Construction Of Rcc Bridge Over Raima River On Gandacherra - Raishyabari Road At Ch. 19.32 Km ( 2Nd Call )
Tender Value
3.39 Crore
Estimated cost
Bid Submission
28 Dec 2021
0 days left
EMD
3.39 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gandacherra → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Rcc Bridge Over Raima River On Gandacherra - Raishyabari Road At Ch. 19.32 Km ( 2Nd Call )
BOQ
| Sl. No. | Item Description |
| 1 | Sub Head-I (Construction of Foundation & Sub structure) |
| 2 | Excavation for StructuresEarth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work as per MoRT&HTechnical Specification clauses of section 300.Ordinary SoilA. By Manual Means |
| 3 | Upto 3 m depth |
| 4 | Levelling Course for Pile capProviding and laying of PCC M15 levelling course 100 mm thick below the pile cap. (including centering, shuttering, staging etc. but excluding reinforcement ) |
| 5 | Case - I : Using Concrete Mixer |
| 6 | Reinforced cement concrete in pile cap complete as per drawings & MoRT&H technical specifications Clauses 1100, 1500, 1700.(including centering shuttering, staging etc. but excluding reinforcement) |
| 7 | RCC Grade M 35 Case - I : Using Concrete Mixer |
| 8 | Supplying, fitting & placingThermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in foundation complete as per drawings & MoRT&H technical specifications Clauses 1600. |
| 9 | Bored Cast-in-Situ M-35 grade RCC pile excluding reinforcement complete as per Detailed Drawing & MoRT&H technical specifications Clauses 1100,1700 and removal of excavated earth with all lifts and lead upto 1000 m. B. 1000 mm dia |
| 10 | Plain/reinforced cement concrete in substructure complete including formwork as per drawings &MoRT&H technical specification Clauses 1500, 1700, 2200. (including centering, shuttering, staging etc. but excluding reinforcement) RCC M 35 Grade (Case - I : Using Concrete Mixer) |
| 11 | b) height from 5 m to 10 m |
| 12 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in substructure complete as per drawings & MoRT&H technical specificationClauses 1600, 2200. |
| 13 | Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 Kg/cm2pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRT&H technical specification clauses 2706, 2200. |
| 14 | Backfilling behind abutment, wing wall & return wall complete as per drawings, clause 710.1.4 of IRC:78 &MoRT&H technical specification Clause 2200.ii) Sandy material |
| 15 | Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRT&H technical specification clause 2504.2.2 |
| 16 | Pile load test on single vertical pile in accordance with IS : 2911 (Part - IV) |
| 17 | a) Initial and routine load test |
| 18 | b) Lateral load test |
| 19 | Sub Head-II (Construction ofSuperstructure) |
| 20 | Plain/ Reinforced cement concrete in superstructure including all formworks required as per drawings & MoRT&H technical specifications Clauses 1500, 1700, 2100. (including centering, shuttering, staging etc. but excluding reinforcement)RCC Grade M 35 Case - I : Using Concrete Mixerb. Height 5 m to 10 m |
| 21 | For T-beam & slab superstructure |
| 22 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed stee bar reinforcement in superstructure complete as per drawings & MoRT&H technical specificationClauses 1600. |
| 23 | Providing and placing in position drainage Spouts complete as per drawing (SD/205) and MoRT&H Technical Specification Clause 515, 2705. |
| 24 | Painting on concrete surfaceProviding and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm as per drawings and MoRT&H Technical Specification Clause 800. |
| 25 | Construction of precast RCC railing of M 30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings (No. SD / 202), including all formworks required and MoRT&H Technical Specification Clause 2703, 1500, 1600, 1700. (including centering, shuttering, staging etc. and reinforcement) |
| 26 | Providing and laying Cement concrete wearing coat M-30 grade including all formworks & required reinforcement complete as per drawings & MoRT&H technical specificationClauses 2702.(including centering, shuttering, staging etc. but excluding reinforcement) |
| 27 | PCC M15 Grade leveling course below approach slab complete including all formworks required as per drawings and MoRT&H Technical Specification Clause 2700. |
| 28 | Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawings and MoRT&H Technical Specification Clause 2704, 1500, 1600, 1700.RCC M 30 Grade |
| 29 | Strip Seal Expansion JointProviding and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/ supplier or their authorised representative ensuring compliance to the manufacturer\"s instructions for installation as per drawings and MoRT&H Technical Specification Clause 2607. |
| 30 | Providing and laying reinforced cement concrete in superstructure in footpath slab at all heights including all formworks required as per drawings & MoRT&H technical specifications Clauses 1500, 1700, 2100. |
| 31 | RCC Grade M 20 Case - I : Using Concrete Mixer |
AI Tender Summary
Tender Timeline
Dec 08, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedDec 28, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 28, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender