| 1 | E/M work |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, etc., not exceeding 10 Sqm on plan and laying of cables or pipes, not exceeding 1.5m in depth and getting out in soft/ soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed. |
| 4 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed. |
| 5 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down complete all as specified and directed.(Note: Thickness of sand cushioning after punning down will be measured and paid.) |
| 6 | Supply and laying wellburntsub class‘B’ (clay) bricks( designated 75) locally available best quality, laid dryin trenches forprotection of underground cable all as specified and directed. |
| 7 | Dismantling of unserviceable Steel tubular poles/struts, any size includingremoval from site complete all asdirected. |
| 8 | Supply and fixing in replacement ofsteel tubular swaged poles, type 410 SP 31 (Overall length 9.00 m) complete with cast iron base plate, finial taper plug, bolts, nuts screws and washers including painting two coats of black bituminous paint internally and externally up to planting depth and remaining external portion with two coats of aluminum paints over a coat of red oxide primer and writing pole Nos with white paint on black back groundcomplete all as specified and as directed. |
| 9 | M&L for PCC M-7.5 grade (Nominal mix) using 40mm graded crushed stone aggregate as in foundation of pole, protection of UG cable, concrete base, etccomplete all as specified and directed. |
| 10 | M&L for PCC M-10 grade (Nominal mix) using 20mm graded coarse stone aggregate in coping of pole, concrete base work, protection of cable complete all as specified and directed. |
| 11 | Taking up/down worn out/ damaged / unserviceable XLPE/ PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100V grade from trench/ duct/ pole/ wall/ pipes/ roof tops etc. complete all as specified and directed.(Note: Excavation & Earthwork will be measured & paid for separately) |
| 12 | Supply, laying, jointing, connecting & testing in replacement of LT UG cable XLPE insulated , PVCbedded , galvanised steel strip or wire armored, electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core ,laid in trenches / on poles / walls / in ducts / roof top etc. passing through pipes etc including jointing materials such as cable glands, lugs etc complete all as specified and as directed. |
| 13 | All as per serial item No. 12 above but for 10 Sqmm 4 Core. |
| 14 | All as per serial item No. 12 above but for 16 Sqmm 4 Core. |
| 15 | All as per serial item No. 12 above but for 25 Sqmm 4 Core. |
| 16 | All as per serial item No. 12 above but for 35 Sqmm 3.5 Core. |
| 17 | All as per serial item No. 12 above but for 50 Sqmm 3.5 Core. |
| 18 | All as per serial item No. 12 above but for 70 Sqmm 3.5 Core. |
| 19 | All as per serial item No. 12 above but for 95 Sqmm 3.5 Core |
| 20 | All as per serial item No. 12 above but for 120 Sqmm 3.5 Core. |
| 21 | All as per serial item No. 12 above but for 150 Sqmm 3.5 Core |
| 22 | All as per serial item No. 12 above but for 185 Sqmm 3.5 Core |
| 23 | All as per serial item No. 12 above but for 240 Sqmm 3.5 Core. |
| 24 | Supply and laying in replacement of GI tube light grade as in cable protection pipe including all fittings & taking down / taking out from trenchcomplete all as directed for the following sizes :- |
| 25 | (a) 25 mm bore |
| 26 | (b) 40 mm bore |
| 27 | (b) 80 mm bore |
| 28 | Dismantling of unserviceable worn out / weathered / damaged ACSR conductor, service feeder of any sizeand type from pole after disconnectingjumpers and insulator bindings complete all as specified and directed. |
| 29 | M&L for ACSR conductor of any size and type, maintaining standard sag including providing aluminum binding wire, aluminium jointing, jumpers etc on LT OH lines complete all as specified and directed |
| 30 | Material and labour for streching,tightening and restringing ofACSR conductorsof any size and type and GI continuous earth conductors of any size, maintaining standard sag including providing aluminium binding wire and fixing of GI conductor complete all as specified and as directed. |
| 31 | Dismantling rusted/damaged cross arm of MS channel or angle section frompole complete all as specified anddirected. |
| 32 | M & L for cross arms, bracing, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, drilling hole for bolts in any shape or sizewith welding, bending cold or hot including paintingtwo coats of aluminium paint over a coat of primercomplete all as specified and directed. (Confirming to Fe-209, Gde- E.165) |
| 33 | Dismantling damaged insulators of any type and any size complete all as directed. |
| 34 | S&F in replcement pin type porcelain insulator of size 100 mm height, 65mm dia, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut for 1100 volts grade complete all as specified as directed.(Make: BHEL/ Jaypuria Brothers/ Pactil/ Southern Insulators) |
| 35 | S&F in replcement shackle type insulator, porcelain, vitreous, white, brown or green, 75mm height 90mm dia for working pressure of 1100 voltsincluding galvanized steel straps of section 31x3mm, 12mm dia of bolts, washers and nutscomplete all as specified and directed.(Make: BHEL/ Jaypuria Brothers/ Pactil/ Southern Insulators) |
| 36 | Supply and fix in replcement loop type insulator, vitreous porcelain, white, brown or green small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as directed.(Make: BHEL/ Jaypuria Brothers/ Pactil/ Southern Insulators) |
| 37 | Material and labour for cuttingof road/ hard standingn exc 20cm widthandn exc 60cm in depth for laying ofcable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1to match with existing surfacecomplete all as specified and directed. |
| 38 | M&L for cleaning, scrapping, preparingof old painted steel tubular pole 9m long and applyingone coat of aluminium red oxide primer and two coat of aluminium paint to pole and accessories / fittings whatever fixed on pole including marking pole No on each pole with yellow SE paintwith 5cm large bold letters on black background of suitable size at a height of 2m above GL and painting 50mm wide coloured alternate strips of yellow and black with 2 coats of synthetic enamel paint upto aheight of 1.5m from coping of pole complete all as specified and directed. |
| 39 | Trimming/ cuttingofthetreebranches / busheswhichfallswithin aclear distance of 3 meterfromall sides from theLT over head conductor& within line of conductors,and shifting wasteto nearby waste depot & cleaning the area complete all as directed.(Note :-Tree branches/Bushes falling on both sides of OH lines per metre run of OH lines shall be measured forthepurpose ofpayment) |
| 40 | Taking down old unserviceable service cableincluding batten/suspending wires complete all as specify and as directed. |
| 41 | S&F Service wire PVC insulated and PVC sheathed stranded Aluminium conductor 10 sq mm 2 Core fixed to walls or suspended by insulating hanger not more than one meter apart including 4mm dia GI suspension wire and binding with 2mm dia new GI wire with reel insulatorcomplete all as specify and directed.. |
| 42 | Dismantling stay assembly complete all as specify and directed. |
| 43 | Material and labour for stay assembly 20 mm dia complete with accessories as shown in electrical plate No. 1 completeall as specified and directed.(Note : Loop type insulator, stay clamps, excavationand concrete shall be measured separately) |
| 44 | M&L in replcement for galvanized stay strand of size 7/3.15 mm complete all as specified and directed. |
| 45 | M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down old damaged plate complete all as specified and directed |
| 46 | M&L for LT line seperator (4 wire in a single seperator) on over head lines complete all as specified and directed. |
| 47 | M&L for earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GE earth strip of size 25 x 3mm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Transformer, DG sets, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 5 of MES schedule Part I and testing complete all as specified and as directed.(Note: GI Earthing strip upto 7.5m in lenght is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately) |
| 48 | S&F 25 x 3mm aluminium strip for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.complete all as specified and directed. |
| 49 | Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc completeall as specified and directed. |
| 50 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc completeall as specified and directed for following :- (Colour code to be followed) |
| 51 | One light/fan point controlled by one, one way switch |
| 52 | One socket outlet 5 Amps 5 pin on independent board |
| 53 | One socket outlet 5 Amps 5 pin on same board with other switches |
| 54 | All as per item No. 46 here in before but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed. |
| 55 | S&Fmodular switch piano, 6 Amps, single pole, one way complete all as specified and directed. |
| 56 | S&F modularsocket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. |
| 57 | Supply and fixing modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module. |
| 58 | S&F ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body. complete all as specified and directed. |
| 59 | M/Lmodular switch 16 Amps single pole one way,one module. |
| 60 | S&F modular white cover with frame for fixing of 12 module. complete all as specified and directed. |
| 61 | S&F modular white cover with frame for fixing of 8 module. complete all as specified and directed. |
| 62 | S&F modular white cover with frame for fixing of 3 module. |
| 63 | S&F blank spacer plate for single module. complete all as specified and directed. |
| 64 | S&F modular electronic fan regulator rotary stepped type 120W, 240V, single phase, two module and connecting up complete all as specified and directed. |
| 65 | Taking down LED tube light fitting kept in safe custody for refixing to its original position including provision of cable from ceiling rose or connected to light. complete all as specified and directed. |
| 66 | Refixing tube light fittings received from item No-65 here in before and connecting up including provision of cable from ceiling rose or connector to light.complete all as specified and directed. |
| 67 | Taking down ceiling/exhaust fan including dismantling all necessary electrical connections to facilitate repairs to ceiling/wall complete all as specified and directed. |
| 68 | Hanging only/ Refixing ceiling/exhaust fan removed under item Srl No 67 above and connecting upincluding provision of cable from ceiling rose or connector to fan complete all as specified and directed. |
| 69 | Supply & fixing in replacement LED flood light 100W,240V,50 Hz smart bright essential flood light is aesthetically designed flood light lighting luminair for as superior performance flood light with IP-65 protection complete including connecting and testing.complete all as specified and directed.. Make: Philips Cat No: BVP142 LED 100W CW FG GR PSU/Bajaj/Crompton/Havells |
| 70 | S&F building security light fitting new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 high power LED light 20 watt including suitable size of wall bracket and connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. (Make: Havells Endura Pearl Cat No. ENDURAPEARLSL20WLED757SASYTOPC or equivalent in Bajaj/Philips/Crompton) |
| 71 | Supply and fixing in replacement intergal LED aviation light comprising of aluminium housing with polycarbonate enclouser fitting new generation energy saving & environmental friendly long life versatile fixing arrangement including MS clamp or screw etcetc all as specified and directed. (Make- Bajaj Cat No BAGV 302 LED or equivalentPhilips/Crompton/Havells |