Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-01-2022 | 01-02-2022 | ||
| 2 | 20-01-2022 | 28-01-2022 | ||
| 3 | 11-01-2022 | 21-01-2022 | ||
| 4 | 10-01-2022 | 14-01-2022 | ||
| 5 | 28-12-2021 | 07-01-2022 |
| Sl. No. | Item Title | Item Description |
| 1 | 1 (Lub oil priming pump for Port & STBD Main EngineMotor Driven Main Engine Lub Oil Priming pumpMake; TUSHACO PUMPS Capacity; 10 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 2 | 2 (Lub oil priming pump for Port & STBD Main EngineMotor Driven Main Engine Lub Oil Priming pumpMake; TUSHACO PUMPS Capacity; 10 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, do assembely of pump, painting by approved scheme |
| 3 | 3 (Lub oil priming pump for Port & STBD Main EngineMotor Driven Main Engine Lub Oil Priming pumpMake; TUSHACO PUMPS Capacity; 10 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 4 | 1 (Main Engine Stand-by Sea Water Circulating Pump Main Engine Stand-by Sea Water Circulating PumpMake; BE PUMPS Model; SBV100 - 200M Capacity; 200 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 5 | 2 (Main Engine Stand-by Sea Water Circulating Pump Main Engine Stand-by Sea Water Circulating PumpMake; BE PUMPS Model; SBV100 - 200M Capacity; 200 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, pressure guages.do assembely of pump, painting by approved scheme |
| 6 | 3 (Main Engine Stand-by Sea Water Circulating Pump Main Engine Stand-by Sea Water Circulating PumpMake; BE PUMPS Model; SBV100 - 200M Capacity; 200 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 7 | 1 (Gear Box Lub Oil Pump- Port & STBD Gear Box Lub Oil Pump(MD)Make; TUSHACO PUMPSCapacity; 10 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 8 | 2 (Gear Box Lub Oil Pump- Port & STBD Gear Box Lub Oil Pump(MD)Make; TUSHACO PUMPSCapacity; 10 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, do assembely of pump, painting by approved scheme |
| 9 | 3 (Gear Box Lub Oil Pump- Port & STBD Gear Box Lub Oil Pump(MD)Make; TUSHACO PUMPSCapacity; 10 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 10 | 1 (A/C Sea Water pump no.1 A/C Sea Water pumpMake; BE PUMPSModel; BP 65-125/BV50-160L. Capacity; 35 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 11 | 2 (A/C Sea Water pump no.1 A/C Sea Water pumpMake; BE PUMPSModel; BP 65-125/BV50-160L. Capacity; 35 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows.do assembely of pump, painting by approved scheme |
| 12 | 3 (A/C Sea Water pump no.1 A/C Sea Water pumpMake; BE PUMPSModel; BP 65-125/BV50-160L. Capacity; 35 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 13 | 1 (A/C Chilled Water pump no.1 A/C Chilled Water pumpMake; BE PUMPSModel; BP 65-125/BV50-160LCapacity; 35 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 14 | 2 (A/C Chilled Water pump no.1 A/C Chilled Water pumpMake; BE PUMPSModel; BP 65-125/BV50-160LCapacity; 35 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows.do assembely of pump, painting by approved scheme |
| 15 | 3 (A/C Chilled Water pump no.1 A/C Chilled Water pumpMake; BE PUMPSModel; BP 65-125/BV50-160LCapacity; 35 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 16 | 1 (Fuel Transfer Pump no.1 Fuel Transfer PumpMake; JOHNSON PUMPModel; CH 80-250/RGB 6Capacity; 12 M3/Hr ) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 17 | 2 (Fuel Transfer Pump no.1 Fuel Transfer PumpMake; JOHNSON PUMPModel; CH 80-250/RGB 6Capacity; 12 M3/Hr ) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump foundation, do assembely of pump, painting by approved scheme |
| 18 | 3 (Fuel Transfer Pump no.1 Fuel Transfer PumpMake; JOHNSON PUMPModel; CH 80-250/RGB 6Capacity; 12 M3/Hr ) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 19 | 1 (Fire main pump Make; BE PUMPS Model; SBV 80-250 LCapacity; 100 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 20 | 2 (Fire main pump Make; BE PUMPS Model; SBV 80-250 LCapacity; 100 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
| 21 | 3 (Fire main pump Make; BE PUMPS Model; SBV 80-250 LCapacity; 100 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 22 | 1 (Ballast pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 200 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 23 | 2 (Ballast pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 200 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
| 24 | 3 (Ballast pump Make; BE PUMPS Model; SBV 80-250 L Capacity; 200 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 25 | 1 (Salvage pump no.1 Salvage PumpMake; Beacon WeirModel; 300 TPHCapacity; 300 M3/HR) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 26 | 2 (Salvage pump no.1 Salvage PumpMake; Beacon WeirModel; 300 TPHCapacity; 300 M3/HR) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
| 27 | 3 (Salvage pump no.1 Salvage PumpMake; Beacon WeirModel; 300 TPHCapacity; 300 M3/HR) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 28 | 1 (Domestic F/W pump no.1 Domestic Fresh Water pumpMake; BE PUMPS A 4131 KK - DGS2 - 431 - MS3Model; A4131KK-DGS2-431-MS3 Capacity; 6.5 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 29 | 2 (Domestic F/W pump no.1 Domestic Fresh Water pumpMake; BE PUMPS A 4131 KK - DGS2 - 431 - MS3Model; A4131KK-DGS2-431-MS3 Capacity; 6.5 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
| 30 | 3 (Domestic F/W pump no.1 Domestic Fresh Water pumpMake; BE PUMPS A 4131 KK - DGS2 - 431 - MS3Model; A4131KK-DGS2-431-MS3 Capacity; 6.5 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 31 | 1 (F/W Booster pump F/W Booster pumpMake; BE PUMPSA 4131 KK - DGS2 - 431 - MS3Model; AO3625KK-DGS2-431-MS3Capacity; 3 M3/Hr0 | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 32 | 2 (F/W Booster pump F/W Booster pumpMake; BE PUMPSA 4131 KK - DGS2 - 431 - MS3Model; AO3625KK-DGS2-431-MS3Capacity; 3 M3/Hr0 | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
| 33 | 3 (F/W Booster pump F/W Booster pumpMake; BE PUMPSA 4131 KK - DGS2 - 431 - MS3Model; AO3625KK-DGS2-431-MS3Capacity; 3 M3/Hr0 | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 34 | 1 (Flight Deck Fire pump Flight Deck Fire pumpMake; BE PUMPSModel; A 5121 KK-DGS2-431-MS3Capacity; 14.33 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 35 | 2 (Flight Deck Fire pump Flight Deck Fire pumpMake; BE PUMPSModel; A 5121 KK-DGS2-431-MS3Capacity; 14.33 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
| 36 | 3 (Flight Deck Fire pump Flight Deck Fire pumpMake; BE PUMPSModel; A 5121 KK-DGS2-431-MS3Capacity; 14.33 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 37 | 1 (Bilge pump Make; BE PUMPSModel; A 5121 KK-DGS2-431-MS3Capacity; 5 M3/Hr) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 38 | 2 (Bilge pump Make; BE PUMPSModel; A 5121 KK-DGS2-431-MS3Capacity; 5 M3/Hr) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
| 39 | 3 (Bilge pump Make; BE PUMPSModel; A 5121 KK-DGS2-431-MS3Capacity; 5 M3/Hr) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 40 | 1 (Aux Bilge pumpAux Bilge pump) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 41 | 2 (Aux Bilge pumpAux Bilge pump) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, Renew SV mounts, pump stool, suction and discharge flexible rubber bellows, suction and dischage guages and renew guage lines.do assembely of pump, painting by approved scheme |
| 42 | 3 (Aux Bilge pumpAux Bilge pump) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 43 | Portable Submersible Pumps20 TPH Portable Submersible pump Make; MODYModel; G 504/L554Capacity; 20 / 40 / 100 TPH Portable Submersible Pumps 20 TPH | Undetake following on Portable Submersible pump (20 TPH)(a)Dismantle the pump |
| 44 | 1 (Portable Submersible Pumps 20 TPH) | (b)Replace all consumables and defective/ worn out parts including mechnaincal seal and bearings |
| 45 | 2 (Portable Submersible Pumps 20 TPH) | (c)Carryout rewinding of the rotor |
| 46 | 3 (Portable Submersible Pumps 20 TPH) | (d)Prove Pump for rated capacity post overhaul/ repairs |
| 47 | 4 (Portable Submersible Pumps 20 TPH) | Undetake following on Portable Submersible pump (40 TPH) |
| 48 | 5 (Portable Submersible Pumps 20 TPH) | (a)Dismantle the pump |
| 49 | 6 (Portable Submersible Pumps 20 TPH) | (b)Replace all consumables and defective/ worn out parts including mechnaincal seal and bearings |
| 50 | 7 (Portable Submersible Pumps 20 TPH) | (c)Carryout rewinding of the rotor |
| 51 | 8 (Portable Submersible Pumps 20 TPH) | (d)Prove Pump for rated capacity post overhaul/ repairs |
| 52 | 9 (Portable Submersible Pumps 20 TPH) | Undetake following on Portable Submersible pump (100 TPH) |
| 53 | 10 (Portable Submersible Pumps 20 TPH) | (a)Dismantle the pump |
| 54 | 11 (Portable Submersible Pumps 20 TPH) | (b)Replace all consumables and defective/ worn out parts including mechnaincal seal and bearings |
| 55 | 12 (Portable Submersible Pumps 20 TPH) | (c)Carryout rewinding of the rotor |
| 56 | 13 (Portable Submersible Pumps 20 TPH) | (d)Prove Pump for rated capacity post overhaul/ repairs |
| 57 | Non-submersible DD pump Non-submersible DD pump | Undetake following on non-Submersible DD pump (37 TPH)(a)Remove the pump and take to shop floor. |
| 58 | 1 (Non-submersible DD pump) | (b)Dismantle pump and examine parts for wear. |
| 59 | 2 (Non-submersible DD pump) | (c)Gauge all the parts |
| 60 | 3 (Non-submersible DD pump) | (d)Replace mechanical seal. |
| 61 | 4 (Non-submersible DD pump) | (e)Renew all gaskets |
| 62 | 5 (Non-submersible DD pump) | (f) Replace Discharge valve |
| 63 | 6 (Non-submersible DD pump) | (g)Dismantle and strip the engine part completely |
| 64 | 7 (Non-submersible DD pump) | (h)Examine all parts for wear, Replace all wornout parts. |
| 65 | 8 (Non-submersible DD pump) | (j) Replace injector |
| 66 | 9 (Non-submersible DD pump) | (k)Replace fuel tank |
| 67 | 10 (Non-submersible DD pump) | (l) Renew SV mounts. |
| 68 | 11 (Non-submersible DD pump) | (m)Carry out performance trial on completion in presence of Naval Trials Authority. Rectify defect observed during trials. |
| 69 | AVCAT System Filter water absorberMake; FACETModel; HCS 1514F 1A 28AVCAT Circulation Pump | (a) Overhaul AVCAT circulation pump as per ser SOW 5.(b) Replace Suction (0-10 kg) and discharge (-1.5 to 1.5 kg) pressure gauges.(c) Replace gauge line for pressure gauge along with suitable end fittings and cocks (Mat - Cu, Size - 10 mm, Length - 2 m).(d)Carry out performance trial on completion. Ensure nil leakage from all joints / flanges / adaptors.Trails to be proved to naval trail authority |
| 70 | AVCAT Transfer Pump | (a) Overhaul AVCAT transfer pump as per ser SOW 5.(b) Replace Suction (0-10 kg) and discharge (-1.5 to 1.5 kg) pressure gauges.(c) Replace gauge line for pressure gauge along with suitable end fittings and cocks (Mat - Cu, Size - 10 mm, Length - 2 m).(d)Carry out performance trial on completion. Ensure nil leakage from all joints / flanges / adaptors.Trails to be proved to naval trail authority |
| 71 | 1 (Filter water absorber no.1) | (a)Replace the pressure differential gauge and DP switch. |
| 72 | 2 (Filter water absorber no.1) | (b)Replace all drain valves. |
| 73 | 3 (Filter water absorber no.1) | (c)Renew the filter water absorber unit |
| 74 | 1 (Filter water absorber no.2) | (a)Replace the pressure differential gauge and DP switch. |
| 75 | 2 (Filter water absorber no.2) | (b)Replace all drain valves. |
| 76 | 3 (Filter water absorber no.2) | (c)Renew the filter water absorber unit |
| 77 | 1 (OILY WATER SEPARATORMake; SUYASH ENTERPRISESModel; SD - 5Capacity; 5 M3/Hr OWS Bilge pump) | Dismantle, decouple pump and motor, disconnect all pipeline, remove electrical connections of motor and control panel, Remove and keep pump and motor at a clean and safe surface. |
| 78 | 2 (OILY WATER SEPARATORMake; SUYASH ENTERPRISESModel; SD - 5Capacity; 5 M3/Hr OWS Bilge pump) | do cleaning of pumps, measurement of clearences, Renewal of thinned/wornout/damaged parts, carry out dynamic balancing, renewal of all Mechanical/oil seals/bearings and fitment joints, calibrate 4 Nos pressure guages, do assembely of pump, painting by approved scheme |
| 79 | 3 (OILY WATER SEPARATORMake; SUYASH ENTERPRISESModel; SD - 5Capacity; 5 M3/Hr OWS Bilge pump) | Install motor and pump at place, do alignment and coupling of pump and motor, termination of motor and control panel. Take trials and prove pump and motor for satisfactory performance. |
| 80 | Astern Fueling Pump Reeler | Overhauling of motor as per SOW 1 |
| 81 | 1 (Astern Fueling Pump Reeler, Motor) | Procure and replace break assembly |
| 82 | 1 Astern Fueling Pump Reeler, Control Panel | Overhauling of control panel and remote control as per SOW 2 |
| 83 | 2 Astern Fueling Pump ReelerControl Panel | Procure and replace the limit switches(Qty 02) |
| 84 | 1 (Steering Gear Control System) | Overhauling of main motors starter and Lub motors starters subject to QC checks. Carry out trials on completion of repairs. I/P - 415V 50Hz 3Phase |
| 85 | 2 (Steering Gear Control System) | Overhaul ( rewinding, varnishing, renewing terminal plates & cooling fan)02 Nos. MainMotors (415 v, 50 hz, 3 ph, 15 Kw) and one Lub Motor (415 v, 50 hz, 3 ph, 0.65 Kw) Carry out trials, check for SPM readings, starting and running current and compare with Motor designparameters and optimum performance. renew the foundation of motors. |
| 86 | 3 (Steering Gear Control System) | Calibration of all Ammeters and hours run meter fitted in starter panels |
| 87 | 4 (Steering Gear Control System) | Purchase and replace following components:-02 Nos under voltage relay, 02 Nos. Phase failure relay, 02 Nos. Overload relays, 02 Nos Latch relay and 10 Nos Solid State Relays |
| 88 | Astern Fueling Pump Reeler Make: M/s ECC, Kokata Model: - 415v 50Hz 3 phae 15 KW | Overhauling of motor as per SOW 1. |
| 89 | Astern Fueling Pump Reeler Motor | Procure and replace break assembly |
| 90 | 1 (Astern Fueling Pump ReelerControl Panel) | Overhauling of control panel and remote control as per SOW 2 |
| 91 | 2 (Astern Fueling Pump ReelerControl Panel) | Procure and replace the limit switches(Qty 02) |
| 92 | Astern Fueling Pump Make:M/s Jolly Engineering, Kokata, Model: 415V, 50Hz 3 phaes 75 K | Overhauling of motor as per SOW 1 |
| 93 | Astern Fueling PumpMotor | Rewiring from control panel to motor |
| 94 | 1 (Astern Fueling Pump, Starter Panel) | Overhauling of control panel and remote control panel as per sow 2 |
| 95 | 2 (Astern Fueling Pump, Starter Panel) | Procure and renewal of remote control of starter |
| 96 | Ballast Pump Make: M/s Jolly Engineering , Kokata, Motor Narhari Model: - 18.5 KW | Overhauling of Motor as per SOW 1 |
| 97 | Ballast PumpMotor | Check insulation of all cable, procure and replace cable if found defective |
| 98 | Ballast Pumpstarter Panel | Overhauling of starter and remote control panel as per SOW 2 |
| 99 | Hull and fire pumpMake: M/s M/s Jolly Engineering, Kokata,Model: - 40 KW | Overhauling of Motor as per SOW 1 by OEM. |
| 100 | Hull and fire pump Motor | Check insulation of all cable, procure and replace cable if found defective |
| 101 | Hull and fire pump,starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
| 102 | Sea water stand by PumpMake: M/s ECC, Kokata, Motor Narhari Model. | Overhauling of Motor as per SOW 1 |
| 103 | Sea water stand by Pump,Motor | Check insulation of all cable, procure and replace cable if found defective |
| 104 | Sea water stand by Pump, starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
| 105 | Bilge Pump ,Make: M/s ECC, Kokata, Motor Narhari Model:1.5 KW, 415V, 3 phase 50Hz OEM\"s | Overhauling of Motor as per SOW 1 |
| 106 | Bilge Pump, Motor | Check insulation of all cable, procure and replace cable if found defective |
| 107 | Bilge Pump starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
| 108 | Aux Bilge Pump Make: M/s ECC, Kokata, Motor Narhari Model:415V, 3 phase 50Hz 1.5 KW OEM\"s | Overhauling of Motor as per SOW 1 |
| 109 | Aux Bilge Pump Motor | Check insulation of all cable, procure and replace cable if found defective |
| 110 | Aux Bilge Pump starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
| 111 | Fire Pump flight Deck , | Overhauling of Motor as per SOW 1(: M/s ECC, Kokata, Motor Narhari Model:415V, 3 phase 50Hz 7.5 KW ) |
| 112 | Fire Pump flight Deck , Motor | Check insulation of all cable, procure and replace cable if found defective |
| 113 | Fire Pump flight Deck , starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
| 114 | Fresh water booster pump : M/s ECC, Kokata, Motor Narhari Model: 415V, 3 phase 50Hz 2.2 KW OEM\"s | Overhauling of Motor as per SOW 1 |
| 115 | Fresh water booster pump Motor | Check insulation of all cable, procure and replace cable if found defective |
| 116 | Fresh water booster pump starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
| 117 | 1 Domestic Freshwater pump | Overhauling of Motor as per SOW 1( M/s ECC, Kokata, Motor Narhari Model: 415V, 3 phase 50Hz 5.5 KW OEM\"s ) |
| 118 | 2 Domestic Freshwater pump | Check insulation of all cable, procure and replace cable if found defective |
| 119 | Domestic Freshwater pump starter Panel | Overhauling of starter and remote control panel as per SOW 2 |
| 120 | Salvage Pump Make: M/s Beacon Weir Ltd Model: 415v, 50Hz 3 phase 30 KW OEM\"s | Overhauling of motor as per SOW 1 |
| 121 | Salvage Pump Starter Panel | Overhauling of control panel and remote control as per SOW 2 |
| 122 | CPP Booster Pump Make: M/s Siemens Model:415V, 50Hz 3 phase 15 KW OEM\"s | Overhauling of motor as per SOW 1 |
| 123 | CPP Booster Pump Starter | Overhauling of control panel and remote control as per SOW 2 |
| 124 | Pressure Maintained Motor (CPP)Make: M/s Siemens Model: 415V, 50Hz 3 phase 1.1 KW | Overhauling of motor as per SOW 1 |
| 125 | Pressure Maintained Motor (CPP) Starter Panel | Overhauling of control panel and remote control as per SOW 2 |
| 126 | CPP Drain Pump Make: M/s Siemens Model: 415V, 50Hz 3 phase 0.75 KW | Overhauling of motor as per SOW 1 |
| 127 | CPP Drain Pump Starter Panel | Overhauling of control panel and remote control as per SOW 2 |
| 128 | Main Engine Lube Oil Priming Pump | Overhauling of motor as per SOW 1(Make: M/s Narhari Engg Works/Eqpt Model: 415V, 50Hz 3 phase 5.5 KW OEM\"s) |
| 129 | Main Engine Lube Oil Priming Pump Starter Panel | Overhauling of control panel and remote control as per SOW 2 |
| 130 | Lube oil pump motor for Gear Box | Overhauling of motor as per SOW 1(Make: M/s Narhari Engg Works/Eqpt Model: 415V, 50Hz 3 phase 5.5 KW Motor Lub oil pump for Gear Box - Narhari EnggRating:5.5 KW, Motor) |
| 131 | Lube oil pump motor for Gear Box Starter Panel | Overhauling of Starter and remote control as per SOW 2 |
| 132 | Avcat Feuling Pump Make: M/s Narhari Engg Works/Eqpt Model: 415V, 50Hz 3 phase 3.7 KW OEM\"s | Overhauling of motor as per SOW 1 |
| 133 | Avcat Feuling Pump ,Starter Panel | Overhauling of Starter and remote control as per SOW 2 |
| 134 | Avcat Transfer Pump,Make: M/s Narhari Engg Works/Eqpt Model: 415V, 50Hz 3 phase 3.7 KW OEM\"s | Overhauling of motor as per SOW 1 |
| 135 | Avcat Transfer Pump ,Starter | Overhauling of Starter and remote control as per SOW 2 |
| 136 | StrippingPump Make: M/s Alstom Ltd Model: 415V, 50Hz 3 phase 9.3 KW OEM\"s | Overhauling of motor as per SOW 1 |
| 137 | StrippingPump , Starter panel | Overhauling of Starter and remote control as per SOW 2 |
| 138 | Greasing Pump (steering) | Overhauling of motor as per SOW 1M/s(Veljan)Deninson Hydraulics India Ltd Model:415V, 50Hz 3 phase 0.55 KW OEM\"s ) |
| 139 | Steering Gear Pump | Overhauling of motor as per SOW 1 by OEM.(: M/s (Veljan) Deninson Hydraulics India Ltd Model:415V, 50Hz 3 phase 15 KW OEM\"s) |
| 140 | Steering Gear Pump, Starter Panel | Overhauling of control panel as per SOW 2 |
| 141 | 1 (MANDATORY SPARES ) Astern Fueling Pump Reeler | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 142 | 2 (MANDATORY SPARES ) Astern Fueling Pump Reeler | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 143 | 3 (MANDATORY SPARES ) Astern Fueling Pump Reeler | EA441-890 PUSH BUTTON START |
| 144 | 4 (MANDATORY SPARES ) Astern Fueling Pump Reeler | EA441-891 PUSH BUTTON STOP |
| 145 | 5 (MANDATORY SPARES ) Astern Fueling Pump Reeler | CE15FN3 CONTACTOR 30A |
| 146 | 6 (MANDATORY SPARES ) Astern Fueling Pump Reeler | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 147 | 7 (MANDATORY SPARES ) Astern Fueling Pump Reeler | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 148 | 1 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | Bearing 6317/ 6317 |
| 149 | 2 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 150 | 3 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 151 | 4 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | EA441-890 PUSH BUTTON START |
| 152 | 5 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
| 153 | 6 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | CE15HN3 CONTACTOR |
| 154 | 7 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 155 | 8 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 156 | 9 (MANDATORY SPARES ) STERN FUELLING PUMP MOTOR & STARTER | ROTARY SWITCH |
| 157 | 1 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | Bearing 6317/ 6317 |
| 158 | 2 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 159 | 3 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 160 | 4 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | EA441-890 PUSH BUTTON START |
| 161 | 5 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
| 162 | 6 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | CE15HN3 CONTACTOR |
| 163 | 7 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 164 | 8 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 165 | 9 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | 3 CORE , 16 SQ.MM |
| 166 | 10 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | BRAKE ASSEMBLY |
| 167 | 11 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | LIMIT SWITCH |
| 168 | 12 (MANDATORY SPARES ) ASTERN FUELLING REELER MOTOR & STARTER | MCB |
| 169 | 1 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | MOTOR BEARING 6210ZZ/6210ZZ |
| 170 | 2 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 171 | 3 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 172 | 4 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | EA441-890 PUSH BUTTON START |
| 173 | 5 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
| 174 | 6 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | CE15HN3 CONTACTOR |
| 175 | 7 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 176 | 8 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 177 | 9 (MANDATORY SPARES ) BALLAST PUMP MOTOR & STARTER | MCB |
| 178 | 1 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | Bearing 6312/6312 |
| 179 | 2 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 180 | 3 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 181 | 4 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 182 | 5 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 183 | 6 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
| 184 | 7 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 185 | 8 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 186 | 9 (MANDATORY SPARES ) FIREMAN MOTOR & CONTROL PANEL | MCB |
| 187 | 1 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | MOTOR BEARING 6312 |
| 188 | 2 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 189 | 3 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 190 | 4 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 191 | 5 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 192 | 6 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
| 193 | 7 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 194 | 8 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 195 | 9 (MANDATORY SPARES ) M/E SEA WATER MOTOR & CONTROL PANEL | MCB |
| 196 | 1 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | MOTOR BEARING 6205ZZ |
| 197 | 2 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 198 | 3 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 199 | 4 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | EA441-890 PUSH BUTTON START |
| 200 | 5 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
| 201 | 6 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | CE15HN3 CONTACTOR |
| 202 | 7 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 203 | 8 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 204 | 9 (MANDATORY SPARES ) AUX. BILGE PUMP MOTOR & STARTER | MCB |
| 205 | 1 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | Bearing 6208ZZ/6208ZZ |
| 206 | 2 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 207 | 3 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 208 | 4 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 209 | 5 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 210 | 6 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
| 211 | 7 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 212 | 8 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 213 | 9 (MANDATORY SPARES ) HELODECK FIREFIGHTING MOTOR & CONTROL PANEL | MCB |
| 214 | 1 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | MOTOR BEARING 6206ZZ & 6205ZZ |
| 215 | 2 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 216 | 3 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 217 | 4 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 218 | 5 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 219 | 6 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
| 220 | 7 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 221 | 8 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 222 | 9 (MANDATORY SPARES ) FRESH WATER BOOSTER MOTOR & CONTROL PANEL | MCB |
| 223 | 1 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | MOTOR BEARING 6208ZZ |
| 224 | 2 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 225 | 3 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 226 | 4 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | EA441-890 PUSH BUTTON START |
| 227 | 5 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
| 228 | 6 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | CE15HN3 CONTACTOR |
| 229 | 7 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 230 | 8 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 231 | 9 (MANDATORY SPARES ) FRESH WATER MOTOR & STARTER | MCB |
| 232 | 1 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | MOTOR BEARING 6312ZZ/ 6309ZZ |
| 233 | 2 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 234 | 3 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 235 | 4 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 236 | 5 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 237 | 6 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | CE15HN3 CONTACTOR |
| 238 | 7 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 239 | 8 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 240 | 9 (MANDATORY SPARES ) SALVAGE MOTOR &CONTROL PANEL | MCB |
| 241 | 1 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | MOTOR BEARING 6209ZZ |
| 242 | 2 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 243 | 3 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 244 | 4 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 245 | 5 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 246 | 6 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
| 247 | 7 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 248 | 8 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 249 | 9 (MANDATORY SPARES ) CPP BOOSTER MOTOR & CONTROL PANEL | MCB |
| 250 | 1 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | MOTOR BEARING 6205ZZ/6205ZZ |
| 251 | 2 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 252 | 3 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 253 | 4 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | EA441-890 PUSH BUTTON START |
| 254 | 5 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
| 255 | 6 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | CE15HN3 CONTACTOR |
| 256 | 7 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 257 | 8 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 258 | 9 (MANDATORY SPARES ) CPP PRESSURE MAINTAINED MOTOR & STARTER | MCB |
| 259 | 1 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | MOTOR BEARING 6004ZZ |
| 260 | 2 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 261 | 3 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 262 | 4 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | EA441-890 PUSH BUTTON START |
| 263 | 5 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
| 264 | 6 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | CE15HN3 CONTACTOR |
| 265 | 7 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 266 | 8 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 267 | 9 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | FLOAT LIMIT SWITCH |
| 268 | 10 (MANDATORY SPARES ) CPP DRAIN MOTOR & STARTER | MCB |
| 269 | 1 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | MOTOR BEARING 6208ZZ |
| 270 | 2 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 271 | 3 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 272 | 4 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | EA441-890 PUSH BUTTON START |
| 273 | 5 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | EA441-891 PUSH BUTTON STOP |
| 274 | 6 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | CE15HN3 CONTACTOR |
| 275 | 7 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 276 | 8 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 277 | 9 (MANDATORY SPARES ) M/E L/O PRIMING PUMP MOTOR & STARTER | MCB |
| 278 | 1 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | MOTOR BEARING 6208ZZ |
| 279 | 2 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 280 | 3 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 281 | 4 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 282 | 5 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 283 | 6 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | CE15HN3 CONTACTOR |
| 284 | 7 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 285 | 8 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 286 | 9 (MANDATORY SPARES ) GBLO PUMP & CONTROL PANEL | MCB |
| 287 | 1 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | MOTOR BEARING 6206ZZ/6206ZZ |
| 288 | 2 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | MAIN CONTACTOR |
| 289 | 3 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | AUXILARY CONTACT |
| 290 | 4 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | MPR |
| 291 | 5 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | TRANSFORMER |
| 292 | 6 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | LED INDICATION LAMP |
| 293 | 7 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | PUSH BUTTON |
| 294 | 8 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | ROTARY SWITCH |
| 295 | 9 (MANDATORY SPARES ) AVCAT TRANSFER & FUELLING MOTOR | FUSE |
| 296 | 1 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | MOTOR BEARING 6309ZZ/6309ZZ |
| 297 | 2 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 298 | 3 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 299 | 4 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 300 | 5 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 301 | 6 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
| 302 | 7 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 303 | 8 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 304 | 9 (MANDATORY SPARES ) STRIPPING MOTOR & CONTROL PANEL | MCB |
| 305 | 1 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | MOTOR BEARING 6202ZZ |
| 306 | 2 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 307 | 3 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 308 | 4 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 309 | 5 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 310 | 6 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
| 311 | 7 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 312 | 8 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 313 | 9 (MANDATORY SPARES ) STEERING GREASING MOTOR & CONTROL PANEL | MCB |
| 314 | 1 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | SDOL/0234/TR TRANSFORMER 440V/230V, 200VA |
| 315 | 2 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | C320KGTC40 CONTACTOR BLOCK 2NO+2NC |
| 316 | 3 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | EA441-890 PUSH BUTTON START |
| 317 | 4 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | EA441-891 PUSH BUTTON STOP |
| 318 | 5 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | CE15HN3 CONTACTOR |
| 319 | 6 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 5RB12461PM20 MOTOR PROTECTION UNIT |
| 320 | 7 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | C320KGSR11 AUX CONTACT BLOCK 1NO-1NC |
| 321 | 8 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | MCB |
| 322 | 9 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140004 AUX. CONTACT 110V AC \"D1\" |
| 323 | 10 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140013 INDICATING LAMP 415V AC \"H1\" |
| 324 | 11 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140015 INDICATING LAMP 415V AC \"H5\" |
| 325 | 12 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140014 INDICATING LAMP 240V AC \"H6\" |
| 326 | 13 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140010 HRC FUSE BASE & LINK 2A |
| 327 | 14 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30140023 40/38A POWER CONTACTOR \"C1\" |
| 328 | 15 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | CONTACTOR AUC 1NO-1NC BCH |
| 329 | 16 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | TIME DELAY RELAY |
| 330 | 18 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30120094 BEARING DRIVING END 6310ZZ |
| 331 | 19 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30120095 BEARING NON-DRIVE END 6310ZZ |
| 332 | 20 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30120096 THRUST WASHER |
| 333 | 21 (MANDATORY SPARES ) STEERING GEAR MOTOR & CONTROL PANEL | 30120097 OIL SEAL |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail