Power Government Departments Closing in 0 days TDR #30237083

Creation Of 100 Kva Substation At Bilal Coloney Within The Jurisdiction Of Ediv Khanyar Creation Of 100 Kva Substation At Bilal Coloney Within The Jurisdiction Of Ediv Khanyar

Issued by Government Departments · ZAKURA, Jammu And Kashmir
Tender Value
8.29 Lakhs
Estimated cost
Bid Submission
04 Jan 2022
0 days left
EMD
16680
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ZAKURA → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Creation Of 100 Kva Substation At Bilal Coloney Within The Jurisdiction Of Ediv Khanyar Creation Of 100 Kva Substation At Bilal Coloney Within The Jurisdiction Of Ediv Khanyar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Dec-2021 1STEXTENSIONTO E NIT 66 Date 24-Dec-2021
2 26-Dec-2021 2nd extension to enit NO 66 Date 30-Dec-2021
3 31-Dec-2021 3rd extension to enit 66 Date 04-Jan-2022

BOQ

Name of Work:creation of 100 kva substation at Bilal coloney within the jurisdiction of EDIV Khanyar
Sl. No. Item Description
1Supply, installation, testing and commissioning of:
211/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, ( Al wound100 kVA, and with LV Cable Box having detachable Aluminium Gland plateapproved by the Department including earthing of Transformer along with fixing of flat iron strip to be fixed on earthling insulating boots of Sub Stations on two poles structure as per REC Standard F1,F2, F3 F4 &F10 (SITC) conditional Kindly read condtion No 11 of the SBD
311/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, ( Copper wound100 kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plateapproved by the Department including earthing of Transformer along with fixing of flat iron strip to be fixed on earthling insulating boots of Sub Stations on two poles structure as per REC Standard F1,F2, F3 F4 &F10 ( Transformer to be provided by thedepartment which is tobelifted from Diviisonal stores Khanyar) conditional Kindly read condtion No 11 of the SBD
49 mts steel tubular pole post 410 (SP-33) IS 2713 (part-II) 1990 as per REC Standard (SITC) conditional Kindly read condtion No 11 of the SBD
59 mts steel tubular pole post 410 (SP-33) IS 2713 (part-II) 1990 as per REC Standard( poles be provided by thedepartment which is to belifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
6GI Channel100x50x50x6 mm 9\" long (2 No) duly fabricated as per site requirement & as per REC Standard .
7GI Channelcross-arm (ISLC 75 designation)75x40x40x6 mm 9\" long (8No) duly fabricated as per site requirement& as per REC Standard .
8GI Channelcross-arm (ISLC 75 designation)75x40x40x6 mm 6\" long (2 No) duly fabricated as per site requirement& as per REC Standard .
9MS Angle iron braces (ISA 5050 designation) 50x50x6mm 6\" long (6 No) duly fabricated as per site requirement& as per REC Standard .
10Providing of Chemical Earthing of Sub-Station for neutral earthing 2 mtr long 50mm dia GI to copper with additional 1 length GI pipe 38mm connected with chemical earthing and with extension of GI strip 25*3mm upto all equipments.Earthing has been laid through insulators to avoid with the existing structure for LA.
11Galvanized Nuts & Bolts & washers of sorts. (Galavinsied as per IS-2633/1986)
12185mm² PVC single coreLT cableconnforming to IS 1554 (part -I) 1988 for incoming and outgoing circuits to be connected with LT Network including thimbling with 185 mm sq Al lugs
13Bimatellic Clamps19mm².
1411KV 400 AMP Gang Operated switch gear
15Drop-out set (Horn-gap type) as per REC standard F6
1611KV Lighting Arrester Set (Station type)as per REC standardconforming to IS 3070 part -III and as per REC standard
17LT fuse set
1811KV pinwithinsulatorsBrown glazed porcelain insulator confirming to IS-731/1971 Amendments 1 to 5 type B with 320mm minimum creepage distance and with lead/Zinc thimbles suitable for use with G.I forged pin having small steel heads as per IS-4l86 (P.I) 1993 and IS-2486 (P.II)1989 and revision with latest amendments if any as per REC Standard C-1
19Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
20Earthing Rods as per REC Standard (J-1) (Spiral Type)
21Earthing insulating boots
22Providing, Erection,testing & commissioning of MS Angle iron for Transformer Belt(ISA 5050 designation) 50x50x6mm 10\" long duly fabricated as per site requirement and painted with two coats of Red oxide and Al. Paint as per REC Standard
23GI wire for Anticlimbing Device as per REC Standard
24Sign Board
25Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.50 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700mm for 9 mtrs Long ST Poles (410, SP-33) (the leftover pit after concreting to be filled with soil and boulders)
26Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
27Supply, installation, testing and commissioning of:
289 mts steel tubular pole post 410 (SP-33) IS 2713 (part-II) 1990 as per REC Standard (SITC) conditional Kindly read condtion No 11 of the SBD
299 mts steel tubular pole post 410 (SP-33) IS 2713 (part-II) 1990 as per REC Standard( poles be provided by thedepartment which is to belifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
30GI Channelcross-arm 75x40x40x6 mm 9\" long (6No) duly fabricated as per site requirement& as per REC Standard .
31GI Angle iron braces50x50x6mm 6\" long (6No) duly fabricated as per site requirement and as per REC Standard
32Galvanized Nuts & Bolts & washers of sorts. (Galavinsied as per IS-2633/1986)
33Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
34Earthing Rods as per REC Standard (J-1) (Spiral Type)
3550 mm ²ACSR as per REC Standard. Conductor(Rabbit)IS 4826/1979 and laid as per REC standard (SITC) conditional Kindly read condtion No 11 of the SBD
3650 mm ²ACSR as per REC Standard. Conductor(Rabbit )IS 4826/1979 and laid as per REC standard ( Conductor be provided by thedepartment which is to belifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
37Pole clamps fabricated out ofMS channel
38Cement bottoming 1:2:4 mix as per REC standards 0.50 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700mm for 13/11/9 mtrs Long ST Poles (410, SP-33) (the leftover pit after concreting to be filled with soil and boulders)
39painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
40Supply, installation, testing and commissioning of:
418 Mtr. Long ST Poles (410 SP15) with pit excavation ( poles be provided by thedepartment which is to belifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
428 Mtr. Long ST Poles (410 SP15) with pit excavation ( poles be provided by thedepartment which is to belifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
4350 mm ²ACSR as per REC Standard. Conductor(Rabbit)IS 4826/1979 and laid as per REC standard (SITC) conditional Kindly read condtion No 11 of the SBD
4450 mm ²ACSR as per REC Standard. Conductor(Rabbit )IS 4826/1979 and laid as per REC standard ( Conductor be provided by thedepartment which is to belifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
45Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700mm for 8 mtrs Long ST Poles (410, SP-15) (the leftover pit after concreting to be filled with soil and boulders)
46pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to eachpole including supply and welding of GI channel 70x40x150 on pole for earth connection
47Galvanized Nuts and Bolts of sizes.
48painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
49LT Shackle insulators as per REC standard
50MukKI Clamps fibricated out of 50x8 mm flat iron of appropiate size and specification for holding LT Shackle insulators.

AI Tender Summary

OUR REF NO 30237083
AUTHORITY Government Departments
TENDER VALUE 8.29 Lakhs
LAST DATE 04-01-2022
Authority
Authority Name Power Development Department
Work Description Creation Of 100 Kva Substation At Bilal Coloney Within The Jurisdiction Of Ediv Khanyar Creation Of 100 Kva Substation At Bilal Coloney Within The Jurisdiction Of Ediv Khanyar
Basic Detail
Tender No EDIV/66 OF 2021
Bidding Type Tender
Location
City ZAKURA
State Jammu And Kashmir
Key Dates
Publish Date 31 Dec 2021
Submission Date 04 Jan 2022
Open Date 05 Jan 2022
Finance
Tender Value 8.29 Lakhs
Tender Fee 500
EMD 16680
Exemption Not Available
Document List
EARTHING2.pdf
FOUNDATION.pdf
HTFRAME.pdf
8c17f1a8-7c57-44cb-a7d2-cd603985efc5.html
11KVLINE.pdf
BOQ_336848.xls
EARTHING.pdf
LTLINE.pdf
PIPEEARTHING.pdf
sbd66.pdf
STAYARRANGMENT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 31, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 24, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 30, 2021
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 04, 2022
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 04, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 05, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

EARTHING2.pdf

pdf

FOUNDATION.pdf

pdf

HTFRAME.pdf

html

8c17f1a8-7c57-44cb-a7d2-cd603985efc5.html

pdf

11KVLINE.pdf

xls

BOQ_336848.xls

pdf

EARTHING.pdf

pdf

LTLINE.pdf

pdf

PIPEEARTHING.pdf

pdf

sbd66.pdf

pdf

STAYARRANGMENT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders