Department of Defence Production has published Bids Are Invited For 1 (Lub Oil Priming Pump For Port & Stbd Main Enginemotor Driven Main Engine Lub Oil Priming Pumpmake; Tushaco Pumps Capacity; 10 M3/Hr) - Dismantle, Decouple Pump And Motor, Disconnect All Pipeline, Remove Electrical Connections Of Mo. Submission Date for this Tender is 01-02-2022. Tanks and Cylinders Tenders in Goa. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Dec-2021 | 07-01-2022 | ||
2 | 10-Jan-2022 | 14-01-2022 | ||
3 | 11-Jan-2022 | 21-01-2022 | ||
4 | 20-Jan-2022 | 28-01-2022 | ||
5 | 29-Jan-2022 | 01-02-2022 |
Sl. No. | Item Title | Item Description |
1 | 1 (Lub oil priming pump for Port & STBD Main EngineMotor Driven Main Engine Lub Oil Priming pump Make; TUSHACO PUMPS Capacity; 10 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
2 | 2 (Lub oil priming pump for Port & STBD Main EngineMotor Driven Main Engine Lub Oil Priming pump Make; TUSHACO PUMPS Capacity; 10 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, do assembely of pump, painting by approved scheme |
3 | 3 (Lub oil priming pump for Port & STBD Main EngineMotor Driven Main Engine Lub Oil Priming pump Make; TUSHACO PUMPS Capacity; 10 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
4 | 1 (Main Engine Stand-by Sea Water Circulating Pump Main Engine Stand-by Sea Water Circulating Pump Make; BE PUMPS Model; SBV100 - 200M Capacity; 200 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
5 | 2 (Main Engine Stand-by Sea Water Circulating Pump Main Engine Stand-by Sea Water Circulating Pump Make; BE PUMPS Model; SBV100 - 200M Capacity; 200 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, pressure guages.do assembely of pump, painting by approved scheme |
6 | 3 (Main Engine Stand-by Sea Water Circulating Pump Main Engine Stand-by Sea Water Circulating Pump Make; BE PUMPS Model; SBV100 - 200M Capacity; 200 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
7 | 1 (Gear Box Lub Oil Pump- Port & STBD Gear Box Lub Oil Pump(MD) Make; TUSHACO PUMPS Capacity; 10 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
8 | 2 (Gear Box Lub Oil Pump- Port & STBD Gear Box Lub Oil Pump(MD) Make; TUSHACO PUMPS Capacity; 10 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, do assembely of pump, painting by approved scheme |
9 | 3 (Gear Box Lub Oil Pump- Port & STBD Gear Box Lub Oil Pump(MD) Make; TUSHACO PUMPS Capacity; 10 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
10 | 1 (A/C Sea Water pump no.1 A/C Sea Water pump Make; BE PUMPS Model; BP 65-125/BV50-160L. Capacity; 35 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
11 | 2 (A/C Sea Water pump no.1 A/C Sea Water pump Make; BE PUMPS Model; BP 65-125/BV50-160L. Capacity; 35 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows.do assembely of pump, painting by approved scheme |
12 | 3 (A/C Sea Water pump no.1 A/C Sea Water pump Make; BE PUMPS Model; BP 65-125/BV50-160L. Capacity; 35 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
13 | 1 (A/C Chilled Water pump no.1 A/C Chilled Water pump Make; BE PUMPS Model; BP 65-125/BV50-160L Capacity; 35 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
14 | 2 (A/C Chilled Water pump no.1 A/C Chilled Water pump Make; BE PUMPS Model; BP 65-125/BV50-160L Capacity; 35 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows.do assembely of pump, painting by approved scheme |
15 | 3 (A/C Chilled Water pump no.1 A/C Chilled Water pump Make; BE PUMPS Model; BP 65-125/BV50-160L Capacity; 35 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
16 | 1 (Fuel Transfer Pump no.1 Fuel Transfer Pump Make; JOHNSON PUMP Model; CH 80-250/RGB 6 Capacity; 12 M3/Hr ) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
17 | 2 (Fuel Transfer Pump no.1 Fuel Transfer Pump Make; JOHNSON PUMP Model; CH 80-250/RGB 6 Capacity; 12 M3/Hr ) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump foundation, do assembely of pump, painting by approved scheme |
18 | 3 (Fuel Transfer Pump no.1 Fuel Transfer Pump Make; JOHNSON PUMP Model; CH 80-250/RGB 6 Capacity; 12 M3/Hr ) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
19 | 1 (Fire main pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 100 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
20 | 2 (Fire main pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 100 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
21 | 3 (Fire main pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 100 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
22 | 1 (Ballast pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 200 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
23 | 2 (Ballast pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 200 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
24 | 3 (Ballast pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 200 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
25 | 1 (Salvage pump no.1 Salvage Pump Make; Beacon Weir Model; 300 TPH Capacity; 300 M3/HR) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
26 | 2 (Salvage pump no.1 Salvage Pump Make; Beacon Weir Model; 300 TPH Capacity; 300 M3/HR) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
27 | 3 (Salvage pump no.1 Salvage Pump Make; Beacon Weir Model; 300 TPH Capacity; 300 M3/HR) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
28 | 1 (Domestic F/W pump no.1 Domestic Fresh Water pump Make; BE PUMPS A 4131 KK - DGS2 - 431 - MS3 Model; A4131KK-DGS2-431-MS3 Capacity; 6.5 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
29 | 2 (Domestic F/W pump no.1 Domestic Fresh Water pump Make; BE PUMPS A 4131 KK - DGS2 - 431 - MS3 Model; A4131KK-DGS2-431-MS3 Capacity; 6.5 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
30 | 3 (Domestic F/W pump no.1 Domestic Fresh Water pump Make; BE PUMPS A 4131 KK - DGS2 - 431 - MS3 Model; A4131KK-DGS2-431-MS3 Capacity; 6.5 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
31 | 1 (F/W Booster pump F/W Booster pump Make; BE PUMPSA 4131 KK - DGS2 - 431 - MS3 Model; AO3625KK-DGS2-431-MS3 Capacity; 3 M3/Hr0 | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
32 | 2 (F/W Booster pump F/W Booster pump Make; BE PUMPSA 4131 KK - DGS2 - 431 - MS3 Model; AO3625KK-DGS2-431-MS3 Capacity; 3 M3/Hr0 | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
33 | 3 (F/W Booster pump F/W Booster pump Make; BE PUMPSA 4131 KK - DGS2 - 431 - MS3 Model; AO3625KK-DGS2-431-MS3 Capacity; 3 M3/Hr0 | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
34 | 1 (Flight Deck Fire pump Flight Deck Fire pump Make; BE PUMPS Model; A 5121 KK-DGS2-431-MS3 Capacity; 14.33 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
35 | 2 (Flight Deck Fire pump Flight Deck Fire pump Make; BE PUMPS Model; A 5121 KK-DGS2-431-MS3 Capacity; 14.33 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
36 | 3 (Flight Deck Fire pump Flight Deck Fire pump Make; BE PUMPS Model; A 5121 KK-DGS2-431-MS3 Capacity; 14.33 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
37 | 1 (Bilge pump Make; BE PUMPS Model; A 5121 KK-DGS2-431-MS3 Capacity; 5 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
38 | 2 (Bilge pump Make; BE PUMPS Model; A 5121 KK-DGS2-431-MS3 Capacity; 5 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
39 | 3 (Bilge pump Make; BE PUMPS Model; A 5121 KK-DGS2-431-MS3 Capacity; 5 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
40 | 1 (Aux Bilge pumpAux Bilge pump) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
41 | 2 (Aux Bilge pumpAux Bilge pump) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
42 | 3 (Aux Bilge pumpAux Bilge pump) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
43 | Portable Submersible Pumps 20 TPH Portable Submersible pump Make; MODY Model; G 504/L554 Capacity; 20 / 40 / 100 TPH Portable Submersible Pumps 20 TPH | Undetake following on Portable Submersible pump (20 TPH)(a)Dismantle the pump |
44 | 1 (Portable Submersible Pumps 20 TPH) | (b)Replace all consumables and defective/ worn out parts including mechnaincal seal and bearings |
45 | 2 (Portable Submersible Pumps 20 TPH) | (c)Carryout rewinding of the rotor |
46 | 3 (Portable Submersible Pumps 20 TPH) | (d)Prove Pump for rated capacity post overhaul/ repairs |
47 | 4 (Portable Submersible Pumps 20 TPH) | Undetake following on Portable Submersible pump (40 TPH) |
48 | 5 (Portable Submersible Pumps 20 TPH) | (a)Dismantle the pump |
49 | 6 (Portable Submersible Pumps 20 TPH) | (b)Replace all consumables and defective/ worn out parts including mechnaincal seal and bearings |
50 | 7 (Portable Submersible Pumps 20 TPH) | (c)Carryout rewinding of the rotor |
51 | 8 (Portable Submersible Pumps 20 TPH) | (d)Prove Pump for rated capacity post overhaul/ repairs |
52 | 9 (Portable Submersible Pumps 20 TPH) | Undetake following on Portable Submersible pump (100 TPH) |
53 | 10 (Portable Submersible Pumps 20 TPH) | (a)Dismantle the pump |
54 | 11 (Portable Submersible Pumps 20 TPH) | (b)Replace all consumables and defective/ worn out parts including mechnaincal seal and bearings |
55 | 12 (Portable Submersible Pumps 20 TPH) | (c)Carryout rewinding of the rotor |
56 | 13 (Portable Submersible Pumps 20 TPH) | (d)Prove Pump for rated capacity post overhaul/ repairs |
57 | Non-submersible DD pump Non-submersible DD pump | Undetake following on non-Submersible DD pump (37 TPH)(a)Remove the pump and take to shop floor. |
58 | 1 (Non-submersible DD pump) | (b)Dismantle pump and examine parts for wear. |
59 | 2 (Non-submersible DD pump) | (c)Gauge all the parts |
60 | 3 (Non-submersible DD pump) | (d)Replace mechanical seal. |
61 | 4 (Non-submersible DD pump) | (e)Renew all gaskets |
62 | 5 (Non-submersible DD pump) | (f) Replace Discharge valve |
63 | 6 (Non-submersible DD pump) | (g)Dismantle and strip the engine part completely |
64 | 7 (Non-submersible DD pump) | (h)Examine all parts for wear, Replace all wornout parts. |
65 | 8 (Non-submersible DD pump) | (j) Replace injector |
66 | 9 (Non-submersible DD pump) | (k)Replace fuel tank |
67 | 10 (Non-submersible DD pump) | (l) Renew SV mounts. |
68 | 11 (Non-submersible DD pump) | (m)Carry out performance trial on completion in presence of Naval Trials Authority. Rectify defect observed during trials. |
69 | AVCAT System Filter water absorber Make; FACET Model; HCS 1514F 1A 28AVCAT Circulation Pump | (a) Overhaul AVCAT circulation pump as per ser SOW 5.(b) Replace Suction (0-10 kg) and discharge (-1.5 to 1.5 kg) pressure gauges.(c) Replace gauge line for pressure gauge along with suitable end fittings and cocks (Mat - Cu, Size - 10 mm, Length - 2 m).(d)Carry out performance trial on completion. Ensure nil leakage from all joints / flanges / adaptors.Trails to be proved to naval trail authority |
70 | AVCAT Transfer Pump | (a) Overhaul AVCAT transfer pump as per ser SOW 5.(b) Replace Suction (0-10 kg) and discharge (-1.5 to 1.5 kg) pressure gauges.(c) Replace gauge line for pressure gauge along with suitable end fittings and cocks (Mat - Cu, Size - 10 mm, Length - 2 m).(d)Carry out performance trial on completion. Ensure nil leakage from all joints / flanges / adaptors.Trails to be proved to naval trail authority |
71 | 1 (Filter water absorber no.1) | (a)Replace the pressure differential gauge and DP switch. |
72 | 2 (Filter water absorber no.1) | (b)Replace all drain valves. |
73 | 3 (Filter water absorber no.1) | (c)Renew the filter water absorber unit |
74 | 1 (Filter water absorber no.2) | (a)Replace the pressure differential gauge and DP switch. |
75 | 2 (Filter water absorber no.2) | (b)Replace all drain valves. |
76 | 3 (Filter water absorber no.2) | (c)Renew the filter water absorber unit |
77 | 1 (OILY WATER SEPARATOR Make; SUYASH ENTERPRISES Model; SD - 5 Capacity; 5 M3/Hr OWS Bilge pump) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
78 | 2 (OILY WATER SEPARATOR Make; SUYASH ENTERPRISES Model; SD - 5 Capacity; 5 M3/Hr OWS Bilge pump) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, calibrate 4 Nos pressure guages, do assembely of pump, painting by approved scheme |
79 | 3 (OILY WATER SEPARATOR Make; SUYASH ENTERPRISES Model; SD - 5 Capacity; 5 M3/Hr OWS Bilge pump) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
80 | Astern Fueling Pump Reeler | Overhauling of motor as per SOW 1 |
81 | 1 (Astern Fueling Pump Reeler, Motor) | Procure and replace break assembly |
82 | 1 Astern Fueling Pump Reeler, Control Panel | Overhauling of control panel and remote control as per SOW 2 |
83 | 2 Astern Fueling Pump ReelerControl Panel | Procure and replace the limit switches(Qty 02) |
84 | 1 (Steering Gear Control System) | Overhauling of main motors starter and Lub motors starters subject to QC checks. Carry out trials on completion of repairs. I/P - 415V 50Hz 3Phase |
85 | 2 (Steering Gear Control System) | Overhaul ( rewinding, varnishing, renewing terminal plates & cooling fan)02 Nos. MainMotors (415 v, 50 hz, 3 ph, 15 Kw) and one Lub Motor (415 v, 50 hz, 3 ph, 0.65 Kw) Carry out trials, check for SPM readings, starting and running current and compare with Motor designparameters and optimum performance. renew the foundation of motors. |
86 | 3 (Steering Gear Control System) | Calibration of all Ammeters and hours run meter fitted in starter panels |
87 | 4 (Steering Gear Control System) | Purchase and replace following components:- 02 Nos under voltage relay, 02 Nos. Phase failure relay, 02 Nos. Overload relays, 02 Nos Latch relay and 10 Nos Solid State Relays |
88 | Astern Fueling Pump Reeler Make: M/s ECC, Kokata Model: - 415v 50Hz 3 phae 15 KW | Overhauling of motor as per SOW 1. |
89 | Astern Fueling Pump Reeler Motor | Procure and replace break assembly |
90 | 1 (Astern Fueling Pump ReelerControl Panel) | Overhauling of control panel and remote control as per SOW 2 |
91 | 2 (Astern Fueling Pump ReelerControl Panel) | Procure and replace the limit switches(Qty 02) |
92 | Astern Fueling Pump Make:M/s Jolly Engineering, Kokata, Model: 415V, 50Hz 3 phaes 75 K | Overhauling of motor as per SOW 1 |
93 | Astern Fueling PumpMotor | Rewiring from control panel to motor |
94 | 1 (Astern Fueling Pump, Starter Panel) | Overhauling of control panel and remote control panel as per sow 2 |
95 | 2 (Astern Fueling Pump, Starter Panel) | Procure and renewal of remote control of starter |
96 | Ballast Pump Make: M/s Jolly Engineering , Kokata, Motor Narhari Model: - 18.5 KW | Overhauling of Motor as per SOW 1 |
97 | Ballast PumpMotor | Check insulation of all cable, procure and replace cable if found defective |
98 | Ballast Pumpstarter Panel | Overhauling of starter and remote control panel as per SOW 2 |
99 | Hull and fire pumpMake: M/s M/s Jolly Engineering, Kokata,Model: - 40 KW | Overhauling of Motor as per SOW 1 by OEM. |
100 | Hull and fire pump Motor | Check insulation of all cable, procure and replace cable if found defective |
101 | Hull and fire pump,starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
102 | Sea water stand by PumpMake: M/s ECC, Kokata, Motor Narhari Model. | Overhauling of Motor as per SOW 1 |
103 | Sea water stand by Pump,Motor | Check insulation of all cable, procure and replace cable if found defective |
104 | Sea water stand by Pump, starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
105 | Bilge Pump ,Make: M/s ECC, Kokata, Motor Narhari Model:1.5 KW, 415V, 3 phase 50Hz OEM"s | Overhauling of Motor as per SOW 1 |
106 | Bilge Pump, Motor | Check insulation of all cable, procure and replace cable if found defective |
107 | Bilge Pump starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
108 | Aux Bilge Pump Make: M/s ECC, Kokata, Motor Narhari Model:415V, 3 phase 50Hz 1.5 KW OEM"s | Overhauling of Motor as per SOW 1 |
109 | Aux Bilge Pump Motor | Check insulation of all cable, procure and replace cable if found defective |
110 | Aux Bilge Pump starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
111 | Fire Pump flight Deck , | Overhauling of Motor as per SOW 1 (: M/s ECC, Kokata, Motor Narhari Model:415V, 3 phase 50Hz 7.5 KW ) |
112 | Fire Pump flight Deck , Motor | Check insulation of all cable, procure and replace cable if found defective |
113 | Fire Pump flight Deck , starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
114 | Fresh water booster pump : M/s ECC, Kokata, Motor Narhari Model: 415V, 3 phase 50Hz 2.2 KW OEM"s | Overhauling of Motor as per SOW 1 |
115 | Fresh water booster pump Motor | Check insulation of all cable, procure and replace cable if found defective |
116 | Fresh water booster pump starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
117 | 1 Domestic Freshwater pump | Overhauling of Motor as per SOW 1 ( M/s ECC, Kokata, Motor Narhari Model: 415V, 3 phase 50Hz 5.5 KW OEM"s ) |
118 | 2 Domestic Freshwater pump | Check insulation of all cable, procure and replace cable if found defective |
119 | Domestic Freshwater pump starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
120 | Salvage Pump Make: M/s Beacon Weir Ltd Model: 415v, 50Hz 3 phase 30 KW OEM"s | Overhauling of motor as per SOW 1 |
121 | Salvage Pump Starter Panel | Overhauling of control panel and remote control as per SOW 2 |
122 | CPP Booster Pump Make: M/s Siemens Model:415V, 50Hz 3 phase 15 KW OEM"s | Overhauling of motor as per SOW 1 |
123 | CPP Booster Pump Starter | Overhauling of control panel and remote control as per SOW 2 |
124 | Pressure Maintained Motor (CPP)Make: M/s Siemens Model: 415V, 50Hz 3 phase 1.1 KW | Overhauling of motor as per SOW 1 |
125 | Pressure Maintained Motor (CPP) Starter Panel | Overhauling of control panel and remote control as per SOW 2 |
126 | CPP Drain Pump Make: M/s Siemens Model: 415V, 50Hz 3 phase 0.75 KW | Overhauling of motor as per SOW 1 |
127 | CPP Drain Pump Starter Panel | Overhauling of control panel and remote control as per SOW 2 |
128 | Main Engine Lube Oil Priming Pump | Overhauling of motor as per SOW 1 (Make: M/s Narhari Engg Works/Eqpt Model: 415V, 50Hz 3 phase 5.5 KW OEM"s) |
129 | Main Engine Lube Oil Priming Pump Starter Panel | Overhauling of control panel and remote control as per SOW 2 |
130 | Lube oil pump motor for Gear Box | Overhauling of motor as per SOW 1(Make: M/s Narhari Engg Works/Eqpt Model: 415V, 50Hz 3 phase 5.5 KW Motor Lub oil pump for Gear Box - Narhari Engg Rating:5.5 KW, Motor) |
131 | Lube oil pump motor for Gear Box Starter Panel | Overhauling of Starter and remote control as per SOW 2 |
132 | Avcat Feuling Pump Make: M/s Narhari Engg Works/Eqpt Model: 415V, 50Hz 3 phase 3.7 KW OEM"s | Overhauling of motor as per SOW 1 |
133 | Avcat Feuling Pump ,Starter Panel | Overhauling of Starter and remote control as per SOW 2 |
134 | Avcat Transfer Pump,Make: M/s Narhari Engg Works/Eqpt Model: 415V, 50Hz 3 phase 3.7 KW OEM"s | Overhauling of motor as per SOW 1 |
135 | Avcat Transfer Pump ,Starter | Overhauling of Starter and remote control as per SOW 2 |
136 | StrippingPump Make: M/s Alstom Ltd Model: 415V, 50Hz 3 phase 9.3 KW OEM"s | Overhauling of motor as per SOW 1 |
137 | StrippingPump , Starter panel | Overhauling of Starter and remote control as per SOW 2 |
138 | Greasing Pump (steering) | Overhauling of motor as per SOW 1M/s(Veljan)Deninson Hydraulics India Ltd Model:415V, 50Hz 3 phase 0.55 KW OEM"s ) |
139 | Steering Gear Pump | Overhauling of motor as per SOW 1 by OEM. (: M/s (Veljan) Deninson Hydraulics India Ltd Model:415V, 50Hz 3 phase 15 KW OEM"s) |
140 | Steering Gear Pump, Starter Panel | Overhauling of control panel as per SOW 2 |
141 | 1 (MANDATORY SPARES ) Astern Fueling Pump Reeler | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
142 | 2 (MANDATORY SPARES ) Astern Fueling Pump Reeler | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
143 | 3 (MANDATORY SPARES ) Astern Fueling Pump Reeler | EA441-890 PUSH BUTTON START |
144 | 4 (MANDATORY SPARES ) Astern Fueling Pump Reeler | EA441-891 PUSH BUTTON STOP |
145 | 5 (MANDATORY SPARES ) Astern Fueling Pump Reeler | CE15FN3 CONTACTOR 30A |
146 | 6 (MANDATORY SPARES ) Astern Fueling Pump Reeler | 5RB12461PM20 MOTOR PROTECTION UNIT |
147 | 7 (MANDATORY SPARES ) Astern Fueling Pump Reeler | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
148 | 1 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | Bearing 6317/ 6317 |
149 | 2 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
150 | 3 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
151 | 4 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | EA441-890 PUSH BUTTON START |
152 | 5 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
153 | 6 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | CE15HN3 CONTACTOR |
154 | 7 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
155 | 8 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
156 | 9 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | ROTARY SWITCH |
157 | 1 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | Bearing 6317/ 6317 |
158 | 2 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
159 | 3 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
160 | 4 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | EA441-890 PUSH BUTTON START |
161 | 5 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
162 | 6 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | CE15HN3 CONTACTOR |
163 | 7 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
164 | 8 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
165 | 9 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | 3 CORE , 16 SQ.MM |
166 | 10 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | BRAKE ASSEMBLY |
167 | 11 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | LIMIT SWITCH |
168 | 12 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | MCB |
169 | 1 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | MOTOR BEARING 6210ZZ/6210ZZ |
170 | 2 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
171 | 3 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
172 | 4 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | EA441-890 PUSH BUTTON START |
173 | 5 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
174 | 6 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | CE15HN3 CONTACTOR |
175 | 7 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
176 | 8 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
177 | 9 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | MCB |
178 | 1 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | Bearing 6312/6312 |
179 | 2 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
180 | 3 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
181 | 4 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
182 | 5 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
183 | 6 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
184 | 7 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
185 | 8 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
186 | 9 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | MCB |
187 | 1 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | MOTOR BEARING 6312 |
188 | 2 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
189 | 3 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
190 | 4 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
191 | 5 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
192 | 6 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
193 | 7 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
194 | 8 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
195 | 9 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | MCB |
196 | 1 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | MOTOR BEARING 6205ZZ |
197 | 2 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
198 | 3 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
199 | 4 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | EA441-890 PUSH BUTTON START |
200 | 5 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
201 | 6 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | CE15HN3 CONTACTOR |
202 | 7 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
203 | 8 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
204 | 9 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | MCB |
205 | 1 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | Bearing 6208ZZ/6208ZZ |
206 | 2 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
207 | 3 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
208 | 4 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
209 | 5 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
210 | 6 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
211 | 7 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
212 | 8 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
213 | 9 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | MCB |
214 | 1 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | MOTOR BEARING 6206ZZ & 6205ZZ |
215 | 2 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
216 | 3 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
217 | 4 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
218 | 5 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
219 | 6 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
220 | 7 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
221 | 8 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
222 | 9 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | MCB |
223 | 1 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | MOTOR BEARING 6208ZZ |
224 | 2 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
225 | 3 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
226 | 4 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | EA441-890 PUSH BUTTON START |
227 | 5 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
228 | 6 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | CE15HN3 CONTACTOR |
229 | 7 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
230 | 8 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
231 | 9 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | MCB |
232 | 1 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | MOTOR BEARING 6312ZZ/ 6309ZZ |
233 | 2 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
234 | 3 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
235 | 4 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
236 | 5 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
237 | 6 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
238 | 7 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
239 | 8 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
240 | 9 (MANDATORY SPARES ) SALVAGE MOTOR & CONTROL PANEL | MCB |
241 | 1 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | MOTOR BEARING 6209ZZ |
242 | 2 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
243 | 3 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
244 | 4 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
245 | 5 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
246 | 6 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
247 | 7 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
248 | 8 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
249 | 9 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | MCB |
250 | 1 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | MOTOR BEARING 6205ZZ/6205ZZ |
251 | 2 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
252 | 3 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
253 | 4 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | EA441-890 PUSH BUTTON START |
254 | 5 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
255 | 6 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | CE15HN3 CONTACTOR |
256 | 7 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
257 | 8 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
258 | 9 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | MCB |
259 | 1 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | MOTOR BEARING 6004ZZ |
260 | 2 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
261 | 3 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
262 | 4 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | EA441-890 PUSH BUTTON START |
263 | 5 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
264 | 6 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | CE15HN3 CONTACTOR |
265 | 7 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
266 | 8 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
267 | 9 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | FLOAT LIMIT SWITCH |
268 | 10 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | MCB |
269 | 1 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | MOTOR BEARING 6208ZZ |
270 | 2 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
271 | 3 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
272 | 4 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | EA441-890 PUSH BUTTON START |
273 | 5 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
274 | 6 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | CE15HN3 CONTACTOR |
275 | 7 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
276 | 8 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
277 | 9 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | MCB |
278 | 1 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | MOTOR BEARING 6208ZZ |
279 | 2 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
280 | 3 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
281 | 4 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | EA441-890 PUSH BUTTON START |
282 | 5 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
283 | 6 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | CE15HN3 CONTACTOR |
284 | 7 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
285 | 8 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
286 | 9 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | MCB |
287 | 1 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | MOTOR BEARING 6206ZZ/6206ZZ |
288 | 2 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | MAIN CONTACTOR |
289 | 3 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | AUXILARY CONTACT |
290 | 4 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | MPR |
291 | 5 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | TRANSFORMER |
292 | 6 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | LED INDICATION LAMP |
293 | 7 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | PUSH BUTTON |
294 | 8 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | ROTARY SWITCH |
295 | 9 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | FUSE |
296 | 1 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | MOTOR BEARING 6309ZZ/6309ZZ |
297 | 2 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
298 | 3 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
299 | 4 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
300 | 5 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
301 | 6 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
302 | 7 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
303 | 8 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
304 | 9 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | MCB |
305 | 1 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | MOTOR BEARING 6202ZZ |
306 | 2 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
307 | 3 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
308 | 4 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
309 | 5 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
310 | 6 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
311 | 7 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
312 | 8 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
313 | 9 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | MCB |
314 | 1 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
315 | 2 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
316 | 3 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
317 | 4 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
318 | 5 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
319 | 6 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
320 | 7 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
321 | 8 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | MCB |
322 | 9 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140004 AUX. CONTACT 110V AC "D1" |
323 | 10 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140013 INDICATING LAMP 415V AC "H1" |
324 | 11 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140015 INDICATING LAMP 415V AC "H5" |
325 | 12 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140014 INDICATING LAMP 240V AC "H6" |
326 | 13 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140010 HRC FUSE BASE & LINK 2A |
327 | 14 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140023 40/38A POWER CONTACTOR "C1" |
328 | 15 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | CONTACTOR AUC 1NO-1NC BCH |
329 | 16 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | TIME DELAY RELAY |
330 | 18 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30120094 BEARING DRIVING END 6310ZZ |
331 | 19 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30120095 BEARING NON-DRIVE END 6310ZZ |
332 | 20 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30120096 THRUST WASHER |
333 | 21 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30120097 OIL SEAL |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail