Indian Oil Corporation Limited-IOCL has published Supply, Installation, Testing And Commissioning Of Tank Farm Instruments Like Radargauges Antenna, Aops, Mstw, Hcds, Hooters, Push Buttons And Dyke Valve Sensors For Tank Conversion From Sko To Ms And Auto Biodiesel Blending Facilities At Hu. Submission Date for this Tender is 29-12-2021. Valve Tenders in Hubli Depot, Karnataka Karnataka. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 21-Dec-2021 | Date Corrigendum | Date | 27-12-2021 |
2 | 27-Dec-2021 | Date corrigendum | Date | 29-12-2021 |
Sl. No. | Item Description |
1 | SUPPLY COMPONENTS |
2 | Supply of array type antenna with flange for existing RTG to be mounted on 6" still well along with mounting accessories complete as per specification, tender document and site requirement. |
3 | Supply of multi point temperature averagingsensorwith integrated water interface probe (MSTW) along with mounting accessories etc with minimum 8 elements temperature sensor (for above ground tanks - MS) complete as per specification and tender document. |
4 | Supply of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc For Vertical Product tanks complete as per specification and tender document |
5 | Supply of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon vapour detectors along with calibration kit, accessories and structural supports, canopy/sunshade etc as per specification and tender document. |
6 | Supply of Point type Infrared detector |
7 | Supply of Open path type Infrared detector (0-90m) along with alignment telescope, configuration & testing kit etc |
8 | Supply of Hooter Cum Beacon with reset push button along with mounting Accessories etc complete as per specification and tender document. |
9 | Procuring of dyke valve sensors |
10 | Note: Supply of cables shall be along with accessories like certified double compression cable glands with PVC shrouds, plugs for excessentries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners,conduits, structural steel for mounting of equipments, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules,etc |
11 | Supply of FRLS Armoured Copper Power cable as per tender specifications. |
12 | 4C x 4 sqmm |
13 | Supply of FRLS Armoured Copper Signal cable as per tender specifications. |
14 | 6P x 1.5 sqmm |
15 | Supply of FRLS Armoured Cu Control cable |
16 | 6C x 1.5sqmm |
17 | 24C x 1.5sqmm |
18 | 36C x 1.5 sqmm |
19 | Supply of FS Armoured Copper Signal cable as per tender specifications. |
20 | 2P x 1.5sqmm |
21 | Supply of FS Armoured Copper Control cable as per tender specifications. |
22 | 12C x 1.5 sqmm |
23 | 2C x 1.5 sqmm |
24 | Supply of 1C x 6 Sq. mm FRLS Flexible copper insulated green wirefor earthinginstruments and junction boxes etc complete as per specification and tender document |
25 | Supply of GI strip ( 50mm X 6mm) |
26 | Supply of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents.100mm |
27 | 50mm |
28 | 100mm |
29 | 200mm |
30 | Supply of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excessentries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners.Complete as perspecification / tender documents. -12 way JB |
31 | Supply of Exd/FLP Local Push button Station with Indicating Lamp for ROSOV |
32 | Supply of Exd/FLP Local Push button Station with Indicating Lamp for DBBV |
33 | Supply of Exd/FLP Local Push button Station with Indicating Lamp for MOV |
34 | Supply of Barrier for DO |
35 | SERVICE COMPONENTS |
36 | Removal of old antenna and Installation of array type antenna with flange for existing RTG to be mounted on 6" still well. |
37 | Installation, Testing and Commissioning of multi point temperature averagingsensorwith integrated water interface probe (MSTW) along with mounting accessories etc with minimum 8 elements temperature sensor (for above ground tanks - MS) complete as per specification and tender document. |
38 | Installation, Testing and Commissioning of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment etc For Vertical Product tanks complete as per specification and tender document |
39 | Installation, Calibration, Testing, and CommissioningFlameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon gas detectors along with calibration kit, accessories and structural supports etc as per specification and tender document. |
40 | Point type Infrared detector |
41 | Open path type Infrared detector (0-90m) along with alignment telescope, configuration & Testing kit etc |
42 | Note: Laying, glanding, ferruling, termination of cables shall be along with accessories like certified double compression cable glands with PVC shrouds, plugs for excessentries, SS 316 engraved tag plate, mounting clamp, SS 316 fasteners, conduits, structural steel for mounting of equipments, making RCC trenches with cover wherever required, hume pipes, Aluminium tags, lugs, ferrules,etc |
43 | Laying, glanding, ferruling, termination of FRLS Armoured Copper Power cable as per tender specifications. |
44 | 4C x 4 sqmm |
45 | Laying, glanding, ferruling, termination of FRLS Armoured Copper Signal cable as per tender specifications. |
46 | 6P x 1.5 sqmm |
47 | Laying, glanding, ferruling, termination of FRLS Armoured Copper Control cable as per tender specifications. |
48 | 6C x 1.5 sqmm |
49 | 24C x 1.5 sqmm |
50 | 36C x 1.5 sqmm |
51 | Laying, glanding, ferruling, termination of FS Armoured Copper Signal cable as per tender specifications. |
52 | 2P x 1.5 sqmm |
53 | Laying, glanding, ferruling, termination of FS Armoured Copper Control cable as per tender specifications. |
54 | 12C x 1.5 sqmm |
55 | 2C x 1.5 sqmm |
56 | Laying, glanding, ferruling, termination of 1C x 6 Sq. mm FRLS Flexible copper insulated green wirefor earthinginstruments and junction boxes etc complete as per specification and tender document |
57 | Fabrication, cutting, laying and connecting of GI strip ( 50mm X 6mm) with Hot dip galvanizing (800 gm/m2 as per IS 4759) along with accessories required for complete Terminal Automation System as per Standard Design Engineering, specification and tender document. |
58 | Laying of anodized Aluminium perforated cable trays (2.5mm Thick and 25mm edge height), tray covers (1.5mm Thick and 10 mm edge height) along with structural steel for mounting of the cable tray. Complete as per specifications / tender documents- |
59 | 50 mm |
60 | 100 mm |
61 | 200 mm |
62 | Installation of Exd/FLP Junction Box (Power/Control/Signal JB) with IP 65 as per specification suitable for hazardous area of zone 1, group IIA/IIB, T3 or better having CCOE/CMRI approval. It shall be complete in all respect. Accessories like certified double compression cable glands with PVC shrouds & plugs for excessentries, SS 316 engraved tag plate, mounting clamp & SS 316 fasteners.Complete as perspecification / tender documents. |
63 | Installation, testing and commissioning of Exd/FLP Local Push button Station with Indicating Lamp for ROSOV |
64 | Installation, testing and commissioning of Exd/FLP Local Push button Station with Indicating Lamp for DBBV |
65 | Installation, testing and commissioning of Exd/FLP Local Push button Station with Indicating Lamp for MOV |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy