Construction Morrah Buffalo Farm At Barnoh Distt. Una ( Hp ) . ( Sh- Providing Electrical Installation Thereof ) . ( Sh- Providing Electrical Installation Thereof ) ., Barnoh (una)-Himachal Pradesh

Himachal Pradesh State Industrial Development Corporation Limited-HPSIDC has published Construction Morrah Buffalo Farm At Barnoh Distt. Una ( Hp ) . ( Sh- Providing Electrical Installation Thereof ) . ( Sh- Providing Electrical Installation Thereof ) .. Submission Date for this Tender is 16-12-2021. Electrical Maintenance Tenders in Barnoh (una) Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30217470
Construction Morrah Buffalo Farm At Barnoh Distt. Una ( Hp ) . ( Sh- Providing Electrical Installation Thereof ) . ( Sh- Providing Electrical Installation Thereof ) .
Open Tender
Indian
Himachal Pradesh
Barnoh (una)
16-12-2021

Tender Details

Construction Morrah Buffalo Farm At Barnoh Distt. Una ( Hp ) . ( Sh- Providing Electrical Installation Thereof ) . ( Sh- Providing Electrical Installation Thereof ) .

Key Value

Document Fees
INR 1300 /-
EMD
INR 23200.0 /-
Tender Value
INR 11.56 Lakhs /-

BOQ Items

Name of Work: Construction ofMorrah Buffalo Breeding Farm at Barnoh Distt UnaH.P (SH- Providing Elect. Installtion thereof ).
Sl. No. Item Description
1Wiring for light point / fanpoint /exhaust fan /call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Group C.
2Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C.
3Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(i) 2x1.5 Sq. mm.
4(ii) 2x2.5 Sq. mm.
5(iii) 2x4.0 Sq. mm.
6(iv) 2x10 Sq. mm.
7Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover platefor modular switches in recess as required:-(i) 2 modules (78mmx78mmx50mm)
8(ii) 12 modules (205mmx135mmx60mm)
9Supplying and drawing LAN cable CAT 6E, solid copper conductorprotected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
10Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required. (i) 2 Pair
11Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-(i) 25 mm. dia
12Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. (i) S.P. 5/ 6 Amps one way Modular switch.
13(ii) 5 pin, 5/ 6 Amps Modular socket outlet.
14(iii) Telephone socket outlet, Modular.
15(iv)S.P. 15/ 16 Amps one way Modular switch.
16(v)6 pin,15/16 Amps Modular socket outlet.
17(vi) TV. Socket outlet, modular.
18Supplying and fixing stepped type Modular fan regulator on the existing modularbox including making connections etc. as required.
19Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
20Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
21Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
22Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
23Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
24Supplying and fixing copper strip bus-barssuitable for 200 Amp. 415 volts capacity4 No. each ofcross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required:-
25Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.(i) 160 Amp. -16 KA
26Supplyinganderection of 6amps. to 32 amps. rating, 10 KA breaking capacity, 240volts, "C" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(i) Single pole. Cat-A.
27Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) 40 Amps. Cat-A.
2863 Amps. Cat-A.
29Supplyinganderection of 40/50/63 amps rating, 10 KA breaking capacity, 240volts, "C" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(i) Double pole. Cat-A.
30Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) 63 Amps. Cat-A.
31Supplyingand fixingoffollowingway, singlepoleandneutral sheetsteel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-(i) Double door-8 way
32(ii)Double door-12 way
33(iii) Double door-16 way
34Earthing with G.Iearth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
35Extra for using salt and charcoal for pipe earth electrode complete as required.
36Providing and fixing 6 SWG (4 mm dia.) G.I.wire on surface or in recess for loop earthing as required.
37Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- (i) 10 Liter capacity water heater (Cat-A)
38(ii) 25 Liter capacity water heater (Cat-A)
39Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, Light duty,300 mm sweep
40Exhaust Fan, Heavy duty, 300 mm sweep in/c fan shutter if required
41Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to required length] with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan boxand earthing etc. as required:- (i) Ceiling Fan 1200 mm sweep, Category-A
42Ceiling Fan 1400 mm sweep, Category-A
43Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. (i) Fixed type wall bracket 150 dia, single lamp.(Category-A)
44Mirror light 610 mm, double lamp.(Category-A)
45Supplying and fixing of bulk head fittingof all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. (i) Bulk head fitting, CFL type (Category-A)
46Providing and laying of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning,and refilling the trench etc. of the required size:-(i) Armoured cable 6 sq. mm (twin core)
47Armoured cable 10 sq. mm (twin core)
48Armoured cable 50 sq. mm (3.5 core)
49Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts gradeon surface etc. of the required size:-(i)Armoured cable 4 sq. mm (twin core)
50(ii)Armoured cable 6 sq. mm (twin core)
51(iii) Armoured cable 10 sq. mm (twin core)
52(iv) Armoured cable 50 sq. mm (3.5 core)
53Supplying and erection offollowing depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall havecable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The cost includes cost ofCT,ammeter, voltmeter , selector swtiches LED Lamps in/ccost of Cu strips and required wires for eachpanel/sub panel and other items required at site to the best satisfaction of engineer in charge.Themanufacturer of panel is to be got approved before fabriction along with drg and is to befabricated for mounting of accessories as per the direction and approval of engineer in charge.(i) 300 mm deep (nominal)
54Supplying and erection of street light bracket made of G.I. pipe "A" class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:- 40 mm dia. G.I. pipe, heavy class
55Supplying and erection of 3 stepped steel tubular swaged and welded pole of suitable length and dia. to be fixed up to a required planting depth below G/L in a hole of excavation about 30 cm dia. and of suitable depth, to be filled in up to 15 cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a 180 mmx100 mmx 45 mm deep, glass filled Nylan F.R. grade box for housing a 16 Amp. MCB, the outer surface of the plinth to befinished with 1:3 cement plaster 6 mm thick, the fuse-box shall have a water tight cover, including painting of pole with two coats of approved color, brand and manufacture of paint over a priming coatcomplete in all respects as required:-(a). Overall length 7 meter, with planting depth 1.25 m, length of sections 4 m, 1.5m and 1.5m (bottom, middle and top respectively), outer dia and thickness of sections 127mmx4.5mm, 101.6mmx3.65mm and 76.1mmx3.25mm (bottom, middle and top respectively) with approximate weight 74 Kg.
56P/FFire extinguisher Water CO2 9 KG Type-IS-15683 as approved by Engineer -in -Charge
57P/FFire extinguisher CO2 4.5 KG Type-IS-15683 as approved by Engineer -in -Charge
58Providing & fixing LED street light fitting ln white colour with pressure die- cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection. As per CAT no. BRTFG 72 LED/White ) complete in all respect.The fitting is to be fixed on existing bracket mounted onpole/on wall including wiring etcas required as approved and directed by engineer in charge of Bajaj/ Philips/ Havells make.
59Providing & fixing surface/ recess mounted 12/ 15W LED fitting of Syska/Havells/Philips/ Bajaj make as required complete in all respect.(i) 9 Watt
60(ii) 15W
61Providing & fixing Skyluks efficient LED panel surface 4*1ft /2*2Ftof Bajaj /Syska Havells / Panasonic equivalent to Bajaj Code No. BZRSLL 36W GJI WH /NW complete in all respect fitting in ceiling as approved & directed by engineer in charge.
62Supplying & fixing SKYLUKS LED surface mounting fitting 1"*1" LED luminaire panel of Bajaj/Havells/Philips/Syska20 /24WH
63Providing & Fixing 30 W LED floodlight of Bajaj /Philips/Havells as per Bajaj CAT NO. BJFL 30W LED with suitable clamps complete in all respect of Bajaj/Philips/Havells as approved by engineer in charge.
64Providing &fixing LED Batten integrated LED channel aluminum heat sink body of Bajaj make having Bajaj/ Havells / Syska make as below20 Watt with aluminum heatb sink body:
65Providing and Fixing Turbo Force Wall Air Circulator Fan 600 mmconfirming to IS-2997-1964 OF Havell make double wall bearings oscillation up to 90 degree with suitable arrangementas approved by Engineer -in -Charge
66Supplying and fixing of reputed make Light Emitting Diode of following rating as required.7-15 Watt. (phillips/ syska/or equivlent make
67Providing and fixing Division Plate for Urinals 600mm x 300. Vitreous Chinaincluding carriage of material within all leads and lifts.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail