| 1 | FOR SHIFTING OF L.T. AND 11KV ELECTRICITY LINE AND OTHER ASSOCIATED WORKS, IN THE WAY OF GANGA EXPRESSWAY, IN DEPOSIT SCHEME, IN THE JURISDICTION OF EDD-I HAPUR, UNDER EDC., HAPUR. (All work will be done as per Sanctioned estimate) |
| 2 | Carriage of line material (like 11KV Cable Jointing Kit outdoor type, Striaght Through, clamps, channel, etc.) from Electricity Store Center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road. |
| 3 | Carriage of ST Pole 11 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road. |
| 4 | Carriage of PCC Pole 8.5 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road. |
| 5 | Carriage of 11KV XLPE Cable 3x185sqmm, from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road. |
| 6 | Carriage of LT Cable AL 3.5x400Sqmm, from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road. |
| 7 | Fabrication, erection and fixing of double pole on ST Pole 11 mtr. long with fixing of M.S. Top & Dropper Channel, M.S. S/S Angle, E-Bracket, 11 KV Pin insulator with Pin,Disc Insulator with Disc fitting as per RESPO Drawing/Norms by providing topand dropper clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. |
| 8 | Erection & Fixing of ST. Pole 11 mtr. longin LT line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. |
| 9 | Erection & Fixing of ST. Pole 11 mtr. longin 11 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. |
| 10 | Erection & fixing of PCC pole 8.5 mtr. in L.T. Line after digging of suitable pits including fixing of all accessories by providing L.T. Pin Clamp made of M.S. Flat of size 50x6mm & Shackle Insulator of size90x75 mm & proper size nuts and bolts as per RESPO Drawing/Norms. |
| 11 | Laying of 140mm HDPE pipe, for laying of underground 11 KV XLPE Cable as per RESPO/Norms, including cost of above HDPE pipe. |
| 12 | Laying of 11KV XLPE Cable undergound (Double Circuit) into HDPE Pipe, spare cable shall be left in the loop shape at both ends as per RESPO/Norms. |
| 13 | Laying of GI/HDPE pipe, for laying of underground LT Cable AL 3.5x400Sqmm, as per RESPO/Norms, including cost of above GI/HDPE pipe. |
| 14 | Laying of LT Cable AL 3.5x400Sqmm, undergound (Double Circuit) into GI/HDPE Pipe, spare cable shall be left in the loop shape at both ends as per RESPO/Norms. |
| 15 | Laying of 11KV XLPE Cable completion work properly according to sanctioned estimate as per RESPO/Norms |
| 16 | Laying ofLT Cable AL 3.5x400Sqmm completion work properly according to sanctioned estimate as per RESPO/Norms |
| 17 | Road restoration charge for foothpath side as per RESPO/Drawing Norms. |
| 18 | Making and filling of 11KV Cable Jointing Kit, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms. |
| 19 | Making and filling of 11 KV Straight through jointing kit, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms. |
| 20 | Providing & Fixing of G.I. pipe 6\"dia Class-B over 11KV 3X120Sq.mm XLPE cable before mounting the cable at double pole. The work includes fitting of clamps, sealing of top and bottom of pipe and one end of pipe is to be burried under earth about 500mm earch including mounting and clamping the cable on double pole structure and making connection with overhead line at both ends. |
| 21 | Laying, Stringing and final sagging of ACSR Rabbit Conductor after binding from Insulator, as per RESPO/Drawing Norms. |
| 22 | Removal of old & used ACSR Weasel Conductor from insulator and bundling of the same. |
| 23 | Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops. |
| 24 | Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts. |
| 25 | Grouting of PCC/ST supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials. |
| 26 | Wrapping of barbed wire on 11KV/LT ST/PCC poles as anti-climbing device for a length of 0.9mtrs. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a hieght of 2.75 mtr from the ground complete, including providing & fixing of lower end & upper end clamps made of M.S. Flat 40X5mm complete with nuts & bolts and all other required material and T&P. |
| 27 | Providing & Fixing of Danger Board, including fixing of all accessories by providing all required materials (like suitable clamps, nuts & bolts etc.) as per RESPO/Drawing Norms. |
| 28 | Providing & Fixing of Number Plate alongwith all required accessories (like suitable clamps, nuts & bolts etc.) as per RESPO/Drawing Norms. |
| 29 | Fabrication & Fixing of T-Channel on pole by providing Holding Clamps, F-Clamps & Proper size nuts & bolts, as per RESPO/Norms. |
| 30 | Fabrication of Guarding Angle X Arm & other requisites material for guarding by drawing 02Nos G.I Wire and making loop at suitable distance as per RESPO drawing/Norms by providing holding clamps, 02Nos. Eye bolts made of M.S. round size 12mm dia-100mm long & Cross Arm clamps made of M.S. Flat of size 50X6mm and bolts as per norms of RESPO Lucknow . |
| 31 | Providing & Fixing of LT PVC Spacers as per Norms. |
| 32 | Providing & Fixing of jointing sleeves for conductor as per Norms. |
| 33 | Marking of numbering with paint on PCC Pole including cost of paint etc. |
| 34 | Carriage of old & used ACSR Weasel Conductor (1620mtrs) from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road. |
| 35 | Jumpering work properly as per RESPO/Norms. |