Repair Maint Of Transformers, Lt Panels, Feeder Pillar Boxes, Apfc Panels Etc. In Cantt Area And 119 Ta Bn Under Ge Shillong. Repair Maint Of Transformers, Lt Panels, Feeder Pillar Boxes, Apfc Panels Etc. In Cantt Area And 119 Ta Bn Under Ge Shillon, GE SHILLONG-Meghalaya

Military Engineer Services-MES has published Repair Maint Of Transformers, Lt Panels, Feeder Pillar Boxes, Apfc Panels Etc. In Cantt Area And 119 Ta Bn Under Ge Shillong. Repair Maint Of Transformers, Lt Panels, Feeder Pillar Boxes, Apfc Panels Etc. In Cantt Area And 119 Ta Bn Under Ge Shillon. Submission Date for this Tender is 27-12-2021. Feeder Pillar Tenders in GE SHILLONG Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

30290690
Corrigendum : Repair Maint Of Transformers, Lt Panels, Feeder Pillar Boxes, Apfc Panels Etc. In Cantt Area And 119 Ta Bn Under Ge Shillong. Repair Maint Of Transformers, Lt Panels, Feeder Pillar Boxes, Apfc Panels Etc. In Cantt Area And 119 Ta Bn Under Ge Shillon
Open Tender
Indian
Meghalaya
GE SHILLONG
27-12-2021

Tender Details

Repair Maint Of Transformers, Lt Panels, Feeder Pillar Boxes, Apfc Panels Etc. In Cantt Area And 119 Ta Bn Under Ge Shillong. Repair Maint Of Transformers, Lt Panels, Feeder Pillar Boxes, Apfc Panels Etc. In Cantt Area And 119 Ta Bn Under Ge Shillong.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 62000.0 /-
Tender Value
INR 31 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF EXTERNAL WATER SUPPLY CI/GI/PPR PIPELINES, VALVES AND WATER SUPPLY PUMP SETS, STARTERS, PANEL BOARDS, IRON REMOVAL PLANTS, BORE WELLS ETC AT ARC, GTC AND 11WEU UNDER GE SHILLONG.
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5mdeep getting out in soft/ loosesoil complete all as specified and asdirected by Engr in Charge.
2M&L for cuttingin any type of road/ hardstanding/ Footpath etc. for laying GI Pipeand making good to disturbed surfaces withPCC, type B-1, (1:2:4, using 20mm graded stone aggregates) includingnecessary formwork etccomplete all as specified and as directed by Engr-in-Charge.
3Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick as in soft/loose soil etc complete all as specified and directed.
4Removing excavated materials (soil) to a distancen.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and asdirected.
5Taking up or down old serviceable/ unserviceable withconnectionsincluding cleaning for refixing or removal from sitewith all fittings complete all as specified and directed. of following bore(s) of pipe:-. 100mm bore Note:excavation will be measured and paid separately under relevant items
6All as per item no. 5.00 here in above but of80mm bore complete all as specified and as directed.
7All as per item no. 5.00 here in above but of 50mm bore complete all as specified and as directed.
8All as per item no. 5.00 here in above but of 40mm bore complete all as specified and as directed.
9All as per item no. 5.00 here in above but of 25mm bore complete all as specified and as directed.
10All as per item no. 5.00 here in above but of 20mm bore complete all as specified and as directed.
11Re-laying only old serviceable pipes and connection in trenches, including fittings such as tee, bend, nipple, socket, reducer, union etcincluding testing complete all as directed by Engr in Charge of following bore(s)of pipe:- 100mm bore pipe Note: (a) Excavation will be measured and paid separately under relevant item . (b) GI Pipes obtained after taking down against srl item no. 5.00, 5.01, 5.02, 5.03, 5.04 and 5.05 shall be used under this item.
12All as per item no. 6.00 here in above but of80mm bore complete all as specified and as directed.
13All as per item no. 6.00 here in above but of 50mm bore complete all as specified and as directed.
14All as per item no. 6.00 here in above but of 40mm bore complete all as specified and as directed.
15All as per item no. 6.00 here in above but of 25mm bore complete all as specified and as directed.
16All as per item no. 6.00 here in above but of 20mm bore complete all as specified and as directed.
17Supply, laying and connection in trenches GI tubing,mediumgrade,including with new fittings such as tee, bend, nipple, socket, reducer, union etc complete all as directed by Engr in Chargeof following bore (s) of pipe: 100mm bore pipe Note- Excavation will be measured and paid separately under relevant items.
18All as per item no. 7.00 here in above but of 80mm bore pipe
19All as per item no. 7.00 here in above but of 50mm bore pipe
20All as per item no. 7.00 here in above but of 40mm bore pipe
21All as per item no. 7.00 here in above but of 25mm bore pipe
22All as per item no. 7.00 here in above but of 20mm bore pipe
23S&F3 layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply incl all PP-R plain & brass threaded polypropylene randonfittingssuch as male/female threaded socket, male/female threaded tee, reducers, union, socket end cap, plug etc., laid in trenches/ wall/ floor incl connection from water main GI/ PPR pipe incl taking down old unserviceable pipe of following sizes. 75mm bore pipe. Note: Excavation will be measured and paid seperately under relevant item.
24All as per item no. 8.00 here in above but of 50mm bore complete all as specified and as directed.
25All as per item no. 8.00 here in above but of 40mm bore complete all as specified and as directed.
26All as per item no. 8.00 here in above but of 25mm bore complete all as specified and as directed.
27Supply and fix in repair CI Sluice valve with flanged ends as per IS-14846PN 1.6, heavy duty including stainless steel spindle and wheel, ISI marked with nut bolts and jointing material i.e. rubber gasket including testing complete all as specified and directed by Engr-in-charge of following bores:- 80 mm bore pipe
28(b) All as per item no. 9.00 here in above but of100 mm bore
29(c) All as per item no. 9.00 here in above but of150 mm bore
30(d) All as per item no. 9.00 here in above but of200 mm bore
31(d) All as per item no. 9.00 here in above but of250 mm bore
32S&F CI non return valve, 250mm bore dia with by pass arrangement working pressure 10kg/cm2 conforming to IS 5312 including jointing by means of rubber gasket 3mm thick MS nuts bolts & washer etc including taking down old unserviceable non return valve complete all as specified and directed by Engr-in-charge. Make: Zoloto/ Kirlosker/ Upadhaya
33M&L for flange joint with new flange (set of two flange) and rubber gasket, nuts, bolts washer of required size and white lead complete all as directed by Engr-in-charge for the following bore of pipe: 80mm bore pipe NOTE: Excavation if any will measured and paid seperately under appropriate items here-in-above.
34All as per item no. 11.00 here in above but of100mm bore
35All as per item no. 11.00 here in above but of150mm bore
36All as per item no. 11.00 here in above but of200mm bore
37S&F Gun metal gate valve classI (ISI) marked with iron wheel head, screwed both ends for iron pipe, suitable for following bore of pipe including taking down old existing unserviceable gate valve complete all as specified and directed by Engr-in-charge. 50mm bore pipe
38All as per item no. 12.00 here in above but of40mm bore
39All as per item no. 12.00 here in above but of25mm bore
40All as per item no. 12.00 here in above but of20mm bore
41Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed by Engr-in-charge. 80mm bore pipe.
42All as per item no. 13.00 here in above but of100mm bore
43All as per item no. 13.00 here in above but of150mm bore
44Laying only and connection in ternches CI pipes (including all fittings), with spigot and socket ends, medium grade, class B including fittings such as tee, bend, nipple, socket, reducer, flange, union etc complete all as directed by Engr-in-charge for the following size of pipe: 80mm bore pipe NOTE: Excavation will be measured and paid seperately under appropriate items here-in-above.
45All as per item no. 14.00 here in above but of100mm bore
46All as per item no. 14.00 here in above but of150mm bore
47M&L for CI pipes with spigot and socket ends centrifugal cast, class B including fittings laid in trenches or floor complete all as directed by Engr-in-charge for the following size of pipe: 80mm bore pipe
48All as per item no. 15.00 here in above but of100mm bore
49All as per item no. 15.00 here in above but of150mm bore
50M&L for lead joint run suitable for spigot and socket pipes including spun yarn complete all as directed by Engr-in-charge for the following size of pipe: 300mm bore pipe
51All as per item no. 16.00 here in above but of250mm bore
52All as per item no. 16.00 here in above but of200mm bore
53All as per item no. 16.00 here in above but of150mm bore
54All as per item no. 16.00 here in above but of100mm bore
55All as per item no. 16.00 here in above but of80mm bore
56M&L for cast iron fitting such as Bends(any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable upto 150mm bore including taking out old unserviceable CI fitting.
57S&F PP-R Gate Valves (brass insert) as per requirement of the site suitable for following bore of pipe including taking down old existing unserviceable gate valve complete all as specified and directed. 50mm bore pipe.
58All as per item no. 18.00 here in above but of25mm bore pipe
59All as per item no. 18.00 here in above but of20mm bore pipe
60M&L for construction of VALVE PIT TYPE "A" of OF PCC BLOCK MASONARY and ofsize 900 mm x 900 mm x 900 mm (internal dimension) , with all fittings and fixtures complete all as specified and shown in Drg No. TD/EM/6 Sheet 1/2 including dismantling old unserviceable one.
61M&L for construction of VALVE PIT TYPE "A" of OF PCC BLOCK MASONARY and ofsize 600 mm x 600 mm x 900 mm (internal dimension) , with all fittings and fixtures complete all as specified and shown in Drg No. TD/EM/6 Sheet 1/2 including dismantling old unserviceable one.
62Supplying, fabricating & fixing structural mild steel channel, angle, iron, sheets and brackets etc for fabrications of valve chamber cover, chasis for pump, PS tank plates, PS tank covers, clamps and back plates including nuts, bolts and washers, welding, bending cold or hot, drilling holes for insulators bolts, in any shape or size as indicated or directed and including applying of two coats of Aluminium paint over one coat of red oxide primer complete, all as specified and directed.
63M&L for painting on external surfaces of CI/GI pipes, valves, pit covers, pumps applying of two coats of black synthetic enamel paint including preperation of surfaces complete, all as specified and directed by Engr-in-charge.
64M&L for PCC 1:3:6 type C2 (Using 40 mm graded stone aggregate) for making good disturbed surface of channels/ pavements/ footpaths/ roads/ foundation etc complete, all as specified and directed.
65M& L for cast iron piecessuitable upto 150 mm boreand Connecting pieces one end flangedandother socket or spigot and bell mouth pieces oneend flanged other end taperingas bell mouth including taking out old unserviceble CI fitting etc complete all as specified and as directed by Engineer in charge.
66M& L for cast iron fitting such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs , flanged ends , suitable upto 150 mm boreandincluding taking out old unserviceble CI fitting etc complete all as specified and as directed by Engineer in charge.
67M& L for cast iron fitting such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs , flanged ends ,suitable for 200 mm to 300 mm boreandincluding taking out old unserviceble CI fitting etc complete all as specified and as directed by Engineer in charge.
68M&L for fabrication andnecessarylath work for making check nutmade out of mild steel iron suitable for 80/100 mm dia CI sluice valve etc including dismantling old unserviceable one etccompleteall as specified and directed by Engr-in-charge.
69All as per item no. 26.00 here in above but of150 mm dia sluice valve.
70All as per item no.26.00 here in above but of200/300 mm dia sluice valve.
71M&L for fabrication andnecessarylath work for making Spindlemade out of mild steel iron suitable for 80/100 mm dia CI sluice valve etc including dismantling old unserviceable one etccompleteall as specified and directed by Engr-in-charge.
72All as per item no. 27.00 here in above but of150 mm dia sluice valve.
73All as per item no. 27.00 here in above but of200/300 mm dia sluice valve.
74M&L forplain cement concrete type B-1 (1:2:4) , using 20 mm graded crushed stone aggregate as in coping / benching including weathering,slightly rounded or chamfered angles and throating,etc including necessary formwork complete all as specified and as directed.
75M&L for PCC type D-2 (1:4:8 , using 40 mm graded crushed stone aggregate etc as in foundation, filling and mass concreteetc including necessary formwork complete all as specified and as directed.
76M&L for rendering 15 mm thick cement plaster in neat cement sand mortar 1:4 on fair faces of brick work or on concrete surfaces, finished fair and even without using extra cement etccomplete all as specified and as directed.
77S&F in repairRotational moulded HDPEpolyethylene 500 ltrs capacity water storage tanks three layered, (ISI marked) (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball valves 20mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball including 20mm dia GI medium grade over flow pipe, approx lenght 1.5 mtr, 25 mm dia wash out pipe with pluged at one end complete all as specified and directed.
78S&F in repair rotational moulded polyethylene 1000 ltrs capacity water storage tanks , three layered, (ISI marked) (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball valves 20mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball including 20mm dia GI medium grade over flow pipe, approx lenght 1.5 mtr, 25 mm dia wash out pipe with pluged at one end complete all as specified and directed.
79S&F in repair 15mm ball valve, high pressure of PTMT, with epoxy coated aluminium rod and high density plasic ball screwd for iron pipe (min wt 15mm-142 gms) complete, screwed for iron pipe complete all as specified and as directed.
80S&F in repair 20mm ball valve, high pressure of PTMT, with epoxy coated aluminium rod and high density plasic ball screwd for iron pipe (min wt 20mm-210 gms) complete, screwed for iron pipe complete all as specified and as directed.
81S&F in repair 25mm ball valve, high pressure of PTMT, with epoxy coated aluminium rod and high density plasic ball screwd for iron pipe (min wt 25mm-455 gms) complete, screwed for iron pipe all as specified and directed
82S&F in repair PVC lid (cover) suitable for water tank of capacity (500/1000 ltrs) all as specified and directed
83S&F in repair PVC nipple of size 20mm dia bore suitable for HDPE water storage tank etc complete all as specified and as directed.
84S&F in repair PVC nipple of size 25mm dia bore suitable for HDPE water storage tank etc complete all as specified and as directed.
85S&F CI foot valve conforming to IS-4038 of pipe size 250mm dia including taking out old unserviceable foot valve from the sump complete all as specified and as directed. Make: Upadhaya/ Zoloto/ Kirloskar
86S&F CI foot valve conforming to IS-4038 of pipe size 100mm dia including taking out old unserviceable foot valve from the sump complete all as specified and as directed. Make: Upadhaya/ Zoloto/ Kirloskar
87Taking out carefully submersible pump set 7.5/5 HP from 300 to 340 feet deep well after disconnecting all incoming and outgoing electric and water pipeline connection and keep the all pipe and cable in safe custody for reuse at same work for lowering the submersible pump set complete all as specified and as directed by Engr-in-charge. NOTE: (i) Before lowering the pump all flanges must be proper welding. (ii) The repairs part of pump and motor will be measured and seperately. (iii)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. (iv) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (v) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Induction motor required to be repair / replaced under the subject work.
88Motor rewinding of submersible pump 7.5HP including replacement of bush/bearing, check nuts, connector complete all as specified and as directed. NOTE: (i)Unserviceable removed winding wire shall be theproperty of contractor through schedule of credit and cost of same shall deemed to be included in the rate quoted. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work.
89Motor rewinding of submersible pump 5.0HP including replacement of bush/bearing, check nuts, connector complete all as specified and as directed. NOTE: (i)Unserviceable removed winding wire shall be theproperty of contractor through schedule of credit and cost of same shall deemed to be included in the rate quoted. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work.
90Pump repair/ overhaulingincluding replacement of Bush, bearing, impeller of capacity 7.5 HP complete all as specified and directed. Note : (i)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. Cost of Bush, bearing, impeller and replacement of same shall deemed to be included in the unit rate quoted against this item. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (iii) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of thePump Set required to be repair / replaced under the subject work.
91Pump repair/ overhaulingincluding replacement of Bush, bearing, impeller of capacity 5.0 HP complete all as specified and directed. Note : (i)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted.Cost of Bush, bearing, impeller and replacement of same shall deemed to be included in the unit rate quoted against this item. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (iii) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of thePump Set required to be repair / replaced under the subject work.
92S&F stay wire rope steel, 10SQMM including taking down old unserviceable wire complete all as directed by Engr-in-charge.
93S&F copper cable 3 core flat suitable for submersible pump set 10SQMM including taking down old unserviceable complete all as directed by Engr-in-charge. Make: HAVELLS/ FINOLEX/RR KABEL LTD
94S&F supporting clamps made of MS Flat iron 6mm thick and 65mm width suitable for up to 50mm bore pipe including taking down old unserviceable complete all as directed by Engr-in-charge.
95S&F Bore Cover suitable for 200mm dia pipe including taking down old unserviceable complete all as directed by Engr-in-charge.
96S&F GI tubing 65mm dia medium grade including taking down old unserviceable complete all as directed by Engr-in-charge.
97S&F Adaptor including taking down old unserviceable complete all as directed by Engr-in-charge.
98S&F in repair star Delta starter 7.5HP complete inclusive all incoming and outgoing electric connection and testing complete all as specified and as directed by Engr-in-charge.
99S&F in repair star Delta starter 5.0HP complete inclusive all incoming and outgoing electric connection and testing complete all as specified and as directed by Engr-in-charge.
100Taking out old burnt 100/90HP induction motor 415 volts, 3 phase after disconnecting all incoming and outgoing electric connection, foundation bolts, decoupling from pump & transporting to workshop, dismantling it completely, removing the burnt out winding then rewinding same size super enamelled copper wire & replace all defective parts such as bearing etc and fixing on same position including testing complete all as specified and as directed by Engr-in-charge Note : (i) Burnt out removed winding wire shall be theproperty of contractor through schedule of credit and cost of same shall deemed to be included in the rate quoted. (ii)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. (iii) Cost of all defective parts such as Bearing etc. and replacement shall be deemed to be included in the rate quoted (iv) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (v) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Induction motor required to be repair / replaced under the subject work.
101Taking out the old worn out 100/90HP pump set after disconnecting all incoming and outgoing electric connection, 150mm bore CI pipe connection including 150mm non return valve, sluice valve, bend, foundation bolts, decoupling from electric motor & transporting to workshop, dismantling it completely, dismantling it completely, replacing all the parts wear and teared such as bearing, impeller, pump shaft etc and fixing on same position including testing complete all as specified and as directed by Engr-in-charge. NOTE: (i)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. Cost of bearing, impeller, pump shaft and replacement of same shall deemed to be included in the unit rate quoted against this item. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (iii) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Pump Set required to be repair / replaced under the subject work.
102Taking out old burnt 40HP induction motor 415 volts, 3 phase after disconnecting all incoming and outgoing electric connection, foundation bolts, decoupling from pump & transporting to workshop, dismantling it completely, removing the burnt out winding then rewinding same size super enamelled copper wire & replace all defective parts such as bearing etc and fixing on same position including testing complete all as specified and as directed by Engr-in-charge Note : (i)Burnt out removed winding wire shall be theproperty of contractor through schedule of credit and cost of same shall deemed to be included in the rate quoted. (ii) Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. (iii)Cost of all defective parts such as Bearing etc. and replacement shall be deemed to be included in the rate quoted (iv)Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (v) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Induction motor required to be repair / replaced under the subject work.
103Taking out the old worn out 40HP pump set after disconnecting all incoming and outgoing electric connection, 100mm bore CI pipe connection including 100mm non return valve, sluice valve, bend, foundation bolts, decoupling from electric motor & transporting to workshop, dismantling it completely, dismantling it completely, replacing all the parts wear and teared such as bearing, impeller, pump shaft etc and fixing on same position including testing complete all as specified and as directed by Engr-in-charge. NOTE: (i)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. Cost of bearing, impeller, pump shaft and replacement of same shall deemed to be included in the unit rate quoted against this item. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (iii) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Pump Set required to be repair / replaced under the subject work.
104Taking out old burnt 05HP induction motor of any make 415 volts, 3 phase after disconnecting all incoming and outgoing electric connection, foundation bolts, decoupling from pump & transporting to workshop, dismantling it completely, removing the burnt out winding then rewinding same size super enamelled copper wire of existing gauge & replace all unserviceable parts such as bearing with necessary insulating material, varnishing, backing etc and reassembling the serviceable motor completely and fixing on position as directed including testing complete all as specified and as directed by Engr-in-charge. Note : (i) Burnt out removed winding wire shall be theproperty of contractor through schedule of credit and cost of same shall deemed to be included in the rate quoted. (ii)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. (iii) Cost of all defective parts such as Bearing etc. and replacement shall be deemed to be included in the rate quoted (iv) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (v) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Induction motor required to be repair / replaced under the subject work.
105Taking out old burnt 7.5HP induction motor of any make 415 volts, 3 phase after disconnecting all incoming and outgoing electric connection, foundation bolts, decoupling from pump & transporting to workshop, dismantling it completely, removing the burnt out winding then rewinding same size super enamelled copper wire of existing gauge & replace all unserviceable parts such as bearing with necessary insulating material, varnishing, backing etc and reassembling the serviceable motor completely and fixing on position as directed including testing complete all as specified and as directed by Engr-in-charge. Note : (i) Burnt out removed winding wire shall be theproperty of contractor through schedule of credit and cost of same shall deemed to be included in the rate quoted. (ii)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. (iii) Cost of all defective parts such as Bearing etc. and replacement shall be deemed to be included in the rate quoted (iv) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (v) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Induction motor required to be repair / replaced under the subject work.
106Repair and Maintenance of 100/90HP Pump Set for replacing Bearing, Bush, Gland Packing, Connector, Rubber Coupling Bush etc. complete all as specified and directed by Engr-in-charge. NOTE: (i)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. Bearing, Gland Packing, Rubber Coupling Bushshall be measured and paid separately as "Supply " only items and labour element involves for replacement of same shall deemed to be included in the unit rate quoted against this item. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (iii) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Pump Set required to be repair / replaced under the subject work.
107Supply only Ball Bearing with bearing number 6309 complete all as specified and Directed. Make: TATA/ SKF/ NBC
108Supply only Ball Bearing with bearing number 7309complete all as specified and Directed. Make: TATA/ SKF/ NBC
109Supply only Gland Packing 20mm Heavy Duty complete all as specified and Directed.
110Supply only Rubber Coupling bush complete all as specified and Directed.
111Repair and maintenance of 40/25 HP Pump Set for replacing replacing Bearing, Rubber Coupling Bush etc. complete all as specified and directed by Engr-in-charge. Note : (i)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. Bearing, Rubber coupling bush shall be measured and paid separately as "Supply " only items and labour element involves for replacement of same shall deemed to be included in the unit rate quoted against this item. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (iii) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Pump Set required to be repair / replaced under the subject work.
112Supply only Ball Bearing with bearing number 6307 complete all as specified and Directed. Make: TATA/ SKF/ NBC
113Supply only Rubber Coupling bush complete all as specified and Directed.
114Repair and Maintenance of 100/90HP Electric Motor three phase for replacing Bearing, connector etc. complete all as specified and directed by Engr-in-charge. Note : (i)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. Bearing,shall be measured and paid separately as "Supply " only items and labour element involves for replacement of same shall deemed to be included in the unit rate quoted against this item. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (iii) A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Electric motor required to be repair / replaced under the subject work.
115Supply only Ball Bearing with bearing number 6312 complete all as specified and Directed. Make: TATA/ SKF/ NBC
116Supply only Ball Bearing with bearing number 6314 complete all as specified and Directed. Make: TATA/ SKF/ NBC
117Supply only Ball Bearing with bearing number 6316 complete all as specified and Directed. Make: TATA/ SKF/ NBC
118Repair and Maintenance of 40/25HP Electric Motor three phase for replacing Bearing, connector etc. complete all as specified and directed by Engr-in-charge. Note : (i) Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. (ii)Cost of all defective parts such as Bearing etc. and replacement shall be deemed to be included in the rate quoted (iii)Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work. (iv)A Board of Officers shall be conveyed by the Accepting Officer to ascertain the defective parts of the Electric motor required to be repair / replaced under the subject work.
119Supply only Ball Bearing with bearing number 6304 complete all as specified and Directed. Make: TATA/ SKF/ NBC
120Supply only Ball Bearing with bearing number 4064 complete all as specified and Directed. Make: TATA/ SKF/ NBC
121Supply and replace MS coupling suitable for 100/90HP pump set any make complete all as specified and directed by Engr-in-charge.
122Taking out the old 90HP pump set after disconnecting all incoming and outgoing electric and water supply connection, including non return valve, sluice valve, bend, foundation bolts, decoupling from electric motor & transporting to MES Store. Demolition of existing foundation with the help of power hammer Drill machine and construct new foundation, place as directed, foundation size as per existing, including grouting of foundation bolt and nut to fix the pump in position, testing and installation of the pump complete, all as specified and as directed by Engr-in-charge. Note : (i)Cost of minor spare parts such as nuts, bolts and washer replaced shall deemed to be included in the rate quoted. (ii) Work shall be carried out by authorised agent of manufacturer of motor and written approval of the same shall be obtained from AcceptingOfficers before execution of the work.
123Supply and fixing or laying 100mm bore Galvanised steel tubing, Light grade for routing LT & underground Cable including all fittings such as elbow, bend, socket, socket reducer, tee etc., complete,at different locations as specified and directed by Engr-in-charge. MAKE:Jindal/ Tata/ Prakash.
124Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable withstranded aluminumconductor 1100 volt grade of size 240Sqmm 3.5 Core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing including taking down old unserviceable one etc complete all as specified and as directed.
125Supply and laying HRFR PVC insulated cable withmulti stranded copper conductor 1100 volt grade of size 50Sqmm single Core fixed with necessary fixing arrangements such as cable lugs, nuts, bolts etc. maintaining colour code, connecting and testing including taking down old unserviceable one etc complete all as specified and as directed.
126M&L forEarthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than1.5 m below normal ground level connected to galvanised earth strip 25 X 4 mm as earth lead by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I including taking down old unserviceable earthing plate with accessories. Note: GI strip upto 7.5 m length shall be deemed to be included in the quoted rate against ibid item. The quantity required over 7.50 m shall be measured andpaid under relevant items seperately.
127Supply & fixing, testing & commissioning of CPRI approved factory made indoor type, LT panel board of size 1500X1460X650mm, 2mm thick CRCA Sheet, mounting channel, chemically treated, powder coated suitable size of treated insulated compartment, dust and vermin proof, free standing complete with 450Amps aluminum insulated bus bar, incoming and outgoingChangeover/MCCB"s, MCB"s, over load relay, single phase preventer & 100 HP FASD starter complete, overallcompartment frontdoor with locking arrangement, air vent min 2 Nos, internal copper wiring,excavation and PCC work, all incoming & outgoing cable connection etc., with the following accesories complete all as specified and as directed by Engr-in-charge. (a) Bus bar with aluminium strip 3 phase & neutral, 450 Amps-01 Set. (b) Incoming MCCB 400 Amps, 4 pole. Make: Havells- 01 No (c) Outgoing MCCB 160 Amps, 35 kA, 4 pole. Make: Havells-2 Nos (d) Ameter 0~200 Amps- 1 set. (e) Voltmeter 0~500 volts- 1set. (f)100HP starter Set complete- 1 set. (g) Selector switch three stage-2 set. (h) Lamp indicator set of three RYB- 3 set. Note: Bidder quoted rate shall be inclusive of S&F of the components from (a) to (h) alongwith feeder pillar box.
128Supply and fix in repairMotor terminal suitable for 100/90HP Motor including necessary electrical connection complete as specified and directed by Engr-in- Charge.
129Supply and fix in repairMotor terminal suitable for 40/25HP Motor including necessary electrical connection complete as specified and directed by Engr-in- Charge.
130Supply and fix in repair Bushing suitable for 100/90HP Motor including necessary electrical connection complete as specified and directed by Engr-in- Charge.
131Supply and fix in repair Bushing suitable for 7.5/5.0HP Motor including necessary electrical connection complete as specified and directed by Engr-in- Charge.
132Supply and fix in repair gland plate including full threaded nut & bolt for pump capacities 100/90HP complete as specified and directed by Engr-in- Charge.
133Supply and fix in repair gland plate including full threaded nut & bolt for pump capacities 7.5/5.0HP complete as specified and directed by Engr-in- Charge.
134Supply and fix in repair gland packing of suitable size made of asbestos grip with silicon etc complete all as specified and directed by Engr-in- Charge.
135M&L for preperation of old deteriorated surfaces of iron and applying after making good surface one coat of red-oxide primer two coat of synthetic enamel paint complete all as specified and directed by Engr-in-charge.
136S&F in repairs four pole 415 volts, 80Amps contactor for 40HP motor starter complete all as specfied and as directed. Make: Havells/ L&T/ BCH.
137S&F in repairs thermal over load relay (Auto/ manual reset) relay range 66 ~110Amps for motor starter all as directed. Make: BCH/ L&T/ Legrand
138S&F in repairs thermal over load relay (Auto/ manual reset) relay range 22~30Amps for motor starter all as directed. Make: BCH/ L&T/ Legrand
139S&F in repairs thermal over load relay (Auto/ manual reset) relay range 48~70Amps for motor starter all as directed. Make: BCH/ L&T/ Legrand
140Supply and fix Single phase preventor electronic type with tripping system against single phase & phase reversal suitable for protection of electric motor 3 phase 415 volt AC 50Hz complete all as specified and directed including taking down old unserviceable one complete all as specified and as directed.
141S&F MCCB, 4 pole, 415 volts, 200Amps, 36kA breaking capacity with thermal and magnetic release including taking down old unserviceable one as specified and direction. Make: Havells/ L&T/ Legrand
142S&F MCCB, 4 pole, 415 volts, 160Amps, 25kA breaking capacity with thermal and magnetic release including taking down old unserviceable one as specified and direction. Make: Havells/ L&T/ Legrand
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail