| 1 | Earth Work in excavation in foundation trench or drains including dressing of sides and ramming of bottoms, lift upto 1.5 m including tacking out the excavated soil and depositing and refilling of Jhiri with watering and remming and disposal surplus excavated soil as directed with in a lead of 50 m. all kind of soil. |
| 2 | P.C.C. IN FOUNDATION Providing and laying cement concrete including curing compaction etc. complete using stone aggregate 40mm nominal size (hand broken) in foundation plinth , excluding the cost of shuttering, using 1 cement:4 sand :8 aggregate mix. |
| 3 | Random rubble Stone masonary for foundation and plinth in cement sand mortar 1:6 |
| 4 | Providing and laying in position cemetn onrete including curing, compaction et. Complete in specified grade excluding the cost of centering and shttering - All work up to plinth level. 1:2:4 (1 Cement : 2 coarse sand 4 graded stone aggregate 20 mm nominal size)reduceRate -8% for mechnical mixer and vibrator |
| 5 | DPC WORK: Providing and laying in position specified grade of Cement Concerete for RCC structural Elements in beams, suspended floors, roofs, griders having slope upto 15 degree landings, balconies, shelves, chajjas,lintels,bends plain window sills,staircasesupto three floors inclu. Curing, compaction, finishing with rendering in cement sand mortar 1:3 making good and joints exclu, Cost of centering, shuttering and reinforcement with M-20 grade nominal mix 1: 1.5 : 3 (1 cement 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) |
| 6 | Stone Masonary for super structure : Random Rubble Stone masonary For Super Structure above Plinth Level one story ht. above30cm thick walls in CM1:6 |
| 7 | Piller Masonary: RR stone masonary for Pilillers above plinth level one story ht. above 30 cm thick wall in CM 1.:4Square Pillers |
| 8 | Brick masonry in column with bricks of class 75 with CM (1:6) in super structure including laying of scaffolding material complete. |
| 9 | Centering & Shuttering with plywood or steel sheets including strutting propping, bracing with wooden members and removal of formworksfor super structure upto 4.5 mtr. above plinth for suspended floors, roofs, landing staircase balconies, girders, cantivlevers bands & bed plates anchor blocks sill, chajjas, lintel beams etc. |
| 10 | Beams:-Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 11 | Slab:-Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 12 | P/F steel reinforcement for RCC work including cutting bending placing in position and binding complete including cost of binding wire in foundation raft footing step beams base of columns etc. upto Super Structure with TMT bars (Tata, Sail). |
| 13 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitered and welded with 15x3 mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 14 | Providing & fixing ms sheet double leaf door shutters in angle iron frame 35x35x5 mm suitablly diagonally braced with 25x3mm flat ironabove and below lock rail of size 50x5 mm beading extra includingall fittings, as per direction of engg. incharge but excluding coes of chokhats including two coats of anti corrastie red oxide primer panit. M.S Sheet 22 SWG |
| 15 | Providing and fixing MS sheet leaf shutter in angle iron fram 35x3mm flat above and below lock rail of size 50x50 mm beading extra including all fitting including two coats of aniticorriastie red oxide primer paint including hoock inside (MS sheet22 WG) |
| 16 | Glazed Window:Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Partly fixed and partly openable [ fixed area not to exceed 33%] |
| 17 | Supplying & fixing wire gauge of 14 mesh x24gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance |
| 18 | Providing and fixing square bars or other flat welded to window ventilators etc. |
| 19 | Filling in plinth withlocally available earth shingle under floors including watering ramming consolidating and dressing complete including cost of shinglessand. |
| 20 | Random rubble dry stone kharanja under floor 150 mm thick. |
| 21 | Cement Concrete:- Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:3:6(1 cement:3 Coarse sand :6 gradeed stone aggregate 20mm nominal size). |
| 22 | Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 23 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete(For area of each slab upto 2001Sqcm) |
| 24 | PLASTER (internal) Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 25 mm thick. |
| 25 | Plaster(Ceiling): 6 mm thick cement plaster to ceiling of mix 1:3(1 cement: 3 fine sand)6mm |
| 26 | Cement plaster on new surface on walls in cement sand mortar 1:4 including racking and joints etc. complete fine finished: with 20mm thick. |
| 27 | Grading roof for water proofing treatment withwater proffing compound: Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size) |
| 28 | P&L glazed tiles pieces for roof treatment having colour and shade as approved by the engineer in charge over 20mm thick under layer of cement mortar mix 1:4 with application of cement slurry incl. finishing of joints with white cement and pigment matching the shade curing etc. complete in all respect. |
| 29 | Gola Providing gola 75mm x 75mm in cement con. 1:2:4 (1 cement: 2 coarse sand: 4 stoneaggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design. |
| 30 | Add extra for C R Facing as per Design & Detail |
| 31 | Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) :Flushpointing. |
| 32 | Distempering with dry Distemper on NEW WORK |
| 33 | Finishing wall with water proofing cement paint of appd brand & manufacture and of reqd. shade to give an even shade including all scafolding New work (three or more coats) |
| 34 | PANTING ON DOORS & WINDOWS Painting with ready mix paint of approved brand and manufacture in all shade to give an even shadenew steel work (3 or more coat ). |
| 35 | Providing and laying in position cement concrete including curing compaction etc. complete in specified grade excluding the cost of centering and shuttering all work upto plinth level 1:2:4(1 cement:2 Coarse sand :4 gradeed stone aggregate 20 mm nominal size).Coping |
| 36 | P/L Chequered precast cement concretetiles22mm thick in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. completelaid on 20 mm thick bed of C.M 1:4 ( 1 cement: |
| 37 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 38 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.(Upto 3601 Cm2 Slabs) Green/ Black. |
| 39 | Stone slab roofing on ground floor with fine grained stone slab from approved quarry withCement batta (gola) - |
| 40 | S&F of dassa of equilent ashlads sills,cintals and dassa bearing, bed and top grwrafa me perfectly even untas skirty step etc rouy and dressed |
| 41 | Providing and laying in position M30 Grade interlocking Tiles 80mm thickcategary 3 |
| 42 | Providing and fixing Polyethylene – Aluminium Polyethylene (PE-AL-PE) composite Pressure Pipes U.V. stablised with carbon black conforming to ASTMF – 1282 – 1995 for water supply including cutting and making good the walls etc.2025 (25 mm OD) pipe |
| 43 | Providing and fixing Polyethylene – Aluminium – Polyethylene (PE-AL-PE) Composite Pressure Pipe U.V. stablised with carbon black conforming to ASTMF – 1282 – 1995 for water supply including trenching and refilling etc. (External Work).1216 (16 mm OD) pipe |
| 44 | P& F waste Coulping with fittings of approved quality /make: C.P Brass 40 mm dia |
| 45 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted 40 mm C.P. waste coupling C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor.(WVC Lab sink (I.S 2556 mark) size 530 X430X180 mm) |
| 46 | P & F chromium plated Swan-neck Laboratory Cock of approved quality/make: One Way. |
| 47 | P & F Bib Cock (IS : 8931 Mark) superior quality of approved make.C.P. Brass 400 gm, 15 mm nominal bore. |
| 48 | P & F Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.Brass wt. 400 gm, 15 mm |
| 49 | P & F Inlet connection (Angle Valves) Superior quality of approved make C.P. Intel connection 15 mmbrass(IS : 8931) |
| 50 | P & F 15 mm dia connection pipe of approved quality make PVC Pipes with nuts 450 mm. |
| 51 | P & F Full way valve (IS : 778 Mark) or wheel valve of approved make. Gun metal 15 mm nominal bore. |
| 52 | P & F Stop cock (IS:8931 Mark),Superior quality and of approved mark: Brass 400 gm. 15 mm nominal bore |
| 53 | P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia. |
| 54 | P & F PVC Storage Tank ISI Marked ( IS: 12701) indicating the BIS license No. of approved make with cover, 25mm dia 1 M long G.I. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity |
| 55 | P&F GI Pipes (External Work) with GI fittings excluding union (SI: 1239 Mark) including trenching and refilling each etc. 15 mm dia nominal bore B Class |
| 56 | Providing and fixing Ist quality standard White Ivory Glazed Tiles ISI marked [IS:13753] of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). |
| 57 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted 40 mm C.P. waste coupling C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor.(WVC Lab sink (I.S 2556 mark) size 530 X430X180 mm) |
| 58 | P&F Indian type white glazed vitreous china W.C. orissa pan (IS:2556 Mark) with 100 mm vitreous china P or S trapSize 530x410 mm. |
| 59 | Construction of soakage well in all types of soil of approved drawing, top 90cm portion in 450mm thick masonary with CM 1:6, 800mm thick stone slab covering, jointing of slab in CM 1:3, ralthal, khananja 400mm thick M-15 Grade C.C. flooring, earth work etc. complete incl. disposal of surplus earth within a lead of 50mtr. inner Dia 60cm &10to12mtr deep |
| 60 | P&F PVC rigid pipe IS 4985 class llnd class 4 kg/cm2 of app. quality make I/c jointing the pipe with solvent cement rubber ring and lubricant 110mm dia |
| 61 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5110mm dia |
| 62 | Pipe Clip110 mm dia |
| 63 | Wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make group-2 Light point Short point (up to 3 mtr.) |
| 64 | Medium point (up to 6 mtr) |
| 65 | Long point (up to 10 mtr) |
| 66 | Fan point Short point (up to 3 mtr.) |
| 67 | Medium point (up to 6 mtr) |
| 68 | Long point (up to 10 mtr) |
| 69 | Wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 KV grade (IS: 694) of approved make in surface/reces group - On board |
| 70 | S & F follwing sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. Group-225 mm dia |
| 71 | Supplying and drawi;ng FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. Group-2 1 x 1.5 sq. mm |
| 72 | 2 x 1.5 sq. mm |
| 73 | 2 x 2.5 sq. mm |
| 74 | P & F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828 (1996)/conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. Group-2 6 A to 32 A rating |
| 75 | P & F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with 100 Amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to IS 13032 & IS 8623 including making internal DB termination with copper lux, testing etc. as reqd. . group-2Single door(Single Phase) 8 way |
| 76 | P & F strip fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating/stove enamelled non corrosive UV resist EP channel)complete with accessories(Low loss copperchoke, starter, starter seat)/Electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(Without tube)1x36 watts with OCCB. Group-2 |
| 77 | P & F Fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts |
| 78 | P/I aying PVC insulated & PVC sheathed cable of 1.1 kV grade with aluminium conductor of IS:1554 P-I of Groups of approved make in ground as per IS:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, Iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm |
| 79 | P & F star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated |
| 80 | P & F IS:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup-2 (E071400) |
| 81 | P & F ISI marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required |
| 82 | P & F 18 swg MS Recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp-1 |
| 83 | P & F 18 SWG Sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmX 100 mmX60 mm |
| 84 | P&F 240/415 V isolator conforming to IS : 13947-III/ IEC 60947-3 on existing board/ sheet including making connection, testing etc. as required 30 A/ 40 A rating. |
| 85 | P & F socket size flush type 120/280 watt rotary 5 steep fan regulator including making connection testing etc. as required. |
| 86 | P & F ISI marked (IS: 3854) 6 amp. Flush type switch including cutting hole in tile and making connection testing etc. as required. |
| 87 | P & F of 3 pin 6 amp. Flush type socket including cutting hole in tile making connection testing etc. as required. |