Repair Maintenance Of Dg Sets Amf Panel Lt Distribution Panels Refrigeration Air Conditioning Ac Pants Lift System With Allied Works Under Ge Narangi, GE Narangi-Assam

Military Engineer Services-MES has published Repair Maintenance Of Dg Sets Amf Panel Lt Distribution Panels Refrigeration Air Conditioning Ac Pants Lift System With Allied Works Under Ge Narangi. Submission Date for this Tender is 03-01-2022. Passenger Lift Tenders in GE Narangi Assam. Bidders can get complete Tender details and download the document.




Tender Notice

30203663
Corrigendum : Repair Maintenance Of Dg Sets Amf Panel Lt Distribution Panels Refrigeration Air Conditioning Ac Pants Lift System With Allied Works Under Ge Narangi
Open Tender
Indian
Assam
GE Narangi
03-01-2022

Tender Details

Repair Maintenance Of Dg Sets Amf Panel Lt Distribution Panels Refrigeration Air Conditioning Ac Pants Lift System With Allied Works Under Ge Narangi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-01-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 91000.0 /-
Tender Value
INR 45.50 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF DG SETS, AMF PANEL, LT DISTRIBUTION PANELS, REFRIGERATION, AIR CONDITIONING, AC PANTS, LIFT SYSTEM WITH ALLIED WORKS UNDER GE NARANGI
Sl. No. Item Description
1M&L for servicing ofthe FRP cooling tower by taking down the choked FRP Fills, segments, rusted structural supports, bolts and nuts and replacement of FRP fills, repair to FRP segments, cold water sumps by applying the FRP living as per the standards by applying FRP cheppeal strand FRP wats and polyster resig, resig base FRP putting renewal of whole FRP fills, rusted bolts and nuts, bookes nozzels, cleaning the cooling tower fan assembly.repairing of the grills of the cooling tower and also repair any kind of leakages from the cooling tower, renew the both end bearings, improve the insulation of motor, complete painting the cooling tower with resin contained watching colour and testing commissioning the cooling tower of the central AC plant of capacity 3 x 52TRcomplete all as directed. Note:- Cleaning of 02 Nos of Cooling tower shall be measured and paid as Each job.
2M&L for servicing ofthe FRP cooling tower by taking down the choked FRP Fills, segments, rusted structural supports, bolts and nuts and replacement of FRP fills, repair to FRP segments, cold water sumps by applying the FRP living as per the standards by applying FRP cheppeal strand FRP wats and polyster resig, resig base FRP putting renewal of whole FRP fills, rusted bolts and nuts, bookes nozzels, cleaning the cooling tower fan assembly.repairing of the grills of the cooling tower and also repair any kind of leakages from the cooling tower, renew the both end bearings, improve the insulation of motor, complete painting the cooling tower with resin contained watching colour and testing commissioning the cooling tower of the central AC plant of capacity 3 x 25.1TRcomplete all as directed. Note:- Cleaning of 02 Nos of Cooling tower shall be measured and paid as Each job.
3M&L for cleaning water sump of make up water of size 3 mtr x 3 mtr and 2.0 mtr deep, complete removingall mud and tree leaves also including cleaning all vegetation growth all around the tank complete all as specified and directed . Note:- Cleaning of 01 No of water sump at 14 FAD and 222 NBC each shall be measured and paid as Each job.
4M&L for complete flushing out the refrigerator system (chiller unit) consisting of 3 x 52 TR condenser, cooling coil refrigeration suction, discharges and liquid line with dry Nitrogen, removal of complete dirt, oil and carbon and cleaning of the whole systemcomplete all as directed. Note:- Cleaning of 03 Nos of Refrigerator unit (chiller unit) shall be measured and paid asEach job.
5M&L for complete flushing out the refrigerator system (chiller unit) consisting of 3 x 25.1 TR condenser, cooling coil refrigeration suction, discharges and liquid line with dry Nitrogen, removal of complete dirt, oil and carbon and cleaning of the whole systemcomplete all as directed. Note:- Cleaning of 03 Nos of Refrigerator unit (chiller unit) shall be measured and paid asEach job.
6M&L forcomplete servicing of the central type AC plant(3x52 TR) Air handling units, of chilled water type/direct expansion type by dismantling the units side panels, spraying the ducted scale removing agent, across the fins area, and spray the water with support of high pressure servicing pump till removal of complete scale deposite across the cooling coil, cleaning the complete AHU chamber, blower, fan casing condensete tray, filter section and complete painting the rusted metal surface of testing and commissioning the Air handling units, checking correcting the aligments of AHU motor and shaft, drive sets including renewal of AHU belts as per existing No and Qty and AHU motor complete servicing and greasing including replacement of bearingcomplete all as directed. Note:- Cleaning of 02 Nos of Air handling unit shall be measured and paid asEach job.
7M&L forcomplete servicing of the central type AC plant(3x25.1 TR) Air handling units, of chilled water type/direct expansion type by dismantling the units side panels, spraying the ducted scale removing agent, across the fins area, and spray the water with support of high pressure servicing pump till removal of complete scale deposite across the cooling coil, cleaning the complete AHU chamber, blower, fan casing condensete tray, filter section and complete painting the rusted metal surface of testing and commissioning the Air handling units, checking correcting the aligments of AHU motor and shaft, drive sets including renewal of AHU belts as per existing No and Qty and AHU motor complete servicing and greasing including replacement of bearingcomplete all as directed. Note:- Cleaning of 02 Nos of Air handling unit shall be measured and paid asEach job.
8M&L fordescaling of shell and tube condenser by circulating the dilutted RAC-III Organic compound at the appropriate ratio according to the scale deposite in side the copper tubes of the condenser, circulate the chemicals till removed the scale deposite, and opening the both and covers, and manually brushes the tubes by using nylon brushes, cleaning the end covers, degreasing the complete copper tubes end covers by circulating the caustic soda solution, and flushing through after boxing up the both end covers, the work including isolation the each condensers by dummy the inlet and outlet water pipes, renew all the end covers/inlet and outlet flanges rubber gaskets, rusted bolts nuts etc for chilled water type AHU (3x52.0 TR) capacity sheel and tube condensers and chillerscomplete all as directed. Note:- Cleaning of 03 Nos of Condeser unit shall be measured and paid as Each job.
9M&L fordescaling of shell and tube condenser by circulating the dilutted RAC-III Organic compound at the appropriate ratio according to the scale deposite in side the copper tubes of the condenser, circulate the chemicals till removed the scale deposite, and opening the both and covers, and manually brushes the tubes by using nylon brushes, cleaning the end covers, degreasing the complete copper tubes end covers by circulating the caustic soda solution, and flushing through after boxing up the both end covers, the work including isolation the each condensers by dummy the inlet and outlet water pipes, renew all the end covers/inlet and outlet flanges rubber gaskets, rusted bolts nuts etc for chilled water type AHU (3x25.1 TR) capacity sheel and tube condensers and chillerscomplete all as directed. Note:- Cleaning of 03 Nos of Condeser unit shall be measured and paid as Each job.
10S&F in repair fanbelt of blower motors (AHU) of Size A-39 complete all as directed.
11S&F in reapir fanbelt of blower motors (AHU) of Size B-43 complete all as directed.
12M&L for complete leak testing, rectification of leaks, by welding/brazing and pressure testing as per the standards and holding the pressure for 48 Hrs and observe for any pressure drop in the system complete all as directed.
13M&L for vacuumising and dehyderating the complete system and charging only the refrigerant and testing and commissioning the system, setting of all control safety devices complete all as directed.
14Supply only R-22 refrigerant gas complete all as directed.
15Supply only R407C refrigerant gas complete all as directed.
16Supply only Danfoss S-180 Oil for scroll compressor complete all as directed.
17M&L for complete servicing of the pump motor sets 7.5 HP by dismantling from the position, cleaning, greasing, including renewable of the bushes, both end ball bearings (make of bearing : NBC/SKF), gasket, gland packing/water seats, both end terminal re-assembling, in position connect to the circuit test and commissioning complete all asdirected.
18M&L for complete servicing of the pump motor sets 5 HP by dismantling from the position, cleaning, greasing, including renewable of the bushes, both end ball bearings (make of bearing : NBC/SKF), gasket, gland packing/water seats, both end terminal re-assembling, in position connect to the circuit test and commissioning complete all asdirected.
19M&L for complete servicing of the pump motor sets 3 HP by dismantling from the position, cleaning, greasing, including renewable of the bushes, both end ball bearings (make of bearing : NBC/SKF), gasket, gland packing/water seats, both end terminal re-assembling, in position connect to the circuit test and commissioning complete all asdirected.
20M&L for complete overhauling of pump motor sets of 7.5 HP by dismantling from the position and providing duming to the in and out flanges. Rewinding of the burnt motors as per the existing standard with new copper winding of existing gauge & size ,including renewing of the bushes, gland packing/water seats, terminal and complete painting after assembling, install in position connect to the circuit test and commissioning complete all asdirected.
21M&L for complete overhauling of pump motor sets of 5HP by dismantling from the position and providing duming to the in and out flanges. Rewinding of the burnt motors as per the existing standard with new copper winding of existing gauge & size ,including renewing of the bushes, gland packing/water seats, terminal and complete painting after assembling, install in position connect to the circuit test and commissioning complete all asdirected.
22M&L for complete overhauling of pump motor sets of 3 HP by dismantling from the position and providing duming to the in and out flanges. Rewinding of the burnt motors as per the existing standard with new copper winding of existing gauge & size ,including renewing of the bushes, gland packing/water seats, terminal and complete painting after assembling, install in position connect to the circuit test and commissioning complete all asdirected.
23S&F in repair butterfly valves with counter flanges of size 100 mm including bolts and nuts necessary cutting and welding and applying two coats of synthetic enamel painting over a coat of red oxide primerin welded portion, flanges complete all as directed.
24S&F in repair butterfly valves with counter flanges of size 80 mm including bolts and nuts necessary cutting and welding and applying two coats of synthetic enamel painting over a coat of red oxide primerin welded portion, flanges complete all as directed.
25S&F in repair NRV including necessary fixing accessories for 80 mm bore dia pipe complete all as directed.
26S&F in repair pressure safety valve of 350 psi rate to water cooled condenser complete all as directed.
27S&F scroll compressor having nominal cooling capacity of 38.6KW at 50 Hz can be operated on R407C, R134a, R404A refrigerant with discharge connection mounting torque 110 N-m for AC plant of capacity3 x 25.1 TR . Make Danfoss,Model SZ185S4RC all as specified an as directed by engineer-in-charge.
28S&F scroll compressor having nominalcooling capacity of 41.1 KW at 50 Hz operated on R-22 refrigerant with discharge connection torque 110 N-mhaving capacity3 x 52.1 TR. Make Danfoss Model SM185S4RC all as specified and as directed.
29S&F in repair power contactor of ML3, 40 Amp, 3 Pole with coil voltage of 240 V, 50Hz with 2 NO + 2NC auxillary contacts suitable for upto 10 HP starter complete all as directed. (Make : L&T/C&S/ Legrand/ Havells).
30S&F in repair single phase preventor of 240 V, 50 Hz suitable for upto 7.5 HP starter complete all as directed. (Make : L&T/C&S/ Legrand/ Havells).
31S&F in repair CT Coil of 240 V, 50Hz suitable for upto 7.5 HP starter complete all as directed. (Make : L&T/C&S/ Legrand/ Havells).
32S&F in repair electonic thermostatic switch type water pressure cut out switch including necessary wiring with sensors/micro processing panel and testing for smooth functioning complete all as directed.
33S&F in repair HRC switch fuse unit 3 pole, 415 volt, in Micro processor panel of AC plant complete all as directed.
34S&F fix in repair original electronic PCB (mother board) of microprocessor based control panel unit with micro computer control circuit display of Central type AC plantand testing for smooth functioning of AC plant complete all as directed as per manufacturer/OEM design. Make: Bluestar
35S&F in repair MCCB 4 pole, 250 Amps, 415 volt Icu=100% lcs complete all as directed.
36S&F in repair MCB TPN, 40-63 Amps, 415 volt complete all as directed.
37S&F in repair water temperature meter, square shape having range 0 to 50 degree Centigrade/0-120 degree farenhite provided in Central AC plants complete all as directed.
38S&F in repair water pressure gauge meter 100 mm dia, anologe type range 0-500 PSI or 0-10 kg/sq.cm including necessary rapair to leakage of water by replacing 15 mm dia water tube in U shape for fixing water pressure meter in vertical position with control valve connected to mains chilled/raw water pipe line 100 mm dia complete all as directed.
39Comprehensive maint/minor adjustment of of all landing gate & car gate, controller dressing, car cleaning, sensor reapir/replacement and controller cleaning, replacement of gear oil, adjustment of guide shoe holder, OSG pit clearance adjustment of electrically operated lift of capacity 1000 kgs, Speed 0.70m/sec, 2 floor/2 stop, collective down control type, 3 phase, V3F drive type, manual/auto door ACO installed at NBC storage shed of 222 ABOD complete all as directed by Engr-in-Charge. Make: ECE Pvt Ltd
40M&L for toping up gear oil as directed by Engr-in-charge.
41Dismantling of existing unserviceable feeder pillar box including all accessories and demolition of PCC foundation, supply, install, test and commission feeder pillar box of size 500mm x 600 x 300mmwith 2 mm thick CRCA sheet of CPRI approved with all necessary frame work with angle iron ofsize 40 mm x 40 mm x 5 mm thick protection provision and 04 Nos aluminium bus bar of 200 Amps for three phase and neutral duly PVC laminated, plate for fixing MCCB, DOL Starter, Isolators, MCB DP, opening for MCCB/MCB/Isolator knobs & internal connections with 3 x 16 Sqmm copper flexible cable for phase and 1 x 6 Sqmm copperflexible cable for neutral connection and all other connections to be done with 4 Sqmm copper cable including one Nos hinged door, front open, with locking arrangements, danger notice board duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including grouting the feeder pillar box in the existing location with necessary bolts, nuts, washer and PCC foundation(1:2:4) complete with the following accessories and complete all as specified and directed by the Engr-in-Charge. INCOMING (a) Aluminium Bus bar of 200 Amp current carrying capacity (TPN) including vitreous porcelain insulator - 04 Nos (b) MCCB 125 Amp, 4pole, 30KA, 415 volt - 01 No Make: L & T Cat No CM98065OOLO or equivalent approved make of Legrand (c)Voltmeter, three phase, class - 1, digital type -01 No Make : L&T Cat No. WDS301FEV00 or equivalent approved make of Legrand.
42(d)Amp meter, three phase, class - 1, digital type -01 No Make : L&T Cat No. WDS301FCA00 or equivalent approved make of Legrand. (e) LED Phase indicator lamp (RYB) of 415 Volt - 01 Set Make- L&T cat No EP3FAS020102 or equivalent approved make of Legrand (f)Current Transformer 60/5 - 03 Nos Make : Kappa/AE OUTGOING (a)Direct -on-line starter, 415 Volts, 50 Hz, 3 Phase, type MK-I, relay max. range 11 Amp - 18 Amp - 01 No Make : L&T Cat No SS96211 or equivalent approved make of Legrand. (b) Isolator 240/415 volts, 50 Hz, conforms to IS : 13947-3 & 60947-3:2001, 4 pole, 100 Amp - 01 No Make : L&T Cat No BF410000or equivalent approved make of Legrand. (c) MCB 63 Amp, "C" Series, 240/415 Volt, 50 Hz, breaking capacity 10 KA - 01 No Make : L&T Cat No BB30630C or equivalent approved make of Legrand.
43M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3½ core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
44M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
45M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 3 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
46S&F in repair Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm burieddirectly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etcRCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate)including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
47Material and Labour for ‘B’ check servicing of all as per manufacturer instructions, includingcost of following ‘B’ check spares and minor spares required for carrying out the check like nut, bolts, washers,gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolant in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolant from engine and near by spare parts of engine of make Cummins and Alternator make-Stamford and capacity 380 KVA, , complete including testing after repair for its smooth functioning :- (a)Lubricating oil filter - 01 No (b)Filter for Coolant- 01 No (c)Fuel filter- 02 Nos (d)Water Filter - 01 No (e)Minor spares and waste cotton for cleaning - 01 Kit Note :1.Quoted rate deemed to be included fuel filter kits and lubricating oil filter kits and minor spares required for check. 2.Engine oil, Coolant for radiator, distilled water and new air filter element shall be measured and paid separately under relevant items of this schedule.
48All as per item No 47 here-in- above but make of alternator and Engine is Kirloskar and capacity, 200 KVA,- 01 Set. (a)Lubricating oil filter - 02 Nos (b)Fuel filter - 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit
49All as per item No 47 here-in- above but make of alternator and Engine is Kirloskar and capacity, 160 KVA -01 Set. (a)Lubricating oil filter - 02 Nos (b)Fuel filter - 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit
50All as per item No 47 here-in- above but make of alternator and Engine is Kirloskar and capacity, 125 KVA installed at Filteration plant near "D" Block-01 Set. (a)Lubricating oil filter - 02 Nos (b)Fuel filter - 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit
51All as per item No 47 here-in- above but make of alternator and Engine is Kirloskar Bliss and capacity, 125 KVA installed at CPWD PH-01 Set. (a)Lubricating oil filter- 01 No (b)Fuel filter - 01 No (c)Minor spares and waste cotton for cleaning - 01 Kit
52All as per item No 47 here-in- above but make of alternator and Engine is Crompton Greves and capacity, 125 KVA installed at AC Plant (a)Lubricating oil filter- 01 No (b)Fuel filter- 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit
53All as per item No 47 here-in- above but make of alternator and Engine is Kirloskar Green and capacity 100 KVA, (a)lubricating oil filter- 02 Nos (b)Fuel filter kit Secondary Element - 01 No (c)Fuel filter kit primary Element- 01 No. (d)Minor spares and waste cotton for cleaning - 01 Kit
54All as per item No 47 here-in- above but make of Engine & Alternator is Kirloskar Blissand capacity 100 KVA, . (a)Lubricating oil filter- 01 No (b)Fuel filter- 01 No (c)Minor spares and waste cotton for cleaning - 01 Kit
55All as per item No 47 here-in- above but make of Engine is Kirloskar and Alternator make-Jyoti and capacity, 75 KVA (a)Lubricating oil filter- 01 No (b)Fuel filter- 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit
56All as per item No 47 here-in- above but make of Engine is Kirloskar and Alternator make-Jyoti and capacity, 75 KVA installed at Sub Area. (a)Lubricating oil filter- 01 No (b)Fuel filter - 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit
57All as per item No 47 here-in- above but make of alternator and Engine (4R1040) is Kirloskar and capacity, 62.5 KVA installed at Sewage treatment plant-01 Set . (a)Lubricating oil filter - 01 No (b)Fuel filter- 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit
58All as per item No 47 here-in- above but make of alternator and Engine (4R1040) is Kirloskar and capacity 50 KVA, (a)Lubricating oil filter - 01 No (b)Fuel filter kit- 01 No
59All as per item No 47 here-in- above but make of alternator and Engine is Kirloskar and capacity, 40 KVA installed at MAP CPWD Pump House-01 set. (a)Filter for lubricating oil - 01 No (b)Fuel filter kit- 01 No
60Supply only engine oil grade 20W40 against "B" check servicing and as per the capacity of engine model and as per manufacturers recommendation complete all as directed.
61Supply only coolantagainst "B" check servicing for radiator of water cooled engines of any make/capacity and as per manufacturers recommendation complete all as directed.
62Supply and topup / replace distilled water for battery or radiator of engine usedcomplete all as directed.
63M&L for replacement of unserviceable tachometer with electronic type tachometer of any capacity complete all as directed.
64Removing existing unserviceble battery and supply and fix lead acid battery maintenance free 12 volts 180AH as per cat part No FXPO-MHD1800 of make EXIDE Xpress fully charged complete all as directed.
65Removing existing unserviceble battery and supplied and fixed lead acid battery maintenance free 12 volts 130AH as per cat part No FXPO-MHD1300 of make EXIDE Xpress fully charged complete all as directed.
66Dismantling unserviceable battery charging dynamo from DG set of rating 1 x 12 / 2 x 12 Volts complete repairs and servicing including replacement of bushes, bearings, Carbon brushes, rectifiers, rewinding of field magnet coil / rotor armeture coils and any other minor parts required all as directed and fixing on engine including testing/commissioning complete for DG set having any capacity complete all as directed. Note :Replacement of rotor armature coil if required shall be measured and paid seperately.
67Replacement of rotor armature coil suitable for battery charging dynamo of DG set complete all as directed.
68Dismantling self starter of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt armature, rewinding of Fd coils, replacement of pinion gears etc, complete servicing and refixing after repair including testing/commissioning complete for DG Set any capacity complete all as directed. (Note : Quoted rate is exclusive of solenoid coil, armeture coil, and pinion gear. If this items are required, they will be measured and paid separately as supply only under relevant items.
69Supply only solenoid coil suitable for DG set self starter
70Supply only armeture coil complete with shaft suitable for DG set self starter
71Supply only pinion gear suitable for DG set self starter
72Dismantling old unserviceable battery charging dynamo of rating 12 volts and supply and fixing new battery charging dynamo same as per existing model suitable for fixing on DG set, 1500 rpmincluding testing after installation complete all as directed. Make-LUCAS or equivalent.
73Dismantling old unserviceable battery charging dynamo of rating 24 volts and supply and fixing new battery charging dynamo same as per existing model suitable for fixing on DG set, 1500 rpm including testing afterinstallation complete all as directed. Make-LUCAS or equivalent.
74Dismantling old unserviceable Self starter of Diesel engine and supply and fixing new self starter of working voltage 12 volt/24 Volt DC and same as per existing model suitable for fixing on engine set including testing afterinstallation complete all as directed.
75M & L for Removing existing defective wiring of DG set AMF panel, rewiring with multistranded single core PVC insulated copper conductor wire, 2.5 sqmm for AC/DC supply connections to all control system and devices and testing of AMFpanel afterrepair complete all as directed. Note : Unserviceable spare like power contactor, auxilary contactor, Digital meters, relays, indication lamps, rotary selector switches etc shall be measured and paid separately as supply only under relevant items. Note :PVC insulated copper conductor wire, 2.5 sqmm for AC/DC supply connections is deemed to be included in quoted rate.
76Supply onlyMCB SP 6 to 32 A, 240V,50Hz, C series breaking capacity 10kA all as specified and directed.
77Supply only power contactor 4 pole, 415 volt, AC1 rating 250 Amps suitable for AMF panel board. Make: L & T /C&S/Havells
78Supply only power contactor 4 pole, 415 volt, AC1 rating160 Amps suitable for AMF panel board. Make: L & T /C&S/Havells
79Supply only power contactor 4 pole, 415 volt, AC1 rating 100Amps suitable for AMF panel board. Make : L & T /C&S/Havells
80Supply only spare coil suitable for power contactor 4 pole, 415 volt, 250 Amps for AMF panel board. Make: Schneider/Standards/Havells/C&S/HAGER
81Supply only spare coil suitable for power contactor 4 pole, 415 volt, 160 Amps for AMF panel board. Make: Schneider/Standards/Havells/C&S/HAGER
82Supply only spare coil suitable for power contactor 4 pole, 415 volt, 100 Amps for AMF panel board. Make: Schneider/Standards/Havells/C&S/HAGER
83Supply only EC2 AMF logic relays, suitable for DG set AMF panel board. Make: CSPC/Schneider/Standards/Havells/C&S/ HAGER
84Supply only overload relay suitable for AMF/LT panel board.
85Supply only SMPS automatic battery charger 12 volt suitable for DG set AMF panel board.
86Supply only SMPS automatic battery charger 24 volt suitable for DG set AMF panel board.
87Supply only multifunctionmeter flush mounting accuracy class 1.0in AMF panel .
88Supply only Air filter element suitable for DG set Engine of make Cummins and capacity380 KVA installed atABW.
89Supply only Air filter elementsuitable for DG set Engine of make Kirloskar and capacity200 KVA installed atABOD.
90Supply only Air filter elementsuitable for DG set Engine of make Kirloskar and capacity160 KVA installed atABOD NBC Shed and at FAD Adm DG Set.
91Supply only Air filter elementsuitable for DG set Engine of make Kirloskar and capacity125 KVA installed at Filteration plant-01 Set
92Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 125 KVA installed at CPWD P/House-01 Set.
93Supply only Air filter elementinner and outer suitable for DG set Engine of make Crompton Greaves and capacity 125 KVA installed at AC Plant FAD Depot 01 Set.
94Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 100 KVA installed at Singal Centre-01 Set
95Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 100 KVA installed at FAD depo-01 Set & Veh-01 Set
96Supply only Air filter elementsuitable for DG set Engine of make Kirloskar and capacity 75 KVA installed at Sub Area-01 Set and New Filter plant-01 Set.
97Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity62.5 KVA installed at Sewage Treatment plant
98Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity62.5 KVA installed at ABOD Depot Area.
99Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity50 KVA installed atOffice.
100Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 40 KVA installed at CPWD Pump House.
101Supply and fix in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set380 KVA of Engine make Cummins installed atABW.
102Supply and fix in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set 1 x 200 KVA of Engine make Kirloskar installed atABOD.
103Supply and fix in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt,and (c) water pump belt all suitable for DG set 160 KVA of Engine make Kirloskar installed at FAD Adm Area/Security lights - 01 Set, NBC ShedABOD - 01 Set
104Supply and fix in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set 3 x 125 KVA of Engine make Kirloskar/ Cummins/ CG installed atFilteration plant-01 Set and CPWD P/House-01 Set and AC PlantFAD Depot -01 Set
105Supply and fix in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynamo belt,and (c) water pump belt all suitable for DG set 1 x 100 KVA of Engine make Kirloskar installed at Signal Centre
106Supply and fix in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt,and (c) water pump belt all suitable for DG set 1 x 100 KVA of Engine make Kirloskar installed atFAD Depo & Veh
107Supply and in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set75 KVA of engine make Kirloskar installed atSub Area-01 Set, and Hav Pump House-01 Set.
108Supply and fix in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt,and (c) water pump belt all suitable for DG set62.5 KVA of engine make Kirloskar installed at Sewage Treatment plant andABOD Depot Area
109Supply and fix in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set 1 x 50 KVA of engine make Kirloskar installed at GE Office.
110Supply and in repair "V" belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set 1 x 40 KVA of engine make Kirloskar installed at CPWD Pump house.
111M&L for draining out coolant water from radiator, dismantling radiator, repair of radiator for leakage if any, cleaning the radiator set with dilute Hydro Chloric Acid, kerosene, fresh water and refixing the same with new rubber hose with clamps filling with coolant with distilled water and checking for its proper function on DG set all as directed and specified. Note : Coolant and distilled water shall be measured and paid separately under relavant items.
112M&L for dismantling the unserviceable FIP from DG set engine and taking it to reputed workshop for cleaning, overhauling/servicing and calibration with prescribed overhauling kit of any capacity DG set with replacement of unserviceable parts/spares as required for repair of injectors, re-fixing the FIP and checking the same for its smooth functioning on DG set complete all as directed.
113Labour only for attending breakdowns of DG sets/AMF panels through skilled technician from reputed service centre of DG sets with necessary tool kits, checking Engine and alternator for defects, carryout necessary repairs works to rectify the defects without major overhauling/opening of Engine or Alternators, replace of external spare to repair/rectify the defects and testing DG set for its smooth functioning on full load complete all asdirected. Note :1.Necessary spares required to rectify the defects shall be measured and paid separately as supply only under relavant items. 2.The complaint shall be attended and rectifed within 24 hours from time of reporting by Engr-in-Charge or his authorised representative. 3. Any Major defects shall be reported on priority to Engr-in-Charge to avoid undue delay in fuctioning of installation.
114Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 40 KVA to 75 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed.
115Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 100 KVA to 200 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed.
116Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity 380 KVA and above all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed.
117S&F MCCB with Thermal - magnetic release of 80-100 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories and taking down old unserviceable one. Make: L & T Cat Part No. CM91712OOKOOG or equivalent inSiemens/ ABB
118S&F MCCB with Thermal - magnetic release of 200-250 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories and taking down old unserviceable one. Make: L & T Cat Part No. CM90642OOPO or equivalent inABB/ Siemens
119S&F MCCB with Thermal - magnetic release of 125-160 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories and taking down old unserviceable one. Make: L & T Cat Part No. CM90642OOMO or equivalent inABB/Siemens
120Supply and fix in repair ON LOAD change over switch, 4 pole, 415 Volts, 200 Amps capacityopen execution typecomplete all as directed.
121Repairs to injector including cleaning of nozzels complete all as directed.
122Repairs to cylinder head complete all as directed.
123Repairs to turbo charger complete all as directed.
124Cleaning of DG set fuel tank of capacity upto 100 KVA by draining out residual oil and removal of sludge from bottom of the tank complete all as directed.
125Cleaning of DG set fuel tank of capacity exceeding 100 KVAbut not exceeding 200 KVA by draining out residual oil and removal of sludge from bottom of the tank complete all as directed.
126Cleaning of DG set fuel tank of capacity exceeding 200 KVAbut not exceeding 400 KVA by draining out residual oil and removal of sludge from bottom of the tank complete all as directed.
127Supply only fly wheel ringgear suitable for upto 100 KVA DG set.
128Supply only fly wheel ringgear suitable for 125 KVA upto 200 KVA DG set.
129Supply only fly wheel ringgear suitable for380KVA DG set.
130Repairs to automatic voltage regulator (AVR) including replacement of electronic printed circuit board (PCB) and wire connections of alternator of any capacity complete all as specified and directed.
131S&F in repairs solenoid switch with fuel shut off valve compatible to auto mainsfailure panel for remote operation complete all as specified and directed.
132S&F in repairs battery terminal leads of 2AWG (35sqmm) copper wire single core PVC insulated 1.5m long of colour coding red or black complete withbrass terminals fixed at site with petroleum jelly complete all as specified and directed.
133S&F in repair centrifugal gear driven,Cast iron body water pump assembly suiatable for 380 KVACUMMINS Diesel Engine Cooling system complete all as specified and directed.
134S&F in repair centrifugal gear driven,Cast iron body watxer pump assembly suiatable for 100 KVAKirloskar Diesel Engine Cooling system complete all as specified and directed.
135Supply and fix in repairMCB TP 25 to 63 A, 415V,50Hz, C series breaking capacity 10kA all as specified and directed.
136Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity complete all as specified and as directed by the Engr-in-Charge.
137S&F in repair heating element of 2.0 KW (Round or Triangular Head as required at site)cluding rubber washer (ISI marked) etc complete all as directed
138S&F in repair 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as directed.
139S&F in repair 600 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as directed.
140S&F in repair thermostat suitable for 25 ltr capacity Gyesers complete all as directed.
141S&F in repairthermostat suitable for 50 ltr capacity Gyesers complete all as directed.
142S&F in repair indicator bulb for geyser (Red & green) complete all as directed.
143S&F in repair geyser base plate assembly including rubber washer suitable for 25 ltr capacity Gyesers complete all as directed.
144S&F in repair geyser base plate assembly including rubber washer suitable for 50 ltr capacity Gyesers complete all as directed.
145S&F in repair glass wool sheet of size 8x4 Sqmm for insulation of 25/50 Ltrs capacity geyser, water cooler, Deep freezer etc complete all as directed.
146S&F in repair plug top 3 pin 15 ampsISI marked complete all as directed.
147M&L for wall fastener of size 100 mm long, 8mm dia with double washers grouting making good in walls cementmortar (1:4) for fixing water heater, spilit AC outdoor after removing the existingunserviceable nuts /bolts and washers complete all as specified and directed.
148S&F in repair sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity exc.180 and n.exc 310 ltrs including sealing of the compressor with welding after assembling complete all as directed.
149S&F in repair sealed unit compressor suitable forRefrigarator/Deep Freezer capacity upto 180 ltrs including sealing of the compressor with welding after assembling complete all as directed.
150S&F in repair relay suitable for Refrigarator/ Deep Freezer of capacity upto 310 ltrs capacity complete all as specified and directed.
151S&F in repair Condenser coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed.
152S&F in repair fan motor suitable for Refrigarator/ Deep Freezerof capacity upto 310 ltrs of existing make complete all as specified and directed.
153S&F in repair door rubber gasket complete suitable for refrigerator upto 310 ltrs capacity all as specified and directed.
154S&F in repair thermostatic switch ofsuitable for Refrigarator/Deep Freezer upto 310 ltrs capacity all as specified and directed.
155S&F in repair filter stainer ofsuitable for Refrigarator/Deep Freezer upto 310 ltrs capacity all as specified and directed.
156S&F in repair cabinet lamp with holder and push switch including replacement of electric wires for Refrigerator upto 310 Ltrs capacity complete all as specified and directed.
157Supply and fix in repair ice chamber cabinet of Refrigerator of capacity upto 310 ltrs complete all as specified and directed.
158M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-134a as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried outin the presence of Engineer in Charge and certificate in this regard will be attached with the FB complete all as directed.
159M&L for servicing only in situ of Split typeair conditioner 1.5/2.0 Ton capacity after removing electric wire connection& cleaning of Cooling coil, Filter, etc. including testing to cooling complete to entire satisfaction of Engr-in-Charge.
160M&L for servicing only in situ of window typeair conditioner 1.5/2.0 Ton capacity after removing electric wire connection& cleaning of Cooling coil, Filter, etc. including testing to cooling complete to entire satisfaction of Engr-in-Charge.
161Dismantling of Split type/Window Type air conditioner 1.5 ton capacity after removing indoor outdoor copper tube connection, electric wire connection and transporting to authorised workshopfor reapir/replacement of compressor, cleaning of Cooling coil, condenser coil, fan motor, with and including filling of refrigerant R-22/R32 etc. and re-installing the same after complete repairs and testing of full load in presence of Engineer in Charge complete all as specified and directed . Note:- Sealed compressor will bemeasured and paid separately as supply only under appropriate items here-in-after. The permision of Engr-in-Charge shall be taken in writting before replacement.
162Dismantling of Split type/Window Type air conditioner 2 ton capacity after removing indoor outdoor copper tube connection, electric wire connection and transporting to authorised workshopfor reapir/replacement of compressor, cleaning of Cooling coil, condenser coil, fan motor, with and including filling of refrigerant R-22/R32 etc. and re-installing the same after complete repairs and testing of full load in presence of Engineer in Charge complete all as specified and directed . Note:- Sealed compressor will bemeasured and paid separately as supply only under appropriate items here-in-after. The permision of Engr-in-Charge shall be taken in writting before replacement.
163Supply only sealed compressorincluding sealing of the compressor with welding after assembling for 1.5 Ton Capacity Spilit type AC/ Window type AC complete all as specified and directed.
164Supply only sealed compressorincluding sealing of the compressor with welding after assembling for 2.0 Ton Capacity Spilittype AC/window type AC complete all as specified and directed.
165S&F in repair running capacitor 45 MFD for window type/Split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
166S&F in repair starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and directed.
167S&F in repair box type relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
168S&F in repair condencer coil unit complete for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
169S&F in repair capilary tube suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
170S&F in repair filter unit suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
171S&F in repair swingmotor suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
172S&F in repair roller with motor of indoor unit of split type A/C 1.5/2.0 Ton capacity all as specified and directed.
173S&F in repair fan blade with blower motor of window/split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
174S&F in repair control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC including inverter type complete all as specified and directed.
175S&F in repair control circuit (PCB) with remote device suitable for 1.5/2.0 Ton window type AC complete all as specified and directed.
176S&F in repair copper tube of size 1/2"" dia for connection of indoor and outdoor unit of split AC all per directed by the Engineer-in-Charge.
177S&F in repair copper tube of size 1/4"" dia for connection of indoor and outdoor unit of split AC all per directed by the Engineer-in-Charge.
178S&F in repair insulation coverof size 5/8" for insulating copper tube of split type AC all per directed by the Engineer-in-Charge.
179S&F in repair of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC all as directed by the Engineer-in-Charge.
180S&F in repair FRLSH copper cable cord flexible 3 core PVC insulated and overall PVC sheathed of size 1.5 sqmm for making connection of AC/Geysers/Water coolers/Refrigerator etccomplete all as specified and as directed.
181M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-22/R-32/R413 as required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried outin the presence of Engineer in Charge complete all as directed.
182M&L for Shifting Split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Re installed the same to new location after necessary servicing including testing and commisioning complete all as directed.
183M&L for Shifting window type AC 1.5/2.0 TR capacity including making good the disturbed surfaces of wall/floor including making of necessary staging and wooden frame complete all as directed.
184S&F in repair AC support bracket of size 500x500 mm ("L" Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed.
185S&F in repair Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 volts capacity and tested on completion complete all as specified and directed.
186S&F in repair Miniature Circuit Breaker (MCB) SP 5 to 32 Amps rating 240V, 10KA "C" Curve complete all as directed.
187S&F in repair Miniature Circuit Breaker (MCB) SPN 32 Amps rating 240V, 10KA "C" Curve complete all as directed.
188Dismantling of 40 Ltrs cooling capacity 80Ltrs storage type water cooler of sealed compressor 1/3HP capacityby cutting of refrigerant pipe, removing sealed unit compressor and blower motor/refrigerationsystem, Dismantling of refrigeration system with carbon tetra chloride, replacement of the chocked capillary tubes, strainer and dryer of required size, Cleaning and lubrication of blower motor and replacement of unserviceable noshing of shaft and assembling complete including Re-assembling all the components of water cooler in proper position including chargingrefrigerant gasas required, Leak testing of complete refrigeration system and testing the water cooler with cooling effects after installation in original position complete all as directed. (Note : Spare parts/components as required shall be measured and paid separately under relevant items here-in-after as supply only)
189Dismantling of 150 Ltrs cooling capacity 80Ltrs storage type water cooler of sealed compressor 1/2HP capacityby cutting of refrigerant pipe, removing sealed unit compressor and blower motor/refrigerationsystem, Dismantling of refrigeration system with carbon tetra chloride, replacement of the chocked capillary tubes, strainer and dryer of required size, Cleaning and lubrication of blower motor and replacement of unserviceable noshing of shaft and assembling complete including Re-assembling all the components of water cooler in proper position including chargingrefrigerant gasas required, Leak testing of complete refrigeration system and testing the water cooler with cooling effects after installation in original position complete all as directed. (Note : Spare parts/components as required shall be measured and paid separately under relevant items here-in-after as supply only)
190Supply & Fix compressor 1/3 HP capacity all as specified and directed.
191Supply only compressor 1/2 HP capacity all as specified and directed.
192S&F in repair relay with overload protector for water coolers of 40/150 ltrs capacity all as specified and directed.
193S&F in repair thermostatic switch for water coolers 40/150 ltrs capacity all as specified and directed.
194S&F in repair float valve assembly complete for water cooler 40/150 ltrs capacity water storage type all as specified and directed.
195S&F in repair capacitor 4 to 12 MFD of blower for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed.
196S&F in repair tap chromium plated suitable for water cooler all as specified and directed.
197S&F in repair blower motor of capacity 1/3 HP suitable for 40/150 ltrs capacity water cooler all as specified and directed.
198S&F in repair 4 KVA voltage stablizer suitable for 1.5 TR spilt / Window AC all as specified and as direced by engineer-in-charge. Make: V Guard/Vertex
199S&F in repair 5 KVA voltage stablizer suitable for 2 TR spilt / Window AC all as specified and as direced by engineer-in-charge. Make: V Guard/Vertex
Disclaimer :