| 1 | Maintenance cum preventive maintenance of UPS cum voltage regulator02 X Nos of 60 KVA 415 Volts 50 Hz ( Make : LIEBERT). Servicing will be carried out by and through authorised Service Engineer of M/S LIEBERT UPS India Pvt Ltd on quarterly basis and equipment testing certificate will be provided by AuthorisedService Engineer after servicing. The equipment will be checked / inspected during any time for detecting and rectifying the fault during the period of 11 (Eleven) month, complete all as specified and to the entire satisfaction of Engineer-in-Charge.NOTE: Unit rate quoted is deemed inclusive of following operations/ services during the quarterly servicing. (a) Proper cleaning of the equipment (b) Visual inspection of the UPS.(c) Checking of all re-set, and where necessary relevant present adjustment.(d)Rectification of any apparent fault, where immediately possible and recording of other for rectification in later stages. |
| 2 | (e) Taking of electrical measurement to establish the operational status of UPS.(f) Checking /setting of adjustable device.(g) Visual inspection of UPS batteries.(h) Checking for correct and accurate operation of all instruments.(j) Record of total voltage of battery under float condition.(k) Checking of each battery voltage once.(l) Cost of all spares required to provided except wound component AC/DC capacitor, fan and batteries.(m) Cheacking and installationof Software and hardware program if necessory with proper authorised dealer of Socomec UPS company, rate of software and hardware included in above job rate. |
| 3 | Maintenance cum preventive maintenance of UPS cum voltage regulator80 KVA 415 Volt 50 Hz ( Make : LIEBERT). Servicing will be carried out by and through authorised Service Engineer of M/S LIEBERT UPS India Pvt Ltd on quarterly basis and equipment testing certificate will be provided by AuthorisedService Engineer after servicing. The equipment will be checked / inspected during any time for detecting and rectifying the fault during the period of 11 (Eleven) month, complete all as specified and to the entire satisfaction of Engineer-in-Charge.NOTE: Unit rate quoted is deemed inclusive of following operations/ services during the quarterly servicing. (a) Proper cleaning of the equipment (b) Visual inspection of the UPS.(c) Checking of all re-set, and where necessary relevant present adjustment.(d)Rectification of any apparent fault, where immediately possible and recording of other for rectification in later stages. |
| 4 | (e) Taking of electrical measurement to establish the operational status of UPS.(f) Checking /setting of adjustable device.(g) Visual inspection of UPS batteries.(h) Checking for correct and accurate operation of all instruments.(j) Record of total voltage of battery under float condition.(k) Checking of each battery voltage once.(l) Cost of all spares required to provided except wound component AC/DC capacitor, fan and batteries.(m) Cheacking and installationof Software and hardware program if necessory with proper authorised dealer of Socomec UPS company, rate of software and hardware included in above job rate. |
| 5 | Maintenance cum preventive maintenance of UPS cum voltage regulator20 KVA 415 Volts 50 Hz ( Make : LIEBERT). Servicing will be carried out by and through authorised Service Engineer of M/S LIEBERT UPS India Pvt Ltd on quarterly basis and equipment testing certificate will be provided by AuthorisedService Engineer after servicing. The equipment will be checked / inspected during any time for detecting and rectifying the fault during the period of 11 (Eleven) month, complete all as specified and to the entire satisfaction of Engineer-in-Charge.NOTE: Unit rate quoted is deemed inclusive of following operations/ services during the quarterly servicing. (a) Proper cleaning of the equipment (b) Visual inspection of the UPS.(c) Checking of all re-set, and where necessary relevant present adjustment.(d)Rectification of any apparent fault, where immediately possible and recording of other for rectification in later stages. |
| 6 | (e) Taking of electrical measurement to establish the operational status of UPS.(f) Checking /setting of adjustable device.(g) Visual inspection of UPS batteries.(h) Checking for correct and accurate operation of all instruments.(j) Record of total voltage of battery under float condition.(k) Checking of each battery voltage once.(l) Cost of all spares required to provided except wound component AC/DC capacitor, fan and batteries.(m) Cheacking and installationof Software and hardware program if necessory with proper authorised dealer of Socomec UPS company, rate of software and hardware included in above job rate. |
| 7 | Supply and fixing, in replacement, of Communication interface board (CIB board) of 60 KVA UPS and replacing the board of proper make of existing in site with complete connection of existing cables with and CIB board making upsrunning condition complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge.Make :As approved by GE. |
| 8 | Supply and fixing, in replacement, of Communication interface board (CIB board) of 80 KVA UPS and replacing the board of proper make of existing in site with complete connection of existing cables with and CIB board makeing upsrunning condition complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge.Make :As approved by GE. |
| 9 | Supply and fixing, in replacement, of Communication interface board (CIB board) of 20 KVA UPS and replacing the board of proper make of existing in site with complete connection of existing cables with and CIB board makeing upsrunning condition complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge.Make :As approved by GE. |
| 10 | Supply and fixing, in replacement, of Monitoring unit Board and programing flashing of 60 KVA ups , proper coy make existing at sitewith complete connection through authorisedoperator of company to the entire satisfaction of Engineer-in-Charge. Make : As approved by GE. |
| 11 | Supply and fixing, in replacement, of Monitoring unit Board and programing flashing of 20 KVA ups ,Proper coy make existing at sitewith complete connection through authorisedoperator of company to the entire satisfaction of Engineer-in-Charge.Make : As approved by GE. |
| 12 | Supply and fixing, in replacement, of Monitoring unit Board and programing flashing of 80 KVA ups ,Proper coy make existing at sitewith complete connection through authorisedoperator of company to the entire satisfaction of Engineer-in-Charge. Make : As approved by GE. |
| 13 | Supply and fixing, in replacement,charger board of 80 KVA UPS existing in site complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge.Make : LIEBERT/ As approved by GE. |
| 14 | Supply and fixing, in replacement, charger board of 60 KVA UPS existing in site complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge.Make : LIEBERT/ As approved by GE. |
| 15 | Supply and fixing, in replacement, charger board of 20 KVA UPS existing in site complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge.Make : LIEBERT/ As approved by GE. |
| 16 | Supply and fixing, in replacement, old unserviceableSMF type sealed lead acid battery12 volt 200 AH of existing make/model conecting each other, with suitable size ofcopper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and as directed.Make : Exide /Amron/Microtek |
| 17 | Supply and fixing, in replacement, old unserviceableSMF typesealed lead acid battery12 volt 100 AH of existing make/model conecting each other, with suitable size ofcopper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and as directed.Make : Exide /Amron/Microtek |
| 18 | Supply and fixing, in replacement, old unserviceableSMF typesealed lead acid battery12 volt 65 AH of existing make/model conecting each other, with suitable size ofcopper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and as directed.Make : Exide /Amron/Microtek |
| 19 | Supply and fixing, in replacement, IGBT board rectifier capacity 80 KVA UPS including internal hardware and software and making connection to the system for smooth functioning of UPS after taking out old broken cabinet complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge.Make : EMERSION/ As approved by GE. |
| 20 | Supply and fixing, in replacement, metal cabinet (IP-20 or above protection) of capacity 80 KVA UPS including internal hardware and software and making connection to the system for smooth functioning of UPS after taking out old broken cabinet complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge. |
| 21 | Supply and fixing, in replacement, metal cabinet(IP-20 or above protection) of capacity 60KVA UPSincluding internal hardware and software and making connection to the system for smooth functioning of UPS after taking out old broken cabinet complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge. |
| 22 | Supply and fixing, in replacement, metal cabinet(IP-20 or above protection)of capacity 20KVA UPS including internal hardware and software and making connection to the system for smooth functioning of UPS after taking out old broken cabinet complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge. |
| 23 | Servicing of OT lights (03 Nos), Model : Dr Med 5030Make : Dr Medby the authorized service engineer of Dr Medcompany, any time to attend the break down /service of OT lightincluding taking down of OT lights, clean and align all parts, proper fitting and removing /scrubbing of rust to ensure free movement of dome (up-down/ left to right), proper connection of wiring from UPS to OT lights complete all as specified and as directed by and to the entire satisfaction of Engineer-in-Charge.Note: (i)Contractorwill concludeAMC with OEM andacopyof agreement will be submitted to Engr - In- Chargeand GE before commencement ofAMC. No payment willbe madetocontractor withoutsubmissionof validAMC. |
| 24 | Servicing of OT lights ( 06 Nos), Model: Dr Med 5030Make : Dentis lewis by the authorized service engineer of Dr Medcompany, any time to attend the break down /service of OT lightincluding taking down of OT lights, clean and align all parts, proper fitting and removing /scrubbing of rust to ensure free movement of dome (up-down/ left to right), proper connection of wiring from UPS to OT lights complete all as specified and as directed by Engineer-in-charge. Note: (i)Contractorwill concludeAMC with OEM andacopyof agreement will be submitted to Engr -in-Chargeand GE before commencement ofAMC, no payment willbe madetocontractor withoutsubmissionof validAMC. |
| 25 | Supply & fixing, in replacement, ofhead controllerPCBofOT Lights ofDr Med , complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDr Med LED5030 . |
| 26 | Supply & fixing, in replacement, of arm controller PCBofOT Lights ofDr Med , complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDr Med LED5030 . |
| 27 | Supply & fixing, in replacement, of SMPS input harnessSMPS output harness ofOT Lights ofDr Med , complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDr Med LED5030 . |
| 28 | Supply & fixing, in replacement, of main PCB bracket 2ofOT Lights ofDr Med , complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDr Med LED5030 . |
| 29 | Supply & fixing, in replacement, of damperboltOT Lights ofDr Med , complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDr Med LED5030 . |
| 30 | Replacement of Handle shaft assy ofOT Lights ofDr Med , complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDr Med LED5030 . |
| 31 | Supply & fixing, in replacement, ofhead controllerPCBofOT Lights ofDentis lewis, complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDentis lewis LED5030 . |
| 32 | Supply & fixing, in replacement, of arm controller PCBofOT Lights ofDentis lewis, complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDr Med LED5030 . |
| 33 | Replacement of SMPS input harnessSMPS output harness ofOT Lights ofDentis lewis, complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDentis lewisLED5030 . |
| 34 | Supply & fixing, in replacement, of main PCB bracket 2ofOT Lights ofDentis lewis, complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDentis lewis LED5030 . |
| 35 | Supply & fixing, in replacement, of damperboltOT Lights ofDentis lewis, complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDentis lewisLED5030 . |
| 36 | Replacement of Handle shaft assy ofOT Lights ofDentis lewis, complete allas specified and directed by and to the entire satisfaction of Engineer-in-Charge. ModelDentis lewisLED5030 . |