the PCC for cable entry the fittingwith nut bolts,washer shall conform to cat No-CORALMINIPT15WLED830PSYMTOPC of Havells equivalent from Philips, Bajaj/CG.
40Suply and fix New generation , post-top for 360 degree indirect lights with IP 65 protection LED light 40W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light fittingwith nut bolts,washer shall conform to cat No-LPTO-40-CDL-4 of Crompton equivalent from Philips, Bajaj/CG.
41S & F in replacement of security light fitting/Building security lightLED type 60 watts with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc all as directed by Engineer in charge Cat no -SZPSLMM060 of Shakti or equivalent Bajaj/Philips/CG.
42S&F in Repairs 36 W LED recessed full lit lminaire with glare free niform illumination with longer life and less maintainance 2x2 fitting mounted direct/indirect architectural luminaire including connecting 1.5 Sqmm white colour suitable for false ceiling fixing arrangement etc complete all as specified and directed. The fitting shall conform to cat No SZRSRMX036 of Shakti or equivalent Philips/ Crompton.
43M&L for locating of faults of LT UG cable PILCA/XLPE upto 400 sqmm sized by using comutrised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing etc complete all as specified and directed. Note:- (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately. (ii) Cable joint will be measured and paid seperetely. (iii) Additional lenth of cable required at site for jointing will be measured and paid seperately.
44Supply install, test and commissioning of Powder coated LTFeeder panel cubical indoor type Channel mounted compartmentalized in construction allConfirming to IS 8623 Part 1 1993CPRI approved factory as per CA fabricatedmade out of 2 mm thick CRCA sheet & suitable size to accomodateall accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, ContactorsThe TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. Thecubicle shallhaveabottomchannel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm of A detachable predrilled gland plateof thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 Sqmm Wireand consisting the following, including taking down of old unsv panel after disconnecting Existing cables, Existing energy meters and re fixing the energy meters at new panel & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts. Location P-168 (Sandesh) & P-169 (Tarang) Family qtrs at Mahul (a) Copper bus bar 100 Amps for 3 phase and Neutral (b) MCCB FP 63 Amps 415 Volt25 KA - 1 Nos (Incommer) (c) MCB TPN 40 Amps, 16 KA 415 Volts- 1 Nos (d) MCB SPN 40 Amps, 10 KA 230 Volts - 7 Nos (e) Digital Ameter -01 No, (f) Digital Volt Meter - 01 No (g) Space for Fixing 7 Nos of Single Phase Energy Meter of Capacity 40 Amps, (h) RYB Indicators - 1 Set (j) Selector switch for voltmeter and Ammeter.- 01 nos.
45-ditto all as per item No 44 here-in-before but with the following acessories:- Location P-167 (Vidyut) at Mahul a) Copper bus bar 100 Amps for 3 phase and Neutral b) MCCB FP 63 Amps 415 Volt25 KA - 1 Nos (incommer) c) MCB TPN 40 Amps, 25 KA 415 Volts- 1 Nos d) MCB SPN 40 Amps, 10 KA 230 Volts - 5 Nos e) Digital Ameter -01 No,f) Digital Volt Meter - 01 No f) Space for Fixing 05 Nos of Single Phase Energy Meter of Capacity 40 Amps, g) RYB Indicators - 1 Set j) Selector switch for voltmeter and Ammeter.- 01 nos.
46All as per Item No 44.00 here-in-beforebut with the following acessories:- Location P-22 Family qtrs at NSD Sewari (a) Copper bus bar 100 Amps for 3 phase and Neutral (b) MCCB FP 63 Amps 415 Volt25 KA - 1 Nos (Incommer) (c) MCB TPN 40 Amps, 25 KA 415 Volts- 2 Nos (d) MCB SPN 40 Amps, 10 KA 230 Volts - 9 Nos (e) Digital Ameter -01 No, (f) Digital Volt Meter - 01 No (g) Space for Fixing 9 Nos of Single Phase Energy Meter of Capacity 40 Amps, (h) RYB Indicators - 1 Set (j) Selector switch for voltmeter and Ammeter.- 01 No.
47All as per item No 44 here-in-beforebut with the following acessories:- Location P-21 Family Qtrs at NSD Sewari (a) Copper bus bar 100 Amps for 3 phase and Neutral (b) MCCB FP 40 Amps 415 Volt25 KA - 1 Nos (Incommer) (c) MCB TPN 40 Amps, 25 KA 415 Volts- 1 Nos (d) MCB SPN 40 Amps, 10 KA 230 Volts - 5 Nos (e) Digital Ameter -01 No, (f) Digital Volt Meter - 01 No (g) Space for Fixing 5 Nos of Single Phase Energy Meter of Capacity 40 Amps, (h) RYB Indicators - 1 Set (j) Selector switch for voltmeter and Ammeter.- 01 No.
48Supply install, test and commissioning of Powder coated LTFeeder panel cubical outdoor type (double door openable) Channel mounted compartmentalized in construction allConfirming to IS 8623 Part 1 1993CPRI approved factory as per CA fabricatedmade out of 3 mm thick CRCA sheet & suitable size to accomodateall accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, ContactorsThe TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. Thecubicle shallhaveabottomchannel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm of A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 Sqmm Wireand consisting the following, including taking down of old unsv panel after disconnecting Existing cables, Existing energy meters and re fixing the energy meters at new panel & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts.: Location : Near Pota Cabin at Mahul (a) Copper bus bar 600 Amps for 3 phase and Neutral (b) MCCB FP 400 Amps 415 Volt25 KA - 1 Nos (Incommer) (c) MCB TPN 40 Amps, 16 KA 415 Volts- 3 Nos (d) MCB SPN 40 Amps, 10 KA 230 Volts - 2 Nos (e) Digital Ameter -01 No, (f) Digital Volt Meter - 01 No (g) RYB Indicators - 1 Set (h) Selector switch for voltmeter and Ammeter.- 01 nos and Timer. (j) Timer switches 415 V three phase of 20 Amps rating with contactor-2 No"s
49All as per item No 48 here-in-before but with the following acessories:- Location Near Flamingo Post at Mahul (a) Copper bus bar 100 Amps for 3 phase and Neutral (b) MCCB FP 63 Amps 415 Volt25 KA - 1 Nos (Incommer) (c) MCB TPN 40 Amps, 16 KA 415 Volts- 2 Nos (d) MCB SPN 32 Amps, 10 KA 230 Volts - 2 Nos (e) Digital Ameter -01 No, (f) Digital Volt Meter - 01 No (g) RYB Indicators - 1 Set (h) Selector switch for voltmeter and Ammeter.- 01 Nos and Timer. (j) Timer switches 415 V three phase of 20 Amps rating with contactor-2 No"s
50Supply, install and testing, commissioning feeder piller box outdoor type, IP-54 protection CPRI approved, factory fabricated, cubical panel wall mounted, self supported, free standing type, made out of 3mm thick CRCA sheet with locking arragement, suitable for 3 phase, 4 wire, 415 volt, 50HZ, AC supply including suitable size copper conductor control wiring and powder coating with connecting the cables with necessary cable glands, lugs etc proper arrangement for veritilation complete with and including the following accessories :- Location: NSD Sewri (i) Copper bus bar Phases & Neutral for 200 Amps- 01 set (a) MCCB 4 pole 25 KA 100A - 1 Nos (Incommer) (b) MCB TPN 40 Amp 10 KA- 02 Nos (c) MCB SPN 32 Ampc 10 KA - 02 Nos (d) Digital Volt Meter - 01 No (e) RYB Indicators - 1 Set (f) Selector switch for voltmeter and Ammeter.- 01 Nos and Timer.
51M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deepbelow ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
52Comprehensive AMC of three phase 60 KVA UPS 3 phase,including servising/replacement of worn out parts like PCB, IGBT based, Diode, Capacitors,relay,cooling fan,indicators,connectors,lugs,wires,switches,fuses andto attending all brakdown calls and check all electronic component/cards,checking of rectifier/inverter logic boards,adjust battery charging current,cheking of auto transfer facility between inverter and bypass & bypass to UPS, verification/setting/ rectification of LCD mimics alarms,indications, UPS &battery changover test. Location: RUKMANI Bldg Mahul
53Comprehensive AMC of 30 KVA 3 phase,415 V Servo voltage stabilizer (6 Nos) including replacing of all components releted with AVR following:- (a) I.C. Electronic control card (b) Control Transformer (c) R.C. Network (d) Main big gear (e) Toggle switch (f) Indication Lamp (g) Voltmeter (h) A.C. synchronous Motor (j)Dimmer stopper all as specified and directed by Engineer –in –Charge.Note: (i) The rate quoted shall be inclusive transportation,material and labour,including all defective spare makeas per existing,complete. (ii) Attending of fault within 8 hours of intimation to avoid disruption of service to user technical requirement.Delay of attending of fault by more than 01 day wound invite penalty charge of 1000/hr.
54Supply and fix in repairs Power Capacitors of Rating 100 KVAR 415 Voltin repairs Naturally air cooled Double dielectric heavy duty, MPP type440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR with merer system conforming to IS 13340 and 13341 ISI Marked etc complete all as specified and directed.
55All as per item No 54.00 above but Power Capacitors of Rating 50 KVAR 415 Volt etc complete all as specified and directed.
56All as per item No 54.00 above but Power Capacitors of Rating 25 KVAR 415 Volt etc complete all as specified and directed.
57All as per item No 54.00 above but Power Capacitors of Rating 10 KVAR 415 Volt etc complete all as specified and directed.
58All as per item No 54.00 above but Power Capacitors of Rating 5 KVAR 415 Volt etc complete all as specified and directed.
59M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc complete all as specified and directed.
60M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
61M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work etc complete all as specified and directed.
62Dismantling of old UNSV/rusted steel tubular poles 6 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site etc complete all as specified and directed.
63Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130 mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point etc complete all as specified and directed.
64M&L for reinforced cement concretenominal mix M-20(using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, etc complete all as specified and directed. Note - Reinforcement and form work will be measured and paid separately).
65M & L for TMT bars of Fe-500 D grade conforming to is:1786, 12 mm dia & over, including cutting to length, bent to shape equired, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
66M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 8 mm dia bars as in binders, spacers, strippusincluding cutting to length, bent to shape required, cranking, bending spirallyfor hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
67M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, etc complete all as specified and directed. Note : A sum of Rs 41,900.00 towards sch of credit shall be deducated to arrive the contract sum