Military Engineer Services-MES has published Repair And Maint Of Ceiling Fans, Air Circulators, Exhaust Repair And Maint Of Ceiling Fans, Air Circulators, Exhaust Fans, Geyser And Solar Water Heater Under Ge ( S ) Jaipur. Submission Date for this Tender is 27-12-2021. Solar Heater Tenders in GE (S) Jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Taking down carefully existing storage type Geyser 25/50 litres capacity for repair complete overhauling including cleaning of geyser assembly inlet outlet pipe etc and re-fixing in position all as directed by Engineer-in-Charge. |
2 | Cleaning and preparation of outer surface of Geysers 25/50 litres capacity and painting with two coats of white synthetic enamel paint as directed by Engineer-in-Charge. |
3 | M&L for opening of geyser in position for carry out minor repair such as loose connection testing of thermostat, heating element, tightening of screws, PVC connection etc. Note :- Any item required in measured and replacement shall be paid for separately as under :- |
4 | S&F in repair Stainless steel inner tank of capacity 25 Ltr. |
5 | S&F in repair Stainless steel tank of capacity 50 Ltr. |
6 | S&F Glass wool/ rock wool for thermal insulation. |
7 | S & F Outer tank madeof MS sheet powder coated suitable for 50 Ltrs. |
8 | S & F Outer tank made of MS Sheet powder coated suitable for 25 Ltrs. |
9 | Dismantling of bottom assemble and de-scaling with acid and wire mess brush cleaning and refixing the same. |
10 | M & L PVC insulated and over all PVC sheathed copper conductorwire of size 2.5 Sqmm x 3 core, Lead wire with 15 A Top Plug heavy duty, ISI marked.Make : Havell’s/ Gloster/ NICCO |
11 | M & L Plug top 3 pin, 15 Amp rating ISI Make : Anchor/ SSK. |
12 | Replacement of heating element of capacity 1.5 KW ISI fixed in repair. Make: Bajaj or same make which is to be replaced |
13 | Replacement of heating element of capacity 2 KW ISI fixed in repair. Make: Bajaj or same make which is to be replaced |
14 | Replacement of heating element of capacity 1.5 KW having 115mm dia base with 6 hole with diaphram washer suitable for geyser 25 litre capacity Make venus |
15 | Replacement of heating element Clip on made of copper, capacity 2 KW ISI fixed in repair. Make: Bajaj or same make which is to be replaced |
16 | Replacement of Geyser bottom assemblyof 7 hole/9 Hole/6 hole as per existing complete including, bolts and rubber gasket for 25/50 litres capacity Geysers as per requirement with the same make which is to be replaced. |
17 | M&L for Pressure release safety valve for Geysers spring loaded suitable for 15mm pipe chromium plated. |
18 | M&L for replacement of thermostat ISI marked of any make/ capacity of geyser. |
19 | M&L for replacement of thermostat ISI marked suitable for geyser venus T105 type TBS 16 A 250 Volt |
20 | M&L for replacement of thermostat ISI marked suitable for geyser make Bajaj or same make which is to be replaced having 2 male terminals and round base |
21 | Replacement of neon indicator lamp round or rectangular type. |
22 | M&L for replacement of PVC flexible connection hot and cold, high strength, impeccable finish, corrosion resistance 450mm long for geyser |
23 | M&L for replacement of PVC flexible connectionhot and cold, high strength, impeccable finish, corrosion resistance 600mm long for geyser |
24 | S&F repair tubes 15mm bore medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floors. |
25 | S&F in reapir Angle stop valve of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-90gms) all as spacified and directed. |
26 | S&Fix in reapir Bib taps , cast copper alloy with crutch of butter fly handle screwed down , screwed for iron pipe or for brass ferrule, fancy type and fixed of size 15 mm dia complete all as spacified and directed. |
27 | Disconnecting electrical connection andwater connection and dismantling/ taking outGeyser of any make and capacity from any placeandinstallation, commissioning and testing to another location including grounting nut and bolts with washers or with fasteners and testing complete all asspecified and directedby Engineer-in Charge. |
28 | M&L Point wiring using approved colour coding as per IS, with stranded copper conductor2.5 Sq. mm (nominal area), single core, FRLS insulated, PVC insulated and unsheathed stranded cable 1100 volts grade, confirming to IS-694/ISI markedin and including PVC casing caping25mm wideI, medium grade, ISI marked, with mild steel sunken boxes with earth dolly zink coatedand including mounting frame andover cover plate, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earthand connected FRLS cable 1100 V grade as continuous earth wire to earth dollyfor 3 pin switch socket outlet15Amp independent board complete all as specified and directed by Engineer in charge including taking out old with switch and sockets Make : Havell’s/ Gloster cable ltd/ NICCO/RPG cables/Richa cables/poly cab wires/HPL/finolex |
29 | Supply&.fix Switch Piano typetype 230/ 250V grade on top covers 16 Amp (catered in point wiring above) |
30 | S & fixSocket outlet multipurpose use, non/shuttering non/ interlocking flush mounting type, 230/250 Volts grade on top covers16 Amp (catered in point wiring above). |
31 | Repair to solar water heater Descaling of solar collectors with acid (dilute)for solar water heater panel of 200 LPD as recommendedby manufacture cleaning and re-assembling complete and soldering for change. |
32 | Descaling of solar collectors with acid (dilute)for solar water heater panel of 100 LPD as recommendedby manufacture cleaning and re-assembling complete and soldering for change. |
33 | Takinng down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) competer for solar panel 3 Nos suitable for 200 LPDhaving 6 Nos tubes in each panel, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mountingas recommendedby manufacture cleaning and re-assembling complete and soldering for change. |
34 | Takinng down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) competer for solar panel 1 Nos suitable for 100 LPDhaving 6 Nos tubes, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mountingas recommendedby manufacture cleaning and re-assembling complete and soldering for change. |
35 | Supply and replace hose pipe for hot and cold water as per existing |
36 | Taking out U/S gate valve and supply and fixingof gate valve 15mm dia ISI marked. |
37 | Taking out U/S gate valve and supply and fixingof gate valve 20mm dia ISI marked. |
38 | Supply and replace U/S electric back up element 240 volt AC supply 3KW rating ISI marked including thermostate all as per sample. |
39 | Supply and replace U/S electric back up element 240 volt AC supply 5 KW rating ISI marked including thermostate all as per sample. |
40 | Taking out old rusted GI pipe including insulation and supply and fixing GI pipe 20 mm bore ISI marked medium grade complete with insulation comprising of glass wool, wiremesh overall aluminium cladingwith fixing steel screw 125mm center to center complete all as specified and as directed. |
41 | Repair of leakage for existing solor heater panel of 200 LPG complete all as specified and as directed.. |
42 | Supply & replace following U/S item from sheet metal enclosure complete 240 Volts, AC supply, Make : Indo Asian/Havell’s/L&T/C&S. |
43 | (a) Metallic Plug top. |
44 | (b) Metallic socket |
45 | (c ) MCB 5 to 32 Amp, 10 KA,SP "C" Series |
46 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 amp MCB 240v c series Make-HPL & equivalanet in anchor/ConaCat Pt No-DBSP10 |
47 | S & F in repalacement of rusted Angle iron of size 40x40x5 mm for supporting Solar panels on roof top including welding and fixing with suitable nut bolts and washer complete all as specified and diercted |
48 | M&L for PCC (1:2:4) type B-2 in cementconcrete for grouting agles in roof surface withusing 20 mm graded stone complete all as sepeceified and directed |
49 | Taking down carefully existing ceiling fans/wall fans of any make and sizes from ceiling/wall ,cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and reassembling after replacement of rubber real,wall fan blade , wall fan bracket ,MS nuts and bolts , split/safety pins and fan connector including replacement of old existing flexible cord connected from ceiling rose to fan through down rod and refixing and rehanging the same in existing position complete all as specified and directed by Engineer in charge. |
50 | M &L for dismantling of worn out/burnt out ceiling fans 1200 mm sweep Fans/Wall fans 200/400 mm and re-winding the ceiling fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut , complete all as specified and directed by Engineer in charge |
51 | All all as per serial item No 47 here in before but for Ceiling fans of 1400 mm sweep. Notes:for item 1 to 3 : - (a) Repairs under serial item No.01 here in before shall be carried out at the site of work. Where as fans for repair under serial item no.02 and 03 shall be issued to contractor and the same shall be returned by him after carrying out necessary repairs duly tested. (b) Rewinding under srl item no 2 & 3 shall be done with winding machine (c) Fans will be given to contractor underGate Pass in Lots of appx 50 Fans and the same shall be returned by contracter in 10 Days time after all repairs and painting.And the panelity for not receipt of repair fan in stipulated time shall be Rs 20 per fan per day. (d).Repair to ceiling fans will be carried out at MES Yards (e) Store like ball bearing, gun metal bush, capacitors and canopy required for repair/overhauling shall be measured and paid separately under relevant item of this schedule as supply only |
52 | Supply and fix in replacement of ball bearing suitable for ceiling fans of any make, type and size. Make: - SKF, NBC, and TATA |
53 | Supply and fix in replacement of bush made out of Gun metal suitable for ceiling fans of any make, type and size. Make: - Standard or as approved by GE |
54 | Supply and fix in replacement of capacitors 2.5 MFD suitable for ceiling fans of any make, type and size. Make: - Usha, Universal, Tipcon, Epcos. |
55 | Supply and fix in replacement of canopy suitable for ceiling fans of any make, type and size. Make: - Usha /Bajaj/khaitan/orient/CG/Polar /Havells |
56 | Supply and fix in replacement of down rod suitable for ceiling fans of any type and any size as per Sample/approved by GEcomplete all as specified and directed by Engineer in charge. |
57 | Supply and fix in replacement of MS clamp with nuts & bolts & locking pin suitable for ceiling fans of any make, type and size. Make: - Usha, Bajaj/khaitan/orient/CG/Polar /Havells /Anchor |
58 | Supply and fix in replacement rubber reels suitable for ceiling fans of any make, type and size. Make: - Usha, Universal, Tipcon, Epcos. |
59 | Supply and fix in replacementfan regulator Piano type for ceiling fans of any make, type and size. Make: - Anchor/Havells/Kingal/KHAITAN/orient |
60 | Supply and fix in replacementCeiling cover Plate circular type for ceiling fans of any make, type and size. Make: - Anchor/Havells/Usha/KHAITAN/orient |
61 | Taking down carefully existing exhaust fans / PVC Air Freshner Fans of any make and sizes from wall , cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and re assembling after replacement of split/safety pins, MS nuts and bolts , including replacement of old existing flexible cord connected from ceiling rose to fan and , refixingthe same in position complete all as specified and directed by Engineer in charge. Note:-Store like ball bearing, gun metal bush and capacitors required for repair/overhauling shall be measured and paid separately under relevant item of this schedule. |
62 | M &L for dismantling of worn out/burnt out Exhaust fans/ / PVC Air Freshner Fans 200 mm to 300 mmsweep and re-winding the exhaust fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, rusted nut ,bolt and washer complete all as specified and directed by Engineer in charge. |
63 | M &L for dismantling all as per serial item No 59 here in before but for Exhaust fans of size above 300 mm but up to 450 mm sweep. Note: - Repairs under serial item No.13 here in before shall be carried out at the site of work. Where as fans for repair under serial item No.14 and 15shall be issued to contractor and the same shall be returned by him after carrying out necessary repairs duly tested. |
64 | Supply and fix in replacement of ball bearing suitable for exhaust fans of size from 200 mm to 300 mm sweep. Make: - SKF, NBC, and TATA. |
65 | Supply and fix in replacement of capacitors suitable for exhaust fans of size 300 mm to 450 mm sweep. Make: - Usha, Universal, Tipcon, Epcos. |
66 | Material and labour for preparation of old surfaces of Exhaust fan by scraping out old paint with the help of emery paper/ wire brush including filling the cavities and painting with two coats ofgrey paint for exhaust fansandexhaust fan louver over a coat of red oxide primer with the help of spray machine complete all as specified and directed at site . |
67 | Supply and fix in replacement of louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size 250mm to 300 mm sweep complete all as specified and directed by Engineer in charge. |
68 | All as per serial item No 64 here in before but for exhaust fans above of size 300 mm to 450 mm sweep complete all as specified and directed by Engineer in charge. |
69 | Supply and fix in replacement of worn out nuts and bolts for fixing of Exhaust fans including finishing the disturbed surface ofwall complete all as specified and directed by Engineer in charge. |
70 | Supply and fix in replacement for PVC insulated and over all PVC sheathed copper conductorwire of size 1.5 Sqmm x 3 core,flexible wireISI marked, for connection of fan from ceiling rose to fans complete all as specified and directed by Engineer in charge. Make : finolex/polycab/Havell’s/RPG/HPL/PLAZA/RICHA CABLES |
71 | M &L for hanging clamps with provission of hook made out of MS flatwith suitable size nut,bolt and washer complete all as specified and directed. |
72 | M &L for in repair ceiling rose surface bakelite 65X50 mm, three terminal. Make : Anchor,/Legrand/Crabtree |
73 | Supply&Fixing in repair stepped type electronic fan regulator modular type, suitable for fixing in existing modular plate electronic type 230 Volts complete. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy